40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  COMSOL elog, Page 2 of 2  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Wed Nov 13 23:55:44 2013, Chris Couste, Optics, Analysis, Optical Mount Vibrational Analysis 
Entry  Mon Nov 18 15:56:59 2013, Chris Couste, Optics, Analysis, Representative Models Custom_Closed.JPGcustom_open.JPGStock_Closed.JPGStock_Open.JPG
Entry  Fri Nov 22 21:04:53 2013, Chris Couste, Optics, Analysis, analysis 
Entry  Fri Jan 24 17:26:38 2014, Chris Cousté, Optics, Analysis, Mount Analysis Functional! 
Entry  Sun Feb 16 21:10:56 2014, Chris Cousté, Optics, Analysis, Optical Mount data compilation 1: Aluminum aluminum2.pngaluminum3.png
Entry  Thu Apr 17 16:52:09 2014, Evan, General, Characterization, Interpreting logfiles and picking a solver 
Entry  Sun Jun 22 23:44:56 2014, Sam Moore, Optics, , Going through Heinert's 'TR noise of cylindrical test masses' paper 
    Reply  Mon Jun 23 11:40:17 2014, Sam Moore, Optics, , Going through Heinert's 'TR noise of cylindrical test masses' paper 
    Reply  Mon Jun 23 16:10:17 2014, Matt A., Optics, , Going through Heinert's 'TR noise of cylindrical test masses' paper SamEq1.pngSamEq2.pngSamEq3.pngSamEq4.png
Entry  Tue Jun 24 14:35:42 2014, Sam Moore, Optics, General, Trying to Verify the Heinert Model 06_23_14.pdf
    Reply  Tue Jun 24 17:05:24 2014, Sam Moore, Optics, General, Trying to Verify the Heinert Model temperature.pngnoiseAmplitude_agreement.png
Entry  Sat Jun 28 21:59:11 2014, Sam Moore, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 6_27_14.pdf
    Reply  Sun Jun 29 15:37:18 2014, Sam Moore, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 6_29_14.pdf
    Reply  Sun Jun 29 20:25:44 2014, Koji, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 
Entry  Sat Jul 5 13:04:32 2014, Sam Moore, Optics, , Heinert Model TR Noise Verification threeD_cylinderTRnoise.pngoneDcylinderTRnoise_copy.png
    Reply  Mon Jul 7 19:47:00 2014, Koji, Optics, , Heinert Model TR Noise Verification 
       Reply  Fri Jul 11 10:58:18 2014, not Koji, Optics, , Heinert Model TR Noise Verification heinert_analyticalTest_residual_threeD.epsheinert_analyticTest_residual_oneD.eps
Entry  Mon Jul 14 19:09:14 2014, Sam Moore, Optics, General, Using Heinert's Solution for Duan's Parameters oneD_duanParams_residual-eps-converted-to.pdfthreeD_duanParams_residual-eps-converted-to.pdf
Entry  Thu Jul 10 16:51:14 2014, Sam Moore, Optics, General, Duan and Heinert Comparison 7_10_14.pdf
    Reply  Mon Jul 14 19:14:31 2014, Sam Moore, Optics, General, Duan and Heinert Comparison duan_heinert_comparisonInfinite-eps-converted-to.pdf
Entry  Thu Jul 31 20:55:38 2014, Sam Moore, Optics, General, Finding the Right Meshing for the TIR cavity 7_30_14.pdf
    Reply  Sat Aug 2 00:22:34 2014, Sam Moore, Optics, General, Finding the Right Meshing for the TIR cavity 8_1_14.pdf
Entry  Tue Sep 30 11:30:27 2014, Nic, Dmass, Evan, General, Configuration, Gravity in Comsol 
Entry  Sat Sep 5 15:04:43 2015, Dennis Coyne, Mechanics, Configuration, summary of FEA modal model to State Space model  FEM2SS_summary.docx
Entry  Sat Sep 5 15:17:41 2015, rana, General, Configuration, FEA logs merged 
Entry  Tue Jun 28 15:50:45 2016, Joy Westland, Mechanics, Analysis, A Simple Model of the Modal Analysis of a Cantilever Circular/Cylinder Cross Section in ANSYS tutorial Simple_Cantilever_200_mm_Long_Geometry.PNGSimple_Cantilever_200_mm_Long.PNGComparison_between_ANSYS_and_Calculations_Fused_Silica_200_mm_L.PNG
Entry  Tue Jun 28 16:54:23 2016, Nikhil Mathur, Mechanics, Analysis, Ansys 14.5 Indroductory Tutorial: Modal Frequency Convergence ConvergenceTutorial.pdf.gz
Entry  Wed Jun 29 14:14:44 2016, Joy Westland, Mechanics, Analysis, ANSYS Tutorials with Basic Meshing 
