Message ID: 98
Entry time: Sat Aug 2 00:22:34 2014
In reply to: 97
|
Author: |
Sam Moore |
Type: |
Optics |
Category: |
General |
Subject: |
Finding the Right Meshing for the TIR cavity |
|
|
Quote: |
In this document, I try to identify I good mesh by comparing the numerical solution from that mesh with my analytical model. Since there are problems with carrying out the analytical calculation, it is still not entirely clear which mesh should be used.
|
I have refined the analytical calculation procedure, as outlined in this new document. The procedure indicates that the discrepancy between the analytical and numerical solutions are more likely attributed to meshing inaccuracies. |
|
|