Entry  Wed May 25 10:38:47 2022, aaron, Update, Laser, Teraxion laser testing 
    Reply  Wed May 25 15:39:55 2022, rana, Update, Laser, Teraxion laser testing 
Entry  Tue May 24 15:01:04 2022, shruti, DailyProgress, PSOMA, Cavity locking with Moku:Pro IMG_0010.PNGIMG_0011.PNGIMG_1701.png
    Reply  Wed May 25 11:49:36 2022, aaron, DailyProgress, PSOMA, Cavity locking with Moku:Pro IMG_2943.jpegIMG_2942.jpeg
       Reply  Wed May 25 12:18:34 2022, JC, DailyProgress, PSOMA, Cavity locking with Moku:Pro 
       Reply  Wed May 25 14:47:47 2022, rana, DailyProgress, PSOMA, Cavity locking with Moku:Pro 
Entry  Tue May 24 15:54:52 2022, rana, Lab Infrastructure, Lab Work, general cleanup 
    Reply  Wed May 25 10:32:19 2022, aaron, Lab Infrastructure, Lab Work, general cleanup 
Entry  Tue May 24 15:01:30 2022, Radhika, Misc, , Borrowed 2" Si wafer IMG_3489.jpeg
Entry  Thu May 19 10:16:04 2022, aaron, DailyProgress, Noise Budget, mode matching 
    Reply  Thu May 19 14:28:29 2022, shruti, DailyProgress, Noise Budget, mode matching, tfs, noise Spectra20220519.pdfPDHsignal.pdfLoopTFs.pdf
       Reply  Fri May 20 16:52:19 2022, rana, DailyProgress, Noise Budget, mode matching, tfs, noise 
          Reply  Mon May 23 10:47:56 2022, shruti, DailyProgress, Noise Budget, mode matching, tfs, noise LoopTFs.pdf
             Reply  Mon May 23 12:24:22 2022, shruti, DailyProgress, Noise Budget, mode matching 
             Reply  Mon May 23 13:06:33 2022, rana, DailyProgress, Control System, loop characterization 
Entry  Fri May 20 14:46:14 2022, JC, Update, Vacuum, Searching for Leaks on Statlin 
Entry  Thu May 5 17:01:40 2022, shruti, DailyProgress, Optics, Replaced the cavity input coupler with 99.994% R optic for higher finesse cavity 
    Reply  Tue May 10 14:05:56 2022, shruti, DailyProgress, Optics, Replaced the cavity input coupler with 99.994% R optic for higher finesse cavity 
       Reply  Tue May 10 14:56:42 2022, aaron, DailyProgress, Optics, measured scatter for a while, but here's the cavity alignment procedure trim.5617A4E4-1A7A-49C2-B66B-9D65F3013712.MOV
          Reply  Wed May 11 12:42:04 2022, shruti, DailyProgress, PSOMA, aligning IMG_D3C4C21EF227-1.jpeg
             Reply  Wed May 11 14:11:15 2022, aaron, DailyProgress, PSOMA, aligning 
                Reply  Thu May 12 11:22:44 2022, aaron, DailyProgress, PSOMA, aligning WorkNB_Y3Q3_2.pdf
                   Reply  Fri May 13 15:02:29 2022, rana, DailyProgress, PSOMA, new PSOMA cavity configuration 
                      Reply  Tue May 17 14:28:09 2022, aaron, DailyProgress, PSOMA, new PSOMA cavity configuration 
                         Reply  Wed May 18 11:19:34 2022, shruti, DailyProgress, PSOMA, new PSOMA cavity configuration 
                            Reply  Wed May 18 12:56:35 2022, aaron, DailyProgress, PSOMA, new PSOMA cavity configuration 
                         Reply  Wed May 18 13:39:00 2022, shruti, DailyProgress, PSOMA, new PSOMA cavity configuration Mismatch.pdfBeamRadius.pdfMMsol1.pdfMMsol2.pdf
                            Reply  Wed May 18 19:32:57 2022, aaron, DailyProgress, PSOMA, new PSOMA cavity configuration 
                               Reply  Thu May 19 10:32:35 2022, rana, DailyProgress, PSOMA, new PSOMA cavity configuration 
Entry  Fri May 13 12:57:30 2022, aaron, Lab Infrastructure, Vacuum, leak checking cryo cantilevers vacuum 
Entry  Tue May 3 09:51:42 2022, shruti, DailyProgress, PSOMA, loop TFs and noise spectra LoopModel.pdfNoise.pdfSpectra20220502.pdfNoise.pdfnoisespectra1.pdf
    Reply  Tue May 3 15:34:15 2022, aaron, DailyProgress, PSOMA, loop TFs and noise spectra CalibratedNoiseBudget.pdfCalibratedNoiseBudget.pdf
       Reply  Wed May 4 15:52:56 2022, shruti , DailyProgress, PSOMA, loop TFs and noise spectra 1DFC2C2A-ABB4-41ED-9F2C-7A667BAA4B96.pngLoopTFs.pdfCalibratedNoiseBudget.pdfLoopTFs.pdf
          Reply  Thu May 5 17:09:06 2022, aaron , DailyProgress, PSOMA, loop TFs and noise spectra LB_CTRL_comparison.pdfLB_CTRL_comparison.pdf
    Reply  Thu May 5 14:09:42 2022, aaron, DailyProgress, PSOMA, loop TFs and noise spectra 
Entry  Tue May 3 16:34:19 2022, Chris, DailyProgress, PSOMA, current driver connections and cantilever acoustic damping 6x
Entry  Thu Apr 28 11:19:24 2022, shruti, Update, PSOMA, Switch current driver to custom low noise 
    Reply  Thu Apr 28 14:44:28 2022, aaron, Update, PSOMA, Switch current driver to custom low noise fitted_full.pdfCalibratedNoiseBudget.pdf
       Reply  Fri Apr 29 11:21:51 2022, shruti, Update, PSOMA, Switch current driver to custom low noise CalibratedNoiseBudget.pdflaser_noise_comparison.pdf
Entry  Thu Apr 28 06:12:14 2022, Chris, Electronics, PSOMA, Current driver repair/upgrade knobs.pdfspectra.pdfAG4395A_25-04-2022_170840.pdfdata.zip
Entry  Mon Apr 11 16:30:12 2022, aaron, Noise Hunting, Noise Budget, PSOMA noise budget CalibratedNoiseBudget20220411.pdf
    Reply  Wed Apr 13 11:10:28 2022, aaron, Noise Hunting, Noise Budget, PSOMA noise budget CalibratedNoiseBudget20220411.pdf
       Reply  Thu Apr 14 13:45:08 2022, aaron, Noise Hunting, Noise Budget, laser frequency noise measurement CalibratedNoiseBudget.pdfIMG_16928781279A-1.JPEG
          Reply  Fri Apr 15 16:25:00 2022, rana, Noise Hunting, Noise Budget, laser frequency noise measurement 
          Reply  Tue Apr 19 14:50:00 2022, aaron, Noise Hunting, Noise Budget, photodiode dark noise measurement 
             Reply  Wed Apr 20 15:48:07 2022, aaron, Noise Hunting, Noise Budget, calibrating PDH error signal 9B21DA6F-14BA-453D-93BB-C6C8803CBCA0.jpeg
                Reply  Mon Apr 25 13:54:03 2022, shruti, Noise Hunting, Noise Budget, calibrating PDH error signal IMG_1620.pdfIMG_1619.pdfIMG_1622.pdfIMG_1623.pdf
                   Reply  Tue Apr 26 16:18:11 2022, aaron, Noise Hunting, Noise Budget, calibrating PDH error signal fitted_full.pdf
Entry  Tue Apr 26 14:28:51 2022, aaron, Things to Buy, Optics, high reflectors in lab 
Entry  Tue Apr 12 15:00:39 2022, Ian MacMillan, Misc, Equipment Loan, Accelerometer/seismometer loan Wilcoxon 731A IMG_1558.jpeg
    Reply  Thu Apr 21 18:13:36 2022, Ian MacMillan, Misc, Equipment Loan, Accelerometer/seismometer loan Wilcoxon 731A 
Entry  Wed Apr 20 14:27:41 2022, aaron, Lab Infrastructure, General, starting up after power outage Screenshot_from_2022-04-20_14-41-11.png
Entry  Tue Sep 28 15:47:39 2021, aaron, Lab Infrastructure, PSOMA, PSOMA table enclosure 
    Reply  Wed Sep 29 09:57:50 2021, aaron, Lab Infrastructure, PSOMA, PSOMA table enclosure assembly 
       Reply  Thu Oct 14 09:02:57 2021, aaron, Lab Infrastructure, PSOMA, PSOMA table enclosure assembly 
          Reply  Tue Oct 19 10:45:08 2021, aaron, Lab Infrastructure, PSOMA, PSOMA table enclosure assembly 
             Reply  Tue Mar 1 17:08:47 2022, shruti, Lab Infrastructure, PSOMA, PSOMA table enclosure assembly WorkNB_Y3Q2.pdf
                Reply  Tue Apr 19 12:07:46 2022, shruti, Lab Infrastructure, PSOMA, PSOMA table enclosure assembly 
Entry  Tue Apr 12 12:16:58 2022, Aaron, DailyProgress, Si fab, Basic cantilever scribe and break 51649EDB-A7BC-49DC-AD53-F95345413D0E.jpeg2741BA36-BF23-4289-9BBC-6054A10A3ECC.jpeg
Entry  Tue Mar 29 16:03:40 2022, shruti, DailyProgress, PSOMA, Mixing signal and pump (north and south) addpump_.pdf
    Reply  Wed Mar 30 16:18:58 2022, shruti, DailyProgress, PSOMA, Mixing signal and pump (north and south) 
Entry  Tue Mar 8 13:45:20 2022, aaron, DailyProgress, Electronics, second PDH box and EOM 
    Reply  Wed Mar 9 14:20:26 2022, aaron, DailyProgress, Electronics, updates to fiber patch cables, realignment, N laser in path, relock 
       Reply  Thu Mar 10 13:43:20 2022, aaron, Misc, Laser, mode matching and slow servo, three corner hat revisited Screenshot_from_2022-03-10_14-26-10.png
Entry  Thu Mar 3 13:09:25 2022, aaron, Noise Hunting, Laser, some noise budgets maybe 
Entry  Wed Feb 23 17:23:35 2022, Chris, Electronics, PSOMA, current driver status coarseknob.png
Entry  Thu Feb 10 14:12:56 2022, aaron, DailyProgress, Laser, laser transfer function 
    Reply  Tue Feb 22 11:51:55 2022, shruti, Noise Hunting, Laser, laser transfer function and frequency noise LaserTF.pdfLaserFreqNoise.pdf
Entry  Fri Feb 18 10:43:18 2022, aaron, DailyProgress, PSOMA, enclosure rails, laser noise 
Entry  Fri Feb 18 10:40:04 2022, aaron, HowTo, Electronics, how to Moku on wifi 
Entry  Thu Jan 27 14:40:19 2022, shruti, Update, Noise Budget, Measurement and calibration of noise spectra Spectra20220127.pdfCalibratedNoiseSpectra20220127.pdfCavityMeasurements.pdf
    Reply  Wed Feb 2 11:08:47 2022, shruti, Update, Noise Budget, Measurement and calibration of noise spectra OLTF_20220201.pdfCalibratedNoiseSpectra.pdfCalibratedNoiseSpectra20220127_corrected.pdfattn10dB.jpegFilterTF.pdf
       Reply  Mon Feb 7 11:55:07 2022, shruti, Update, Noise Budget, Updated pomona filter, loop model filter.jpegFilterTF.pdfLoopModel.pdf
          Reply  Wed Feb 9 16:25:54 2022, rana, Update, Noise Budget, Updated pomona filter, loop model 
             Reply  Tue Feb 15 11:21:18 2022, shruti, Update, Noise Budget, Updated loop model LoopModel.pdfLB_meas_setup.jpeg
                Reply  Tue Feb 15 16:56:50 2022, rana, Update, Noise Budget, Updated loop model 
Entry  Mon Dec 27 05:38:56 2021, rana, Update, Control System, cavity locking loop shape 
    Reply  Mon Jan 24 10:24:49 2022, shruti, Update, Control System, cavity locking loop shape OLTF_fit.pdf
       Reply  Wed Jan 26 17:28:53 2022, shruti, Update, Control System, cavity locking loop shape ctrl_pdh_5kHz_Screenshot.pngctrl_pdh_10kHz_Screenshot.pngscope_red.pdffilter_red.pngctrl_pdh_100kHz_Screenshot.png
          Reply  Mon Jan 31 19:03:43 2022, shruti, Update, Control System, cavity locking loop shape - pomona box TF FilterTF.pdfdata_and_analysis.zip
Entry  Wed Jan 26 17:55:52 2022, Stephen, Summary, PSOMA, Calculating LN2 requirements for PSOMA Cryostat 
    Reply  Fri Jan 28 10:38:21 2022, rana, Summary, PSOMA, Calculating LN2 requirements for PSOMA Cryostat 
Entry  Mon Jan 17 19:15:37 2022, rana, Computing, DAQ, auto backup to LDAS failing 
    Reply  Mon Jan 24 12:37:27 2022, Chris, Computing, DAQ, auto backup to LDAS failing 
       Reply  Thu Jan 27 21:24:33 2022, Chris, Computing, DAQ, auto backup to LDAS failing 
Entry  Wed Jan 5 15:08:33 2022, Radhika, Aaron, DailyProgress, PSOMA, PSOMA cryostat model PSOMAstat_cooldown_model.pdf
Entry  Tue Dec 14 14:10:36 2021, aaron, Summary, PSOMA, PSOMA calibration parameters, minor modifications 
    Reply  Fri Dec 17 12:46:41 2021, aaron, Summary, PSOMA, PSOMA calibration parameters, minor modifications 
       Reply  Fri Dec 17 18:46:55 2021, aaron, Summary, PSOMA, PSOMA calibration parameters, minor modifications 
Entry  Thu Dec 16 17:07:24 2021, aaron, DailyProgress, Laser, beat note setup loose.jpgclamped.jpg
Entry  Tue Dec 7 11:11:37 2021, aaron, Noise Hunting, Laser, finding a stable lock 
    Reply  Tue Dec 7 11:44:27 2021, rana, Noise Hunting, Laser, finding a stable lock 
       Reply  Fri Dec 10 11:30:44 2021, shruti, Update, Laser, Beat between the lasers beat.pdffiberbox.pdf
Entry  Wed Oct 20 11:31:06 2021, shruti, Update, PSOMA, Towards locking PSOMA with cantilever 
    Reply  Tue Oct 26 10:01:54 2021, shruti, Update, PSOMA, Towards locking PSOMA with cantilever TiltedCantilever.pdfcantileversurface.pdfclampsurface.pdf
       Reply  Thu Nov 18 11:09:24 2021, shruti, Update, PSOMA, Towards locking PSOMA with cantilever CavitySetup.pdfGeometry01.jpeg
          Reply  Wed Dec 1 13:21:54 2021, shruti, Update, PSOMA, Towards locking PSOMA with cantilever IMG_1250.pngIMG_1252.pngIMG_1251.pngIMG_1253.pngIMG_1254.png
             Reply  Thu Dec 2 13:40:57 2021, shruti, Update, PSOMA, Progress and cavity parameters/ lock parameters 
Entry  Wed Nov 10 10:45:22 2021, aaron, Update, Si fab, KOH etching 
Entry  Tue Nov 9 19:01:43 2021, aaron, Update, Laser, fiber components to fiber box IMG_2187.jpgIMG_2184.jpg
Entry  Wed Sep 29 10:27:50 2021, Chris, Computing, stuff happens, backups 
Entry  Wed Sep 15 16:42:31 2021, Radhika, Misc, Equipment Loan, Borrowing lenses for DOPO lab IMG_2532.jpeg
    Reply  Wed Sep 22 11:12:12 2021, Paco, Misc, Equipment Loan, Return lens 
Entry  Mon Sep 20 14:08:18 2021, shruti, Update, PSOMA, in-air cantilever cavity 6x
    Reply  Tue Sep 21 10:53:01 2021, shruti, DailyProgress, PSOMA, in-air cantilever cavity 
Entry  Mon Sep 20 16:31:37 2021, shruti, Noise Hunting, PSOMA, tfs and noise before changing out optic->cantilever OLTF.pdfOLTF_fit.pdfData20210915.zip
Entry  Wed Sep 15 16:45:54 2021, aaron, DailyProgress, Optics, cantilever clamped 6x
    Reply  Thu Sep 16 19:15:31 2021, aaron, DailyProgress, stuff happens, another mirror bonded to another cantilever 
Entry  Tue Sep 14 16:43:11 2021, shruti, Update, Optics, Debonding and bonding mirrors to silicon cantilevers varnishdissolve.pdf
Entry  Wed Sep 8 09:11:43 2021, Radhika, Misc, Equipment Loan, Borrowed 1550nm AOM IMG_2518.jpegIMG_2517.jpeg
Entry  Tue Sep 7 10:01:39 2021, shruti, Update, PSOMA, attempt at bonding, another broken cantilever... CAA96DEB-236A-4BD4-B196-8985374562AB.jpeg03813DE5-AC9D-4958-A203-60B0C8751BCC.jpegCA57BFB3-9A8C-4AAF-ADA0-F11F507D8464.jpegB458F0DC-8BD8-422B-9F21-88CF18163C0B.jpeg
Entry  Fri Apr 30 12:07:25 2021, aaron, DailyProgress, Laser, marconi locking 252D9563-0122-418B-9B97-29D44FEF83E9.jpeg
    Reply  Fri Apr 30 15:15:33 2021, rana, DailyProgress, Laser, marconi locking 
       Reply  Mon May 3 23:28:56 2021, rana, DailyProgress, Laser, delay line frequency discriminator DFD.jpg
          Reply  Wed May 5 11:54:19 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 9x
             Reply  Wed May 5 22:21:17 2021, rana, DailyProgress, General, delay line frequency discriminator 
             Reply  Thu May 6 10:48:40 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 3EFFFA27-AAF6-434F-A1AB-FE7C657A464C.jpegDL_3CH.pdf
                Reply  Tue May 11 14:37:48 2021, aaron, DailyProgress, Laser, delay line frequency discriminator, current noise measurement 
                   Reply  Wed May 12 15:35:09 2021, aaron, DailyProgress, Laser, delay line in a box 69A8E6A2-7F85-464E-BDAA-8C6BBD2910B5.jpeg1D05A31E-7DBC-448B-A2F4-A8805EFAC393.jpeg25C2DD1E-7776-491E-BBCE-5F2D1EA935E3.jpeg
                   Reply  Wed May 12 16:52:08 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 3878D102-C5BB-46AE-B90B-540CFDE3100B.jpegSPSR785_NX_12-05-2021_173959.pdfSPSR785_SX_12-05-2021_183434.pdfSPSR785_NS_12-05-2021_191513.pdf
                      Reply  Thu May 13 16:31:40 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 6x
                         Reply  Thu May 13 19:09:16 2021, rana, DailyProgress, Laser, delay line frequency discriminator 
                         Reply  Fri May 14 18:43:25 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 994ECC7F-C5FE-4E7B-8F19-B1C118DCE6CE.png
                            Reply  Thu May 20 12:50:56 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 
                               Reply  Fri May 21 14:15:21 2021, aaron, DailyProgress, Laser, current noise of custom current drivers 5012D147-8B13-478C-BB83-57A71A2B304A.jpeg467DEC59-01B1-40CD-9F4E-4D9D87183A78.jpegABC2A51B-6726-4F9C-AD88-551ED7C90EEF.jpeg
                               Reply  Tue Aug 17 14:04:27 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 3A1E242C-F4F6-4A87-B2E8-E74839BE542C.jpeg
                                  Reply  Wed Aug 18 09:55:13 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 0A96102F-5465-456B-93BF-E2B9D4A7E96C.jpegtrim.2553D656-98A0-442D-9185-4C5252B2B727.MOVtrim.787F04FC-8DED-4501-B67D-FF98EC5D5D56.MOV
                                     Reply  Thu Aug 19 14:21:35 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 007FC2D7-F29B-4636-9CE7-04CBC3B789F7.jpeg1F1E68F0-199F-4E1C-B909-883A521E06CF.jpegScreenshot_from_2021-08-19_17-53-58.png
                                        Reply  Fri Aug 20 11:03:44 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 30A43669-5DFF-400A-BEB4-7EF71BBAE1A6.jpegA3BF5DA5-32E5-42A5-A1D8-9270C3D88518.pngScreenshot_from_2021-08-20_16-11-26.pngScreenshot_from_2021-08-20_16-20-48.png
                                           Reply  Mon Aug 23 13:38:57 2021, aaron, DailyProgress, Laser, delay line frequency discriminator Screenshot_from_2021-08-23_16-42-48.png
                                              Reply  Tue Aug 24 16:44:39 2021, aaron, DailyProgress, Laser, delay line frequency discriminator beats_regions.pdfTeraxion_noise.pdfEW_timeseries.pdf
                                                 Reply  Thu Aug 26 11:58:50 2021, aaron, DailyProgress, Laser, delay line frequency discriminator 9x
                                                    Reply  Fri Aug 27 15:27:38 2021, rana, DailyProgress, Laser, delay line frequency discriminator 
                                                    Reply  Tue Aug 31 15:14:28 2021, aaron, DailyProgress, Laser, quieting the Rio W and Teraxion beat notes, but not much help beats_regions_base2.pdfbeats_regions_base2.pdfTeraxion_noise_base2.jpgDLFD_foam.pdf
                                                       Reply  Wed Sep 1 12:20:18 2021, rana, DailyProgress, Laser, quieting the Rio W and Teraxion beat notes, but not much help 
                                     Reply  Thu Aug 19 16:32:47 2021, rana, DailyProgress, Laser, delay line frequency discriminator 
       Reply  Tue May 4 10:50:22 2021, aaron, DailyProgress, Laser, marconi locking 6DC5CB12-BCDF-4550-AFB8-42D3DC354AED.jpegSPSR785_04-05-2021_152326.pdf
          Reply  Wed May 5 00:27:10 2021, rana, DailyProgress, Laser, marconi locking 
Entry  Tue Aug 31 13:23:05 2021, aaron, DailyProgress, Suspension, clamped cantilever 
Entry  Mon Aug 30 14:06:00 2021, aaron, Notes, Si fab, Cantilever fabrication process 
Entry  Thu Aug 26 19:40:06 2021, rana, Noise Hunting, Laser, high frequency frequency noise measurement w/ DFD and new low pass TeraRIOEast_beat_Screenshot.pngPlanex-Beatnote-ASD.pdfDFD-Discriminant-Cal.pdf
Entry  Tue Aug 24 16:25:17 2021, rana, Electronics, General, app note on mixers vs phase detectors 
Entry  Mon Aug 23 14:35:36 2021, shruti, DailyProgress, PSOMA, re-aligning 
Entry  Tue Jul 13 12:00:36 2021, aaron, Update, Control System, venting cantilevers cryostat EA078826-F058-4029-BE52-0A0534AF5180.jpegScreenshot_from_2021-07-13_16-25-28.png
    Reply  Tue Aug 10 17:23:39 2021, aaron, DailyProgress, Vacuum, venting cantilevers cryostat 10CC78ED-EC51-4F10-8CBB-9ED236746501.jpegScreenshot_from_2021-08-10_19-13-12.pngScreenshot_from_2021-08-10_19-14-19.png
       Reply  Wed Aug 11 13:21:23 2021, aaron, DailyProgress, Vacuum, venting cantilevers cryostat Screenshot_from_2021-08-12_14-57-42.png
          Reply  Thu Aug 12 15:03:32 2021, shruti, DailyProgress, Vacuum, venting cantilevers cryostat Screenshot_from_2021-08-12_17-51-06.png885A9694-996E-499E-BDCC-FB550338561F.jpeg
             Reply  Mon Aug 16 18:48:37 2021, rana, DailyProgress, Vacuum, venting cantilevers cryostat 
Entry  Thu Aug 5 19:36:43 2021, aaron, Lab Infrastructure, Lab Work, preparing for lab rearrangement 
    Reply  Tue Aug 10 17:39:40 2021, aaron, Lab Infrastructure, Lab Work, preparing for lab rearrangement Screenshot_from_2021-08-10_19-01-13.png
       Reply  Wed Aug 11 16:09:29 2021, aaron, Lab Infrastructure, Lab Work, preparing for lab rearrangement 
Entry  Thu Aug 5 16:26:26 2021, aaron, DailyProgress, Laser, Temperature-to-frequency,  Screenshot_from_2021-08-05_16-25-38.pngScreenshot_from_2021-08-05_16-25-54.png
Entry  Tue Jun 29 14:13:53 2021, aaron, DailyProgress, Noise Budget, Calibrating PSOMA noise budget 8CD3FEA8-9EE1-4728-8639-A69206A8D098.png
    Reply  Wed Jun 30 14:38:49 2021, aaron, DailyProgress, Noise Budget, Calibrating PSOMA noise budget 210630_PDH_fit.pdf
       Reply  Thu Jul 1 13:39:12 2021, aaron, DailyProgress, Noise Budget, Calibrating PSOMA noise budget 
          Reply  Fri Jul 2 11:29:52 2021, shruti, DailyProgress, Noise Budget, Calibrating PSOMA noise budget 7x
          Reply  Tue Jul 6 14:39:49 2021, shruti, DailyProgress, Noise Budget, Calibrating PSOMA noise budget OLTF_fit.pdfNoise.pdfinitial_calibration_data.zip
             Reply  Thu Jul 8 09:50:41 2021, aaron, DailyProgress, Noise Budget, PSOMA noise budget, does it make sense? Noise.pdfOLTF_fit.pdf
    Reply  Wed Jun 30 17:26:42 2021, aaron, DailyProgress, Noise Budget, Calibrating PSOMA noise budget 6AC149C5-9C0F-42E7-8DE6-AA1F5FB8D9AF.jpeg
       Reply  Fri Jul 30 16:55:38 2021, rana, Electronics, Laser, Delay Line Freq Discriminators 
Entry  Tue Jul 20 19:15:43 2021, aaron, DailyProgress, Lab Work, fibers inspection 
Entry  Thu Jul 15 17:22:03 2021, aaron, DailyProgress, Lab Work, lab cleanup 
Entry  Mon Jul 12 15:34:30 2021, aaron, Lab Infrastructure, DAQ, temperature trend, cominaux apt Screenshot_from_2021-07-12_15-51-07.pngScreenshot_from_2021-07-13_10-52-50.png
Entry  Mon Jul 12 14:28:38 2021, aaron, Electronics, Lab Work, no noisy pickoffs for PDH signals 321F64CD-6EDA-4E4F-B9D5-0C403286E2AF.jpeg
Entry  Thu Jul 8 14:51:08 2021, shruti, DailyProgress, Lab Work, Setting changes 
    Reply  Thu Jul 8 19:10:59 2021, aaron, DailyProgress, Lab Work, Setting changes 
Entry  Tue Jun 22 14:35:40 2021, aaron, shruti, DailyProgress, Control System, slow temperature control 7x
    Reply  Wed Jun 23 17:53:21 2021, aaron, DailyProgress, Control System, slow temperature control 
       Reply  Thu Jun 24 12:26:56 2021, shruti, DailyProgress, Control System, slow temperature control 
          Reply  Thu Jun 24 14:37:12 2021, aaron, DailyProgress, Control System, slow temperature control, more transfer functions 
             Reply  Mon Jun 28 10:12:28 2021, shruti, DailyProgress, Control System, glitches, transfer function glitches.pngOLTF.pdfSetup.pdfData.zip
                Reply  Mon Jun 28 13:16:07 2021, aaron, DailyProgress, Control System, glitches 
                   Reply  Tue Jun 29 08:53:02 2021, Chris, HowTo, Control System, acquiring slow channels 
Entry  Mon Jun 28 13:54:46 2021, aaron, Notes, Laser, phase noise in diode lasers 
Entry  Fri Jun 11 08:58:44 2021, shruti, DailyProgress, PSOMA, Spurious peaks 6x
    Reply  Fri Jun 11 17:08:20 2021, rana, DailyProgress, PSOMA, Spurious peaks 
       Reply  Wed Jun 16 10:29:58 2021, shruti, DailyProgress, PSOMA, Investigating the peaks SameGainASD.pdfDiffGainSR560.pdf
          Reply  Fri Jun 18 10:42:08 2021, aaron, DailyProgress, PSOMA, Investigating the peaks B09D5E30-08A4-45B1-934C-7D6E84FDBAAB.jpeg5368BBE2-F9C7-4DBC-B098-05363DB8FD20.png1A231013-D1A3-49BF-A5E7-0B4D9238E195.png2B9714F6-0367-44F2-8E53-AF6E2C9ADFC0.png
             Reply  Mon Jun 21 13:54:08 2021, shruti, DailyProgress, PSOMA, Open Loop Transfer Functions 6x
             Reply  Mon Jun 21 15:34:09 2021, aaron, Electronics, Lab Work, swapping mixer A172449C-4B5D-47C1-B7FC-014B6CC28471.jpeg796CBB56-3AA5-48D6-A344-F8239D9E605D.png
                Reply  Wed Jun 23 11:36:49 2021, shruti, Electronics, Lab Work, swapping mixer MixerandLPFupdate.pdf
Entry  Tue Jun 15 16:33:35 2021, aaron, DailyProgress, Lab Work, slow controls 
    Reply  Thu Jun 17 10:35:42 2021, shruti, DailyProgress, , Temp tune not absolute Temp_Tune.pdf
       Reply  Thu Jun 17 12:14:33 2021, aaron, DailyProgress, Lab Work, Temp tune not absolute Screenshot_from_2021-06-17_12-54-07.png
Entry  Wed Jun 2 15:42:20 2021, aaron, Lab Infrastructure, Drawings, new lab layouts Canvas_1.pdfCanvas_2.pdf
    Reply  Tue Jun 15 14:59:29 2021, shruti, Lab Infrastructure, Drawings, new lab layouts lab_layout_plan.pdf
Entry  Tue Jun 8 10:08:56 2021, aaron, DailyProgress, Noise Budget, PDH spectrum, transfer function Screenshot_from_2021-06-08_13-05-16.png
Entry  Mon Jun 7 13:23:33 2021, aaron, DailyProgress, Lab Work, monitoring PDH signal on cymac status.png
Entry  Thu Jun 3 15:02:13 2021, aaron, Computing, stuff happens, restart rts-edc 
Entry  Thu May 20 13:32:11 2021, aaron, Computing, stuff happens, where's the x1cry medm master? 
