Entry  Fri Nov 5 11:51:50 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um HITRAN_line_strenghts.pdfbroadened_spectrum.pdfPP_broadened_spectrum.pdf
    Reply  Tue Nov 16 11:47:54 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um PP_broadened_spectrum.pdf
Message ID: 48     Entry time: Tue Nov 16 11:47:54 2021     In reply to: 47
Author: Paco 
Type: General 
Category: Design specs 
Subject: Estimate of in-air absorption near 2.05 um 

[Paco]

There was an error in the last plot of the previous log. This was correctly pointed out by rana's pointing out that the broadening from air should be independent of the CO2 concentration, so nominally both curves should coincide with each other. Nevertheless, this doesn't affect the earlier conclusions -->

The PMC loss by background, pressure broadened absorption lines at 2049.9 nm by CO2 is < 1 ppm.

The results posted here are reflected in the latest notebook commit here.

Attachment 1: PP_broadened_spectrum.pdf  198 kB  | Hide | Hide all
PP_broadened_spectrum.pdf
ELOG V3.1.3-