40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  COMSOL elog, Page 1 of 3  Not logged in ELOG logo
Entry  Thu Nov 2 17:23:56 2017, Aaron, Mechanics, PonderSqueeze, Modelling suspension noise 
    Reply  Fri Nov 3 15:03:10 2017, Aaron, Mechanics, PonderSqueeze, Modelling suspension noise 
    Reply  Wed Nov 15 14:05:12 2017, Aaron, Mechanics, PonderSqueeze, Modelling suspension noise 
Entry  Tue Jun 25 15:16:59 2013, Arnaldo Rodriguez, Optics, General, Setting Up Looped Simulation for PID Controller Defocus.pngITMPlusRing.m
Entry  Wed Jun 26 13:52:06 2013, Arnaldo Rodriguez, Optics, General, Verifying Relative Error in Defocus for Regular and Manual-Loop Simulations Defocus_Error.png
Entry  Wed Jun 26 15:23:55 2013, Arnaldo Rodriguez, Optics, General, Solving Time per Loop in Manual Dynamic Simulation SolvingTimePerLoop.png
Entry  Thu Jun 27 15:06:13 2013, Arnaldo Rodriguez, Optics, General, PID Function in Manual Simulation ITMPlusRingPlusPID.mPID.m
Entry  Thu Jun 27 17:12:33 2013, Arnaldo Rodriguez, Optics, General, Defocusing in P-Controlled Manual Simulation Defocus_(P_Active).png
Entry  Mon Jul 1 13:01:58 2013, Arnaldo Rodriguez, Optics, General, Brief Parameter Study on P-active Control Loop K_p.png
Entry  Mon Jul 1 17:31:40 2013, Arnaldo Rodriguez, Optics, General, Parameter Study on Sampling Time for P-active Loop Deltat.png
Entry  Thu Feb 14 12:38:51 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-14_12-47-11.pngScreenshot_from_2019-02-14_15-07-40.pngScreenshot_from_2019-02-14_15-41-41.pnggraph.pdf
    Reply  Fri Feb 15 21:05:31 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-15_21-40-01.png
    Reply  Tue Feb 19 19:52:53 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-19_19-52-10.png
    Reply  Fri Mar 1 19:33:40 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-01_19-35-32.pngScreenshot_from_2019-03-01_19-36-02.pngScreenshot_from_2019-03-01_19-46-25.png
    Reply  Mon Mar 4 17:22:07 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-04_19-13-28.pngScreenshot_from_2019-03-04_19-14-41.pngScreenshot_from_2019-03-04_19-15-37.pngScreenshot_from_2019-03-04_19-15-56.png
    Reply  Wed Mar 6 09:51:18 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-06_09-31-24.png
    Reply  Thu Mar 7 10:10:37 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-07_10-10-47.png
Entry  Wed Nov 13 23:55:44 2013, Chris Couste, Optics, Analysis, Optical Mount Vibrational Analysis 
Entry  Mon Nov 18 15:56:59 2013, Chris Couste, Optics, Analysis, Representative Models Custom_Closed.JPGcustom_open.JPGStock_Closed.JPGStock_Open.JPG
Entry  Fri Nov 22 21:04:53 2013, Chris Couste, Optics, Analysis, analysis 
Entry  Fri Jan 24 17:26:38 2014, Chris Cousté, Optics, Analysis, Mount Analysis Functional! 
Entry  Sun Feb 16 21:10:56 2014, Chris Cousté, Optics, Analysis, Optical Mount data compilation 1: Aluminum aluminum2.pngaluminum3.png
Entry  Wed Jun 5 13:49:13 2013, Deep Chatterjee, Optics, General, Difference in the Levin and Liu & Thorne results for thermal noise Levin_throne_comparison.pdfLevin_throne_comparison.png
Entry  Wed Jun 5 20:39:48 2013, Deep Chatterjee, Optics, General, Conventional Thermal noise (Sec V) from Liu & Thorne Thorne_thermal_noise.pngPercentage_difference.pngThorne_thermal_noise.pdfPercentage_difference.pdf
Entry  Wed Jun 5 20:54:59 2013, Deep Chatterjee, General, General, Bessel Function roots Difference_between_algorithms.pngbessel_zeros.m
Entry  Thu Jun 6 17:00:11 2013, Deep Chatterjee, Optics, General, Comparison of ITM and FTM geometries (FIG. 3 Liu & Thorne) C_FTM.pngC_FTM.pdfFig3_Liu&Thorn.bmp
Entry  Fri Jun 7 17:41:41 2013, Deep Chatterjee, General, General, Disscussion of the code of a 'comsol with matlab' model file Iron_Bar_test1_model.m
    Reply  Tue Jun 11 10:21:05 2013, Deep Chatterjee, General, General, Re: Disscussion of the code of a 'comsol with matlab' model file 
Entry  Tue Jun 11 17:04:33 2013, Deep Chatterjee, General, General, Analyzing the file 'thermo_refractive_COMSOL_1D_axisymmetric' by Koji Arai 
Entry  Wed Jun 12 13:52:44 2013, Deep Chatterjee, Optics, General, Difference in COMSOL and Analytic solution for TR noise analytic~COMSOL.png
Entry  Thu Jun 20 12:41:01 2013, Deep Chatterjee, General, General, The expression for the "work dissipated" in the TE and TR noise calculations dissipated_work.pdf
Entry  Thu Jun 20 16:29:38 2013, Deep Chatterjee, Optics, General, Differences on using a coarser mesh in calculating TR noise difference_in_mesh.png
Entry  Mon Jun 24 18:00:26 2013, Deep Chatterjee, Optics, General, The problem of TE Noise calculation for a beam passing through a cylindrical substrate 
Entry  Fri Jun 28 14:03:07 2013, Deep Chatterjee, General, General, Approach for TE noise for beam in cavity LL_derivations.pdf
Entry  Thu Jul 4 15:23:47 2013, Deep Chatterjee, Optics, General, Attempt to compute TE noise following Liu and Thorne Liu&Thorne_type.bmpsomething_like_TE_1.bmpsomething_like_TE_1_10times.bmpsomething_like_TE_1_1000times.bmp2D_almost_infinte_TE.mph
    Reply  Fri Jul 5 14:06:24 2013, Deep Chatterjee, Optics, General, Attempt to compute TE noise following Liu and Thorne comparison.bmpL&T_COMSOL_difference.bmp
Entry  Thu Jul 11 19:16:12 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script TE_model.malmost_infinite_2D_axisym_TE_4.m
    Reply  Fri Jul 12 19:43:32 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script codes_TE_calc.zip
    Reply  Sun Jul 14 15:13:46 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script codes_TE_calc_(2).zip
    Reply  Mon Jul 15 16:05:29 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script codes_TE_calc.zipJul_15.bmp
Entry  Tue Jul 23 18:26:04 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23.bmpTE_calc_Jul23.zipJul_23.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:37 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
    Reply  Tue Jul 23 20:53:45 2013, Deep Chatterjee, Optics, General, Comparison between Liu and Thorne Results and COMSOL results for TE noise Jul_23_bettermesh2.eps
Entry  Wed Jul 24 21:08:24 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul24.pdfJul24_acalc.pdf
    Reply  Thu Jul 25 13:21:46 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul_25.pdf
ELOG V3.1.3-