40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  COMSOL elog, Page 3 of 3  Not logged in ELOG logo
    Reply  Fri Jul 12 19:43:32 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script codes_TE_calc.zip
    Reply  Sun Jul 14 15:13:46 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script codes_TE_calc_(2).zip
    Reply  Mon Jul 15 16:05:29 2013, Deep Chatterjee, General, General, TE noise problem - Matlab script codes_TE_calc.zipJul_15.bmp
Entry  Wed Jul 24 21:08:24 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul24.pdfJul24_acalc.pdf
    Reply  Thu Jul 25 11:36:17 2013, rana, Optics, General, TR results for different dimensions 
    Reply  Thu Jul 25 13:21:46 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul_25.pdf
    Reply  Thu Jul 25 15:54:58 2013, Deep Chatterjee, Optics, General, TR results for different dimensions Jul_25_1.pdfJul_25_2.pdfrelative_plot.pdf
Entry  Sun Aug 26 16:42:54 2018, rana, Mechanics, Analysis, Test Mass Thermal Noise: Consistency Checks 
Entry  Wed Jun 19 14:59:13 2013, Emory Brown, General, General, The Relative Residual Convergence Error 
    Reply  Thu Jun 20 10:26:38 2013, Matt A., General, General, The Relative Residual Convergence Error 
    Reply  Thu Jun 20 12:51:44 2013, Emory Brown, General, General, The Relative Residual Convergence Error 
Entry  Thu Jun 20 12:41:01 2013, Deep Chatterjee, General, General, The expression for the "work dissipated" in the TE and TR noise calculations dissipated_work.pdf
Entry  Mon Jun 24 18:00:26 2013, Deep Chatterjee, Optics, General, The problem of TE Noise calculation for a beam passing through a cylindrical substrate 
Entry  Tue Jun 24 14:35:42 2014, Sam Moore, Optics, General, Trying to Verify the Heinert Model 06_23_14.pdf
    Reply  Tue Jun 24 17:05:24 2014, Sam Moore, Optics, General, Trying to Verify the Heinert Model temperature.pngnoiseAmplitude_agreement.png
Entry  Mon Jul 15 13:14:30 2013, Emory Brown, Optics, General, Umax curves for varying height test masses MassComparison.png
Entry  Mon Jul 14 19:09:14 2014, Sam Moore, Optics, General, Using Heinert's Solution for Duan's Parameters oneD_duanParams_residual-eps-converted-to.pdfthreeD_duanParams_residual-eps-converted-to.pdf
Entry  Tue Jul 2 13:32:30 2013, Emory Brown, Optics, General, Using Matlab to run our COMSOL simulations model_7_1_13.mlooper.m
    Reply  Wed Jul 3 00:04:46 2013, Koji, Optics, General, Using Matlab to run our COMSOL simulations 
Entry  Wed Jun 26 13:52:06 2013, Arnaldo Rodriguez, Optics, General, Verifying Relative Error in Defocus for Regular and Manual-Loop Simulations Defocus_Error.png
Entry  Sun May 7 18:22:35 2017, rana, General, Voyager, Voyager ITM: Radiative cooling with cold shield and cold CP ITM-ColdShield-CP.png
    Reply  Sun Aug 26 19:21:27 2018, rana, General, Voyager, Voyager ITM: Radiative cooling with cold shield and cold CP ITM-Cooldown.pdfCoolDown.webm
Entry  Fri Nov 22 21:04:53 2013, Chris Couste, Optics, Analysis, analysis 
Entry  Thu Feb 14 12:38:51 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-14_12-47-11.pngScreenshot_from_2019-02-14_15-07-40.pngScreenshot_from_2019-02-14_15-41-41.pnggraph.pdf
    Reply  Fri Feb 15 21:05:31 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-15_21-40-01.png
    Reply  Tue Feb 19 19:52:53 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-19_19-52-10.png
    Reply  Fri Mar 1 19:33:40 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-01_19-35-32.pngScreenshot_from_2019-03-01_19-36-02.pngScreenshot_from_2019-03-01_19-46-25.png
    Reply  Mon Mar 4 17:22:07 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-04_19-13-28.pngScreenshot_from_2019-03-04_19-14-41.pngScreenshot_from_2019-03-04_19-15-37.pngScreenshot_from_2019-03-04_19-15-56.png
    Reply  Wed Mar 6 09:51:18 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-06_09-31-24.png
    Reply  Thu Mar 7 10:10:37 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-07_10-10-47.png
Entry  Sat Mar 17 15:27:48 2018, rana, General, General, file size >> small 
    Reply  Mon Aug 20 15:44:56 2018, rana, General, General, file size >> small 
Entry  Thu Jan 18 21:13:59 2018, aaron, Optics, PonderSqueeze, modifications to Gautam's 40m finesse model 
Entry  Sat Sep 5 15:04:43 2015, Dennis Coyne, Mechanics, Configuration, summary of FEA modal model to State Space model  FEM2SS_summary.docx
Entry  Thu May 2 14:00:36 2013, Koji, General, Configuration, test mass TR with Levin's approach thermo_refractive_1D_axisym_result.pdf
Entry  Mon Jan 22 21:13:25 2018, aaron, Mechanics, PonderSqueeze, tips from Shoaib 
    Reply  Mon Jan 29 23:02:13 2018, aaron, Mechanics, PonderSqueeze, tips from Shoaib 
Entry  Mon Jul 31 22:18:57 2017, rana, General, General, using more than 12 cores in matlab Screen_Shot_2017-07-31_at_10.11.35_PM.png
ELOG V3.1.3-