40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  COMSOL elog  Not logged in ELOG logo
Entry  Thu Feb 14 12:38:51 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-14_12-47-11.pngScreenshot_from_2019-02-14_15-07-40.pngScreenshot_from_2019-02-14_15-41-41.pnggraph.pdf
    Reply  Fri Feb 15 21:05:31 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-15_21-40-01.png
       Reply  Tue Feb 19 19:52:53 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-02-19_19-52-10.png
          Reply  Fri Mar 1 19:33:40 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-01_19-35-32.pngScreenshot_from_2019-03-01_19-36-02.pngScreenshot_from_2019-03-01_19-46-25.png
             Reply  Mon Mar 4 17:22:07 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-04_19-13-28.pngScreenshot_from_2019-03-04_19-14-41.pngScreenshot_from_2019-03-04_19-15-37.pngScreenshot_from_2019-03-04_19-15-56.png
                Reply  Wed Mar 6 09:51:18 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-06_09-31-24.png
                   Reply  Thu Mar 7 10:10:37 2019, Ching Pin, Mechanics, , comsol modelling Screenshot_from_2019-03-07_10-10-47.png
Message ID: 132     Entry time: Fri Feb 15 21:05:31 2019     In reply to: 131     Reply to this: 133
Author: Ching Pin 
Type: Mechanics 
Category:  
Subject: comsol modelling 

 

So I got the time dependence to work, but I'm not sure what went wrong in the first time anyways. I'll trying to get a sense of how long it takes for the temerature to semi-equlibrate, and coming to grips with comsol as a whole. There seems to be some inaccuracies when the timing increases, so I'm having to figure out how to increase accuracy without drastically increasing compute time. On the bright side, I switched the model to heating via deposited beam, for a more accurate model.

 

Attached is comsol's handling of a deposited beam modulated sinusoidally with a frequency of 0.1 Hz and screwing up badly.  Y axis is the average surface tempurature across the whole disc.

 

Attachment 1: Screenshot_from_2019-02-15_21-40-01.png  33 kB  | Show | Show all