Entry  Fri May 14 13:27:42 2021, aaron, Lab Infrastructure, General, what's up with nodus proxy errors? 
Entry  Tue May 11 13:13:46 2021, aaron, Lab Infrastructure, General, property tags IMG_0589.jpegIMG_0586.jpegIMG_0585.jpegIMG_0584.jpegIMG_0583.jpeg
Entry  Tue May 11 13:10:27 2021, aaron, Lab Infrastructure, Purchases, confirming enclosure dimensions 
Entry  Mon May 10 15:48:12 2021, aaron, Lab Infrastructure, DAQ, particle counter is logging Screen_Shot_2021-05-10_at_16.03.21.png
Entry  Tue Apr 27 19:37:49 2021, shruti, Update, PSOMA, PDH error signal PDHerrorsig.mp4BeatNX20210427.pdfIMG_0215.jpgPDH.pdf
    Reply  Tue Apr 27 20:24:18 2021, rana, Update, PSOMA, PDH error signal 
    Reply  Fri May 7 13:15:07 2021, shruti, Update, PSOMA, Cavity locking, feedback to laser IMG_0217.pdf
       Reply  Mon May 10 10:20:54 2021, shruti, Update, PSOMA, Cavity locking, feedback to laser ControlSigLockedCav.pdfControlSigCavLocked2.pdf
          Reply  Mon May 10 15:41:41 2021, rana, Update, PSOMA, Cavity locking, feedback to laser 
Entry  Thu Apr 29 17:26:24 2021, aaron, Things to Buy, General, fiber box 
Entry  Wed Apr 28 09:46:12 2021, rana, Noise Hunting, Laser, problems with the phasemeter 
    Reply  Wed Apr 28 12:09:28 2021, aaron, Noise Hunting, Laser, phasemeter drift 11x
       Reply  Wed Apr 28 15:26:10 2021, rana, Noise Hunting, Laser, phasemeter drift 
       Reply  Thu Apr 29 17:25:55 2021, aaron, Noise Hunting, Laser, phasemeter drift D520B366-A9B5-4E80-BE34-40A5D790AD8D.jpegITC510.pdf
Entry  Tue Apr 27 18:08:05 2021, rana, Computing, General, caps lock -> ctrl 
    Reply  Wed Apr 28 10:29:29 2021, aaron, Computing, General, caps lock -> ctrl 
       Reply  Thu Apr 29 13:01:13 2021, rana, Computing, General, caps lock -> ctrl 
Entry  Tue Apr 20 19:09:37 2021, aaron, Update, Laser, measuring NX beat note 
    Reply  Wed Apr 21 15:26:36 2021, aaron, Update, Laser, measuring beat notes 
       Reply  Thu Apr 22 12:51:15 2021, aaron, Update, Laser, measuring beat notes 
          Reply  Mon Apr 26 20:13:24 2021, aaron, Update, Laser, measuring beat notes beat_notes.pdflaser_ASD.pdf
    Reply  Tue Apr 27 14:15:40 2021, aaron, Update, Laser, measuring NX beat note 
       Reply  Tue Apr 27 20:19:09 2021, rana, Update, Laser, laptop broken 
Entry  Fri Mar 5 14:36:00 2021, aaron, DailyProgress, Lab Work, learned something about measuring clocks Screenshot_from_2021-03-05_15-14-24.png8B3029C0-A1D3-4044-B238-68D545187BE5.jpeg
    Reply  Mon Mar 8 12:11:52 2021, aaron, DailyProgress, Lab Work, allan covariance 9EEB7450-A584-4085-8F4F-0F70F164AF13.jpeg
       Reply  Thu Apr 15 16:28:20 2021, shruti, Update, PSOMA, setup to do both locking and incoherent 3CH table_setup.pdf
          Reply  Thu Apr 22 20:25:49 2021, shruti, Update, PSOMA, setup to do both locking and incoherent 3CH Setup20210426.pdf
Entry  Thu Apr 22 10:43:25 2021, shruti, Update, PSOMA, Cavity aligned and resonant flashes observed Flashes.mp4
    Reply  Thu Apr 22 12:56:18 2021, rana, Update, PSOMA, Cavity aligned and resonant flashes observed 
Entry  Wed Feb 17 11:56:20 2021, shruti, Computing, PSOMA, Cavity design Optimized_incl_sidebands_old_2m_33_5MHz.pdfUnoptimized.pdf
    Reply  Thu Feb 25 22:34:48 2021, shruti, Computing, PSOMA, Cavity design CavityDesignPossibility1.pdfCavityDesignPossibility2.pdf
       Reply  Thu Mar 18 10:08:40 2021, shruti, Update, PSOMA, Cavity design CavityDesign_L40cm_R2m.pdfMM_L40cm_R2m_RA.pdfNorth_corrected.pdfSourth_corrected.pdf
          Reply  Wed Apr 21 09:52:11 2021, shruti, Update, PSOMA, Cavity design Mode_match1.pdfRoC_1m_lrt_582mm.pdfTolerance.pdfMode_match2.pdf
Entry  Thu Apr 8 22:47:03 2021, shruti, DailyProgress, PSOMA, Cavity locking and temperature scan TemptuneCalc.pdfUntitled.png
    Reply  Wed Apr 14 17:15:23 2021, shruti, DailyProgress, PSOMA, RoC measurement RoCis0_4mConvex.pdf20210412.ziptest_roc.m
       Reply  Thu Apr 15 19:24:35 2021, shruti, DailyProgress, PSOMA, RoC measurement RoC.pdftest_roc.mconcave_beamprofs.zip
Entry  Tue Apr 13 11:31:37 2021, aaron, DailyProgress, General, some parts to W bridge 
Entry  Fri Mar 19 11:08:15 2021, aaron, DailyProgress, Lab Work,  Screenshot_from_2021-03-19_11-09-04.pnglasers_ASD.pdf
    Reply  Sun Mar 21 12:52:43 2021, rana, HowTo, Noise Budget, phase noise 
    Reply  Mon Mar 22 12:05:41 2021, rana, DailyProgress, Lab Work,  
       Reply  Mon Mar 22 13:28:32 2021, aaron, DailyProgress, Lab Work, lab temperature logging Screenshot_from_2021-03-22_14-08-10.png
          Reply  Mon Mar 22 21:41:09 2021, Chris, DailyProgress, Lab Work, lab temperature logging 
             Reply  Tue Mar 23 11:07:56 2021, shruti, DailyProgress, Lab Work, lab temperature logging Screenshot_from_2021-03-23_11-06-46.pngScreenshot_from_2021-03-23_11-04-15.png
    Reply  Tue Mar 30 15:00:56 2021, aaron, HowTo, General, Where is three corner hat data? Cryo repos? 
Entry  Thu Mar 18 18:21:36 2021, aaron, DailyProgress, Laser, 3CH setup 
Entry  Thu Mar 18 16:44:33 2021, shruti, DailyProgress, PSOMA, cavity alignment, RF oscillator power and frequency MokuSpectrumAnalyzerData_20210318_162955_Screenshot.pngMokuSpectrumAnalyzerData_20210318_162552_Screenshot.pngMokuSpectrumAnalyzerData_20210318_162358_Screenshot.png
Entry  Wed Mar 17 12:55:42 2021, aaron, DailyProgress, stuff happens, not much 
Entry  Fri Feb 19 14:14:29 2021, shruti, Notes, Laser, Power vs. Temperature plots for Rio PLANEX PvsT_20210219.zipPvsT.pdf
    Reply  Fri Feb 19 14:46:04 2021, rana, Notes, Laser, Power vs. Temperature plots for Rio PLANEX 
       Reply  Fri Feb 19 22:01:44 2021, aaron, Notes, Laser, Power vs. Temperature plots for Rio PLANEX 
    Reply  Mon Mar 15 12:11:51 2021, shruti, Notes, Laser, Power vs. Temperature plots for Rio PLANEX South.pdfRtoT.pdfSouthData.zip
Entry  Thu Mar 4 13:37:14 2021, aaron, DailyProgress, Electronics, PSOMA S mA->MHz, ITC 502 current noise mA_to_MHz.pdf002F0263-0615-4566-9192-F57A14C8B543.jpegITC502_ASD.pdf
    Reply  Sun Mar 7 19:32:32 2021, rana, DailyProgress, Electronics, PSOMA S mA->MHz, ITC 502 current noise 
    Reply  Wed Mar 10 16:03:19 2021, aaron, DailyProgress, Electronics, current noise 
       Reply  Thu Mar 11 13:56:47 2021, aaron, DailyProgress, Electronics, current noise wire_shelf_5.jpg
Entry  Tue Feb 2 09:52:19 2021, aaron, Computing, DAQ, cymac to Debian buster 
    Reply  Wed Feb 3 08:23:12 2021, Chris, Computing, DAQ, cymac to Debian buster 
       Reply  Tue Feb 9 16:33:31 2021, aaron, Computing, DAQ, cymac to Debian buster 
          Reply  Thu Feb 11 18:51:39 2021, aaron, Computing, DAQ, cymac to Debian buster Screen_Shot_2021-02-11_at_19.27.21.png
             Reply  Mon Feb 15 18:25:19 2021, Chris, Computing, DAQ, cymac to Debian buster 
                Reply  Tue Feb 16 14:29:04 2021, aaron, Computing, DAQ, cymac to Debian buster 55B5D301-4243-45DA-9B03-45EF87B2A684.jpeg4C7FE7DC-E8A0-4770-9A49-14EB491F76E2.jpeg13D67AB6-5A77-4C94-A2A4-FE7FDF065B01.jpegC84B3054-269B-4969-817F-1429BB671C7A.jpeg
                   Reply  Thu Feb 18 16:16:38 2021, aaron, Computing, DAQ, cymac to Debian buster 15A01777-A1C5-4710-8180-28C8B68A07AE.jpegF90CD5EF-1A26-4C4A-9C84-046E49642545.jpeg
                      Reply  Fri Feb 19 14:43:09 2021, aaron, Computing, DAQ, AI chassis diagnosis 
                   Reply  Tue Mar 9 14:03:12 2021, aaron, Computing, DAQ, oma model 
Entry  Tue Mar 9 13:57:38 2021, aaron, DailyProgress, , update 
Entry  Mon Mar 8 12:11:15 2021, aaron, DailyProgress, Laser, busby, sr554 to cryo lab 
Entry  Wed Mar 3 14:52:43 2021, rana, Misc, Noise Budget, data files for laser noise 
    Reply  Thu Mar 4 09:44:24 2021, aaron, Misc, Noise Budget, data files for laser noise 
Entry  Tue Mar 2 13:50:35 2021, aaron, Lab Infrastructure, Drawings, PSOMA table clean enclosure table_enclosure_side.pdftable_enclosure_end.pdf
Entry  Fri Feb 26 13:24:31 2021, rana, Noise Hunting, Laser, setup beatnote to Teraxion laser 
Entry  Thu Feb 25 14:21:35 2021, aaron, DailyProgress, ,  
    Reply  Fri Feb 26 10:26:05 2021, Chris, DailyProgress, DAQ,  
    Reply  Fri Feb 26 11:52:31 2021, rana, Computing, DAQ, Cymac & Matlab 
Entry  Tue Feb 23 13:43:57 2021, aaron, DailyProgress, PSOMA, condensed fiber layout 2AAF19D0-3F40-4146-9975-8EF4545C91A7.jpeg
Entry  Thu Feb 18 14:06:56 2021, aaron, Noise Hunting, PSOMA, ITC 502 current noise IMG_0017.PNGIMG_0018.PNGIMG_0019.PNG2DBAD4BD-C058-42FB-903F-98128E99F789.jpeg
    Reply  Fri Feb 19 09:39:35 2021, rana, Noise Hunting, PSOMA, ITC 502 current noise 
    Reply  Fri Feb 19 14:26:08 2021, rana, Noise Hunting, PSOMA, ITC 502 current noise 
       Reply  Fri Feb 19 14:34:44 2021, aaron, Noise Hunting, PSOMA, ITC 502 current noise 
Entry  Fri Feb 19 13:24:10 2021, aaron, DailyProgress, Lab Work,  
Entry  Fri Feb 19 00:52:40 2021, rana, Electronics, Electronics, inspecting W diode driver 
Entry  Mon Jan 25 13:02:46 2021, aaron, Update, PSOMA,  
    Reply  Thu Feb 18 13:05:50 2021, aaron, Update, PSOMA,  beat_ASD.pdflasers_ASD.pdf
Entry  Tue Feb 9 22:43:29 2021, rana, Noise Hunting, Laser, "North" current driver having slow current fluctuations PXL_20210210_063043141.jpg
    Reply  Wed Feb 10 09:52:45 2021, shruti, Noise Hunting, Laser, "North" current driver having slow current fluctuations 
    Reply  Mon Feb 15 21:25:00 2021, rana, Noise Hunting, Laser, "North" current driver having slow current fluctuations Planex-Beatnote.pdfPlanex-Beatnote-ASD.pdfplotPhaseMeter.tar.gz
    Reply  Thu Feb 18 12:30:09 2021, aaron, Noise Hunting, Laser, "North" current driver having slow current fluctuations 
Entry  Wed Feb 17 13:25:52 2021, aaron, DailyProgress, PSOMA, electronics management 
Entry  Tue Feb 16 14:27:40 2021, aaron, DailyProgress, Purchases, upcoming wire shelf 
Entry  Thu Jan 28 18:03:53 2021, shruti, DailyProgress, PSOMA, cavity locking Path.pdf
    Reply  Mon Feb 1 18:25:47 2021, shruti, DailyProgress, PSOMA, cavity locking 
       Reply  Wed Feb 3 10:56:54 2021, shruti, Update, PSOMA, cavity locking 
          Reply  Thu Feb 4 16:19:35 2021, shruti, Update, PSOMA, cavity alignment 5FC37CEF-5B30-4FF0-ADF6-9FD4C59A1027.jpeg
             Reply  Thu Feb 4 22:27:43 2021, rana, Update, PSOMA, cavity alignment IMC_HOManalysis.ipynb
                Reply  Tue Feb 9 11:14:48 2021, shruti, Update, PSOMA, cavity alignment 
                   Reply  Tue Feb 16 11:30:14 2021, shruti, Update, PSOMA, Beat recovered, fiber organization, alignment F2E33DA5-DB03-46EC-B341-E388D96F1BC5.jpeg069D0D53-9111-4B33-96AD-05B907C4BBCB.jpegBeat_low_freq_oscillations.mp4
Entry  Mon Nov 30 11:28:30 2020, aaron, Noise Hunting, Laser, pll IMG_0195.jpg
    Reply  Tue Dec 1 10:59:49 2020, aaron, Noise Hunting, Laser, pll 
       Reply  Wed Dec 2 13:37:55 2020, aaron, Noise Hunting, Laser, W laser oscillating 
          Reply  Thu Dec 3 10:18:07 2020, aaron, Noise Hunting, Laser, pll 
          Reply  Thu Dec 3 11:57:52 2020, rana, Noise Hunting, Laser, W laser oscillating 
             Reply  Fri Dec 4 10:36:18 2020, aaron, Noise Hunting, Laser, pll IMG_0015.PNG
                Reply  Sun Dec 6 19:22:10 2020, rana, Noise Hunting, Laser, pll 
                   Reply  Thu Dec 10 10:05:03 2020, aaron, Noise Hunting, Laser, pll IMG_0016.PNG
       Reply  Wed Feb 10 12:39:08 2021, rana, Noise Hunting, Laser, pll 
          Reply  Thu Feb 11 09:59:31 2021, aaron, Noise Hunting, Laser, pll 
          Reply  Thu Feb 11 17:24:41 2021, rana, Noise Hunting, Laser, pll PXL_20210212_000327036~2.jpg
             Reply  Mon Feb 15 14:57:25 2021, aaron, Noise Hunting, Laser, pll 
Entry  Thu Feb 11 14:44:41 2021, aaron, Computing, DAQ, wake up spirou 
Entry  Tue Feb 9 13:51:29 2021, aaron, DailyProgress, PSOMA, fiber organization 
Entry  Tue Feb 9 13:29:15 2021, rana, Noise Hunting, Laser, how to reduce noise in fibers due to wind and temperature 
Entry  Fri Jan 29 09:52:29 2021, karthik, Notes, , PSOMA Temp Controller tuning 
    Reply  Wed Feb 3 17:32:29 2021, rana, Notes, Control System, PSOMA Temp Controller tuning 
       Reply  Wed Feb 3 17:56:52 2021, aaron, Notes, Control System, PSOMA Temp Controller tuning 
Entry  Wed Feb 3 12:45:25 2021, aaron, DailyProgress, PSOMA, strain relieved connectors 088D1291-38F5-4CE8-BA8A-B19721D1A275.jpeg615135D1-D668-4328-B757-4548C758C0FB.jpeg
Entry  Thu Jan 28 12:42:14 2021, aaron, HowTo, DAQ, grabbing nds data 
Entry  Thu Jan 28 11:54:56 2021, Paco, Notes, Equipment Loan, Beam profiler and laptops 
Entry  Wed Jan 27 09:11:16 2021, aaron, DailyProgress, PSOMA, lab improvements Screenshot_from_2021-01-27_10-30-03.png
    Reply  Wed Jan 27 22:01:16 2021, rana, DailyProgress, PSOMA, lab improvements 
Entry  Mon Jan 25 16:36:24 2021, rana, Misc, General, needs 
    Reply  Wed Jan 27 11:58:25 2021, rana, Misc, General, needs 
Entry  Mon Jan 25 21:59:34 2021, rana, Summary, Laser, test laser 
Entry  Thu Jan 21 15:25:13 2021, aaron, DailyProgress, Lab Work,  Screenshot_from_2021-01-21_19-57-47.png
Entry  Fri Jan 15 09:54:18 2021, aaron, HowTo, PSOMA, mode matching 
Entry  Thu Jan 14 17:16:35 2021, aaron, DailyProgress, PSOMA, free space setup 2CCC0C42-017F-45B5-A4DD-E451953DE4E2.jpegDF68EBCD-37F3-4CA2-B6C0-6E96146C49C9.jpeg517E4CCF-D12F-4C87-888F-516E21D28049.jpeg
Entry  Wed Jan 13 11:07:24 2021, aaron, DailyProgress, PSOMA, fiber + free 3 corner hat labTemp.png
Entry  Wed Jan 6 10:47:18 2021, aaron, DailyProgress, PSOMA, DC to PSOMA rack, realtime model 
Entry  Mon Jan 4 10:46:01 2021, aaron, Lab Infrastructure, Temperature Sensing, fresh temperature sensor Screenshot_from_2021-01-04_16-13-53.png
    Reply  Tue Jan 5 16:43:44 2021, aaron, Lab Infrastructure, Temperature Sensing, fresh temperature sensor Screen_Shot_2021-01-05_at_16.46.14.png
Entry  Wed Dec 23 11:13:57 2020, aaron, Things to Buy, Purchases, optomechanics arrived 
Entry  Thu Dec 17 10:23:08 2020, aaron, Notes, PSOMA, lab entry 
Entry  Mon Dec 14 10:32:51 2020, aaron, Update, ,  
Entry  Tue Nov 24 13:23:09 2020, aaron, Photos, Si fab, Si cantilever photos DSCF3580.JPGDSCF3572.JPG
    Reply  Sat Nov 28 21:53:12 2020, rana, Photos, Si fab, Si cantilever photos 
       Reply  Mon Nov 30 10:26:17 2020, rana, Photos, Si fab, Si cantilever photos 
Entry  Tue Oct 27 15:57:27 2020, shruti, DailyProgress, Lab Work, psoma locking  
    Reply  Wed Oct 28 12:42:31 2020, shruti, DailyProgress, Lab Work, psoma locking  Setup2020Oct27.pdfpsoma_PLL.pdfpsoma_pll_freespace_intermediate.pdf
       Reply  Thu Nov 19 11:23:44 2020, shruti, Update, Lab Work, psoma locking  PLL_FS_sym.pdfMZ_PLL_FS_sym.pdfNewBeat.pdf
          Reply  Tue Nov 24 10:16:04 2020, shruti, Update, Lab Work, psoma locking  BeatSetup.pdfBeatOrNot.pdf
             Reply  Fri Nov 27 13:38:18 2020, Shruti, Update, Lab Work, psoma locking  Beat.mp4BeatZoomed.pdf
                Reply  Fri Nov 27 19:43:33 2020, Koji, Update, Lab Work, psoma locking  
Entry  Tue Nov 24 15:58:00 2020, aaron, Notes, Equipment Loan, moku CTN to Cryo 
Entry  Fri Nov 20 19:24:00 2020, aaron, Electronics, Electronics, power cables DSCF3541.JPGDSCF3542.JPG
Entry  Thu Nov 19 16:34:01 2020, aaron, DailyProgress, General, cantilever photos, laser intensity noise 
Entry  Wed Nov 18 08:24:02 2020, shruti, Update, PSOMA, temp control and transverse beam profiles beamprofdata.zip
Entry  Tue Nov 17 14:56:06 2020, aaron, DailyProgress, General, lab entry 
Entry  Mon Nov 9 14:40:46 2020, shruti, Misc, Equipment Loan, Stuff for N2 transfer IMG_0334.pdf
Entry  Wed Oct 28 18:10:27 2020, aaron, Noise Hunting, Laser,  
Entry  Fri Oct 23 19:06:05 2020, gautam, Update, Equipment Loan, Two resonant RFPDs ---> 40m IMG_8903.JPG
Entry  Fri Apr 3 15:21:38 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation 
    Reply  Mon Apr 13 17:30:35 2020, rana, Computing, Simulation, Moderinger Simulation 
    Reply  Wed Apr 22 15:03:59 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation Moderinger.pdfsimplemoderinger.slx
       Reply  Wed Apr 22 16:41:31 2020, rana, HowTo, Simulation, Moderinger Simulation 
          Reply  Thu Apr 23 13:30:51 2020, Ian MacMillan, HowTo, Simulation, Moderinger Simulation simplemoderinger.slx
             Reply  Fri May 1 03:22:05 2020, Ian MacMillan, HowTo, Simulation, Moderinger Simulation ModeringerSimV2Layout.pdfsimplemoderinger.slx
                Reply  Sun May 3 20:51:14 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation Moderinger_V2.zip
                   Reply  Tue May 5 13:04:23 2020, aaron, Computing, Simulation, Moderinger Simulation 
                      Reply  Tue Sep 29 02:02:54 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation ModeRingerLoop.pdfStepPlot.pdfPowerSpectrum.pdfModeRingerSim.zip
                         Reply  Tue Sep 29 11:00:53 2020, aaron, Computing, Simulation, Moderinger Simulation 
                            Reply  Thu Oct 8 00:31:11 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation ModeRingerLoopDig.pdfModeRingerSim.zip
                               Reply  Thu Oct 15 22:15:11 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation ModeRingerSpec.pdf
                   Reply  Tue May 5 13:05:36 2020, Ian MacMillan, Computing, Simulation, Moderinger Simulation ModeringerNotebook.ipynb
Entry  Tue Sep 22 21:30:07 2020, aaron, DailyProgress, Lab Work, lab entry, supplies 
Entry  Thu Sep 10 10:21:34 2020, aaron, Lab Infrastructure, HVAC, HEPA filters for PSOMA enclosure 
    Reply  Tue Sep 15 12:29:41 2020, rana, Lab Infrastructure, HVAC, HEPA filters for PSOMA enclosure 
Entry  Wed Sep 2 16:46:39 2020, aaron, Things to Buy, Drawings, dimension-full optical layout psoma_stage2.pdf
Entry  Wed Sep 2 16:19:57 2020, shruti, Update, Lab Work, lab entry, information gathering 7BA40146-4F86-4819-8D6C-FFDC8F246E50.jpeg129FE089-1E57-4E6D-9E77-F80F8E124CD1.jpeg
Entry  Tue Aug 25 13:42:40 2020, aaron, Update, Lab Work, optics setup 
    Reply  Wed Aug 26 12:12:22 2020, aaron, Update, Lab Work, optics setup 
       Reply  Fri Aug 28 16:59:59 2020, aaron, Update, Lab Work, optics setup 
          Reply  Mon Aug 31 10:00:25 2020, aaron, Update, Lab Work, optics setup 200828_layout.jpg
Entry  Thu Aug 27 13:24:30 2020, aaron, Lab Infrastructure, stuff happens, locked out of optomechanics cabinet 
Entry  Tue Aug 25 13:23:49 2020, aaron, Things to Buy, General, cryo lab inventory 
Entry  Mon Aug 24 13:21:40 2020, aaron, Update, Lab Work, notice of entry 
    Reply  Mon Aug 24 13:22:32 2020, aaron, Update, Lab Work, alaPSOMA 
Entry  Wed Aug 19 12:11:47 2020, aaron, Update, Lab Work, Notice of entry 
    Reply  Wed Aug 19 12:15:40 2020, aaron, Update, Lab Work, Notice of entry 
Entry  Tue Aug 18 15:05:33 2020, aaron, Update, Lab Work, notice of lab entry 
    Reply  Tue Aug 18 21:35:49 2020, aaron, Update, Lab Work, notice of lab entry 
Entry  Mon Aug 17 15:10:58 2020, aaron, DailyProgress, Lab Work, Notice of lab entry 
    Reply  Mon Aug 17 15:52:13 2020, aaron, DailyProgress, Lab Work, Notice of lab entry Ceiling_lookingSouth.jpegCeiling_lookingNorth.jpegClearance.jpeg
Entry  Wed Aug 5 19:03:56 2020, aaron, Update, Lab Work, Notice of lab entry 
    Reply  Fri Aug 7 11:35:09 2020, aaron, Update, Lab Work, lab work 
Entry  Mon Aug 3 13:10:46 2020, shruti, DailyProgress, Lab Work, Initial experiments and prep IMG_633BBA57553C-1.jpeg
    Reply  Tue Aug 4 14:08:44 2020, shruti, DailyProgress, Lab Work, Initial experiments and prep: Beam profile IMG_0268.jpgErf.pdfDiv.pdfbeamprofdata.zipIMG_0258.jpg
Entry  Thu Jul 30 09:13:14 2020, shruti, DailyProgress, Lab Work, beam profile prep 
    Reply  Fri Jul 31 08:51:00 2020, shruti, DailyProgress, Lab Work, beam profile prep 
Entry  Tue Jul 28 13:33:06 2020, aaron, Update, Lab Work, Rio laser 
    Reply  Tue Jul 28 16:13:56 2020, aaron, Update, Lab Work, Air flow measurement 
Entry  Sun Jul 26 20:37:50 2020, aaron, Update, ,  
    Reply  Mon Jul 27 12:11:49 2020, aaron, Update, Lab Work, Simplifying W optic bench 
Entry  Fri Jul 24 15:59:12 2020, aaron, Update, Lab Work, cryo open 
    Reply  Fri Jul 24 16:12:13 2020, aaron, Update, Lab Work, cryo open 
Entry  Mon Jul 20 08:59:02 2020, shruti, Update, Lab Work, At cryo lab FFDA12DE-AD53-4751-96C5-7AA726F4BC51.jpeg332F07DE-A250-44A6-BA28-5A0DF65207E9.jpeg
    Reply  Tue Jul 21 14:03:33 2020, shruti, Update, Lab Work, At cryo lab 156CA9F4-5287-4222-9C45-5ACA006DFEDC.jpeg64F84876-1D78-427F-B272-5584D0D7AC2C.jpegB56E1C6B-C039-4E7E-85F1-AEFE8FA1BEAB.jpegD540AD24-6D44-447C-B87F-B6CCD01D9521.jpeg
Entry  Thu Jul 16 11:27:18 2020, aaron, Update, Lab Work, Reopening cryo lab 
    Reply  Fri Jul 17 13:15:03 2020, aaron, Update, Lab Work, Reopening cryo lab tape_before.pdfglasses.pdf
Entry  Mon Jun 8 15:26:10 2020, aaron, Notes, Safety, Plan for reopened Cryo lab activities 
    Reply  Tue Jun 9 13:58:55 2020, aaron, Notes, Safety, Plan for reopened Cryo lab activities Caltech_HVAC_System_Standards_Infomation.pdfResearcher_Back-to-Lab_Checklist.docx.pdfPI_Return_to_Work_Lab_Planning_Guidance.docx.pdf
       Reply  Tue Jun 9 14:19:46 2020, aaron, Notes, Safety, Template for logging lab entry / exit COVID-19_Glove_Usage_Guidance.docx.pdfWork_Station_Sanitation_Protocol.docx.pdf
          Reply  Thu Jul 16 12:09:18 2020, aaron, Notes, Safety, Template for logging lab entry / exit 
Entry  Mon Apr 27 17:02:24 2020, Ian MacMillan, HowTo, , Basic Simulink Tutorial TutorialCL.pdfTutorialCL.slxTutorialCLResponse.pdf
