40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  COMSOL elog  Not logged in ELOG logo
Message ID: 95     Entry time: Mon Jul 14 19:09:14 2014
Author: Sam Moore 
Type: Optics 
Category: General 
Subject: Using Heinert's Solution for Duan's Parameters 

 I have plotted Heinert's analytical solution for TR noise using Duan's parameters.  Since TO and TE noise can be found by simply rescaling TR noise, these have been included in the plot as well.  The solid curve represents the analytical solution, while the tick marks represent COMSOL's solution.  I have used COMSOL for both a 1D axisymmetric and a 3D model.  Since Duan's cylinder has a radius of 125 microns, but a length of 1 m, the meshing was difficult for the 3D model.  I ended up shortening the length of the cylinder, converting to the actual length when finally calculating the thermal noise.

Attachment 1: oneD_duanParams_residual-eps-converted-to.pdf  13 kB  | Show | Show all
Attachment 2: threeD_duanParams_residual-eps-converted-to.pdf  13 kB  | Show | Show all
ELOG V3.1.3-