Entry  Sat Jun 28 21:59:11 2014, Sam Moore, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 6_27_14.pdf
    Reply  Sun Jun 29 15:37:18 2014, Sam Moore, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 6_29_14.pdf
    Reply  Sun Jun 29 20:25:44 2014, Koji, Optics, General, Difficulty with the COMSOL stationary module; Test Cases 
Message ID: 89     Entry time: Sun Jun 29 15:37:18 2014     In reply to: 88
Author: Sam Moore 
Type: Optics 
Category: General 
Subject: Difficulty with the COMSOL stationary module; Test Cases 

Quote:

 Here, I describe some test cases to see if COMSOL's solutions are agreeing with some simple analytical solutions.  Right now, I have two plots showing COMSOL's solution and my analytical solution on separate plots.  I will be plotting there difference to see if they really match up.

 

 

 The following document shows the relative difference between these two plots.