    Reply  Mon Apr 27 19:15:32 2020, rana, HowTo, , Basic Simulink Tutorial 
Entry  Thu Apr 23 20:34:42 2020, Chris, Electronics, DAQ, ADC differential and single-ended readout adc.pdf
Entry  Tue Apr 21 13:17:24 2020, Jon, Lab Infrastructure, DAQ, LDAS backups of frames data 
Entry  Sun Mar 8 18:17:06 2020, Duo, HowTo, Qryo, General procedures to identify modes and calculate the Q ringdown.py
    Reply  Fri Mar 13 12:10:19 2020, rana, HowTo, Qryo, General procedures to identify modes and calculate the Q 
       Reply  Wed Apr 8 16:17:36 2020, Duo, HowTo, Qryo, New script calculating Q and a little thing about nds2 Mode2298Ringdown.zipringdown1.py
Entry  Sun Mar 8 18:02:40 2020, Duo, DailyProgress, Qryo, More modes between 500Hz and 5000Hz Mode973.zipMode1007.zipMode2230.zipMode2299.zipMode3902.zip
Entry  Sat Mar 7 23:21:10 2020, Duo, DailyProgress, Qryo, Room temperature Q calculated Ringdown.pdfRingdownAmplitude.pdfRingdownAmplitudeFit.pdfeverything.zip
Entry  Fri Mar 6 18:16:57 2020, Duo, DailyProgress, Qryo, Mode Ringing ModeFound2296Hz.pdfpolarization.pdfModeDecay.pdf
Entry  Mon Mar 2 18:37:00 2020, Duo, DailyProgress, Lab Work, Excitation working again thumbnail_image1.jpg
Entry  Mon Mar 2 11:00:57 2020, Ian MacMillan, DailyProgress, Qryo, Procedure Check and Equipment Function Check 
Entry  Thu Feb 27 13:46:17 2020, Ian MacMillan, Lab Infrastructure, General, Cleaning the lab 
Entry  Thu Feb 27 13:24:32 2020, Ian MacMillan, DailyProgress, Vacuum, Pumping down 
Entry  Tue Feb 25 21:41:01 2020, Duo, Summary, Optics, Beam Alignment QPD.jpgOpticsTable.jpgdiagram.pngCryostatMirror.jpgInNoutOfCyrostat.jpg
    Reply  Wed Feb 26 11:11:14 2020, Ian MacMillan, Summary, Optics, Beam Alignment 
       Reply  Wed Feb 26 13:12:28 2020, Ian MacMillan, Summary, Optics, Beam Alignment 
    Reply  Wed Feb 26 14:04:41 2020, Ian MacMillan, Summary, Optics, Beam Alignment 
Entry  Tue Feb 25 14:49:12 2020, Ian MacMillan, DailyProgress, Qryo, Beam Alignment 
Entry  Fri Feb 14 15:45:42 2020, Duo, HowTo, , How to use the digital system 
Entry  Mon Feb 10 16:29:06 2020, Ian MacMillan, Misc, Qryo, Getting Started 
Entry  Tue Nov 26 17:35:59 2019, Chris, Lab Infrastructure, General, CDS rebuild/upgrade 
    Reply  Fri Jan 10 14:08:57 2020, Chris, Lab Infrastructure, General, SiLabs 5340 timing ticking along Si5340-RevD-RTSCLOCK-Registers.txt.gz
Entry  Fri Nov 15 17:24:45 2019, Raymond, Notes, General, Borrowed IR Labs cryostat 
Entry  Wed Oct 30 17:30:44 2019, Chris, Electronics, stuff happens, Sorensen DC power supply drop-out 
Entry  Tue Oct 22 15:53:24 2019, Koji, Notes, Electronics, Borrowed ITC510 / LB1005 
Entry  Tue Oct 22 11:07:16 2019, anchal, Misc, General, Borrowing two ZFDC-20-5-S+ 
Entry  Tue Oct 15 17:11:34 2019, Raymond, Notes, Coatings, CNT coated disc Si_CNTcoating_samplebox10152019.pngSi_CNTcoating_front10152019.pngSi_CNTcoating_backside10152019.png
Entry  Tue Oct 8 11:20:30 2019, aaron, HowTo, Qryo, Walkthrough of moderinger moderinger_Howto.png
Entry  Wed Oct 2 19:42:36 2019, rana, HowTo, Simulation, how to do time domain filtering in python 
Entry  Wed Aug 21 17:39:41 2019, mahiro, DailyProgress, , disk + metamaterial full system fullsystemnodes.pngfullsystemantinodes.png
Entry  Tue Aug 20 18:16:31 2019, anna, DailyProgress, Lab Work,  
Entry  Mon Aug 19 17:13:17 2019, aaron, Update, stuff happens, Leak valve not operable 
Entry  Fri Aug 16 13:19:42 2019, aaron, Update, Qryo, Topped off lN2 
Entry  Tue Aug 13 19:04:03 2019, mahiro, Notes, , Using sandbox1 sandbox1commands.pdf
Entry  Mon Aug 5 14:00:48 2019, anna, DailyProgress, Lab Work, ESD Issues 
    Reply  Wed Aug 7 15:39:03 2019, aaron, DailyProgress, Lab Work, ESD Issues 
       Reply  Thu Aug 8 14:46:56 2019, aaron, DailyProgress, Lab Work, ESD Issues before_FErestart.pngafter_startAll.png
Entry  Tue Aug 6 17:08:49 2019, Anna, DailyProgress, , Thickness value from fminsearch 
    Reply  Wed Aug 7 16:03:19 2019, aaron, DailyProgress, , Thickness value from fminsearch 
Entry  Wed Aug 7 14:44:20 2019, Nathan Holland, Electronics, stuff happens, Borrowed 2x MiniCircuits SLP-10.7+. 
Entry  Tue Jul 30 16:32:03 2019, anna, DailyProgress, , Room temp measurements on disk 6  
Entry  Fri Jul 26 15:43:33 2019, Anna, DailyProgress, General, Mode ringer  6x
    Reply  Mon Jul 29 19:31:51 2019, rana, DailyProgress, General, Mode ringer  
Entry  Mon Jul 29 10:58:04 2019, anchal, Misc, General, Borrowed Laser Power meter for the day 
Entry  Mon Jul 29 00:56:21 2019, Shuba, Electronics, , Violet laser alignment 
Entry  Fri Jul 26 12:15:37 2019, Nathan Holland, Electronics, General, Borrowed Minicircuits ZFL-500LN+. 
Entry  Mon Jul 22 14:12:51 2019, aaron, HowTo, General, Cryogenics Knowledge Screen_Shot_2019-07-22_at_2.37.53_PM.png
    Reply  Tue Jul 23 15:07:03 2019, aaron, HowTo, General, Cryogenics Knowledge 
    Reply  Thu Jul 25 14:23:33 2019, aaron, HowTo, General, Cryogenics Knowledge GeNS_3_inCryo.easm
Entry  Thu Jul 25 13:43:34 2019, mahiro, Notes, , metamaterials update 30masssystemplot_damped.pngresonatorplusTL.pnglumpedsystemplot.pngphotomaskiteration1.png
Entry  Wed Jul 24 22:17:08 2019, anna, DailyProgress, Lab Work, Cryostat modifications "20% chance of working"-aaron 
Entry  Fri Jul 19 21:34:05 2019, aaron, DailyProgress, General, Anchal in the cryo lab, organization 
Entry  Fri Jul 19 17:50:08 2019, Duo, Misc, stuff happens, My directory on Gaston disappeared? 
    Reply  Fri Jul 19 21:33:03 2019, Duo, Misc, stuff happens, My directory on Gaston disappeared? 
Entry  Thu Jul 18 21:01:08 2019, Shuba, DailyProgress, , Cryostat Cool down Screenshot_from_2019-07-18_21-03-57.pngIMG_20190718_203905.jpg
Entry  Wed Jul 17 22:46:09 2019, Duo, DailyProgress, Lab Work, Frontend restarted 
Entry  Wed Jul 17 16:58:20 2019, Shuba, DailyProgress, , BNCs, break out board,  
    Reply  Wed Jul 17 20:27:35 2019, Shubha, DailyProgress, , BNCs, break out board,  
    Reply  Wed Jul 17 20:28:23 2019, aaron, DailyProgress, , BNCs, break out board,  
Entry  Wed Jul 17 11:13:35 2019, Anna, DailyProgress, Lab Work, Additional Q measurements decay_fit_970.pdfdecay_fit_2224.pdfAnnaQcode_one_datafile.zip
Entry  Tue Jul 16 14:30:47 2019, aaron, shuba, DailyProgress, Temperature Sensing, Installing new RTDs, prepping for temperature measurements IMG_20190716_151913.jpgIMG_20190716_191801.jpg
Entry  Mon Jul 15 18:02:48 2019, Anna, DailyProgress, Lab Work, Prepping RTDs to put back in cryostat IMG_3432.JPG
Entry  Fri Jul 12 21:09:55 2019, Anna, DailyProgress, Lab Work, Q calculations pitch.pngmixedsig.pnglowpass.pngjustdecay.pngdecay_fit.png
Entry  Fri Jul 12 18:53:52 2019, Koji, Notes, General, Optical chopper loan 
Entry  Thu Jul 11 19:25:41 2019, Shuba, Electronics, , Laser diode working IMG_20190711_172056.jpgVID_20190711_180553.mp4L405P20-SpecSheet.pdf
Entry  Thu Jul 11 18:19:05 2019, Anna, DailyProgress, Lab Work, Q measurements 
Entry  Thu Jul 11 11:19:20 2019, aaron, Computing, DAQ, cymac1 not down 
Entry  Thu Jul 11 10:39:21 2019, aaron, Update, Qryo, Cold Qs 
Entry  Thu Jul 11 10:14:52 2019, Mahiro, DailyProgress, , 1D transmission line calculations 
Entry  Wed Jul 10 20:38:45 2019, Anna, DailyProgress, Lab Work, Data is not recording again 
Entry  Wed Jul 10 17:18:42 2019, Duo, Lab Infrastructure, Lab Work, Lab temperature channel up IMG_0804.jpg
Entry  Wed Jul 10 13:57:40 2019, Shubha, DailyProgress, , Circuit Analysis IMG_20190710_152151.jpg
Entry  Tue Jul 9 17:40:02 2019, aaron, DailyProgress, Lab Work, Laser driver circuit, cymac 04_PM.png
Entry  Tue Jul 9 14:43:43 2019, Shubha, DailyProgress, Lab Work, Laser driver malfunctioning 
Entry  Mon Jul 8 16:57:04 2019, Anna, DailyProgress, Noise Budget,  Powerspectrum.jpgScreen_Shot_2019-07-08_at_4.36.41_PM.png
Entry  Mon Jul 8 16:35:47 2019, Shuba, DailyProgress, Lab Work, Testing the laser current driver IMG_20190708_164422.jpgIMG_20190708_164641.jpg
Entry  Wed Jul 3 15:02:48 2019, Shuba, DailyProgress, Lab Work, Checking the calibration of laser driver and recording some eigen-frequencies 7x
    Reply  Mon Jul 8 12:17:19 2019, Shubha, DailyProgress, Lab Work, Checking the calibration of laser driver and recording some eigen-frequencies 
Entry  Tue Jul 2 22:41:49 2019, Anna, DailyProgress, Lab Work, Exciting nodes and taking data Anna_mode_(2).pngweirdQPD.pngAnna_mode.pngAnna_mode2.pngAnna_ringdown.png
Entry  Mon Jul 1 19:47:20 2019, Shuba, DailyProgress, Lab Work, 970Hz Eigenfrequency rediscovered 9x
Entry  Mon Jul 1 16:40:14 2019, Anna, DailyProgress, Noise Budget, Elastic strain energy density  
Entry  Mon Jul 1 12:42:27 2019, aaron, Update, Lab Work, Cryo cleanup, experiments this week 
Entry  Fri Jun 28 17:08:18 2019, Anna, Summary, Lab Work, Measuring Qs 
Entry  Fri Jun 28 09:10:49 2019, Mahiro, Notes, Mechanics, Metamaterials Update rectangularsheet.jpgdoublepaddleoscillator.jpgDPO_modeshapes.PNGsimpletorsionoscillator.jpgbusartorsionoscillator.jpg
Entry  Sat Aug 4 22:24:59 2018, johannes, HowTo, Laser, Measuring laser current noise 
    Reply  Mon Aug 6 23:16:20 2018, johannes, HowTo, Laser, Measuring laser current noise Screenshot_from_2018-08-06_23-15-21.pnginstr_amp_tf_20180806.pdfinstr_amp_input_noise_20180806.pdf
       Reply  Mon Aug 6 23:59:30 2018, johannes, HowTo, Laser, jfet amplifier circuit Capture.JPGjfet_amp_tf.pdfjfet_amp_n.pdf
          Reply  Mon Aug 13 02:28:22 2018, rana, HowTo, Laser, jfet amplifier circuit 
       Reply  Wed Aug 8 00:43:12 2018, johannes, HowTo, Laser, Measuring laser current noise instr_amp_input_noise_20180806.pdfcurrent_noise_20180807.pdf
    Reply  Mon Aug 13 02:29:48 2018, rana, HowTo, Laser, Consider the Source Impedance 
       Reply  Wed Aug 15 23:59:34 2018, johannes, HowTo, Laser, Consider the Source Impedance current_noise_scheme.pdfdriver_current_noise.pdf
          Reply  Mon Aug 20 01:18:23 2018, johannes, Update, Laser, Current Driver Errants CurrentDriverMosfetMod.pdfCurrentDriverMosfetModSchematic.pdf20180817_161907.jpgdriver_current_noise.pdf
             Reply  Mon Apr 8 04:45:55 2019, johannes, Update, Laser, Current Driver DCC updated schematic_changes.JPGdiode_protection.JPGtransistor_swap.JPG
                Reply  Thu Jun 27 06:20:25 2019, johannes, Update, Laser, CryoCavs TF-board Mods tf-board_D1700471v2_stage1.pngtf-board_D1700471v2.pngtf-board_D1700471v2.pdfTF-Board.zip
Entry  Wed Jun 26 15:07:35 2019, ScottA, Misc, General, Borrowing DC Bias Tee 
Entry  Tue Jun 25 14:51:27 2019, aaron, mahiro, DailyProgress, Lab Work, Aligning periscope, prepping for more Qs 20190624cryolabpictures.pdf
Entry  Mon Jun 24 19:34:58 2019, Anna, DailyProgress, Simulation, Eigenmode and strain models 12x
Entry  Thu Jun 20 10:42:17 2019, Shuba, DailyProgress, , Eigen frequency shift due to a heating beam using MATLAB LiveLink COMSOL Mesh.pngGraph.pngDisk_temperature.gif
Entry  Wed May 15 16:41:34 2019, Duo, DailyProgress, , Script to get basement lab data plots.pdfdownloadData.py
    Reply  Fri May 17 17:47:08 2019, rana, Electronics, HVAC, Script to get basement lab data 
       Reply  Wed Jun 19 21:11:43 2019, Duo, Electronics, HVAC, Script to get basement lab data image1.jpeg
Entry  Wed Jun 19 20:28:31 2019, Duo, Misc, General, Cryo lab label maker missing 
Entry  Wed Jun 19 17:28:48 2019, Shuba, HowTo, , Set up Pleione 
Entry  Fri Jun 7 19:03:08 2019, Duo, Electronics, , Current source current_source.pdf
    Reply  Sat Jun 8 15:59:49 2019, Duo, Electronics, , Current source 
       Reply  Mon Jun 10 17:39:45 2019, Duo, Electronics, , Current source 
          Reply  Thu Jun 13 14:30:29 2019, rana, Electronics, Temperature Sensing, RTD circuit 
             Reply  Fri Jun 14 18:32:48 2019, Duo, Electronics, Temperature Sensing, RTD circuit 
                Reply  Sat Jun 15 21:11:17 2019, Duo, Electronics, Temperature Sensing, RTD circuit CurrentSource.pdf
                   Reply  Mon Jun 17 09:20:57 2019, rana, Electronics, Temperature Sensing, RTD circuit 
                      Reply  Mon Jun 17 11:20:04 2019, Duo, Electronics, Temperature Sensing, RTD circuit 
                         Reply  Tue Jun 18 01:02:22 2019, Duo, Electronics, Temperature Sensing, RTD circuit 
Entry  Sat Jun 15 01:19:46 2019, Shuba, Summary, Lab Work, Standard working procedure to open and close the cryostat 
    Reply  Mon Jun 17 11:16:27 2019, Shuba, Summary, Lab Work, Standard working procedure to open and close the cryostat 
Entry  Thu Jun 13 12:27:14 2019, Shuba, DailyProgress, , COMSOL Model - temperature sweep and eigen frequency new_mesh.JPG
Entry  Fri Jun 7 21:59:24 2019, Shuba, DailyProgress, Simulation, COMSOL Flowchart: Time-dependent eigen frequency calculation with a heating beam Flowchart.jpg
Entry  Thu Jun 6 15:46:42 2019, Duo, Electronics, , Plan for making Flex Circuit Boards for the RTD  IMG_0772.jpgScreenshot_(4).png
    Reply  Thu Jun 6 16:06:43 2019, aaron, Electronics, , Plan for making Flex Circuit Boards for the RTD  
    Reply  Fri Jun 7 18:59:20 2019, rana, Electronics, , Plan for making Flex Circuit Boards for the RTD  
Entry  Fri Jun 7 16:21:15 2019, Duo, DailyProgress, , Flex circuit board for the RTDs and current source 
Entry  Thu Jun 6 12:47:29 2019, Shuba, DailyProgress, , Tilt frequency of free disk free_disk_frequency_calculation.pdf
Entry  Thu May 30 15:44:02 2019, Duo, DailyProgress, , Still no mode 
    Reply  Fri May 31 14:00:24 2019, Duo, DailyProgress, , Still no mode 
       Reply  Fri May 31 17:50:10 2019, Duo, DailyProgress, , Still no mode 
Entry  Thu May 30 13:46:45 2019, Duo, DailyProgress, , DAC works Screenshot_from_2019-05-30_13-50-26.pngimage1.jpeg
Entry  Wed May 29 09:57:22 2019, Shuba, DailyProgress, , Diagnosis of ADC and DAC Screenshot_from_2019-05-29_09-52-12.pngimage1.jpegScreenshot_from_2019-05-29_10-05-37.png
    Reply  Wed May 29 11:01:40 2019, Chris, DailyProgress, , Diagnosis of ADC and DAC 
Entry  Tue May 28 17:41:26 2019, Shuba, DailyProgress, , Search for mode continues Screenshot_from_2019-05-28_18-10-28.pngScreenshot_from_2019-05-28_18-11-47.pngIMG_20190528_173730.jpgFotor_155909092793666.jpg
Entry  Tue May 28 13:49:39 2019, rana, Computing, General, STOP using GIT 
Entry  Thu May 23 16:13:09 2019, Duo, DailyProgress, , Still no mode Screenshot_from_2019-05-23_16-11-06.png
Entry  Fri May 17 17:03:57 2019, Duo, DailyProgress, , Excite the mode 
Entry  Wed May 15 21:27:37 2019, aaron , Computing, Lab Work, chasing around timing errors 
Entry  Wed May 15 11:28:40 2019, aaron, HowTo, Qryo, Qryo Model Files 
Entry  Fri May 10 12:46:43 2019, aaron, DailyProgress, Cryo Q, New cold window 
    Reply  Fri May 10 16:06:11 2019, aaron, DailyProgress, Cryo Q, cymac still crashing 
    Reply  Sun May 12 12:39:52 2019, aaron, DailyProgress, , New cold window 
       Reply  Mon May 13 14:39:11 2019, aaron, DailyProgress, , New cold window TeflonPostProfile.pdfTeflonHeat.pdf
          Reply  Mon May 13 19:18:55 2019, aaron, DailyProgress, , New cold window 
             Reply  Tue May 14 16:29:52 2019, aaron, DailyProgress, , New cold window 
                Reply  Tue May 14 21:54:38 2019, aaron, DailyProgress, , New cold window 
Entry  Tue May 14 13:46:13 2019, Duo, DailyProgress, , Lab temperature monitor summary 
Entry  Mon May 13 23:41:20 2019, Duo, DailyProgress, , Lab temperature monitor exploration 
Entry  Sun May 12 17:49:52 2019, rana, Misc, General, update Wiki 
Entry  Thu May 9 20:16:15 2019, Duo, DailyProgress, , PECVD at KNI 
    Reply  Thu May 9 23:57:36 2019, aaron, DailyProgress, , PECVD at KNI 
Entry  Thu May 9 23:44:08 2019, Duo, DailyProgress, , Exploration of Lab temp mystery 
Entry  Tue May 7 23:34:26 2019, aaron, Update, Cryo, Quick vent, new disk loaded, making it colder wrap.jpgring.jpginstalled.jpgindiumshield.jpgfitcheck.heic
    Reply  Wed May 8 11:17:40 2019, aaron, Update, Cryo, Quick vent, new disk loaded, making it colder 
       Reply  Wed May 8 17:45:29 2019, aaron, Update, Cryo, Q measurements 
          Reply  Wed May 8 22:14:50 2019, rana, Update, Cryo, Q measurements 
Entry  Wed May 8 17:11:40 2019, aaron, Lab Infrastructure, Cryo Q, Cryo wiki updates 
Entry  Sat May 4 17:24:35 2019, aaron, Lab Infrastructure, HVAC, Inversion layer at the cryostat 
    Reply  Sun May 5 11:20:05 2019, aaron, Lab Infrastructure, HVAC, Inversion layer at the cryostat 
       Reply  Sun May 5 23:38:14 2019, aaron, Lab Infrastructure, HVAC, Cold again ringing.pngringing.png
          Reply  Mon May 6 14:43:35 2019, aaron, Lab Infrastructure, HVAC, Cold again Screenshot_from_2019-05-07_02-04-51.png
Entry  Sun May 5 20:13:55 2019, aaron, Computing, Temperature Sensing, realtime temperature monitoring, mode class 8x
    Reply  Mon May 6 12:41:05 2019, aaron, Computing, Temperature Sensing, realtime temperature monitoring, mode class 
Entry  Thu May 2 14:11:36 2019, aaron, DailyProgress, Si fab, freshly passivated disks 
    Reply  Thu May 2 22:31:10 2019, aaron, DailyProgress, Cryo Q, loading disk triplet.pngnolines.pngnolines.png
       Reply  Fri May 3 16:07:04 2019, aaron, DailyProgress, Cryo Q, Characterizing modes 
          Reply  Sat May 4 11:28:55 2019, aaron, DailyProgress, Cryo Q, Characterizing modes 8x
             Reply  Sat May 4 14:55:20 2019, duo, DailyProgress, Cryo Q, Characterizing modes 
                Reply  Sun May 5 11:09:49 2019, aaron, DailyProgress, Cryo Q, Warmup 
Entry  Wed Apr 17 09:23:37 2019, aaron, DailyProgress, Cryo Q, RCA Cleaned Disk 
    Reply  Wed Apr 17 13:48:34 2019, aaron, DailyProgress, Cryo Q, RCA Cleaned Disk RCA_1_and_2_Wafer_Clean(1).pdf
       Reply  Thu Apr 18 12:50:24 2019, aaron, DailyProgress, Cryo Q, RCA Cleaned Disk 
          Reply  Thu Apr 18 18:39:58 2019, aaron, DailyProgress, Cryo Q, Cryostat is VERY COLD triangle.pngchoice.pngnochoice.pngrung.png
             Reply  Fri Apr 19 11:29:55 2019, aaron, DailyProgress, Cryo Q, timing issues modesringing.png
                Reply  Tue Apr 23 16:15:40 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE 7x
                   Reply  Tue Apr 23 23:20:51 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE 8x
                      Reply  Wed Apr 24 19:15:09 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE steppingfilterphase.pngSINPHASE_filters.png
                         Reply  Thu Apr 25 12:04:04 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE steppingfilterphase.pngloopshaping2.pngstartstep.png
                            Reply  Fri Apr 26 13:59:41 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE doublemode.png
                            Reply  Fri Apr 26 14:42:51 2019, rana, DailyProgress, Cryo Q, searching for zero CTE 
                               Reply  Sat Apr 27 15:37:11 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE 
                                  Reply  Tue Apr 30 16:30:20 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE 
                                     Reply  Wed May 1 13:19:17 2019, aaron, DailyProgress, Cryo Q, searching for zero CTE 
Entry  Thu Apr 18 12:57:32 2019, Aaron, Lab Infrastructure, General, Cryo Lab Property 
    Reply  Wed Apr 24 16:06:04 2019, Chris, Lab Infrastructure, General, Cryo Lab Property 
Entry  Fri Apr 19 19:26:57 2019, rana, Computing, DAQ, new Cymac 
    Reply  Fri Apr 19 20:14:29 2019, aaron, Computing, DAQ, new Cymac clock.pngScreenshot_from_2019-04-19_21-24-42.png
       Reply  Sat Apr 20 12:08:40 2019, aaron, Computing, DAQ, new Cymac 
          Reply  Tue Apr 23 13:51:39 2019, aaron, Computing, DAQ, new Cymac modelrate.png
Entry  Fri Apr 5 11:17:28 2019, aaron, Cryostat, Cryo, Improving the thermal environment 
    Reply  Mon Apr 8 12:35:01 2019, aaron, Cryostat, Cryo, Improving the thermal environment riseTest.pngcoldplate.jpg
       Reply  Tue Apr 9 15:14:12 2019, aaron, Cryostat, Cryo, Improving the thermal environment 
          Reply  Tue Apr 9 19:47:59 2019, aaron, Cryostat, Cryo, Improving the thermal environment 
             Reply  Wed Apr 10 17:11:25 2019, aaron, Cryostat, Cryo, Improving the thermal environment cold_plate.jpgindium.jpgstrap.jpgsubstrateholder.jpgloosefoil.jpg
                Reply  Thu Apr 11 12:34:32 2019, aaron, Cryostat, Cryo, Improving the thermal environment 
                   Reply  Thu Apr 11 14:50:04 2019, aaron, Cryostat, Cryo, Improving the thermal environment 7x
                      Reply  Fri Apr 12 16:54:47 2019, rana, HowTo, Control System, Improving the thermal environment 
                         Reply  Mon Apr 15 14:07:50 2019, aaron, DailyProgress, Digital PLL, Implementing digital PLL addedFREQ.pngwontcompile.png
                            Reply  Wed Apr 17 19:55:38 2019, aaron, DailyProgress, Digital PLL, Implementing digital PLL PLL.pngringing.pngringing.pngdecayaway.pngmorefilters.png
                         Reply  Tue Apr 23 11:26:30 2019, aaron, HowTo, Control System, Improving the thermal environment 
                      Reply  Fri Apr 12 17:12:20 2019, aaron, Cryostat, Cryo, Improving the thermal environment 
Entry  Thu Apr 18 16:25:30 2019, Duo, DailyProgress, , Messing around with the experiment Screenshot_from_2019-04-18_16-23-28.pngScreenshot_from_2019-04-18_16-38-06.png
Entry  Mon Apr 15 13:10:52 2019, aaron, DailyProgress, Cryo Q, This week's Qs pumpdown.png
    Reply  Tue Apr 16 10:22:55 2019, aaron, DailyProgress, Cryo Q, This week's Qs 6x
