Message ID: 34     Entry time: Wed Jun 26 13:52:06 2013
Author: Arnaldo Rodriguez 
Type: Optics 
Category: General 
Subject: Verifying Relative Error in Defocus for Regular and Manual-Loop Simulations 

To verify the validity of the solutions produced by the manual simulation, I've calculated the relative error between the results from the manual code and the results produced by COMSOL normally.

The plot for the relative error in the defocus at r = 0 and r = 54 mm is shown below, in the case where only the ring heater is turned on at a total power of 5 W.

Defocus_Error.png

The following indicates that the maximum error is less than 0.01% (in percent error format).

 

 

 

 

 