40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog  Not logged in ELOG logo
Entry  Sun Sep 19 18:52:58 2021, Paco, General, Design specs, HR coating emissivity ETM_210409_120913_emissivity.pdfinterpolated_TF_k.pdf
    Reply  Fri Oct 1 11:52:06 2021, Paco, General, Design specs, HR coating emissivity ETM_210409_120913_emissivity.pdfinterpolated_n_k.pdf
Message ID: 33     Entry time: Fri Oct 1 11:52:06 2021     In reply to: 28
Author: Paco 
Type: General 
Category: Design specs 
Subject: HR coating emissivity 

[Paco, Nina, Aidan]

Updated the stack emissivity code to use the Kitamura paper fused silica dispersion which has a prominent 20 um absorption peak which wasn't there before... (data was up to 15 um, and extrapolated smoothly beyond). The updated HR stack emissivities are in Attachments #1 - #2. A weird feature I don't quite understand is the discontinous jump at ~ 59 um ... 

Attachment 1: ETM_210409_120913_emissivity.pdf  129 kB  Uploaded Fri Oct 1 12:58:32 2021  | Show | Show all
Attachment 2: interpolated_n_k.pdf  65 kB  Uploaded Fri Oct 1 12:59:12 2021  | Show | Show all
ELOG V3.1.3-