       Reply  Tue Apr 16 21:16:30 2019, aaron, DailyProgress, Cryo Q, This week's Qs Screenshot_from_2019-04-16_21-16-15.pngScreenshot_from_2019-04-16_21-45-53.pngmaybe.png
Entry  Fri Apr 5 19:59:33 2019, aaron, Noise Hunting, Temperature Sensing, New PLL frequency discriminant Screenshot_from_2019-04-05_20-30-06.png
    Reply  Sat Apr 6 00:56:36 2019, aaron, Noise Hunting, Temperature Sensing, New PLL frequency discriminant 
    Reply  Mon Apr 8 20:15:29 2019, aaron, Noise Hunting, Temperature Sensing, New PLL frequency discriminant Screen_Shot_2019-04-08_at_8.17.36_PM.pngScreen_Shot_2019-04-08_at_8.37.54_PM.png
       Reply  Mon Apr 8 21:32:50 2019, aaron, Noise Hunting, Temperature Sensing, New PLL frequency discriminant TCTRL.pngPLL0.png
          Reply  Tue Apr 9 20:24:07 2019, aaron, Noise Hunting, Temperature Sensing, New PLL frequency discriminant crash.png
Entry  Fri Apr 5 16:54:16 2019, aaron, Lab Infrastructure, HVAC, Hot Cryo Lab, Too Much Dust HVAC2.jpgHVAC3.jpgHVAC1.jpg
Entry  Fri Apr 5 12:51:35 2019, aaron, Electronics, Noise Budget, Cryostat still too cold, QPD noise measurements 6x
Entry  Thu Apr 4 14:46:52 2019, rana, Summary, Vacuum, on o-rings 
Entry  Wed Apr 3 16:43:02 2019, Duo, DailyProgress, , Metal posts replaced with tuflon ones & extra layer of heat cover 
    Reply  Thu Apr 4 11:58:31 2019, aaron, DailyProgress, , Metal posts replaced with tuflon ones & extra layer of heat cover foilAdded.jpgfoil2.jpgfoil3.jpg
       Reply  Thu Apr 4 14:23:02 2019, aaron, DailyProgress, , Metal posts replaced with tuflon ones & extra layer of heat cover MR2Setup.pngStepResponse_50mA.pngstepResponse_10mA_3.pngpumpdown_cymacCrash.pngsweptSine.png
Entry  Tue Mar 19 17:03:32 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc 
    Reply  Wed Mar 20 12:50:48 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc 
       Reply  Thu Mar 21 16:20:18 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc ballast_open.pngcryo_open.png
          Reply  Fri Mar 22 13:20:45 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc 
             Reply  Mon Mar 25 13:32:37 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc Pumpdown.pngoutgassing_annotated.jpg
                Reply  Tue Mar 26 18:34:15 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc 
                   Reply  Thu Mar 28 10:30:13 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc Screen_Shot_2019-03-28_at_10.43.35_AM.png
                      Reply  Fri Mar 29 13:06:29 2019, aaron, DailyProgress, Cryo Q, Vent, clamps added, new posts, KNI etc 6x
                         Reply  Fri Mar 29 15:14:39 2019, aaron, DailyProgress, Cryo Q, Vacuum resources Screen_Shot_2019-03-29_at_3.29.32_PM.pngScreen_Shot_2019-03-29_at_3.34.26_PM.png
                            Reply  Tue Apr 2 10:49:17 2019, aaron, DailyProgress, Cryo Q, Vacuum resources 
                               Reply  Thu Apr 4 12:20:42 2019, aaron, DailyProgress, Cryo Q, Vacuum resources cryopumpdown.pngcryoHosepumpdown.pnggoodOring_pumpdown.pngrateofRise.png
                         Reply  Sat Mar 30 14:07:20 2019, aaron, DailyProgress, Cryo Q, Cooldown, step responses Fridaynight.png
                            Reply  Sun Mar 31 15:10:12 2019, aaron, DailyProgress, Cryo Q, Cooldown, step responses stepResponse_0.pngScreenshot_from_2019-03-31_19-06-30.png
                               Reply  Sun Mar 31 21:12:56 2019, aaron, DailyProgress, Cryo Q, Cooldown, step responses 
Entry  Tue Apr 2 16:24:34 2019, Duo, DailyProgress, , PECVD at KNI and new O-ring retrieved 
    Reply  Tue Apr 2 21:50:15 2019, Aaron, DailyProgress, , PECVD at KNI and new O-ring retrieved Screen_Shot_2019-04-02_at_7.32.43_PM.png
Entry  Sun Mar 31 13:09:40 2019, aaron, HowTo, Si fab, Standard RCA Clean 
Entry  Thu Mar 21 15:20:14 2019, aaron, HowTo, Si fab, Processing Silicon 
    Reply  Tue Mar 26 13:37:20 2019, aaron, HowTo, Si fab, Processing Silicon 
Entry  Tue Mar 26 11:49:00 2019, aaron, Lab Infrastructure, Safety, Updated lab safety sign nfpa_1_laboratory_safety_sign_standard.pdf
Entry  Wed Mar 13 15:46:33 2019, aaron, DailyProgress, Cryo Q, cooldown, modehunting eigenfreq.pngnewzeros.png
    Reply  Thu Mar 14 14:30:04 2019, aaron, DailyProgress, Cryo Q, cooldown, modehunting 2_3kHz_ESDon.png2260Hz.pngstep_response.png
Entry  Fri Mar 8 18:58:46 2019, aaron, DailyProgress, DAQ, acromag channels down 
    Reply  Sat Mar 9 13:58:04 2019, aaron, DailyProgress, DAQ, acromag channels up? AI0_3.pngScreenshot_from_2019-03-09_14-01-54.pngRTD_temp.pngwhy.png
       Reply  Thu Mar 14 11:21:47 2019, aaron, DailyProgress, DAQ, New circuit 
Entry  Tue Mar 12 14:21:50 2019, aaron, Cryostat, Vacuum, turbo running slow pumpdowns.pngvented.pngD9ABA008-F48F-4821-8F10-9E691A388F5D.jpegmanualgasballast.png
    Reply  Wed Mar 13 10:21:44 2019, aaron, Cryostat, Vacuum, turbo running slow 
Entry  Tue Mar 12 17:17:02 2019, rana, Things to Buy, General, cables / twisted 
    Reply  Wed Mar 13 10:11:53 2019, aaron, Things to Buy, General, cables / twisted 
Entry  Mon Mar 11 10:58:51 2019, aaron, Update, Cryo Q, Cooldown 9A0C638B-09F2-4E37-8915-6D53A401B124.jpeg31485103-6B21-4BA1-97B7-01771CF50D0E.jpeg
    Reply  Mon Mar 11 14:09:03 2019, aaron, Update, Cryo Q, Cooldown 
Entry  Wed Feb 20 16:31:10 2019, aaron, Update, Cryo Q, Vent for many items IMG_20190220_160032.jpgUntitled.jpg
    Reply  Fri Feb 22 11:52:05 2019, aaron, Update, Cryo Q, Vent for many items 
       Reply  Sun Feb 24 17:37:50 2019, aaron, Update, Cryo Q, Vent for many items 
          Reply  Mon Feb 25 12:52:02 2019, aaron,ching pin, Update, Cryo Q, Vent for many items IMG_20190225_125401.jpgIMG_20190225_125525.jpg
             Reply  Tue Feb 26 17:08:59 2019, aaron,ching pin, Update, Cryo Q, Vent for many items 6x
                Reply  Tue Feb 26 19:38:48 2019, aaron, Update, Cryo Q, Vent for many items 
Entry  Mon Feb 25 20:45:10 2019, Koji, Misc, material properties, Si Block stored in Cryo Lab 
Entry  Fri Feb 22 11:57:05 2019, aaron, Electronics, Temperature Sensing, New temperature sensing board for 1k RTDs Screen_Shot_2019-02-22_at_12.13.06_PM.png
    Reply  Fri Feb 22 12:20:23 2019, aaron, Electronics, Temperature Sensing, New temperature sensing board for 1k RTDs 
Entry  Thu Jan 3 14:44:06 2019, aaron, Update, Cryo Q, Cryo lab is back! 
    Reply  Fri Jan 4 19:26:06 2019, aaron, Update, Cryo Q, Cryo lab is back! 9D2E88AB-2761-41EA-AB0C-359F8C196F61.jpeg3A4C209C-4DE6-4A90-8E88-8C205FA6A5E2.jpegDD55BD26-F01A-4541-9E48-4CF44F9A7362.jpeg
       Reply  Mon Jan 7 19:42:20 2019, aaron, Update, Cryo Q, Cryo lab is back! 
          Reply  Tue Jan 8 11:07:32 2019, aaron, Update, Cryo Q, Cryo lab is back! 
             Reply  Wed Jan 9 11:10:25 2019, aaron, Update, Cryo Q, Cryo lab is back! A62766B1-EAB7-47F7-8C92-04C5A6FCA06A.jpeg46D5E02F-1850-4CAA-B08E-D593F3F4E947.jpeg
                Reply  Thu Jan 10 11:33:57 2019, aaron, Update, Cryo Q, Cryo lab is back! 
                   Reply  Thu Jan 10 21:15:27 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                      Reply  Mon Jan 14 11:13:54 2019, aaron, Update, Cryo Q, hard drive failure, reformatting CFED8A2C-4D7E-4095-B77D-77554BDE4622.jpeg49A640E0-E87A-4A25-A9C7-CF461FBEA8BE.jpeg1FD6124A-387D-429C-A091-56ABD5AE9DE4.jpeg
                         Reply  Mon Jan 14 19:57:08 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                            Reply  Tue Jan 15 15:19:17 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                               Reply  Wed Jan 16 13:41:06 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                  Reply  Wed Jan 16 17:30:16 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                     Reply  Thu Jan 17 14:52:14 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                        Reply  Fri Jan 25 17:13:23 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                           Reply  Sat Jan 26 14:28:47 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                              Reply  Tue Jan 29 17:01:38 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 3E68AA8B-62C0-4C7F-9117-2774AB0DC708.jpeg
                                                 Reply  Wed Jan 30 10:34:07 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                    Reply  Wed Jan 30 15:25:35 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                       Reply  Fri Feb 1 20:11:45 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                          Reply  Sat Feb 2 15:31:14 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                             Reply  Thu Feb 7 17:37:48 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                                Reply  Mon Feb 11 13:56:18 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                                   Reply  Tue Feb 12 14:12:29 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                                      Reply  Wed Feb 13 20:07:38 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
                                                                         Reply  Thu Feb 14 16:35:51 2019, aaron, Update, Cryo Q, hard drive failure, reformatting 
Entry  Thu Feb 7 16:20:19 2019, aaron, DailyProgress, Cryo Q, Cooldown, no heater 
    Reply  Thu Feb 7 17:18:51 2019, aaron, ching pin, DailyProgress, Cryo Q, Cooldown, no heater Screenshot_from_2019-02-07_17-17-48.png
       Reply  Sun Feb 10 13:52:06 2019, aaron, DailyProgress, Cryo Q, Cooldown, no heater 
          Reply  Mon Feb 11 13:26:17 2019, aaron, DailyProgress, Cryo Q, Cooldown, no heater Screenshot_from_2019-02-11_13-32-31.pngScreenshot_from_2019-02-11_15-50-10.png
Entry  Wed Feb 6 20:59:59 2019, aaron, ching pin, Update, Cryo Q, Another vent,  IMG_20190206_192616.jpgIMG_20190206_193247.jpgIMG_20190206_211533.jpg
Entry  Wed Feb 6 11:14:23 2019, aaron, Cryostat, Lab Work, A note on cryostat wiring 
Entry  Fri Feb 1 15:01:46 2019, ching pin, DailyProgress, , Status on current cooldown Screenshot_from_2019-02-01_15-14-59.png
    Reply  Fri Feb 1 19:15:24 2019, aaron, DailyProgress, , Status on current cooldown 
       Reply  Sat Feb 2 15:12:23 2019, aaron, DailyProgress, Cryo, Status on current cooldown 
          Reply  Mon Feb 4 13:35:26 2019, aaron, DailyProgress, , Status on current cooldown 
Entry  Thu Jan 31 18:05:28 2019, aaron, Things to Buy, Cryo Q, sapphire plano-convex lens? 
    Reply  Fri Feb 1 11:13:10 2019, aaron, Things to Buy, Cryo Q, sapphire plano-convex lens? 
Entry  Tue Jan 22 15:24:51 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
    Reply  Thu Jan 24 12:07:30 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
       Reply  Thu Jan 24 20:49:08 2019, ching pin, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
          Reply  Thu Jan 24 21:00:50 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
             Reply  Fri Jan 25 13:27:37 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                Reply  Fri Jan 25 15:23:36 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                   Reply  Sat Jan 26 15:33:46 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                      Reply  Sun Jan 27 21:04:23 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                         Reply  Mon Jan 28 19:38:15 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                            Reply  Tue Jan 29 11:12:46 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                               Reply  Tue Jan 29 16:59:10 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                                  Reply  Wed Jan 30 10:29:47 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                                     Reply  Wed Jan 30 20:43:46 2019, aaron, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                                        Reply  Thu Jan 31 10:11:35 2019, aaron, ching pin, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps 
                                           Reply  Thu Jan 31 14:28:18 2019, aaron, ching pin, Cryostat, Cryo Q, Vent for Wiring swap, sphere base heat straps IMG_20190131_140629.jpg
Entry  Wed Jan 30 16:39:17 2019, aaron, Update, Control System, Thoughts on, state of Qryo control loop Screen_Shot_2019-01-30_at_5.20.26_PM.pngScreen_Shot_2019-01-30_at_5.20.33_PM.pngScreen_Shot_2019-01-30_at_5.20.40_PM.pngScreen_Shot_2019-01-30_at_5.20.46_PM.pngScreen_Shot_2019-01-30_at_5.21.04_PM.png
Entry  Wed Jan 16 20:09:56 2019, awade, Lab Infrastructure, stuff happens, Borrowed Marconi 2023A (SN 202304/136) to PSL lab 
    Reply  Thu Jan 17 14:46:59 2019, anchal, Lab Infrastructure, stuff happens, Borrowed Marconi 2023A (SN 202304/136) to PSL lab 
Entry  Thu Jan 10 14:36:16 2019, aaron, DailyProgress, Cryo Q, Cooling down 
    Reply  Thu Jan 10 21:24:52 2019, aaron, DailyProgress, Cryo Q, Cooling down 
       Reply  Fri Jan 11 10:56:35 2019, aaron, DailyProgress, Cryo Q, Cooling down 
          Reply  Fri Jan 11 11:18:40 2019, aaron, DailyProgress, Cryo Q, Measuring Q Screenshot_from_2019-01-11_13-10-44.pngScreenshot_from_2019-01-11_12-54-28.png
             Reply  Mon Jan 14 14:00:09 2019, aaron, DailyProgress, Cryo Q, Measuring Q 
                Reply  Tue Jan 15 12:00:07 2019, aaron, DailyProgress, Cryo Q, Measuring Q 
                Reply  Wed Jan 16 10:52:54 2019, ching pin, DailyProgress, Cryo Q, Measuring Q 
                   Reply  Wed Jan 16 14:05:11 2019, aaron, DailyProgress, Cryo Q, Measuring Q 
                      Reply  Wed Jan 16 16:22:35 2019, aaron, DailyProgress, Cryo Q, Measuring Q 
                         Reply  Thu Jan 17 11:20:43 2019, aaron, DailyProgress, Cryo Q, Measuring Q excitation_parameters.pngcold_ringdown1.png
Entry  Thu Dec 20 17:13:27 2018, awade, Misc, General, Borrowed equipment: HP 8560E Spectrum Analyzer 
Entry  Mon Dec 3 16:03:14 2018, Rahul, Update, Si fab, fresh fab at KNI 12032018.jpg
Entry  Sun Nov 18 21:11:39 2018, rana, Computing, General, workstation gaston upgrades 
Entry  Sun Nov 18 20:47:07 2018, rana, Summary, HVAC, Its getting hot in here 2018-Temperatures-Lab.pdf
Entry  Tue Sep 18 17:02:13 2018, aaron, Electronics, Sensors, Blue QPD Evalu 
    Reply  Sun Oct 21 15:02:14 2018, aaron, Electronics, Sensors, Blue QPD Evaluation 
       Reply  Thu Oct 25 00:01:43 2018, aaron, Electronics, Sensors, Blue QPD Evaluation 1D4EFC3D-E6E3-404D-816D-E07356B8FA87.jpegBED2BF8C-DFC6-4F6B-A34D-959F9B628B96.jpeg
          Reply  Thu Oct 25 15:42:48 2018, aaron, Electronics, Sensors, Blue QPD Evaluation 37_PM.png
       Reply  Tue Nov 13 18:27:27 2018, aaron, Electronics, Sensors, Blue QPD Evaluation 
Entry  Tue Nov 6 11:28:11 2018, Rahul, Update, , KNI fabrication scribe_and_break.pngKOH_etching.jpg
Entry  Fri Oct 19 17:35:25 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs manymoderingers.pngScreenshot_from_2018-09-24_17-50-20.png08_PM.png587277D1-595E-47D7-B969-4E8040394F00.jpegimage.jpg
    Reply  Sun Oct 21 13:07:57 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 30_PM.png59_PM.png06_PM.png09_PM.png
       Reply  Mon Oct 22 12:59:18 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 
          Reply  Tue Oct 23 10:30:15 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 7x
             Reply  Wed Oct 24 12:01:55 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 11_PM.png398963AD-2354-4ADA-A23E-B91BD486E38D.jpeg
                Reply  Thu Oct 25 10:40:57 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 
                   Reply  Mon Oct 29 11:46:43 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 6x
                      Reply  Tue Oct 30 11:43:27 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 53_PM.png
                         Reply  Tue Oct 30 15:04:33 2018, rana, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 
                            Reply  Tue Oct 30 15:59:42 2018, aaron, Update, Cryo Q, Tracking RTD Temperature, Disk Temperature, and Qs 
                               Reply  Wed Oct 31 15:49:25 2018, aaron, Update, Cryo Q, HIGH Qs 24_PM.png35_PM.png
                                  Reply  Wed Oct 31 19:03:11 2018, rana, Update, Cryo Q, HIGH Qs 
                                  Reply  Wed Oct 31 21:25:18 2018, aaron, Update, Cryo Q, HIGH Qs Screen_Shot_2018-10-31_at_10.47.10_PM.png
Entry  Wed Oct 31 16:10:13 2018, Rahul, Update, , fab of silicon wafer Schematic_of_fabrication_process.jpg
Entry  Thu Mar 1 11:48:45 2018, aaron, Update, Temperature Sensing, Estimate of required temperature resolution Screen_Shot_2018-03-01_at_11.41.18_AM.png
    Reply  Thu Mar 1 23:30:01 2018, aaron, Update, Temperature Sensing, Estimate of required temperature resolution Screen_Shot_2018-03-01_at_11.28.50_PM.pngScreen_Shot_2018-03-01_at_11.36.46_PM.png
       Reply  Fri Mar 2 04:51:57 2018, rana, Update, Temperature Sensing, Estimate of required temperature resolution 
          Reply  Tue Oct 30 18:29:36 2018, aaron, Update, Temperature Sensing, Estimate of required temperature resolution 
             Reply  Wed Oct 31 10:30:17 2018, aaron, Update, Temperature Sensing, Estimate of required temperature resolution 
Entry  Wed Oct 24 10:43:45 2018, johannes, Noise Hunting, Noise Budget, noise hunting brain dump Screenshot_from_2018-10-24_10-57-31.png
Entry  Mon Nov 27 23:22:06 2017, aaron, Misc, Temperature Sensing, Temperature readout and control board SiQTempBoard.pdftempControl.pdf
    Reply  Tue Nov 28 08:25:32 2017, brittany, Misc, Temperature Sensing, Temperature readout and control board 
    Reply  Tue Nov 28 13:55:59 2017, Koji, Electronics, General, Temperature readout and control board 
    Reply  Mon Oct 22 00:58:44 2018, rana, Misc, Temperature Sensing, Temperature readout and control board 
       Reply  Mon Oct 22 12:48:47 2018, rana, Misc, Temperature Sensing, Temperature readout and control board 
Entry  Tue Oct 9 00:44:22 2018, johannes, Notes, Cryo ISS, New Transmission PDs and ISS 8x
    Reply  Thu Oct 11 01:25:43 2018, johannes, Notes, Cryo ISS, ISS Servo Characterization 7x
       Reply  Tue Oct 16 00:02:15 2018, johannes, Notes, Cryo ISS, ISS Servo Characterization planex_rin.pdf
Entry  Mon Sep 24 17:50:40 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning Screenshot_from_2018-09-24_17-50-20.png
    Reply  Tue Sep 25 18:17:54 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning IMG_8555.JPG
       Reply  Wed Sep 26 16:16:26 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
          Reply  Thu Sep 27 14:34:13 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning IMG_5880.jpeg
             Reply  Fri Sep 28 10:35:52 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
                Reply  Fri Sep 28 12:46:32 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
                   Reply  Sat Sep 29 11:18:22 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
                      Reply  Thu Oct 4 11:34:32 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning Screen_Shot_2018-10-04_at_11.48.23_AM.png
                         Reply  Thu Oct 4 21:16:32 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
                            Reply  Sat Oct 6 00:04:16 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
                               Reply  Sat Oct 6 14:54:06 2018, aaron, DailyProgress, Cryo Q, Qryo Qommissioning 
Entry  Fri Sep 28 07:56:15 2018, johannes, Photos, Laser,  
Entry  Fri Sep 14 10:50:30 2018, aaron, Cryostat, Cryo Q, Unboxing the new cryo 
    Reply  Tue Sep 18 10:24:26 2018, aaron, Cryostat, Cryo Q, Unboxing the new cryo 7x
       Reply  Thu Sep 20 10:38:10 2018, aaron, Cryostat, Cryo Q, Unboxing the new cryo IMG_3929.JPGUnboxing_1.zip
          Reply  Thu Sep 20 21:25:45 2018, aaron, Cryostat, Cryo Q, Unboxing the new cryo 180920_pumpdown.png
             Reply  Fri Sep 21 13:59:19 2018, aaron, Cryostat, Cryo Q, Unboxing the new cryo GeNS_2.0.jpgheaters.jpg
                Reply  Fri Sep 21 19:53:36 2018, aaron, Cryostat, Cryo Q, Unboxing the new cryo 180921_BakeVac.png
Entry  Wed Sep 12 10:15:12 2018, aaron, Update, Cryo Q, Using the Temperature Tracking Mode TempMode.pngbeatStriptool.pngLP10to1000.pngBeatFreqSpectrum.png
Entry  Sat Sep 8 02:45:04 2018, johannes, Electronics, Digital PLL, valon testing setup.pdfvalon.JPGrp_valon_961MHz_div32_2units_-34dBm_amp_to_-17dBm_f.pdfrp_valon_961MHz_div32_2units_-34dBm_amp_to_-17dBm_p.pdf
Entry  Thu Aug 30 23:33:57 2018, johannes, Computing, General, LISO plague 
Entry  Fri Aug 24 16:01:08 2018, aaron, Notes, Cryo Q, optimal op lev configuration 
    Reply  Mon Aug 27 23:56:29 2018, aaron, Notes, Cryo Q, optimal op lev configuration 180824_optimalOpLev.pdf
       Reply  Tue Aug 28 10:19:26 2018, aaron, Notes, Cryo Q, optimal op lev configuration 
          Reply  Tue Aug 28 13:27:32 2018, johannes, Notes, General, spanner wrenches 
       Reply  Tue Aug 28 16:43:25 2018, aaron, Notes, Cryo Q, optimal op lev configuration 180824_optimalOpLev.pdf
          Reply  Tue Aug 28 18:51:16 2018, aaron, Notes, , New optical configuration, high frequency modes, calibrated moderinger?? RealignedTF_10_3000.pngrealignedSpectrum.pngTempMode.png
Entry  Tue Aug 28 00:24:54 2018, aaron, Cryostat, Cryo Q, New Cryostat(s)! 
