40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog  Not logged in ELOG logo
Entry  Fri May 7 09:57:18 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept mariner_suspension_test_chamber_concept.jpg
    Reply  Wed Jul 7 16:32:27 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept 
Message ID: 13     Entry time: Fri May 7 09:57:18 2021     Reply to this: 18
Author: Stephen 
Type: General 
Category: Equipment 
Subject: Overall Dimensions for Mariner Suspension Test Chamber Concept 

Koji, Stephen

Putting together Koji's design work with Stephen's CAD, we consider the size of a test chamber for the Mariner suspension.

Koji's design uses a 6" x 6" Si optic, with an overall height of about 21.5".

Stephen's offsets suggest a true shield footprint of 14" x 14" with an overall height of 24".

With generous clearances on all sides, a test chamber with a rectangular footprint internally of about 38" x 32" with an internal height of 34" would be suitable. This scale seems similar to the Thomas Vacuum Chamber in Downs, and suggests feasibility. It will be interesting to kick off conversations with a fabricator to get a sense for this.

This exercise generated a few questions worth considering; feel welcome to add to this list!

  • do we need to have the suspended snout(s)?
  • are we studying an ITM or ETM (or both)?
  • relays or other optical components on the baseplate?
  • angles of optical levers?
  • off center mounting?
  • two doors for front/back access?

 

Attachment 1: mariner_suspension_test_chamber_concept.jpg  104 kB  Uploaded Fri May 7 11:17:20 2021  | Show | Show all