Message ID: 33     Entry time: Fri Oct 1 11:52:06 2021     In reply to: 28
Author: Paco 
Type: General 
Category: Design specs 
Subject: HR coating emissivity 

[Paco, Nina, Aidan]

Updated the stack emissivity code to use the Kitamura paper fused silica dispersion which has a prominent 20 um absorption peak which wasn't there before... (data was up to 15 um, and extrapolated smoothly beyond). The updated HR stack emissivities are in Attachments #1 - #2. A weird feature I don't quite understand is the discontinous jump at ~ 59 um ... 

Attachment 1: ETM_210409_120913_emissivity.pdf  129 kB  Uploaded Fri Oct 1 12:58:32 2021  | Hide | Hide all | Show all
ETM_210409_120913_emissivity.pdf
Attachment 2: interpolated_n_k.pdf  65 kB  Uploaded Fri Oct 1 12:59:12 2021  | Show | Hide all | Show all
ELOG V3.1.3-