Entry  Sun Aug 26 21:24:01 2018, johannes, Update, Cryo,  6x
Entry  Sat Aug 25 17:30:28 2018, johannes, Lab Infrastructure, stuff happens, Down another Marconi 
Entry  Fri Aug 17 14:56:59 2018, aaron, Update, Cryo Q, Finding Modes InAirGeNSTF.png
    Reply  Mon Aug 20 22:03:26 2018, Mandy , Update, Cryo Q, Finding Modes 
       Reply  Mon Aug 20 23:40:29 2018, aaron, Update, Cryo Q, Finding Modes 180820_TFscan.png180820_kHzModeTF.png
          Reply  Tue Aug 21 11:29:30 2018, aaron, Update, Cryo Q, Finding Modes 
             Reply  Wed Aug 22 10:07:03 2018, aaron, Update, Cryo Q, Finding Modes 
                Reply  Wed Aug 22 13:17:19 2018, aaron, Computing, Cryo Q, timing error, rebuilding model 
                   Reply  Wed Aug 22 15:48:35 2018, aaron, Computing, Cryo Q, timing error, rebuilding model phase_rotator.png1kHzrindown.png
                      Reply  Thu Aug 23 11:14:19 2018, aaron, Computing, Cryo Q, rebuilding model, moderinger MRChain_woExcitation.pngMRChain_wExcitation.png
                   Reply  Wed Aug 22 21:55:02 2018, johannes, Computing, stuff happens, problem with x1cry filters 
Entry  Mon Jun 11 09:26:37 2018, Disha Kapasi, Update, General, Current Driver v2 and Frequency noise of the beat note Current_Driver_Circuit_-_v2.pdfnewbeatnote.pdf
    Reply  Tue Aug 14 23:21:01 2018, johannes, Update, General, Current Driver v2 20180814_160659.jpgn_channel_driver.PNGp_channel_driver.PNGvis_mods.pdf
       Reply  Wed Aug 15 23:34:38 2018, johannes, Update, General, Cooling down 
          Reply  Mon Aug 20 02:35:06 2018, johannes, Update, General, We're cool 
Entry  Fri Aug 17 10:38:01 2018, aaron, Summary, Vacuum, Outgassing rate of plastics 
Entry  Mon Aug 13 15:56:36 2018, aaron, Cryostat, Vacuum, New fill port blank ready to go IMG_1082.JPG
    Reply  Wed Aug 15 14:53:00 2018, aaron, Cryostat, Vacuum, New fill port blank ready to go IMG_3335.JPGIMG_9538.JPGIMG_5561.JPG
Entry  Thu Aug 9 11:13:19 2018, aaron, Things to Buy, Cryo Q, GeNS v2 
    Reply  Wed Aug 15 14:50:08 2018, aaron, Things to Buy, Cryo Q, GeNS v2 
Entry  Mon Aug 13 21:37:58 2018, aaron, Notes, Cryo Q, Temperature Sensitivity of Eigenfrequency Tracking 180813_eigenfreqTempSensitivity.pdf
Entry  Mon Jun 25 01:47:08 2018, johannes, Summary, Transfer Functions, amplitude modulation suppression in RF beat for PLL measurement of photothermal response RFamp_mod_20180623.pdfPcav_mod_20180623.pdffreq_mod_20180623.pdf
    Reply  Thu Jun 28 09:32:32 2018, johannes, Summary, Transfer Functions, measurement of photothermal response photothermal_20180212_nom.pdfphotothermal_20180212_alt.pdfphotothermal_20180623.pdf
       Reply  Thu Jun 28 11:21:32 2018, rana, Summary, Transfer Functions, measurement of photothermal response 
          Reply  Sun Aug 12 23:40:08 2018, johannes, Summary, Transfer Functions, measurement of photothermal response phth_both_scaled.pdfphth_both_fit.pdfphth_all_comparison_scaled.pdfphth_dual_unc.png
Entry  Wed Aug 8 14:57:48 2018, aaron, Update, Cryo Q, Update to SiQ model and MEDMs 
Entry  Mon Aug 6 09:28:25 2018, Izabella Pastrana, Update, Laser, Instrumentation Amplifier for Laser Current Noise Measurement Schematic_instrAmp_Sheet-1_20180806112153.pdfinstrAmp_LISOsim_noise.pdfinstrAmp_LISOsim_gain.pdf
Entry  Thu Aug 2 08:25:37 2018, Mandy , DailyProgress, Temperature Sensing, RTD Calibration Update  20180719_143416(1).jpg20180729_135549(1).jpg20180719_153220.jpg20180729_150906(1).jpg
Entry  Wed Aug 1 11:38:36 2018, aaron, mandy, DailyProgress, Temperature Sensing, progress on FSL 
    Reply  Wed Aug 1 18:58:53 2018, aaron, DailyProgress, Temperature Sensing, progress on FSL 
Entry  Tue Jul 24 18:16:19 2018, Aaron, DailyProgress, Cryo Q, Started aligning for in-air operation 
    Reply  Wed Aug 1 00:21:32 2018, Mandy, DailyProgress, Cryo Q, Started aligning for in-air operation 180801-laserLayout.PNG
Entry  Tue Jul 31 22:30:31 2018, aaron, mandy, Electronics, Lab Work, Temperature control circuit reboot 
Entry  Tue Jul 24 18:32:33 2018, aaron, Cryostat, Vacuum, Zach's dewars are no good FillPort_Blank.SLDDRWFillPort_Blank.SLDPRT
    Reply  Mon Jul 30 14:17:58 2018, johannes, Cryostat, Vacuum, Zach's dewars are no good 
       Reply  Tue Jul 31 22:21:40 2018, aaron, Cryostat, Vacuum, Zach's dewars are no good 
Entry  Sun Jul 29 18:12:44 2018, rana, Misc, Cleanliness, tool marking 
Entry  Sun Jul 29 17:59:26 2018, rana, Cryostat, Vacuum, texts 
Entry  Mon Jul 23 16:44:59 2018, johannes, Notes, DAQ, Red Pitaya PSA 
Entry  Mon Jul 23 16:35:55 2018, johannes, Computing, DAQ, increased logging rate of DQ channels for cryocavs 
Entry  Thu Jun 28 23:19:49 2018, johannes, Disha, Notes, Cavity, Gaussian beam mode for the new cavities New_Cavities.pdf
    Reply  Sun Jul 1 23:19:25 2018, johannes, Notes, Cavity, Gaussian beam mode for the new cavities 6x
       Reply  Tue Jul 3 11:58:25 2018, johannes, Notes, Cavity, Gaussian beam mode for the new cavities cavity_support_ring_gen2_15deg.PDFcavity_support_shelf.PDFshelf__contacts.pngcyl__contacts.png
          Reply  Wed Jul 11 22:38:54 2018, johannes, Notes, Cavity, Some assembly required 20180706_212353.jpg20180706_202052.jpg
             Reply  Wed Jul 11 23:27:38 2018, johannes, Notes, Cavity, new breadboard assembly 20180710_143617.jpg20180710_143629.jpg20180710_145112.jpg20180710_163221.jpg20180710_163803.jpg
                Reply  Wed Jul 11 23:51:18 2018, johannes, Notes, Cavity, first light 
                   Reply  Thu Jul 19 23:19:01 2018, johannes, Summary, Cavity, cryostat closed and pumping 20180719_114735.jpg20180717_164839.jpg
                      Reply  Sun Jul 22 00:52:10 2018, johannes, Summary, Cavity, transmission paths set up, mode-matching improved, post-baking ringdowns 6x
Entry  Sat Jul 7 13:32:34 2018, Disha Kapasi, Misc, General, VDO360 Camera VDO360_camera.pdfSample.pdf
Entry  Mon Jul 2 20:00:59 2018, awade, Lab Infrastructure, stuff happens, Added SR785 prologix to cryo network 
    Reply  Mon Jul 2 20:31:30 2018, johannes, Lab Infrastructure, stuff happens, Added SR785 prologix to cryo network 
Entry  Wed Jun 27 09:46:46 2018, Aaron, DailyProgress, Temperature Sensing, RTD Calibration 
    Reply  Fri Jun 29 08:44:04 2018, Mandy , DailyProgress, Temperature Sensing, RTD Calibration 
Entry  Thu Jun 28 23:47:56 2018, Disha Kapasi, Update, Cryo, Fractional change in length of the cavity at 123 K due to external modulation cross-correlated.pdf
Entry  Thu Jun 28 17:08:45 2018, awade, Misc, stuff happens, Borrowed N2 ion rig 
Entry  Thu Jun 28 16:39:48 2018, aaron, Cryostat, Vacuum, Zach's dewars are no good 
Entry  Thu Jun 28 14:31:41 2018, Mandy , Misc, , Lock-In Amplifier Notes  
Entry  Wed Jun 27 16:01:49 2018, izabella, DailyProgress, Transfer Functions, Transfer Function Measurements on a Low-Pass Filter TFAG4395A_26-06-2018_092816_TFdist.pdf
Entry  Mon Jun 25 14:28:51 2018, aaron, Cryostat, Vacuum, dewars still busted 
Entry  Thu Jun 21 19:07:10 2018, aaron, Things to Buy, Temperature Sensing, glass heaters 
Entry  Wed Jun 20 10:42:52 2018, aaron, Cryostat, Cryo Q, Cryo swap Zryo_initialFit_beam.PDFZryo_initialFit_sectionBeam.PDF
    Reply  Thu Jun 21 17:35:10 2018, aaron, Cryostat, Cryo Q, Cryo swap 
Entry  Thu Jun 21 15:38:00 2018, Disha Kapasi, Electronics, Noise Budget, LISO Analysis for PD C30642 1k.pdf3k.pdfOPAMP_Comparison.pdfPDISS.pdf
Entry  Wed Jun 20 02:10:59 2018, johannes, Notes, DAQ, Marconi PLL including frequency tracker a la CC set up for CryoCavs slow_beat_mon.pngcry_beat_fast_mon.png
    Reply  Thu Jun 21 01:40:25 2018, johannes, Notes, DAQ, Marconi PLL including frequency tracker a la CC set up for CryoCavs coldwarm_comp_20180620.pdf
Entry  Tue Jun 19 10:15:54 2018, Disha Kapasi, Computing, Control System, Temperature control shceme on the MEDM screen medm_tempreadout.png
Entry  Sat Jun 16 22:45:31 2018, rana, Summary, SiFi - ringdown, Moderinger: commissioning the MR4 servo for the 497 Hz mode of the current cantilever mr4.pngModeRinger4-performance.png
Entry  Sat Jun 16 22:43:41 2018, rana, Computing, General, gaston/cymac1 has emacs 
Entry  Wed Jun 14 17:49:44 2017, Chris, Computing, DAQ, cymac restart procedure 
    Reply  Sat Jun 16 19:31:17 2018, rana, Computing, DAQ, cymac restart procedure GDS-FEs.png
Entry  Wed May 30 01:57:20 2018, johannes, Noise Hunting, Noise Budget, Substrate Carrier Density Noise Clarification carrier_density_illustration.pdfcd_length_noise_single.pdfcd_noise_beat_trans.pdf
    Reply  Wed May 30 18:40:17 2018, rana, Noise Hunting, Noise Budget, Substrate Carrier Density Noise Clarification 
       Reply  Wed May 30 22:24:33 2018, johannes, Noise Hunting, Noise Budget, Substrate Carrier Density Noise Clarification cryolab_CD.ipynb.tar.gzvoyager_strain_noise.pdfcd_length_noise_single.pdfcd_noise_beat_trans.pdf
          Reply  Fri Jun 15 00:11:51 2018, johannes, Noise Hunting, Noise Budget, Substrate Carrier Density Noise Clarification Cavityland_in_Patrick!_The_Game.pngvoyager_strain_noise.pdfcd_length_noise_single.pdfcd_noise_beat_trans.pdfcryolab_CD.ipynb.tar.gz
Entry  Mon Jun 11 23:04:58 2018, Disha Kapasi, Update, General, Thermal diffusion constant and thermal wavelength 
    Reply  Wed Jun 13 11:12:09 2018, johannes, Update, General, Thermal diffusion constant and thermal wavelength 
Entry  Mon Jun 11 22:29:58 2018, Disha Kapasi, Notes, Temperature Sensing, Recalculating temperature readout noise 
Entry  Sat Jun 9 06:47:06 2018, Disha Kapasi, Update, Optics, Transmission and Reflection Coefficient 
    Reply  Sat Jun 9 16:46:49 2018, rana, Update, Optics, Transmission and Reflection Coefficient 
Entry  Thu Jun 7 23:36:46 2018, Disha Kapasi, Update, Optics, Transmission and Reflection Coefficient T_and_R_Coefficient_Measurement.pdf
    Reply  Fri Jun 8 01:59:32 2018, johannes, Update, Optics, Transmission and Reflection Coefficient 
Entry  Fri Jun 8 00:11:27 2018, johannes, Update, Lab Work, optical setup reloaded CRYO_SETUP.pdfaom_response_20180605.pdf
Entry  Thu Jun 7 23:29:35 2018, Disha Kapasi, Update, General, Right units for the Bode plot TF_Schematic.pdftf.pdf
Entry  Wed Jun 6 12:21:11 2018, Disha Kapasi, DailyProgress, Cavity, Response of the Si Cavity to external modulation freqn_beatnote.pdf
Entry  Fri Jun 1 15:43:12 2018, Steve, Update, Cryo, cryostat 140 repair misaligned140.jpg140bended.jpg140.jpgd#140leak.jpg
    Reply  Wed Jun 6 10:12:09 2018, Steve, Update, Cryo, cryostat 140 repair effort failed 
Entry  Mon Jun 4 19:56:30 2018, Disha Kapasi, Update, General, Current Driver Current_Driver.pdfIntegrated_Driver.pdfRIN.pdfTF.pdf
    Reply  Tue Jun 5 18:10:54 2018, rana, Update, General, Current Driver 
Entry  Tue Jun 5 16:25:17 2018, brittany, aaron, DailyProgress, Cryo Q, Temperature testing setup 
Entry  Sat Jun 2 00:18:21 2018, johannes, Computing, General, epics install on cryoaux 
    Reply  Sat Jun 2 16:09:46 2018, johannes, Computing, General, fe models not working 
       Reply  Mon Jun 4 16:57:21 2018, johannes, Computing, General, fe models not working 
Entry  Thu May 17 22:27:06 2018, Disha Kapasi, DailyProgress, Temperature Sensing, Temperature readout scheme Temperature_Readout_Scheme.pdf
    Reply  Wed May 23 22:55:52 2018, rana, DailyProgress, Temperature Sensing, Temperature readout scheme 
Entry  Sun May 6 23:48:24 2018, johannes, Update, Optics, misc optical table things IMG_20180503_174406600_HDR.jpg
    Reply  Mon May 7 23:04:26 2018, johannes, Update, PDH, servo mods beatnoise_20180507.pdfOLGs_20180507.pdf
       Reply  Wed May 9 00:02:52 2018, johannes, Update, Beat Spectrum, scatter be gone pickoff_beatnoise_20180508.pdfHWP_placement.pdftransfront_comp_20180508.pdf
          Reply  Fri May 11 22:46:55 2018, johannes, Update, Beat Spectrum, modPDH input referred noise 6x
             Reply  Tue May 15 09:36:05 2018, johannes, Update, Beat Spectrum, comparison with marconi and cross-correlation attempts marconi_vs_rp_20180512.pdfcorr_time_series_20180512.pdfcross-corr_20180512.pdf
                Reply  Tue May 15 10:33:55 2018, johannes, Update, Beat Spectrum, refl pd dark noise dark_noise_20180513.pdf
                   Reply  Wed May 16 22:21:53 2018, johannes, Update, Sensors, new photodiode installed in west REFL PD case 
                      Reply  Fri May 18 01:43:10 2018, johannes, Update, Sensors, re-tuned rfpds rfpd_response_20180517_full.pdfrfpd_response_20180517_res.pdfrfpds_20180517.tar.gz
                         Reply  Wed May 23 01:03:35 2018, johannes, Update, Sensors, rfpds diplexer.png
                Reply  Wed May 16 23:59:17 2018, johannes, Update, PDH, servo box again 8x
Entry  Sun May 6 23:41:51 2018, johannes, Lab Infrastructure, Purchases, label maker cartridges IMG_20180503_114955325.jpgIMG_20180503_144005899.jpg
Entry  Sun Mar 25 15:07:23 2018, johannes, Summary, Optics, 8cm ROC Si mirror investigation 1 13x
    Reply  Sun Mar 25 15:52:50 2018, johannes, Summary, Optics, 8cm ROC Si mirror investigation 2 IMG_20180321_181337601.jpgIMG_20180322_174539959.jpgringdown1.pngcavity_ringdowns_20180322.pdf
       Reply  Mon Mar 26 11:07:31 2018, rana, Summary, Optics, ringdowns 
          Reply  Mon Mar 26 22:20:36 2018, johannes, Summary, Optics, ringdowns ringdown_EOAM_connect3.pngcavity_ringdowns_20180326.pdfchopped_0dB.pngtrans_chopped_60dB.png
             Reply  Tue Mar 27 21:44:23 2018, rana, Summary, Optics, ringdowns 
                Reply  Wed Mar 28 00:55:59 2018, johannes, Summary, Optics, ringdowns intrinsic_noise.pdfcavity-ringdown.tar.bz2
                   Reply  Thu Mar 29 22:53:01 2018, johannes, Summary, Optics, Si cavity assembly IMG_20180329_161459581.jpg
                      Reply  Sat Mar 31 13:15:34 2018, johannes, DailyProgress, Optics, Will it bond? spacer-pair.jpgweight-assist.jpgcentering-before.jpgcentering-after.jpg
                         Reply  Thu Apr 19 00:04:30 2018, johannes, DailyProgress, Optics, Will it bond? curing_jig.jpg
                            Reply  Tue Apr 24 20:47:02 2018, johannes, DailyProgress, Optics, Short-lived short cavity IMG_20180424_102550056.jpgIMG_20180424_135830137.jpg
                               Reply  Wed Apr 25 18:59:40 2018, johannes, DailyProgress, Optics, first short cavity assembled IMG_20180425_184159128.jpgIMG_20180425_102658794.jpg
                                  Reply  Tue May 1 00:15:27 2018, johannes, DailyProgress, Optics, second short cavity assembled jig-upright.jpgbaking_jig.jpg
Entry  Wed Apr 18 16:52:48 2018, rana, Misc, General, temperature 
    Reply  Wed Apr 18 20:00:36 2018, johannes, Misc, General, temperature labtemp_trend.png
       Reply  Sat Apr 21 16:59:04 2018, johannes, Misc, General, temperature 
          Reply  Mon Apr 23 10:07:07 2018, johannes, Misc, HVAC, lab temperature 
             Reply  Tue Apr 24 11:42:11 2018, johannes, Misc, HVAC, lab temperature 
                Reply  Thu Apr 26 22:13:13 2018, johannes, Misc, HVAC, lab temperature EPICS channel added AD590_readout.PNGtemp_trend_first_hour.png
                   Reply  Mon Apr 30 10:40:51 2018, johannes, Misc, HVAC, lab temperature EPICS channel added Screenshot_from_2018-04-30_10-40-17.png
Entry  Wed Apr 25 15:38:09 2018, aaron and brittany, Cryostat, Vacuum, overpressure test IMG_3866.jpgIMG_3865.jpgIMG_3864.jpgIMG_3863.jpg
Entry  Thu Apr 12 10:34:52 2018, johannes, Notes, Optics, Polarization mystery polarization_mystery.pdf
    Reply  Fri Apr 13 00:07:39 2018, johannes, Notes, Optics, Stress-induced birefringence in windows and cavity mirrors 
       Reply  Thu Apr 19 21:58:21 2018, johannes, Notes, Optics, Stress-induced birefringence in windows and cavity mirrors waveplate_moved.jpg
          Reply  Sat Apr 21 10:47:28 2018, johannes, Update, Optics, cleaned AR-sides of old cavities 
             Reply  Tue Apr 24 20:23:55 2018, johannes, Update, Optics, breadboard re-suspended, cryostat closed and pumping 
Entry  Fri Apr 20 09:14:50 2018, johannes, Notes, Cryo, cryostat inside notes cryostat_connectors_labeled.jpg
Entry  Sun Apr 15 21:48:23 2018, johannes, Update, Beat Spectrum, cold cavity characterization beatnoise_clean_20180413.pdfphotothermal_20180413.pdf
Entry  Fri Apr 13 09:46:06 2018, johannes, Computing, DAQ, Real-time system DAC crash Screenshot_from_2018-04-13_09-47-09.png
    Reply  Fri Apr 13 15:55:12 2018, Chris, Computing, DAQ, Real-time system DAC crash 
Entry  Wed Apr 11 15:58:34 2018, aaron, DailyProgress, Vacuum, overpressure test 
Entry  Tue Apr 10 14:23:06 2018, brittany, DailyProgress, Cryo Q, git vortex 
    Reply  Wed Apr 11 09:08:00 2018, rana, DailyProgress, Cryo Q, git vortex 
Entry  Mon Mar 19 12:22:39 2018, johannes, Cryostat, Cryo, Cryo Cavs Cooling Cycle Commenced cryostat_filling_valves.pngIMG_20180319_105103276.jpg
    Reply  Tue Mar 20 10:47:42 2018, johannes, Cryostat, Cryo, Cryo Cavs Cooling Cycle Commenced cooldown_20180319.pngScreenshot_from_2018-03-23_18-37-08.png
       Reply  Thu Mar 29 23:15:11 2018, johannes, DailyProgress, Beat Spectrum, lasers aligned to cold cavities, west servo busted 
          Reply  Mon Apr 2 23:54:38 2018, johannes, DailyProgress, Beat Spectrum, west PDH servo repair, west current driver repair, fast trans beat PD install IMG_20180331_143339265.jpgD1500207_CurrentDriver.jpget3010.jpget3010b.jpgnewport-818-BB-30.jpg
             Reply  Wed Apr 4 21:51:44 2018, johannes, DailyProgress, Beat Spectrum, high bandwidth pd testing 7x
                Reply  Tue Apr 10 00:50:45 2018, johannes, DailyProgress, Beat Spectrum, beat note trend beat_drift.png
Entry  Thu Apr 5 15:28:38 2018, Zach, Update, SiFi - ringdown, Newest hole cantilevers RT Q = ~80k 20180329_173458.jpg20180403_224213.jpg20180403_221352.jpg20180403_204021.jpg20180404_005324.jpg
Entry  Thu Apr 5 15:23:10 2018, Zach, Update, Si fab, New cantilevers made (hole and no-hole) 20180329_173409.jpg20180329_173434.jpg
Entry  Thu Apr 5 14:16:00 2018, johannes, Computing, General, spirou rebooted 
Entry  Wed Apr 4 09:59:33 2018, brittany, DailyProgress, Cryo Q, comparison plots VacuumBaselineComparisons.pdf
Entry  Tue Apr 3 17:24:00 2018, aaron, DailyProgress, Temperature Sensing, New heater for SIQ newHeaterconfig.png
    Reply  Tue Apr 3 20:45:20 2018, rana, DailyProgress, Temperature Sensing, New heater for SIQ 
Entry  Tue Apr 3 12:55:24 2018, brittany, Summary, Cryo Q, Qryo git repo on gaston 
Entry  Mon Apr 2 14:57:03 2018, brittany, aaron, DailyProgress, Cryo Q, vacuum baseline testing 180402_pumpdown_gaugeOnly.png
Entry  Fri Mar 30 14:35:45 2018, aaron, DailyProgress, Cryo, looking for this leak 
Entry  Sat Feb 17 12:49:31 2018, Zach, Update, SiFi, Dummy cantilever cavity locked in air 6x
    Reply  Tue Feb 20 02:00:04 2018, Zach, Update, SiFi, Payload suspended in air; first spectrum (control) suspended_dummycantcav.jpgTEK00007.TIFTEK00008.TIFSiFi_dummycantcav_ctrl_noise_2_19_18.png
       Reply  Thu Feb 22 21:26:33 2018, Zach, Update, SiFi, Twin cantilever cavities locked in vacuum firstcontact.jpgnew_bonded_mirror_cantilevers.jpgnew_payload_suspended.jpgSiFi_dummycantcav_vac_Ectrl_noise_2_21_18.png
          Reply  Mon Feb 26 15:26:50 2018, Zach, Update, SiFi, Dummy cantilever cavity first vacuum beat SiFi_dummycantcav_beat_noise_2_24_18.png
             Reply  Mon Feb 26 22:05:51 2018, Zach, Update, SiFi, *May* be seeing some dummy cantilever thermal noise 110Hz.png1kHz.pngSiFi_dummycantcav_beat_noise_w_thermal_noise_estimate_2_26_18.png
                Reply  Wed Feb 28 10:25:45 2018, Zach, Update, SiFi, Dummy cantilever thermal noise uncovered with table floating SiFi_dummycantcav_beat_noise_floating_w_thermal_noise_estimate_2_27_18.png
                   Reply  Wed Feb 28 23:23:11 2018, Zach, Update, SiFi, Analysis of noise in current state; path forward SiFi_dummycantcav_beat_noise_current_and_future_thermal_noise_2_28_18.pngSiFi_cantilever_mechTF_comparison_2_28_18.png
                      Reply  Wed Mar 7 11:59:33 2018, Zach, Update, SiFi, Mount noise test cavity mounttest_layout_traced.jpgmounttest_polaris_3_6_18.png
                         Reply  Thu Mar 22 20:10:24 2018, Zach, Update, SiFi, 180-Hz peak could be from blade spring bending mode 2Hz.png243Hz.png737Hz.png1515Hz.png
                            Reply  Fri Mar 23 17:59:25 2018, rana, Update, SiFi, 180-Hz peak could be from blade spring bending mode 
                      Reply  Tue Mar 13 10:55:29 2018, Zach, Update, SiFi, Custom mirror holder concept 6x
                         Reply  Fri Mar 16 01:30:31 2018, Zach, Update, SiFi, Mature draft of custom mirror holder part (quote pending) Screen_Shot_2018-03-16_at_1.21.04_AM.pngScreen_Shot_2018-03-16_at_1.21.49_AM.pngScreen_Shot_2018-03-16_at_1.19.54_AM.pngScreen_Shot_2018-03-16_at_1.19.35_AM.png
                            Reply  Wed Mar 21 18:06:50 2018, Zach, Update, SiFi, Mirror holder part ordered (also an extra clamp) 
                               Reply  Wed Mar 28 20:22:54 2018, Zach, Update, SiFi, Mirror holder part (and third cantilever clamp) received 6x
Entry  Tue Mar 20 17:19:55 2018, johannes, HowTo, General, Posting videos to elog elog_videos.png
Entry  Tue Mar 6 21:48:33 2018, johannes, Update, Beat Spectrum, Scaling error in RedPitaya scripts factor2.pngtumblr_mi0xapXg5q1rwax7go1_250.giftumblr_mi0xapXg5q1rwax7go4_250.gif
    Reply  Mon Mar 19 11:38:37 2018, johannes, Update, Digital PLL, Scaling error in RedPitaya scripts 
Entry  Wed Mar 14 19:27:39 2018, aaron, Cryostat, Vacuum, messing with the vacuum 
Entry  Fri May 20 19:23:12 2016, Johannes, Things to Buy, Cavity, Spacer quotes 
    Reply  Wed May 25 00:25:31 2016, Johannes, Things to Buy, Cavity, Mirror quotes 
       Reply  Thu Jun 30 10:52:24 2016, Johannes, Things to Buy, Cavity, Mirror quotes 
          Reply  Sat Aug 20 18:39:53 2016, Johannes, Things to Buy, Cavity, Mirror quotes 
             Reply  Tue Feb 13 23:27:28 2018, Johannes, Things to Buy, Cavity, New cavities 
                Reply  Tue Mar 13 22:08:29 2018, johannes, Things to Buy, Cavity, New cavities! 
