Message ID: 5     Entry time: Fri Mar 5 11:05:13 2021
Author: Stephen 
Type: General 
Category: Design specs 
Subject: Feasibility of 6" optic size in CAD 

6" vs 4" optic size comparison using CAD - worth hopping into the 3D geometry using the link below, but also posting a couple of images below.

1) We can adjust all parameters relating to the suspension frame except the beam height. Is there enough clearance under the optic for the internal shield?

--> Using the representation of the MOS structure as-is, there is about 1" of clearance between the bottom panel of the first/internal shield under the 6" case, compared with 2" of clearance in the 4" case. This is not very scary, and suggests that we could use a 6" optic size.

2) Any other concerns at this point?

--> Not really, there are degrees of freedom to absorb other issues that arise from the simple 4" --> 6" parameter shift

EASM posted at https://caltech.app.box.com/folder/132918404089

 

Attachment 1: 4in_from_20210305_easm.png  104 kB  | Hide | Hide all | Show all
4in_from_20210305_easm.png
Attachment 2: 6in_from_20210305_easm.png  103 kB  | Show | Hide all | Show all