Entry  Fri Jul 29 14:33:41 2016, Joy Westland, Mechanics, General, A Tutorial in Importing SolidWorks Files and Applying a Gaussian Force in ANSYS for a LIGO Test Mass Bottom_Test_Mass_With_Ears.PNGApplying_Parameters.PNGApplying_Gaussian_Force.PNG
Entry  Mon Jul 24 15:35:34 2017, Mariia, General, Configuration, Running Comsol to Matlab  
    Reply  Mon Jul 24 15:54:26 2017, Koji, General, Configuration, Running Comsol to Matlab  
    Reply  Wed Jul 26 20:14:46 2017, rana, General, Configuration, Running Comsol to Matlab  
Entry  Fri Jul 28 15:48:58 2017, Mariia, General, Configuration, Comsol batch for windows 
Entry  Mon Jul 31 22:18:57 2017, rana, General, General, using more than 12 cores in matlab Screen_Shot_2017-07-31_at_10.11.35_PM.png
Entry  Thu Nov 2 17:23:56 2017, Aaron, Mechanics, PonderSqueeze, Modelling suspension noise 
    Reply  Fri Nov 3 15:03:10 2017, Aaron, Mechanics, PonderSqueeze, Modelling suspension noise 
       Reply  Wed Nov 15 14:05:12 2017, Aaron, Mechanics, PonderSqueeze, Modelling suspension noise 
Entry  Mon Dec 4 16:27:13 2017, aaron, Mechanics, PonderSqueeze,  
    Reply  Mon Dec 4 17:42:53 2017, gautam, Mechanics, PonderSqueeze, FEA on optimus 
       Reply  Mon Dec 4 19:49:32 2017, gautam, Mechanics, PonderSqueeze, FEA on optimus 
          Reply  Tue Dec 5 10:50:54 2017, aaron, Mechanics, PonderSqueeze, FEA on optimus 
             Reply  Tue Dec 5 19:50:47 2017, aaron, Mechanics, PonderSqueeze, FEA on optimus 
                Reply  Tue Dec 12 11:50:12 2017, aaron, Mechanics, PonderSqueeze, FEA on optimus SERaLIGO.jpg
Entry  Thu Jan 18 21:13:59 2018, aaron, Optics, PonderSqueeze, modifications to Gautam's 40m finesse model 
Entry  Mon Jan 22 21:13:25 2018, aaron, Mechanics, PonderSqueeze, tips from Shoaib 
    Reply  Mon Jan 29 23:02:13 2018, aaron, Mechanics, PonderSqueeze, tips from Shoaib 
Entry  Sat Mar 17 15:27:48 2018, rana, General, General, file size >> small 
    Reply  Mon Aug 20 15:44:56 2018, rana, General, General, file size >> small 
Entry  Sun Aug 26 16:42:54 2018, rana, Mechanics, Analysis, Test Mass Thermal Noise: Consistency Checks 
Entry  Sun May 7 18:22:35 2017, rana, General, Voyager, Voyager ITM: Radiative cooling with cold shield and cold CP ITM-ColdShield-CP.png
    Reply  Sun Aug 26 19:21:27 2018, rana, General, Voyager, Voyager ITM: Radiative cooling with cold shield and cold CP ITM-Cooldown.pdfCoolDown.webm
Entry  Thu Feb 14 12:38:51 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-14_12-47-11.pngScreenshot_from_2019-02-14_15-07-40.pngScreenshot_from_2019-02-14_15-41-41.pnggraph.pdf
    Reply  Fri Feb 15 21:05:31 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-15_21-40-01.png
       Reply  Tue Feb 19 19:52:53 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-19_19-52-10.png
          Reply  Fri Mar 1 19:33:40 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-01_19-35-32.pngScreenshot_from_2019-03-01_19-36-02.pngScreenshot_from_2019-03-01_19-46-25.png
             Reply  Mon Mar 4 17:22:07 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-04_19-13-28.pngScreenshot_from_2019-03-04_19-14-41.pngScreenshot_from_2019-03-04_19-15-37.pngScreenshot_from_2019-03-04_19-15-56.png
                Reply  Wed Mar 6 09:51:18 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-06_09-31-24.png
                   Reply  Thu Mar 7 10:10:37 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-07_10-10-47.png
Entry  Tue May 12 14:16:28 2020, Koji, General, General, FEA tutorial resources 
Entry  Fri Dec 4 18:32:02 2015, rana, General, Configuration, COMSOL: remote server w/ matlab BrownianSweep.tgz
    Reply  Tue Aug 11 11:16:29 2020, aaron, General, Configuration, COMSOL with Matlab without display 
    Reply  Tue Aug 11 16:35:07 2020, aaron, General, Configuration, COMSOL: remote server w/ matlab 
ELOG V3.1.3-