Entry  Tue Mar 13 21:31:06 2018, johannes, Misc, Sensors, particle counter temperature channel 
Entry  Mon Mar 12 21:24:14 2018, aaron, Cryostat, Vacuum, Tracking down a leak 
Entry  Mon Mar 12 13:33:51 2018, aaron, Lab Infrastructure, DAQ, restarting slow epics channels 
Entry  Wed Mar 7 19:24:25 2018, aaron, DailyProgress, Cryo Q, Temperature sensing in Hi'iaka 
    Reply  Thu Mar 8 14:39:05 2018, aaron, DailyProgress, Cryo Q, Temperature sensing in Hi'iaka 
Entry  Thu Mar 8 10:34:18 2018, brittany, DailyProgress, Cryo Q, back on the elog train 
Entry  Wed Mar 7 21:25:10 2018, aaron, Update, DAQ, weird beep 
    Reply  Thu Mar 8 09:52:58 2018, johannes, Update, DAQ, weird beep 
       Reply  Thu Mar 8 10:10:19 2018, aaron, Update, DAQ, weird beep 
Entry  Thu Mar 1 22:12:47 2018, aaron, DailyProgress, Temperature Sensing, PID update Screenshot_from_2018-03-01_22-23-50.png
    Reply  Tue Mar 6 22:08:36 2018, aaron, DailyProgress, Temperature Sensing, PID update Screen_Shot_2018-03-06_at_10.24.01_PM.png
       Reply  Wed Mar 7 02:51:51 2018, rana, DailyProgress, Temperature Sensing, PID update 
          Reply  Wed Mar 7 08:30:58 2018, aaron, DailyProgress, Temperature Sensing, PID update Screen_Shot_2018-03-07_at_8.36.50_AM.pngScreen_Shot_2018-03-07_at_8.37.13_AM.pngScreen_Shot_2018-03-07_at_8.37.32_AM.png
Entry  Tue Nov 14 00:51:22 2017, johannes, Noise Hunting, Noise Budget, Beat noise with budget - at last (though incomplete) beat_noise_all.pdf
    Reply  Wed Nov 15 15:58:51 2017, rana, Noise Hunting, Noise Budget, Beat noise with budget - at last (though incomplete) 
    Reply  Tue Feb 13 23:06:20 2018, johannes, Noise Hunting, Noise Budget, I-Gain in east temp servo was too high rp_free_running_beatnoise_20180213.pdfplanex_datasheet.png
       Reply  Wed Feb 14 22:06:04 2018, johannes, Noise Hunting, Laser, noise bump originates in custom current driver driver_comp_20180214.pdflaser_driver_current_noise_20180214.pdflaser_driver_current_noise_20180214_setpoints.pdf
          Reply  Fri Feb 16 22:49:39 2018, johannes, Noise Hunting, Laser, noise bump originates in custom current driver current_driver_marked.png
             Reply  Thu Feb 22 01:44:03 2018, johannes, Noise Hunting, Laser, noise bump originates in custom current driver spice_screen.PNGLCD_upgrade_evo.pdf
                Reply  Fri Feb 23 10:38:41 2018, johannes, Noise Hunting, Laser, slight improvement of noise bump driver_comp_20180222.pdf
                   Reply  Sun Feb 25 01:12:20 2018, johannes, Noise Hunting, Laser, slight improvement of noise bump rp_beatnoise.pdf
                      Reply  Wed Feb 28 00:13:32 2018, johannes, Noise Hunting, Laser, free-running beat noise out to 10 MHz post-mod_delay-line_20180227.pdf
                         Reply  Tue Mar 6 20:51:49 2018, johannes, Noise Hunting, Laser, beat noise and loop gain free-lock_comp.pdfloop_tfs_20180301.pdf
Entry  Tue Mar 6 19:00:18 2018, aaron, DailyProgress, Optical Contacting, Hi'iaka electronics wired up IMG_3540.jpgIMG_3541.jpgIMG_3542.jpgwiresflipped.jpg
    Reply  Tue Mar 6 20:07:23 2018, aaron, DailyProgress, Optical Contacting, Hi'iaka electronics wired up 
Entry  Thu Mar 1 19:53:37 2018, aaron, Lab Infrastructure, DAQ, Possible framebuilder problem Screenshot_from_2018-03-01_19-48-40.pngScreenshot_from_2018-03-01_19-53-03.png
    Reply  Thu Mar 1 20:57:31 2018, aaron, Lab Infrastructure, DAQ, Possible framebuilder problem Screenshot_from_2018-03-01_20-59-18.png
       Reply  Fri Mar 2 12:57:23 2018, Chris, Lab Infrastructure, DAQ, Possible framebuilder problem 
Entry  Wed Feb 28 11:23:48 2018, Zach, Update, Si fab, Two more 4" wafers coated for cantilever fab two_more_wafers.jpg
Entry  Tue Feb 27 08:54:40 2018, Chris, Cryostat, Cryo, Cryogenic glue, epoxy, varnish etc. 
Entry  Tue Feb 20 23:28:40 2018, Zach, Summary, SiFi, Radiation pressure control of cantilever motion 
    Reply  Thu Feb 22 22:02:16 2018, Zach, Summary, SiFi, Radiation pressure control works extremely well in vacuum RP_excitation_timeseries.TIF
    Reply  Sat Feb 24 07:01:26 2018, rana, Summary, SiFi, Why is the ModeRinger better than a bunch of Ringdowns? 
       Reply  Mon Feb 26 16:46:43 2018, Zach, Summary, SiFi, Why is the ModeRinger better than a bunch of Ringdowns? 
          Reply  Mon Feb 26 20:49:23 2018, aaron, Summary, SiFi, Why is the ModeRinger better than a bunch of Ringdowns? 
             Reply  Mon Feb 26 21:57:40 2018, Zach, Summary, SiFi, Why is the ModeRinger better than a bunch of Ringdowns? 
Entry  Sat Feb 24 14:48:52 2018, aaron, DailyProgress, Temperature Sensing, Circuit works 
    Reply  Sat Feb 24 21:12:56 2018, rana, DailyProgress, Temperature Sensing, Acromag ADC noise 
       Reply  Mon Feb 26 20:55:05 2018, aaron, DailyProgress, Temperature Sensing, Acromag ADC noise 
Entry  Thu Feb 22 11:52:24 2018, aaron, DailyProgress, Cryo Q, temperature readout circuit 
    Reply  Mon Feb 26 14:48:56 2018, aaron, DailyProgress, Cryo Q, temperature readout circuit 
Entry  Thu Jan 11 21:22:21 2018, aaron, DailyProgress, Temperature Sensing, Heat balance, temperature sensors, schwarzschild heat_balance.jpgheatBalanceEstimates.pdf
    Reply  Fri Jan 12 10:11:38 2018, johannes, DailyProgress, Temperature Sensing, Black anodized aluminum in vacuum 
       Reply  Fri Jan 12 14:51:45 2018, aaron, DailyProgress, Temperature Sensing, Black anodized aluminum in vacuum 
          Reply  Sat Jan 20 16:02:52 2018, rana, HowTo, Cleanliness, Black anodized aluminum in vacuum 
    Reply  Sun Feb 25 06:20:46 2018, rana, DailyProgress, Temperature Sensing, emissivity of silicon 
       Reply  Mon Feb 26 06:54:05 2018, aaron, DailyProgress, Temperature Sensing, emissivity of silicon 
          Reply  Mon Feb 26 08:15:49 2018, rana, Summary, Temperature Sensing, emissivity of silicon CooldownDisk.pdf
Entry  Mon Feb 19 09:14:04 2018, aaron, Lab Infrastructure, HVAC, Lab is getting hot... 
Entry  Tue Feb 6 14:11:26 2018, aaron, DailyProgress, Cryo Q, Temperature control update 
    Reply  Wed Feb 7 13:20:25 2018, aaron, DailyProgress, Cryo Q, Temperature control update 
       Reply  Thu Feb 8 10:40:14 2018, aaron, DailyProgress, Cryo Q, Temperature control update 
          Reply  Fri Feb 9 13:40:39 2018, aaron, DailyProgress, Cryo Q, Temperature control update 48_PM.png
             Reply  Sat Feb 10 13:09:13 2018, aaron, DailyProgress, Cryo Q, Temperature control update IMG_3380.jpgIMG_3379.jpg
                Reply  Sat Feb 10 15:58:23 2018, Koji, DailyProgress, Cryo Q, Temperature control update 
                Reply  Sat Feb 10 18:17:56 2018, aaron, DailyProgress, Cryo Q, Temperature control update 
                   Reply  Mon Feb 12 10:41:20 2018, aaron, DailyProgress, Cryo Q, Temperature control update 
                      Reply  Mon Feb 12 15:50:45 2018, aaron, DailyProgress, Cryo Q, Temperature control update poltergeist2.pngfixed.pngspectrum.png
                         Reply  Tue Feb 13 10:17:20 2018, johannes, DailyProgress, Cryo Q, Re: Temperature control update 
                            Reply  Tue Feb 13 10:55:02 2018, aaron, DailyProgress, Cryo Q, Re: Temperature control update a_few_minutes_of_sanity.png
                               Reply  Thu Feb 15 10:20:21 2018, aaron, DailyProgress, Cryo Q, Re: Temperature control update IMG_3389.jpg
                                  Reply  Thu Feb 15 20:20:48 2018, aaron, DailyProgress, Cryo Q, Re: Temperature control update 
                                     Reply  Thu Feb 15 20:37:58 2018, aaron, DailyProgress, Cryo Q, Re: Temperature control update lownoiseish.pngRTD3.png
                                        Reply  Thu Feb 15 21:26:03 2018, aaron, DailyProgress, Cryo Q, Re: Temperature control update 56_PM.pngtheyreback.jpgfollower.jpg
                                           Reply  Fri Feb 16 11:06:45 2018, aaron, DailyProgress, Cryo Q, Re: Temperature control update 
Entry  Thu Feb 8 11:59:50 2018, Zach, Noise Hunting, SiFi, Single-cavity noise via inter-experiment beat SiFi-CryoCav_beat_2_7_18.pngSiFi-CryoCav_beat_zoom_2_7_18.png
    Reply  Thu Feb 15 12:11:42 2018, Zach, Noise Hunting, SiFi, More detailed look at displacement noise features (1 - 10 kHz) SiFi-CryoCav_beat_comparison_1k-10k_2_14_18.png
Entry  Tue Feb 13 11:41:07 2018, johannes, Noise Hunting, Transfer Functions, Photothermal TF recording photothermal_20180212.pdfphotothermal_20180212.tar.gzoutput.gif
    Reply  Tue Feb 13 22:34:49 2018, johannes, Noise Hunting, Transfer Functions, Photothermal TF recording photothermal_20180212.pdf
Entry  Tue Feb 13 15:25:35 2018, Zach, Noise Hunting, SiFi, Nonlinear noise investigation SiFi_nonlin_noise_2_9_18.png
Entry  Fri Feb 9 12:17:22 2018, Zach, Update, SiFi, Another mirror bonded; first bonded sample falls apart 
Entry  Thu Feb 8 21:05:48 2018, aaron, DailyProgress, Cryo Q, baking the schwarzschild 
Entry  Tue Jan 30 21:28:45 2018, johannes, Computing, Control System, New MEDM screen for CRYo cavities medm_main.pngzpk_slow.pngzpk_butter.pngslo_all.png
    Reply  Tue Feb 6 22:12:11 2018, johannes, Computing, Control System, EPICS channels for fan filter units 
Entry  Thu Feb 1 23:41:35 2018, Aaron, Misc, Vacuum, Varnish vacuum compatibility 
Entry  Tue Jan 30 21:09:34 2018, johannes, Things to Buy, Optics, 1550nm super steering mirrors have arrived IMG_20180129_173616244.jpgscan2.pdf
    Reply  Tue Jan 30 22:06:40 2018, johannes, Things to Buy, Optics, super mirrors installed in cryocav transmission path IMG_20180130_185800637.jpg
       Reply  Thu Feb 1 22:13:01 2018, johannes, Update, Optics, super mirrors installed in cryocav PDH path thorlabsPDH_20180201.pdf
Entry  Mon Jan 22 16:23:37 2018, aaron, DailyProgress, Cryo Q, Model of schwarzschild schwarzschild.PNG
    Reply  Mon Jan 22 21:19:14 2018, aaron, DailyProgress, Cryo Q, Model of schwarzschild 27156893_10215773450439703_132250377_n.jpg
       Reply  Wed Jan 31 22:30:15 2018, aaron, DailyProgress, Cryo Q, schwarzschild IMG_3314.JPGIMG_3319.JPGIMG_3320.JPGIMG_3317.JPG
Entry  Wed Jan 24 02:02:51 2018, Zach, Noise Hunting, SiFi, Getting to the bottom of sensing noise SiFi_beat_noise_1_23_18.pngSiFi_PD_noise_estimate_1_23_18.png
    Reply  Thu Jan 25 21:41:54 2018, Zach, Noise Hunting, SiFi, More sensing noise troubleshooting SiFi_beat_ERR_elevatednoise_1_25_18.png
       Reply  Wed Jan 31 16:14:38 2018, Zach, Noise Hunting, SiFi, Sensing noise not improved with higher-level mixers or iLIGO RFPDs SiFi_beat_noise_with_different_RFPDs_1_31_18.pngGold_PDs.jpg
Entry  Fri Jan 26 17:33:35 2018, aaron, DailyProgress, Cryo Q, Calibrating RTDs, question about framebuilder data 
    Reply  Mon Jan 29 13:16:54 2018, brittany, DailyProgress, Cryo Q, Calibrating RTDs, question about framebuilder data 
Entry  Mon Jan 22 21:19:46 2018, aaron, DailyProgress, Cryo Q, temperature control in Nalu 
    Reply  Tue Jan 23 18:06:53 2018, aaron, DailyProgress, Cryo Q, temperature control in Nalu 
       Reply  Mon Jan 29 13:12:13 2018, brittany, DailyProgress, Cryo Q, temperature control in Nalu 
Entry  Wed Jan 24 13:42:25 2018, rana, Summary, COMSOL, COMSOL model of disk with hole pattern HoleyDisk.png
Entry  Mon Jan 15 23:40:12 2018, Zach, Update, Si fab, Wafers prepped for etching "dummy" cantilevers, etc. 20180115_203207.jpg20180115_195114.jpg20180115_200853.jpg
    Reply  Wed Jan 17 14:57:32 2018, Zach, Update, Si fab, Dummy cantilevers etched, two brought over for mirror bonding 20180116_191007.jpg20180116_192257.jpg
       Reply  Thu Jan 18 11:31:00 2018, Zach, Update, SiFi, Mirror bonded to dummy cantilever 8x
          Reply  Sat Jan 20 16:01:50 2018, rana, Notes, SiFi, Mirror bonded to dummy cantilever 
Entry  Wed Jan 17 14:00:20 2018, Aaron, Cryostat, General, Vacuum gauge? B22B848D-8D35-43C5-95ED-3E7B6F8917D1.jpeg
    Reply  Wed Jan 17 14:53:23 2018, Zach, Cryostat, General, Vacuum gauge? 
Entry  Wed Oct 25 13:26:50 2017, Chris, HowTo, DAQ, restart revue: front ends, epics readout scripts 
    Reply  Tue Nov 21 23:55:00 2017, johannes, HowTo, DAQ, acromag and ziserver now initialized as systemd services 
       Reply  Fri Jan 12 11:03:33 2018, johannes, HowTo, DAQ, Setting up automatic scripts 
Entry  Thu Jan 4 23:02:26 2018, Zach, Update, SiFi, Clamp parts received---several problems 11x
    Reply  Thu Jan 11 18:08:26 2018, Zach, Update, SiFi, Clamp parts fixed tapping.jpgclamp_assys.jpgclamp_assy_with_jig.jpg
Entry  Fri Jan 5 11:43:30 2018, aaron, Computing, Lab Work, gaston rebooted 
    Reply  Mon Jan 8 10:44:14 2018, johannes, Computing, Lab Work, gaston rebooted 
Entry  Fri Dec 22 13:19:02 2017, Zach, Update, SiFi, LIGO servos installed and used to lock; other updates SiFi_servo_TF_comparison_12_21_17.pnglocked_with_LIGO_servos.jpgSiFi_beat_noise_LIGO_servos_12_21_17.png
Entry  Thu Dec 14 23:53:28 2017, johannes, Cryostat, Cryo, Fixed CTC100 readout, test cooldown started IMG_20171214_194834004.jpgIMG_20171214_202343775.jpgtemps.pngpress.png
    Reply  Fri Dec 15 11:41:54 2017, johannes, Cryostat, Cryo, LN2 topped off temps2.png
Entry  Thu Dec 14 10:20:38 2017, Brittany, Summary, Cryo Q, Operation Vacuum CleanCryo.jpgFeedThroughInside.jpgCrappyScrewHoles.jpgshineGoldBeauty.jpg
Entry  Tue Dec 5 17:41:59 2017, Brittany, DailyProgress, Cryo Q, vacuum + 2in fused silica disks bottomOfGauge.jpgOring_metalFilings.jpg
    Reply  Tue Dec 12 20:25:18 2017, rana, DailyProgress, Cryo Q, vacuum 
Entry  Mon Dec 11 22:04:45 2017, aaron, Update, Cryo Q, Temperature control this week 25344643_10215409240614685_1941606897_o.jpg25319926_10215409241374704_34538913_o.jpg
Entry  Sun Dec 10 22:32:43 2017, Zach, Update, SiFi, Clamp design (hoping to order Monday) 14x
Entry  Mon Dec 4 22:38:56 2017, johannes, Lab Infrastructure, General, lab noticably warmer 
Entry  Tue Nov 28 12:16:52 2017, brittany, DailyProgress, Cryo Q, Nuggets of vacuum knowledge from Bob Taylor 
    Reply  Tue Nov 28 18:16:41 2017, rana, DailyProgress, Cryo Q, Nuggets of vacuum knowledge from Bob Taylor 
Entry  Mon Nov 27 16:00:56 2017, brittany, DailyProgress, Cryo Q, crawling out of the vacuum sandbox 
    Reply  Tue Nov 28 17:27:08 2017, brittany, DailyProgress, Cryo Q, crawling out of the vacuum sandbox 
Entry  Mon Nov 27 14:29:01 2017, brittany, DailyProgress, Cryo Q, error budget + squeezed film damping GasDamping.pdf
Entry  Wed Nov 22 22:16:48 2017, Koji, Electronics, Cryo Q, Custom QPD unit working again after a power cable repair 
    Reply  Mon Nov 27 11:31:19 2017, brittany, Electronics, Cryo Q, Custom QPD unit working again after a power cable repair 
       Reply  Mon Nov 27 11:43:18 2017, Koji, Electronics, Cryo Q, Custom QPD unit working again after a power cable repair 
          Reply  Mon Nov 27 14:28:16 2017, brittany, Electronics, Cryo Q, Custom QPD unit working again after a power cable repair 
Entry  Mon Nov 13 14:26:02 2017, johannes, Lab Infrastructure, stuff happens, Replacing SR560 batteries 
    Reply  Fri Nov 24 19:06:08 2017, awade, Lab Infrastructure, stuff happens, Replacing SR560 batteries 
Entry  Wed Nov 22 00:32:07 2017, johannes, Lab Infrastructure, DAQ, Acromag A/D and D/A EPICS channels changed to physical units; D/A readback on IOC initialize 
Entry  Thu Nov 9 18:06:15 2017, Zach, Update, SiFi, Payload FEA modeling SiFi_current_noise_and_target_11_9_17.pngtestcav_payload_photo.pngScreen_Shot_2017-11-09_at_1.11.35_PM.pngScreen_Shot_2017-11-09_at_1.11.52_PM.pngSiFi_test_payload_mode_search_11_8_2017.png
    Reply  Fri Nov 17 13:01:00 2017, Zach, Update, SiFi, Payload FEA modeling and design update 6x
Entry  Thu Nov 16 16:00:52 2017, Zach, Lab Infrastructure, SiFi, Table unfloated, vacuum gauge cable removed for electrical work Fri 
Entry  Tue Nov 7 14:31:02 2017, johannes, Computing, stuff happens, Gaston rebooted 
    Reply  Wed Nov 8 23:32:38 2017, rana, Computing, General, Gaston rebooted 
       Reply  Mon Nov 13 18:31:35 2017, johannes, Computing, General, New workstation SpirouAttitude.pngGastonpied.gif
          Reply  Tue Nov 14 17:08:57 2017, johannes, Computing, General, spirou up to speed 
    Reply  Thu Nov 9 10:30:28 2017, brittany, Computing, stuff happens, Gaston rebooted 
    Reply  Mon Nov 13 18:13:25 2017, johannes, Computing, stuff happens, Gaston rebooted 
Entry  Mon Nov 13 11:37:22 2017, brittany, DailyProgress, Cryo Q, vacuum leak sleuthing Vacuum.pdf
    Reply  Mon Nov 13 14:55:16 2017, brittany, DailyProgress, Cryo Q, vacuum leak sleuthing 
       Reply  Tue Nov 14 09:38:15 2017, brittany, DailyProgress, Cryo Q, vacuum leak sleuthing 
Entry  Thu Nov 9 18:47:50 2017, rana, Notes, Cryo Q, Gas Damping: Effect on Q of Disks Screen_Shot_2017-11-09_at_5.43.09_PM.png
    Reply  Fri Nov 10 12:15:14 2017, johannes, Notes, Cryo Q, Dealing with leaks 
    Reply  Sun Nov 12 21:07:38 2017, Aaron, Notes, Cryo Q, Gas Damping: Effect on Q of Disks 
Entry  Thu Nov 9 12:16:27 2017, brittany, DailyProgress, Cryo Q, CryoQ through the years code Q_History.pdf
Entry  Thu Nov 9 11:42:55 2017, brittany, DailyProgress, Cryo Q, Measuring more glass ringdowns 
Entry  Tue Nov 7 08:26:59 2017, brittany, Notes, Cryo Q, Weekly gameplan  
Entry  Fri Oct 13 02:11:23 2017, johannes, Noise Hunting, Transfer Functions, Photothermal cavity response 6x
    Reply  Tue Oct 17 00:58:16 2017, johannes, Noise Hunting, Transfer Functions, disconnecting boards and remote servo controls modPDH_noise_20171011a.pdf
       Reply  Tue Oct 17 22:14:47 2017, johannes, Noise Hunting, Transfer Functions, what's in the box cavity_ringdown_20171017.tar.gzcavity_ringdowns_20171017.pdf
          Reply  Thu Oct 19 00:23:23 2017, johannes, Noise Hunting, Transfer Functions, tf board work vga_tf_20171017.pdfservo_mod_20171017.pdfservo_transfer_20171017.tar.gz
             Reply  Mon Oct 23 22:16:40 2017, johannes, Noise Hunting, Transfer Functions, modPDH changes checklist modPDH_noise_20171023.pdf
                Reply  Tue Oct 24 23:16:41 2017, johannes, Noise Hunting, Transfer Functions, preamp**2 
                   Reply  Sun Oct 29 21:48:41 2017, johannes, Noise Hunting, Transfer Functions, Loop Modelling 7x
                      Reply  Wed Nov 1 22:31:06 2017, johannes, Noise Hunting, Transfer Functions, Beat noise improved rp_beat_f_20171101.pdf
                         Reply  Tue Nov 7 00:31:48 2017, johannes, Summary, Lab Work, large modulations, missing light found 
Entry  Mon Nov 6 23:39:11 2017, Zach, Summary, SiFi, Beat noise evolution, 10/4/2016 - 11/5/2017 SiFi_beat_evolution_4Oct2017_5Nov2017.png
Entry  Wed Nov 1 16:24:05 2017, Zach, Noise Hunting, SiFi, Noise spookily higher by ~3x in broadband on Halloween SiFi_beat_noise_spooky_higher_10_31_17.png
    Reply  Wed Nov 1 22:33:24 2017, johannes, Noise Hunting, SiFi, table floating hardware 
       Reply  Sat Nov 4 16:22:24 2017, Zach, Update, SiFi, SiFi table is floating table_floating.jpgTMC_4-post_config.png
          Reply  Sun Nov 5 19:44:17 2017, Zach, Noise Hunting, SiFi, Noise (mostly) improved with table floating SiFi_beat_noise_floating_11_5_17.pngSiFi_scattered_light_100Hz_11_5_17.png
    Reply  Sat Nov 4 16:06:08 2017, Zach, Noise Hunting, SiFi, Low beat noise recovery SiFi_beat_noise_recovery_11_3_17.pngSMA_feedthrough_broken.jpgSiFi_beat_noise_recovery_hfzoom_11_3_17.png
Entry  Tue Oct 31 12:00:37 2017, johannes, Summary, Digital PLL, Second Red Pitaya configured 
    Reply  Wed Nov 1 12:50:45 2017, johannes, Computing, Digital PLL, RP GUI pimped gui_screenshot.png
       Reply  Wed Nov 1 15:40:31 2017, Zach, Computing, Digital PLL, RP GUI pimped 
Entry  Tue Oct 31 18:02:58 2017, rana, Photos, General, The Case of the Missing Camera 20171020_132501.jpg
Entry  Fri Oct 20 20:45:11 2017, aaron, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q 
    Reply  Tue Oct 24 11:00:08 2017, aaron, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q 
       Reply  Thu Oct 26 11:37:47 2017, aaron, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q 
          Reply  Thu Oct 26 12:58:26 2017, brittany, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q 
             Reply  Mon Oct 30 15:13:33 2017, brittany, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q 
                Reply  Mon Oct 30 16:46:35 2017, Koji, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q 
                Reply  Mon Oct 30 20:21:19 2017, aaron, DailyProgress, Cryo Q, measuring 3'' fused silica disk Q IMG_2903.jpgIMG_2904.jpgIMG_2905.jpgIMG_2902.jpg
Entry  Mon Oct 23 19:55:34 2017, Zach, Noise Hunting, SiFi, Noise floor improvement, some insight into limiting sources SiFi_beat_improved_10_20_17.png
    Reply  Fri Oct 27 03:18:00 2017, Zach, Noise Hunting, SiFi, Beat noise improved in vacuum pumping.jpgSiFi_beat_noise_10_26_17.png
Entry  Thu Oct 26 12:53:55 2017, brittany, HowTo, Cryo Q, the ranye ringdown method 
Entry  Wed Oct 25 16:36:16 2017, johannes, Computing, Cleanliness, Desktop clutter 
Entry  Tue Oct 24 17:45:39 2017, brittany, aaron, Notes, Cryo Q, weekly game plan 
Entry  Sat Oct 21 02:30:03 2017, Zach, Electronics, SiFi, Current state of making beat measurements with Red Pitaya RP_GUI_orig.pngRP_GUI_DAC_dropdown.png
    Reply  Tue Oct 24 00:45:39 2017, johannes, Electronics, SiFi, Red Pitaya Literacy pm_core_schematic.pdfopen_loop.pdfclosed_loop.pdfrp_model.py.tar.gz
Entry  Mon Oct 23 14:02:15 2017, rana, Cryostat, Cryo, Cryo-cooler overview 
Entry  Sun Oct 22 21:53:09 2017, rana, Computing, General, CryoWiki version upgraded 
Entry  Fri Oct 20 22:55:42 2017, aaron, DailyProgress, Cryo Q, temperature readout board noise measurements pt 1 
    Reply  Sun Oct 22 21:46:51 2017, rana, DailyProgress, Cryo Q, avoid the SR785 .78D format 
Entry  Fri Oct 20 16:58:12 2017, aaron, Things to Buy, Cryo Q, Glass wafers 
Entry  Thu Oct 19 05:05:03 2017, Zach, Update, SiFi, Windows reinstalled, new beat measurement windows_on.jpgSiFi_beat_10_18_17.pngSiFi_beat_10_18_17_zoom.png
    Reply  Thu Oct 19 09:24:19 2017, johannes, Update, SiFi, Windows reinstalled, new beat measurement 
    Reply  Fri Oct 20 16:37:41 2017, Zach, Update, SiFi, PDH sensing noise investigation TEK00000.TIFTEK00001.TIFSiFi_beat_PDH_sensing_noise_10_19_17.png
Entry  Tue Oct 17 15:57:35 2017, Zach, Update, Si fab, Cantilever update QPD_closer.jpgthin_cantilever_noisy_ringdown.jpg
    Reply  Tue Oct 17 21:29:50 2017, rana, Update, Si fab, Cantilever update 
       Reply  Wed Oct 18 18:10:40 2017, Zach, Update, Si fab, Cantilever update 
Entry  Thu Oct 12 01:53:01 2017, aaron, Notes, Cryo Q, Given the losses of our system, what is the best upper limit we can place on coating loss? 
