Fri Oct 1 12:01:24 2021, Paco, General, Design specs, TM Barrel coating emissivity   
|
Fri Oct 1 13:24:40 2021, Aidan, General, Design specs, TM Barrel coating emissivity
|
Fri Oct 1 14:11:23 2021, Paco, General, Design specs, TM Barrel coating emissivity  
|
|
Message ID: 34
Entry time: Fri Oct 1 12:01:24 2021
Reply to this: 35
|
Author: |
Paco |
Type: |
General |
Category: |
Design specs |
Subject: |
TM Barrel coating emissivity |
|
|
[Paco, Nina, Aidan]
We ran our stack emissivity calculation on different AR stacks to try and make a decision for the TM barrel coatings. This code has yet to be validated by cross checking against tmm as suggested by Chris. The proposed layer structures by Aidan and Nina are:
- *| Air || SiO2 x 800 nm || Ta2O5 x 5 um || Silicon |*
- *| Air || Ta2O5 x 10 um || Sio2 x 20 nm || Silicon |*
- *| Air || SiO2 x 100 nm || TiO2 x 1 um || Silicon |*
Attachments # 1-3 show the emissivity curves for these simple dielectric stacks. Attachment #4 shows the extinction coefficient data used for the three different materials. The next step is to validate these results with tmm, but so far it looks like TiO2 might be a good absorbing film option. |
|
|
|
|
|
|
|
|