It's a good idea, I'll check out her elogs and get it started tonight.
I found that I had the relative tolerance set too low (0.001, while the iterations were not converging further than 0.02 or so); I changed it to 0.1, which let me run over a few modes relatively quickly once I reduced the number of sections on the main part of the fiber to 10. This is not sufficient--at 600Hz the fiber looks completely jagged because the mesh is not fine enough, so using optimus will be necessary.
Quote: |
We could run the simulations on the 32 core machine in the 40m lab (optimus)? I think Mariia was running some of her studies on optimus, and even though we had some problems with the licensing initially, I think she resolved these and has detailed the procedure in her elogs...
|
|