    Reply  Tue Oct 17 22:59:12 2017, aaron, Notes, Cryo Q, Given the losses of our system, what is the best upper limit we can place on coating loss? FeldmanCousinsNotes.pdfLossConstraintNotes.pdfquickPhiConstraint.nbquickPhiConstraint.pdf
Entry  Tue Oct 17 14:56:59 2017, brittany, DailyProgress, Cryo Q, moved paper draft to overleaf 
Entry  Tue Oct 17 11:21:58 2017, brittany, DailyProgress, Cryo Q, fused silica sample from gabriele 
Entry  Mon Oct 16 14:46:41 2017, aaron, brittany, Notes, Cryo Q, weekly game plan 
    Reply  Mon Oct 16 17:58:55 2017, brittany, Notes, Cryo Q, weekly game plan 
Entry  Thu Oct 12 18:01:28 2017, aaron, Update, Cryo Q, ordered some RTD mounts RTD_mount.PNG
Entry  Thu Oct 12 02:02:47 2017, aaron, Update, Cryo Q, Eigenfrequency vs Temperature modeling 10x
Entry  Thu Oct 12 01:27:04 2017, johannes, Lab Infrastructure, General, power supply IMG_20171002_104840728.jpgIMG_20171011_094742691.jpgIMG_20171011_094631998.jpgIMG_20171011_094617555.jpgIMG_20171011_094845992.jpg
Entry  Wed Oct 4 01:01:45 2017, johannes, Notes, PDH, PDH 'debugging' 
    Reply  Fri Oct 6 01:05:48 2017, johannes, Notes, PDH, PDH 'debugging' 7x
Entry  Tue Oct 3 23:53:51 2017, Zach, Update, SiFi, Improvements to optical setup 6x
    Reply  Thu Oct 5 12:42:34 2017, Zach, Update, SiFi, First beat noise measurement! SiFi_ctrl_and_beat_noise_m_10_4_17.pngTRANS_setup_traced.jpgbeat_FD.jpgbeat_TD.jpgbeat_readout.png
Entry  Wed Oct 4 09:20:58 2017, johannes, Notes, Digital PLL, Red Pitaya Phasemeter Core pm_core_schematic.pdfrp_vs_marconi_p.pdf
Entry  Fri Jun 30 09:27:30 2017, Luis, Electronics, General, PDH Servo-Electronics Testing LPF_GAIN.pngWTMON_P.pnggain_Noise.pngPS-921_Voltage_Control_chart.PNGVoltage_Control_chart_PDH_servo.PNG
    Reply  Mon Jul 10 09:20:57 2017, johannes, Electronics, General, PDH Servo-Electronics Testing 
       Reply  Fri Aug 4 00:24:05 2017, johannes, Electronics, General, PDH Servo-Electronics Testing servos_20170803.pdftf_board.pdf
          Reply  Mon Aug 28 02:12:08 2017, johannes, Electronics, General, PDH Doctor Games 11x
             Reply  Tue Aug 29 10:00:13 2017, johannes, Electronics, General, nuPDH proposed changes 
             Reply  Sun Sep 24 19:24:48 2017, johannes, Electronics, General, nuPDH sensing noise west_error_offsetpll_sweep2.pngeast_error_offsetpll_sweep2.pngwest_error_slope.pdfeast_error_slope.pdf
             Reply  Fri Sep 29 12:13:56 2017, johannes, Electronics, General, Updated PDH schematic SCH_PCB_BOM_PDH_TF_v2_modified.pdf
                Reply  Fri Sep 29 16:59:11 2017, rana, Electronics, General, Updated PDH schematic 
                   Reply  Sat Sep 30 17:57:04 2017, johannes, Electronics, General, Updated PDH schematic 
                      Reply  Sun Oct 1 15:02:42 2017, rana, Electronics, General, Updated PDH schematic 
                         Reply  Mon Oct 2 01:10:29 2017, johannes, Electronics, General, Updated PDH schematic tf_comp.pdfinputnoise_comp.pdfCD_HiFmod1.pngnuPDH.zip
Entry  Fri Sep 29 01:02:51 2017, johannes, Noise Hunting, Plots, VGA noise measurement vga_west_noise_20170928.pdfvga_east_noise_20170928.pdfAD8336outputreferrednoise.png
Entry  Thu Sep 28 23:04:18 2017, Chris, HowTo, DAQ, Creating an excitation with an arbitrary spectrum 
Entry  Tue Sep 26 00:11:13 2017, aaron, Update, Cryo Q, temperature measurements on wafers 7x
    Reply  Tue Sep 26 17:49:15 2017, aaron, Update, Cryo Q, temperature measurements on wafers 
       Reply  Tue Sep 26 22:52:53 2017, aaron, Update, Cryo Q, temperature measurements on wafers 
          Reply  Wed Sep 27 12:39:58 2017, aaron, Update, Cryo Q, temperature measurements on wafers cooldownscreenshot.pngcooldown_calculation.nb.zip
Entry  Tue Sep 26 16:27:37 2017, aaron, Computing, Cryo Q, DAQ error? User error? 
    Reply  Tue Sep 26 16:54:38 2017, aaron, Computing, Cryo Q, DAQ error? User error? 
       Reply  Tue Sep 26 22:38:12 2017, johannes, Computing, Cryo Q, DAQ error? User error? 
Entry  Mon Sep 25 12:25:34 2017, aaron, Misc, Simulation, Silicon wafer orientation? 
    Reply  Tue Sep 26 14:25:57 2017, Zach, Misc, Simulation, Silicon wafer orientation? 
Entry  Thu Aug 17 13:02:36 2017, johannes, Update, General, PDH, temp. control & beat signal trans_setup.pngAG4395A_17-08-2017_110136.pdf
    Reply  Thu Aug 17 19:10:18 2017, johannes, Update, General, Faraday isolators cav_input_mode_calc.zipFrontMirrorBeamExpansion.pngIMG_20170817_164600206.jpgIMG_20170817_164452244.jpg
       Reply  Fri Aug 18 16:16:20 2017, rana, Update, General, Faraday isolators Screen_Shot_2017-08-18_at_4.12.53_PM.png
          Reply  Sat Aug 19 09:22:49 2017, johannes, Update, General, First success identifying scatterers with PZT buzzer stick IMG_20170818_182151379.jpgtrans_beat.pdf
             Reply  Tue Sep 5 13:43:18 2017, johannes, Update, General, the latest buzz 6x
                Reply  Thu Sep 7 22:17:50 2017, johannes, Update, General, on swapping optics 
                   Reply  Sun Sep 24 20:05:21 2017, johannes, Update, General, on swapping optics TPD_contrast.pngcomp_beat.pdf
Entry  Fri Sep 22 16:46:32 2017, aaron, DailyProgress, Cryo Q, RTDs attached to disks 21981673_10214724553057924_1677073240_o.jpg21981884_10214724553017923_1938351002_o.jpg21931620_10214724552977922_1071220132_o.jpg
Entry  Fri Sep 22 10:07:56 2017, aaron, HowTo, Cryo, Cryo Thermometry Compilation 
    Reply  Fri Sep 22 13:23:12 2017, rana, HowTo, Cryo, Cryo Thermometry Compilation 
       Reply  Fri Sep 22 14:27:27 2017, aaron, HowTo, Cryo, Cryo Thermometry Compilation Screen_Shot_2017-09-22_at_2.21.07_PM.png21931045_10214723746717766_1022132499_o.jpg
Entry  Tue Sep 19 11:46:34 2017, aaron, Notes, Cryo Q, ringdowns 
    Reply  Wed Sep 20 22:46:37 2017, aaron, Notes, Cryo Q, ringdowns 21908767_10214709126352266_2115094904_o.jpg
Entry  Wed Sep 20 22:36:28 2017, aaron, Misc, Cryo Q, Cantilever measurements paper, some thoughts 
Entry  Fri Sep 1 17:54:45 2017, br!tt@ny, DailyProgress, Cryo Q, DAQ attack RingFilter_170901.png
    Reply  Wed Sep 6 19:52:42 2017, rana, DailyProgress, Cryo Q, DAQ attack 
       Reply  Thu Sep 7 11:18:17 2017, brittany, DailyProgress, Cryo Q, DAQ attack 
          Reply  Tue Sep 19 11:47:27 2017, rana, DailyProgress, Cryo Q, FEA 
             Reply  Wed Sep 20 22:20:24 2017, aaron, DailyProgress, Cryo Q, FEA 
Entry  Wed Sep 20 15:28:33 2017, brittany, Computing, General, installed vnc on gaston 
Entry  Wed Sep 20 15:23:58 2017, Zach, Update, SiFi - ringdown, Recent progress bake_setup.jpgTEK00000.TIFTEK00002.TIFAPD_designs_9_13_17.pdf
Entry  Fri Sep 15 21:09:41 2017, Zach, Lab Infrastructure, Cleanliness, Cryo lab ready for plumbing work thats_a_wrap.jpg
Entry  Wed Sep 13 11:44:29 2017, brittany, DailyProgress, Cryo Q, towards simultaneous multiple Q measurements 
Entry  Wed Sep 6 19:07:31 2017, Zach, Update, SiFi - ringdown, Q measurement setup built on SiFi table, first ringdown oplev_setup.jpg115Hz_modering.png115Hz_ringdown.png
    Reply  Thu Sep 7 14:03:24 2017, Zach, Update, SiFi - ringdown, First new cantilever room-temperature Q ~ 10,000 (low) 
       Reply  Fri Sep 8 14:48:41 2017, Zach, Update, SiFi - ringdown, Hole & no-hole cantilever room-temperature Q >= 10^5 TEK00002.TIFTEK00003.TIFholed_cantilever_clamped.jpgTEK00007.TIFTEK00009.TIF
          Reply  Tue Sep 12 14:28:42 2017, Zach, Update, SiFi - ringdown, Holed cantilever Q worse at low temperature (~30k) cantilever_in_cryostat.jpgcyrostat_oplev.jpgTEK00010.TIF
Entry  Wed Sep 6 15:07:37 2017, brittany, DailyProgress, Cryo Q, temp loop 
Entry  Tue Sep 5 03:41:49 2017, Zach, Update, Si fab, KNI progress 8/29-9/4 holeless_cantilever1.jpgholeless_cantilever2.jpgholed_cantilever1.jpgholed_cantilever2.jpg
Entry  Wed Aug 30 17:37:03 2017, brittany, DailyProgress, Cryo Q, CryoQ comeback tour 
    Reply  Wed Aug 30 22:47:59 2017, Aaron, DailyProgress, Cryo Q, CryoQ comeback tour 
       Reply  Thu Aug 31 13:58:51 2017, rana, DailyProgress, Cryo Q, CryoQ comeback tour 
          Reply  Thu Aug 31 16:40:35 2017, aaron, DailyProgress, Cryo Q, CryoQ comeback tour Zener_thermoelastic_envelope.nb
             Reply  Fri Sep 1 13:39:16 2017, brittany, DailyProgress, Cryo Q, CryoQ comeback tour 
Entry  Fri Sep 1 00:40:26 2017, aaron, Laser, Cryo Q, Optics upgrade 
Entry  Thu Aug 31 19:20:07 2017, rana, Notes, General, Voyager pre-prototype GMgraph.png
Entry  Tue Aug 29 23:43:22 2017, Zach, Update, Si fab, New cantilevers ready soon (for ringdowns) New_cantilevers1.jpgNew_cantilevers2.jpg
Entry  Tue Aug 29 21:02:03 2017, johannes, Lab Infrastructure, Purchases, New old power supplies 
Entry  Wed Aug 9 14:28:48 2017, Mariia, Notes, electrostatic suspension, Comsol simulation: new model, air gap st_energy.PNG499.9.PNG500(1).PNG500(2).PNG
    Reply  Wed Aug 16 19:26:39 2017, rana, Notes, electrostatic suspension, Comsol simulation: new model, air gap 
       Reply  Wed Aug 23 16:00:05 2017, Zach, Notes, electrostatic suspension, Comsol simulation: new model, air gap 
          Reply  Wed Aug 23 19:31:20 2017, Zach, Notes, electrostatic suspension, 2 "Coating Q" ESDs found ESD_back.jpgESD_front.jpg
Entry  Sun Jul 9 21:06:50 2017, johannes, Cryostat, Vacuum, Vent summary IMG_20170625_160009924.jpgIMG_20170625_160021500.jpg
    Reply  Mon Jul 17 01:40:06 2017, johannes, Cryostat, Vacuum, Vent progress shield_indium_seal.jpgshield_viewport.jpgshield_viewports.jpgplate_seal.jpgplate_indium_seal_joint.jpg
       Reply  Mon Jul 24 18:16:29 2017, johannes, Cryostat, Vacuum, Vent progress inner_cryostat_pumpdown.png
          Reply  Thu Aug 3 23:34:56 2017, johannes, Cryostat, Vacuum, Vent complete, optics realigned pumpdown.png
             Reply  Wed Aug 23 10:20:55 2017, johannes, Cryostat, Vacuum, Pumpdown progress; LN2 transfer line cryopressure_14daytrend.pngIMG_20170822_155337439.jpgln2fillline.pdf
Entry  Tue Aug 22 00:17:25 2017, Mariia, Notes, electrostatic suspension, set-up attach-636386433546334401.jpgattach-636389576488391903.jpg
Entry  Thu Aug 17 19:23:53 2017, Aaron, Lab Infrastructure, stuff happens, IFR 2023A sig generator diagnosis 
    Reply  Thu Aug 17 22:24:13 2017, Koji, Lab Infrastructure, stuff happens, IFR 2023A sig generator diagnosis 
       Reply  Mon Aug 21 15:59:57 2017, Zach, Lab Infrastructure, stuff happens, IFR 2023A sig generator diagnosis 
Entry  Sun Aug 20 23:58:13 2017, adele, Summary, thermal conductivity, Thermal conductivity of optically contacted samples ThermalStrapSetup.JPGdirtycopper.jpgcleancopper.jpg
Entry  Thu Aug 17 14:34:51 2017, Mariia, Notes, electrostatic suspension, New pattern for PCB 2.PNG3.PNG
    Reply  Sat Aug 19 20:37:49 2017, rana, Summary, electrostatic suspension, On the breakdown of air PaschenCurve.pdf
Entry  Wed Aug 16 15:25:34 2017, Aaron, Laser, Cryo Q, Flickering HeNe 20170816_144825.jpg
    Reply  Thu Aug 17 17:58:48 2017, Aaron, Laser, Cryo Q, Flickering HeNe 
Entry  Thu Aug 17 17:56:41 2017, Aaron, Electronics, stuff happens, Aaron 
Entry  Thu Aug 17 14:23:15 2017, Adele, Update, Optical Contacting, High temp (325C) and 3kg weight curing process high3kg_fulldata.pnghigh3kg.png
Entry  Wed Aug 16 17:08:49 2017, Jordan Kemp, Cryostat, Cryo Q, Setting up temperature dependence of eigenfrequencies setup.pnglasers.png
Entry  Wed Aug 16 17:02:41 2017, Jordan Kemp, Summary, Temperature Sensing, Copper straps 20883587_10213611686754053_188233651_o.pngok.png
Entry  Tue Aug 15 14:05:49 2017, Aaron, Update, Cryo Q, Week of 7 Aug activities 
Entry  Tue Aug 15 11:34:57 2017, Zach, Laser, SiFi, Red Pitaya free-running frontal beat measurement SiFi_laserfreqn_redpitaya_vs_PMC_8_10_17.png
Entry  Sun Aug 13 20:39:25 2017, Adele , Update, Temperature Sensing, Polish copper / silicon interface polish_heat.png
Entry  Fri Aug 11 01:56:09 2017, Jordan Kemp, Cryostat, Cryo Q, Temperature dependence of eigenfrequencies setup 20795039_10213573849848154_1680778029_o.jpg20773706_10213573847608098_933109525_o.jpg
Entry  Thu Aug 10 12:29:17 2017, Adele, Update, Optical Contacting, Optical contact experiment update 
Entry  Thu Aug 10 12:19:55 2017, Adele, Update, Cryo, Mirror finished copper / silicon interface mirror_heat.png
Entry  Wed Aug 9 23:50:04 2017, Zach, Update, SiFi, Test cavities realigned and locked with LB boxes, TRANS setup rebuilding LB_boxes.jpgTRANS_CAM.jpgTRANS_layout_traced.jpg
Entry  Wed Aug 9 17:05:00 2017, Jordan Kemp, Cryostat, Cryo Q, I built this 20747478_10213562549525653_1147219837_o.jpgScreen_Shot_2017-08-09_at_5.02.24_PM.png
Entry  Tue Aug 8 12:28:19 2017, Adele, Update, Cryo, Brush copper / silicon interface conductivity steadystate.pngsemilogy_k_aluminum.pngbrush_heat.png
    Reply  Tue Aug 8 19:57:48 2017, rana, Update, Cryo, comments 
Entry  Tue Aug 8 10:42:46 2017, Jordan Kemp, Computing, Coatings, Error propagation for coatings model OscillatorParameterErrorProp.nbScreen_Shot_2017-08-08_at_10.37.01_AM.png
Entry  Tue Aug 8 10:25:25 2017, Jordan Kemp, Cryostat, Temperature Sensing, Calibrated RTD Screen_Shot_2017-08-07_at_6.35.50_PM.png
Entry  Mon Aug 7 21:36:24 2017, Zach, Update, SiFi, Test PMC setup rebuilt, laser frequency noise test_PMC_traced.jpgSiFi_laser_freqn_PMC_8_5_17.png
Entry  Fri Aug 4 21:15:56 2017, Mariia, DailyProgress, electrostatic suspension, Photosensors 8x
Entry  Fri Aug 4 17:49:12 2017, Jordan Kemp, Electronics, Cryo Q, RTD Op Amp Circuit 20641595_10213517664203548_605183466_o.jpgDiagrams2.pagesRTD.jpgRTD.jpg
Entry  Thu Aug 3 23:49:19 2017, Zach, Electronics, stuff happens, Marconi busted? Marconi_broken_480.mov
    Reply  Fri Aug 4 00:28:22 2017, johannes, Electronics, stuff happens, Marconi busted? 
