[Paco]

Alright, I've done a re-optimization targetting a wider T band around 2128 nm. For this I modified the scalar minimization cost to evaluate the curvature term (instead of the slope) around a wide range of 10% (instead of 1%). Furthermore, in prevision of the overall effects of using the updated dispersion, I intentionally optimized for a lower T such that we intentionally overshoot.

The results are in Attachment #1 and Attachment #2.

Attachment 1: ETM210909190218.pdf  205 kB  Uploaded Thu Sep 9 21:46:06 2021  | Hide | Hide all
ETM210909190218.pdf
Attachment 2: ITMLayers210909204021.pdf  203 kB  Uploaded Thu Sep 9 21:46:17 2021  | Hide | Hide all
ITMLayers210909204021.pdf