40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  COMSOL elog, Page 3 of 3  Not logged in ELOG logo
Entry  Mon Jul 15 13:14:30 2013, Emory Brown, Optics, General, Umax curves for varying height test masses MassComparison.png
Entry  Tue Jul 23 18:26:04 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23.bmpTE_calc_Jul23.zipJul_23.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:45 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
Entry  Wed Jul 24 21:08:24 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul24.pdfJul24_acalc.pdf
    Reply  Thu Jul 25 11:36:17 2013, rana, Optics, General, TR results for different dimensions 
    Reply  Thu Jul 25 13:21:46 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul_25.pdf
    Reply  Thu Jul 25 15:54:58 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul_25_1.pdfJul_25_2.pdfrelative_plot.pdf
Entry  Mon Jul 29 22:42:57 2013, Deep Chatterjee, Optics, General, Avoiding transient solutions in the Computation of TE/TR noise Jul29_2.pdf
Entry  Wed Jul 31 15:39:11 2013, Deep Chatterjee, Optics, General, First try with paramter optimization for TE and TR noise profiles Jul31_param_opt.pdf
Entry  Thu Aug 8 17:17:19 2013, Deep Chatterjee, Optics, General, Something like cancellation suspected_cance_AUg8l.pdf
Entry  Wed Nov 13 23:55:44 2013, Chris Couste, Optics, Analysis, Optical Mount Vibrational Analysis 
Entry  Mon Nov 18 15:56:59 2013, Chris Couste, Optics, Analysis, Representative Models Custom_Closed.JPGcustom_open.JPGStock_Closed.JPGStock_Open.JPG
Entry  Fri Nov 22 21:04:53 2013, Chris Couste, Optics, Analysis, analysis 
Entry  Fri Jan 24 17:26:38 2014, Chris Cousté, Optics, Analysis, Mount Analysis Functional! 
Entry  Sun Feb 16 21:10:56 2014, Chris Cousté, Optics, Analysis, Optical Mount data compilation 1: Aluminum aluminum2.pngaluminum3.png
Entry  Sun Jun 22 23:44:56 2014, Sam Moore, Optics, , Going through Heinert's 'TR noise of cylindrical test masses' paper 
    Reply  Mon Jun 23 11:40:17 2014, Sam Moore, Optics, , Going through Heinert's 'TR noise of cylindrical test masses' paper 
    Reply  Mon Jun 23 16:10:17 2014, Matt A., Optics, , Going through Heinert's 'TR noise of cylindrical test masses' paper SamEq1.pngSamEq2.pngSamEq3.pngSamEq4.png
Entry  Tue Jun 24 14:35:42 2014, Sam Moore, Optics, General, Trying to Verify the Heinert Model 06_23_14.pdf
    Reply  Tue Jun 24 17:05:24 2014, Sam Moore, Optics, General, Trying to Verify the Heinert Model temperature.pngnoiseAmplitude_agreement.png
Entry  Sat Jun 28 21:59:11 2014, Sam Moore, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 6_27_14.pdf
    Reply  Sun Jun 29 15:37:18 2014, Sam Moore, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 6_29_14.pdf
    Reply  Sun Jun 29 20:25:44 2014, Koji, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 
Entry  Sat Jul 5 13:04:32 2014, Sam Moore, Optics, , Heinert Model TR Noise Verification threeD_cylinderTRnoise.pngoneDcylinderTRnoise_copy.png
    Reply  Mon Jul 7 19:47:00 2014, Koji, Optics, , Heinert Model TR Noise Verification 
Entry  Thu Jul 10 16:51:14 2014, Sam Moore, Optics, General, Duan and Heinert Comparison 7_10_14.pdf
    Reply  Fri Jul 11 10:58:18 2014, not Koji, Optics, , Heinert Model TR Noise Verification heinert_analyticalTest_residual_threeD.epsheinert_analyticTest_residual_oneD.eps
Entry  Mon Jul 14 19:09:14 2014, Sam Moore, Optics, General, Using Heinert's Solution for Duan's Parameters oneD_duanParams_residual-eps-converted-to.pdfthreeD_duanParams_residual-eps-converted-to.pdf
    Reply  Mon Jul 14 19:14:31 2014, Sam Moore, Optics, General, Duan and Heinert Comparison duan_heinert_comparisonInfinite-eps-converted-to.pdf
Entry  Thu Jul 31 20:55:38 2014, Sam Moore, Optics, General, Finding the Right Meshing for the TIR cavity 7_30_14.pdf
    Reply  Sat Aug 2 00:22:34 2014, Sam Moore, Optics, General, Finding the Right Meshing for the TIR cavity 8_1_14.pdf
Entry  Thu Jan 18 21:13:59 2018, aaron, Optics, PonderSqueeze, modifications to Gautam's 40m finesse model 