Entry  Fri Aug 4 00:01:57 2017, Mariia, Notes, electrostatic suspension, Vacuum and sensors vacuum.pnghigh-voltage_input_port.pngphotosensors.png
Entry  Thu Aug 3 23:44:39 2017, Zach, Update, SiFi, Frontal beat setup re-aligned, beat recovered Frontal_beat_layout_traced.jpgFrontal_beat_50MHz.jpg
Entry  Wed Aug 2 03:35:18 2017, Zach, Electronics, SiFi, Current driver range increased to 200 mA SiFi_current_driver2_coarse_response_8_1_17.pngSiFi_current_driver2_fine_response_8_1_17.pngR31.jpg
    Reply  Wed Aug 2 08:31:58 2017, Johannes, Electronics, SiFi, Current driver range increased to 200 mA 
       Reply  Wed Aug 2 17:23:48 2017, Zach, Electronics, SiFi, Current driver range increased to 200 mA SN104978_PvsI.pdf
    Reply  Thu Aug 3 18:06:05 2017, Zach, Update, SiFi, More system characterization measurements (laser drivers, heads) SiFi_laser_PvsI_8_2_17.png
Entry  Thu Aug 3 14:02:50 2017, Adele, Update, Cryo, Copper - Silicon interface IMG_4622.JPG
Entry  Thu Aug 3 09:29:43 2017, brittany, DailyProgress, Cryo Q, Air Q progress AirQ.jpg
Entry  Thu Aug 3 09:26:25 2017, brittany, Update, electrostatic suspension, Levitation in the OMC lab 
Entry  Mon Jul 31 23:32:58 2017, Mariia, DailyProgress, electrostatic suspension, Equipotential surfaces electrode.PNGhalf-way.PNGsilicon.PNGsilicon.PNGsilicon.PNG
Entry  Fri Jul 28 21:12:17 2017, Mariia, Notes, electrostatic suspension, Electric field norm att4.PNGatt5.PNG
Entry  Fri Jul 28 20:38:12 2017, Mariia, Computing, electrostatic suspension, Connecting Windows with Linux 
Entry  Fri Jul 28 16:38:08 2017, Jordan Kemp, Cryostat, Temperature Sensing, Trying to account for errors 20465170_10213454495464369_764310186_o.png
Entry  Fri Jul 28 13:14:03 2017, Zach, Electronics, electrostatic suspension, "Safe" HVDC drive cryostat_HV_port.jpgmagic_box.jpgmagic_box_interior.jpgsorensen_HV.jpgmagic_box_inputs.jpg
Entry  Thu Jul 27 16:59:27 2017, Jordan Kemp, Cryostat, Temperature Sensing, Took Copper Strap data ss.pngdata.pngScreen_Shot_2017-07-27_at_4.50.27_PM.pngdata1.pngdata.png
Entry  Thu Jul 27 13:29:53 2017, adele, Update, Temperature Sensing, Assembly and pump down blueRTD.pngyellowRTD.pngIMG_4604.JPGno_sample.png
Entry  Thu Jul 27 12:27:56 2017, brittany, DailyProgress, Cryo Q, Prepping for in air Q measurements WindowFlakes.jpgLinearActuator.jpgActuationTesting.jpg
Entry  Wed Jul 26 03:10:36 2017, Jordan Kemp, Cryostat, Temperature Sensing, Took Copper Strap data 20447055_10213427566431160_813455861_o.jpgScreen_Shot_2017-07-26_at_2.54.51_AM.pngScreen_Shot_2017-07-26_at_3.02.32_AM.pngScreen_Shot_2017-07-26_at_3.02.43_AM.png
    Reply  Wed Jul 26 09:17:55 2017, brittany, Cryostat, Temperature Sensing, Took Copper Strap data 
Entry  Tue Jul 25 16:35:57 2017, brittany, DailyProgress, Cryo Q, moving pele 
Entry  Tue Jul 25 15:00:31 2017, johannes, Lab Infrastructure, General, Power supplies nearing current limitation 
Entry  Tue Jul 25 13:06:08 2017, adele, Update, Optical Contacting, Silicon optical contacting CleanWafer.jpgOpticalContact.jpgThreeStack.jpg
Entry  Tue Jul 25 10:50:35 2017, brittany, DailyProgress, Vacuum, setting up Nalu 
Entry  Fri Jul 21 16:17:14 2017, Vineeth, Notes, Digital PLL, Laser transfer function measurement drawing.svg
    Reply  Sun Jul 23 16:10:48 2017, rana, Notes, Digital PLL, Laser transfer function measurement 
       Reply  Mon Jul 24 11:08:44 2017, johannes, Notes, Digital PLL, Laser transfer function measurement current_driver_input.png
Entry  Sun Jul 23 17:40:04 2017, Jordan Kemp, Cryostat, Temperature Sensing, Completed setup - Interfaced with DAQ setup_2.jpgScreen_Shot_2017-07-23_at_4.29.34_PM.png
    Reply  Mon Jul 24 10:40:00 2017, johannes, Cryostat, Temperature Sensing, Completed setup - Interfaced with DAQ 
Entry  Fri Jul 21 18:11:01 2017, Mariia, Summary, electrostatic suspension, Model in Comsol model.PNG
Entry  Thu Jul 20 17:56:28 2017, Mariia, Summary, electrostatic suspension, Electrode pattern 1_3.PNG1_1.PNG4.PNG
Entry  Thu Jul 20 13:21:54 2017, brittany, Update, material properties, Progess on Young's modulus measurements for NASA Goddard black samples NanoIndentation_BlackCoating.png
Entry  Thu Jul 20 10:34:52 2017, Jordan Kemp, Cryostat, Temperature Sensing, Diode Calibration, Cryostat setup 20182195_10213333320115061_1727958169_o_2.jpgScreen_Shot_2017-07-20_at_10.20.31_AM.png.png
Entry  Thu Jul 13 13:36:21 2017, Vineeth, Notes, Digital PLL, Laser transfer function measurement  PTF.pdfLTF.pdfCTF.pdfdrawing.svg
    Reply  Thu Jul 13 21:52:58 2017, rana, Notes, Digital PLL, Laser transfer function measurement  
       Reply  Fri Jul 14 13:16:35 2017, vineeth, Notes, Digital PLL, Laser transfer function measurement  
    Reply  Tue Jul 18 20:04:27 2017, rana, Notes, Digital PLL, Laser transfer function measurement  
Entry  Tue Jul 11 19:59:54 2017, Vineeth, Notes, DAQ, Red Pitaya ADC-DAC Transfer function ATF.pdf
    Reply  Thu Jul 13 12:46:38 2017, Vineeth, Notes, DAQ, Red Pitaya ADC-DAC Transfer function 
Entry  Wed Jul 12 12:11:56 2017, johannes, Laser, Laser, East/West settings for resonance+beat 
Entry  Tue Jul 11 17:23:30 2017, Vineeth, Notes, Digital PLL, PLL output calibration 
Entry  Tue Jul 11 16:19:28 2017, Vineeth, Notes, Digital PLL, PLL output format  
Entry  Sat Mar 25 22:43:46 2017, johannes, Noise Hunting, Cavity, CryoCoatingCavs Ringdowns, Error Signals & Co 6x
    Reply  Tue Apr 4 08:18:31 2017, johannes, Noise Hunting, Noise Budget, LB1005 internal noise LB1005_GainSettings_comp.pdfLB1005_East_noise.pdfLB1005_West_noise.pdfbeat_sense_noise.pdf
       Reply  Wed Apr 5 23:27:12 2017, johannes, Noise Hunting, Noise Budget, Sensing noise error_noise_west_20170405b.pdferror_noise_east_20170405b.pdferror_noises_west_20170405b.pdferror_noises_east_20170405b.pdf
          Reply  Fri Apr 7 01:44:22 2017, johannes, Noise Hunting, Noise Budget, Sensing noise 6x
             Reply  Fri Apr 7 02:09:31 2017, Koji, Noise Hunting, Noise Budget, Sensing noise 
          Reply  Sat Apr 8 12:53:33 2017, johannes, Notes, PDH, RIO planex amplitude response laser_response_20170407.pdf
             Reply  Mon Apr 17 16:27:54 2017, johannes, Notes, PDH, RIO planex amplitude response TFAG4395A_17-04-2017_152730.pdfcurrent_driver_mod.pdf
                Reply  Wed Apr 19 12:48:06 2017, johannes, Notes, Laser, Current driver oscillations current_driver_mod.pdfAG4395A_18-04-2017_181713.pdf
                   Reply  Fri Apr 28 11:37:41 2017, johannes, Notes, Laser, RFPD transfer functions RFPD_response_20170413.pdf
                      Reply  Thu May 4 19:13:04 2017, johannes, Notes, Laser, RIO planex frequency response laser_frequency_response.pdfpll_scheme.pdflaser_response_20170504.pdf
                         Reply  Tue May 9 16:18:02 2017, rana, Notes, Laser, LB1005 Transfer Function 
                            Reply  Thu Jun 15 13:58:17 2017, johannes, Notes, Laser, Laser frequency response west_response_20170614.pdf
                      Reply  Wed Jun 14 18:37:15 2017, johannes, Notes, Laser, RFPD circuitry RFPD_notches.jpgRFPD_WEST.jpgRFPD_EAST.jpg
                         Reply  Thu Jun 15 09:24:06 2017, Chris, Notes, Laser, RFPD circuitry 
                            Reply  Thu Jun 15 11:39:03 2017, Koji, Notes, Laser, RFPD circuitry 
                         Reply  Sat Jun 17 02:56:26 2017, johannes, Notes, Laser, RFPD circuitry IMG_20170616_143847305.jpg
                            Reply  Sun Jul 9 21:56:07 2017, johannes, Notes, Laser, RFPD circuitry resPD_20170622.pdf
Entry  Mon Mar 27 15:14:37 2017, johannes, Lab Infrastructure, Drawings, Acoustic shield for CryoCoatingCavs CryoAudioBlock_walls2.PDFCryoAudioBlock_walls_drawing.PDF
    Reply  Sat Jun 17 03:06:21 2017, johannes, Lab Infrastructure, Drawings, Acoustic shield for CryoCoatingCavs IMG_20170502_194421411.jpgIMG_20170615_153904904.jpg
       Reply  Sun Jul 9 21:28:17 2017, johannes, Lab Infrastructure, Drawings, Acoustic shield for CryoCoatingCavs IMG_20170707_175533248.jpgIMG_20170707_175552324.jpg
Entry  Fri Jul 7 18:03:27 2017, Jordan Kemp, Electronics, Temperature Sensing, Calibrated some diodes Plot.jpg
Entry  Fri Jul 7 17:02:08 2017, adele, Update, Temperature Sensing, 100 ohm RTD cooldown TS_test_run_cooling.png
Entry  Thu Jul 6 17:29:47 2017, brittany, DailyProgress, Cryo Q, Periscope mirror replacement 
Entry  Thu Jul 6 13:04:18 2017, Vineeth, Notes, DAQ, Closed loop measurements Closed_loop.pdf
Entry  Thu Apr 20 12:06:04 2017, johannes, Lab Infrastructure, DAQ, Slow DAQ chassis Acromag_2U.pdf
    Reply  Wed Apr 26 17:10:54 2017, brittany, Lab Infrastructure, DAQ, Slow DAQ chassis 
       Reply  Thu Jul 6 09:44:21 2017, johannes, Lab Infrastructure, DAQ, CryoLab Multifunction I/O chassis 
Entry  Wed Jul 5 08:41:54 2017, Jordan Kemp, Cryostat, Temperature Sensing, Set up diode calibration 19807582_10213199864218747_443888247_o.jpg
Entry  Fri Jun 30 17:29:24 2017, Adele, Update, Cryo, cryostat assembly  Assembly1.JPG
Entry  Thu Jun 29 18:13:06 2017, Adele, Update, , Thermal radiation calculation 
Entry  Thu Jun 29 17:07:37 2017, Adele, Summary, Cryo, Cryostat preparation RawTSplate.JPGSandedTSplate.JPGGluedTS1.JPG
Entry  Fri Jun 23 16:38:12 2017, Jordan Kemp and Mariia Matiushechkina, DailyProgress, Laser, Optical lever signal and Explored crystat 
Entry  Thu Jun 22 12:47:42 2017, Luis, Electronics, General, PDH Servo -Electronics Testing servo_out_N.pngservo_out_P.pngGain_vs_Vgain_PDH_AD8336.jpgTFINT1.pngINT1off.png
Entry  Mon Jun 19 20:03:41 2017, Vineeth, Notes, DAQ, ADPLL testing IMG_20170616_171953.jpgIMG_20170616_172026.jpg
Entry  Mon Jun 19 19:39:13 2017, Vineeth, Notes, DAQ, ADPLL simulation Screenshot_from_2017-06-16_17-26-42.pngScreenshot_from_2017-06-19_19-35-10.png
Entry  Wed Jun 14 18:45:17 2017, brittany, Update, COMSOL, CryoQ COMSOL update 
Entry  Wed Jun 14 18:33:20 2017, brittany, Update, Cryo Q, Shiny new GeNS Update GeNS_1.jpgGeNS_2.jpgTopDown_GeNS.jpg
Entry  Tue Jun 13 12:48:33 2017, Vineeth, Notes, DAQ, ADC Effective resolution test g_fit_adc_ch1_gr.pngg_fit_adc_ch2_gr.png
Entry  Tue Jun 13 10:20:39 2017, Luis , Electronics, General, PDH Servo - Electronics Testing pdh_servo_front_panel.pdfpdh_servo_boards.pdfphase_lost_at_91KHz.pdf
Entry  Mon Jun 12 12:14:45 2017, johannes, Things to Buy, General, Super Steering-Mirrors for 1550 nm 
Entry  Wed Jun 7 11:34:11 2017, Vineeth, Notes, DAQ, NCO simulation direct.pngwgng.png
Entry  Thu Jun 1 19:10:55 2017, Vineeth, Notes, DAQ, Red Pitaya conversion factor test.jpg
Entry  Mon Mar 20 12:30:50 2017, johannes, Things to Buy, Cryo, Heat Switch wiki page 
    Reply  Tue Mar 21 22:04:17 2017, johannes, Things to Buy, Cryo, Heat Switch wiki page sagging_preload_mount.pngblade_squeeze.pngheat_switch_initial.svg.pngpassive_switch_1.svg.pngthor_cryo_copper_braid.jpg
       Reply  Wed May 31 23:06:36 2017, johannes, Things to Buy, Cryo, Heat Switch drawing ideas StandoffAssembly.PDFThermalPlateAssembly.PDF
Entry  Tue May 30 19:24:19 2017, Vineeth, Notes, DAQ, ADC input noise spectrum in_AG4395A.pdf
    Reply  Tue May 30 22:44:42 2017, johannes, Notes, DAQ, ADC input noise spectrum 
    Reply  Wed May 31 16:32:20 2017, Vineeth, Notes, DAQ, ADC input noise spectrum 
Entry  Tue May 30 23:11:11 2017, johannes, Noise Hunting, Noise Budget, jupyter noise budget github upload intrinsic_noise.pdfsensing_noise.pdfnoise_budget.pdf
Entry  Tue May 30 18:10:59 2017, Vineeth, Notes, DAQ, DAC output noise spectrum ch1_out_SR785.pdfch2_out_SR785.pdf
Entry  Mon Mar 6 23:49:50 2017, Aaron, DailyProgress, Cryo Q, Measurements with ESD 
    Reply  Thu Mar 9 10:03:21 2017, johannes, Computing, DAQ, Networking with scopes 
       Reply  Thu Mar 9 10:30:10 2017, rana, Computing, DAQ, Networking with scopes 
          Reply  Fri Mar 10 20:09:52 2017, johannes, Computing, DAQ, Networking with scopes 
             Reply  Thu May 25 17:25:21 2017, johannes, Computing, DAQ, netgpib 
Entry  Wed May 10 17:06:54 2017, Aaron, Photos, material properties, SEM Pictures of Goddard Coatings 10x
    Reply  Thu May 11 17:55:53 2017, rana, Photos, material properties, SEM Pictures of Goddard Coatings ColorTubes.png
Entry  Wed Apr 26 17:08:55 2017, brittany, DailyProgress, Cryo Q, DAQ ESD drive testing 18.png45.png
    Reply  Fri Apr 28 15:19:17 2017, brittany, DailyProgress, Cryo Q, DAQ ESD drive testing 
Entry  Thu Mar 23 23:59:11 2017, Aaron, Things to Buy, Cryo Q, GeNS Drawings going out! 9x
    Reply  Wed Mar 29 15:13:15 2017, Aaron, Things to Buy, Cryo Q, GeNS Drawings going out! 
       Reply  Thu Mar 30 22:54:08 2017, Aaron, Things to Buy, Cryo Q, GeNS Drawings going out! 
    Reply  Tue Apr 25 19:51:18 2017, rana, Things to Buy, Cryo Q, GeNS Drawings going out! 
Entry  Mon Apr 24 12:27:14 2017, rana, Summary, Sensors, Temperature Sensors Screen_Shot_2017-04-24_at_5.37.11_PM.png
Entry  Fri Apr 7 00:34:28 2017, Koji, Electronics, Sensors, Final assembly of the new QPD circuit 7x
    Reply  Fri Apr 7 18:42:35 2017, Rich, Electronics, Sensors, Final assembly of the new QPD circuit 
       Reply  Fri Apr 7 19:01:09 2017, Koji, Electronics, Sensors, Final assembly of the new QPD circuit head_wiring.JPG
          Reply  Tue Apr 11 21:38:05 2017, Koji, Electronics, Sensors, Final assembly of the new QPD circuit DSC_0340.JPGDSC_0341.JPG
Entry  Fri Apr 7 20:31:20 2017, pyNQ, Things to Buy, General, pyNQ embedded stuff? 
    Reply  Sat Apr 8 11:27:50 2017, johannes, Things to Buy, General, pyNQ embedded stuff? 
       Reply  Tue Apr 11 16:24:46 2017, johannes, Things to Buy, General, pyNQ embedded stuff? 
Entry  Tue Mar 21 17:15:20 2017, johannes, Things to Buy, DAQ, RedPitaya 
    Reply  Thu Apr 6 20:22:22 2017, johannes, Notes, DAQ, FPGA software and Matlab versions on gaston simulink_dsp.png
       Reply  Sat Apr 8 23:52:14 2017, johannes, Notes, DAQ, Got the RedPitaya compilation flow working xilinx_flow.pngTFAG4395A_08-04-2017_233726.pdfTFAG4395A_08-04-2017_233456.pdf
Entry  Fri Apr 7 18:15:48 2017, brittany, DailyProgress, Cryo Q, MEDM screens 
Entry  Fri Apr 7 14:44:43 2017, brittany, Lab Infrastructure, Cleanliness, Operation CryoLab Revitalization 
Entry  Fri Apr 7 14:36:25 2017, brittany, Update, Cryo Q, JaNS Voyager Q_UncoatedSilicon.pdfMarchLVCposter.png
Entry  Wed Apr 5 00:12:20 2017, Aaron, Summary, Cryo Q, Timeline from last week's cryo meeting 
Entry  Tue Apr 4 17:13:22 2017, rana, Notes, Cryo, soft copper straps 
Entry  Tue May 10 15:37:11 2016, Zach, Summary, Optics, Coastline 1550nm Si optics inventory 
    Reply  Thu May 12 08:19:36 2016, Chris, Summary, Optics, Coastline 1550nm Si optics inventory 
       Reply  Sat Mar 18 16:43:32 2017, johannes, Summary, Optics, Coastline 1550nm Si optics inventory 
          Reply  Mon Mar 20 16:49:21 2017, Chris, Summary, Optics, Coastline 1550nm Si optics inventory 
    Reply  Fri May 13 13:37:49 2016, Zach, Summary, Optics, Coastline 1550nm Si optics inventory 
Entry  Wed Jan 4 15:38:01 2017, Chris, Computing, DAQ, cymac1 and workstation software upgrade 
    Reply  Fri Mar 10 10:41:39 2017, Chris, Computing, DAQ, cymac1 and workstation software upgrade dv.png
       Reply  Sat Mar 11 12:30:31 2017, Chris, Computing, DAQ, cymac1 and workstation software upgrade 
Entry  Wed Mar 1 17:34:08 2017, brittany, DailyProgress, Cryo Q, continuing with the ESD drive 
Entry  Tue Feb 28 22:04:35 2017, Aaron, DailyProgress, Cryo Q, Setting up the ESD, vacuum update, a few others 
    Reply  Wed Mar 1 17:27:22 2017, brittany, DailyProgress, Cryo Q, Setting up the ESD, vacuum update, a few others 
Entry  Mon Feb 27 20:17:14 2017, brittany, DailyProgress, Cryo Q, modified GeNS solidworks drawing  Substrate_Holder_50.8mm.PDF
Entry  Fri Feb 24 20:25:59 2017, brittany, DailyProgress, Cryo Q, update 
Entry  Tue Feb 21 21:40:42 2017, Aaron, Cryostat, Cryo Q, Vac quality update 
Entry  Sat Feb 18 20:23:27 2017, Aaron, Update, Cryo Q, Buying things, modifications to drawings 
Entry  Fri Feb 17 17:52:09 2017, brittany, aaron, Update, Cryo Q, This week's update 
Entry  Thu Feb 16 10:45:44 2017, Chris, Lab Infrastructure, DAQ, GPS in subbasement IMG_20170215_132204.jpgIMG_20170215_132357.jpg
Entry  Fri Feb 3 01:19:54 2017, Johannes, Noise Hunting, Beat Spectrum, Pre-Window Swap Things diffnoise_20170201.pdfCLG_20170201.pdfloop_error_20170201.pdfOLG_20170201.pdf
    Reply  Fri Feb 3 01:46:17 2017, Johannes, Cryostat, Vacuum, Pre-Window Swap Things IMG_20170202_151319471.jpgIMG_20170202_185620347.jpg2017-02-02_(1).png
       Reply  Sat Feb 4 19:02:57 2017, Johannes, Cryostat, Vacuum, Cryostat openened; breadboard alignment IMG_20170204_180947431.jpgIMG_20170204_181017218.jpg
          Reply  Wed Feb 15 01:43:20 2017, Johannes, Cryostat, Vacuum, Window Swap 6x
Entry  Mon Feb 13 16:03:21 2017, Aaron, Cryostat, Cryo Q, HV update signal-2017-02-13-155922
    Reply  Tue Feb 14 10:51:56 2017, rana, Electronics, Cryo Q, HV update 
Entry  Thu Feb 9 18:42:47 2017, brittany, DailyProgress, Cryo Q, Silicon reflectivity Reflectivity_of_Silicon.png
Entry  Wed Feb 8 20:33:05 2017, Brittany, DailyProgress, Cryo Q, HV, vacuum and optical lever 
Entry  Tue Jan 31 22:00:13 2017, Aaron, DailyProgress, Cryo Q, JeNS Update 
Entry  Sun Jan 29 20:41:34 2017, Aaron, DailyProgress, Cryo Q, JeNS update 
Entry  Sun Jan 29 20:30:05 2017, Aaron, Things to Buy, Cryo Q, Purchasing status update 
Entry  Sun Jan 29 20:11:30 2017, Aaron, Update, Drawings, V1 drawings 9x
    Reply  Sun Jan 29 20:23:50 2017, Aaron, Update, Drawings, V1 drawings 
Entry  Thu Jan 26 20:31:13 2017, brittany, DailyProgress, Cryo Q, Janky Nodal Suspension - JaNS JaNS.JPGTestOptics.JPGBeamPath.JPG
Entry  Wed Jan 25 20:32:08 2017, brittany, DailyProgress, Cryo Q, Getting started on Version 0.0  
    Reply  Thu Jan 26 09:42:04 2017, rana, DailyProgress, Cryo Q, Getting started on Version 0.0  
       Reply  Thu Jan 26 10:58:43 2017, rana, DailyProgress, Cryo Q, Getting started on Version 0.0  
Entry  Tue Jan 24 16:19:49 2017, brittany, Update, Cryo Q, Parts list on wiki 
Entry  Fri Jan 6 15:03:53 2017, Johannes, Summary, General, Cryocav update 7x
    Reply  Fri Jan 13 12:44:38 2017, Johannes, Summary, General, Flat noise causes 20170111_BeatNoise.pdf
       Reply  Mon Jan 16 09:02:31 2017, Johannes, Summary, Noise Budget, Flat noise causes 
          Reply  Mon Jan 16 21:01:27 2017, Johannes, Summary, Noise Budget, Beats™ by JE Noise_comp.pdf
             Reply  Thu Jan 19 09:05:49 2017, Johannes, Noise Hunting, Beat Spectrum, Modulation depths beat_170118.pdf
                Reply  Thu Jan 19 09:19:01 2017, rana, Noise Hunting, Beat Spectrum, Modulation depths 
                   Reply  Thu Jan 19 23:19:09 2017, Johannes, Noise Hunting, Beat Spectrum, Composite measurement fnoise_170119.pdf
                      Reply  Tue Jan 24 08:43:28 2017, Johannes, Noise Hunting, Beat Spectrum, More spectra fnoise_free_delay_20170121_2.pdffnoise_lock_hf2li_20170121.pdf
Entry  Tue Jan 17 17:27:33 2017, brittany, Electronics, Cryo Q, QPD status 6x
    Reply  Wed Jan 18 19:35:34 2017, Koji, Electronics, Cryo Q, QPD status DSC_0175.JPG
Entry  Tue Jan 17 15:09:00 2017, Koji, Electronics, General, EOM resonant driver circuit Kit 
Entry  Mon Jan 16 14:02:12 2017, Aaron, DailyProgress, Purchases, Calibrated temperature probe 
    Reply  Mon Jan 16 15:31:02 2017, Aaron, DailyProgress, Purchases, Calibrated temperature probe 
Entry  Mon Jan 16 15:26:51 2017, Aaron, Misc, Cryo Q,  170116_InitCooldown.nb170116_InitCooldown.pdf435713.pdf
Entry  Fri Jan 13 18:04:51 2017, brittany, Notes, Cryo Q, Gameplan for the next several weeks 
Entry  Thu Dec 15 18:42:18 2016, Rich Abbott, HowTo, Beat Spectrum, Valon Frequency Synthesizer Evaluation PhaseNoiseNotes.pdf
Entry  Thu Dec 15 01:23:51 2016, Zach, Update, Si fab, First attempt at cantilever with hole fabrication 20161214_184437.jpg20161214_184510.jpg20161214_184532.jpg20161214_184620.jpg20161214_184638.jpg
Entry  Mon Dec 12 10:29:36 2016, brittany, DailyProgress, Cryo Q, Misc. Updates from last week 
Entry  Thu Dec 1 11:50:13 2016, Aaron, DailyProgress, Cryo Q, Getting to know our cryo RTLeak.png20161201_110523.png20161201_114727.png
Entry  Wed Nov 30 11:27:10 2016, johannes, Computing, General, Zurich HF2LI zurich_test.png
Entry  Mon Nov 28 19:24:09 2016, brittany, DailyProgress, , Diodes and updates 
    Reply  Mon Nov 28 19:25:40 2016, brittany, DailyProgress, , Diodes and updates 
Entry  Sun Nov 27 00:24:41 2016, Johannes, Lab Infrastructure, Lab Work, CryoCavs table preparation filter_units.jpgfloor_bolts.jpglaser_safety_curtain.jpgturbo_pump_tubing.jpg
Entry  Tue Nov 22 19:15:12 2016, brittany, Cryostat, Lab Work, Vacuum Pressure & First cool test 
Entry  Mon Nov 21 20:30:18 2016, Aaron, Cryostat, Cryo Q, Updates on vacuum, cryo cleaning, parts; mystery crud in pressure gauge 
Entry  Thu Nov 10 14:50:19 2016, Aaron, Update, Cryo Q, Drawings sent to Eddie 11x
    Reply  Fri Nov 11 14:56:48 2016, Aaron, Update, Cryo Q, Drawings sent to Eddie 12x
Entry  Mon Oct 10 16:55:06 2016, Johannes, Cryostat, Drawings, First shot at flange mount for new windows OneInchWindow.pdf
    Reply  Tue Oct 11 18:49:22 2016, Chris, Cryostat, Drawings, First shot at flange mount for new windows 
       Reply  Fri Oct 14 16:06:20 2016, Johannes, Cryostat, Drawings, Second shot at flange mount for new windows OneInchWindow_v2_assembly.PDFOneInchWindows.zip
          Reply  Fri Oct 14 17:29:29 2016, Chris, Cryostat, Drawings, Second shot at flange mount for new windows 
             Reply  Mon Oct 17 11:40:56 2016, Johannes, Cryostat, Drawings, Focal lengths for lenses cav2nd_lens.png
             Reply  Wed Oct 19 14:28:58 2016, Johannes, Cryostat, Drawings, Viewport flange 
                Reply  Wed Oct 19 17:07:11 2016, Chris, Cryostat, Drawings, Viewport flange 
                   Reply  Fri Oct 21 12:28:19 2016, Johannes, Cryostat, Drawings, Viewport flange flange_spacing.PDFLIGO-D1600403_OneInchWindow_v2_perspective_view.PDF
                      Reply  Fri Nov 11 12:53:25 2016, Johannes, Cryostat, Drawings, Viewport flange: angles on cryostat cryostat_window_angles.pdf
Entry  Wed Oct 19 10:36:05 2016, Johannes, Notes, Optical Contacting, Second optical contacting attempt 
    Reply  Wed Oct 19 17:24:24 2016, Chris, Notes, Optical Contacting, Second optical contacting attempt IMG_20161018_164809.jpgIMG_20161018_165221.jpgIMG_20161018_165445.jpgIMG_20161018_174343.jpg
       Reply  Thu Nov 3 19:08:36 2016, Johannes, Update, Optical Contacting, First successful silicon contacting attempt 
          Reply  Mon Nov 7 14:43:32 2016, Chris, Update, Optical Contacting, First successful silicon contacting attempt hotbond.pngbondtime.pngbondbubble.pngbondbubble2.pngcrackopen.png
Entry  Wed Oct 26 23:53:31 2016, Aaron, Update, Cryo Q, Cryo Mount, Q Drawings 7x
Entry  Fri Oct 21 08:33:24 2016, Chris, Misc, Cryo, cryo contacts solid-solid.pdf
Entry  Thu Oct 20 12:18:38 2016, Aaron, Update, Cryo Q, Cryo Q overview update 24x
Entry  Wed Oct 19 20:21:21 2016, Zach, Summary, Si fab, Proposed fabrication process for cantilevers with holes 6x
Entry  Wed Oct 19 14:57:36 2016, Zach, Lab Infrastructure, SiFi, Floating the table NW.jpgNE.jpgSW.jpgSE.jpg
Entry  Sat Aug 27 12:22:50 2016, Johannes, Laser, Fiber, East laser spatial mode 
    Reply  Mon Sep 12 23:17:35 2016, Johannes, Laser, Drawings, Preliminary table layout cavity input side east1st.pngeast2nd.pngwest1st.pngwest2nd.pngCryoTableDrawing.pdf
       Reply  Wed Sep 21 22:03:36 2016, Johannes, Laser, Cavity, Cavity mode correction and east system setup east1st.pngwest1st.png
          Reply  Thu Sep 22 18:06:17 2016, Johannes, Laser, Laser, Cataclysmic laser event!? lasers_i.pdfeast_iv_curve.pdf
             Reply  Thu Sep 22 19:16:26 2016, Johannes, Laser, Laser, Actual east laser IV curve  actual_east_iv_curve.pdf
                Reply  Wed Oct 19 10:01:28 2016, Johannes, Laser, Laser, RIO Planex RMA and replacements 
Entry  Tue Oct 18 05:39:21 2016, Zach, Update, SiFi, Beat found after some upgrades TRANS_lock.jpgbeat.jpgnobeat.jpg
    Reply  Wed Oct 19 04:24:18 2016, Zach, Update, SiFi, First PLL attempt not successful 20161018_224741.jpg
Entry  Fri Oct 14 17:35:42 2016, Chris, Things to Buy, General, Lens and cryostat window specifications 
Entry  Thu Jun 30 10:32:12 2016, Johannes, Lab Infrastructure, Cleanliness, Green cryostat table enclosure enclosure_assembly.JPG
    Reply  Sat Aug 20 18:55:01 2016, Johannes, Lab Infrastructure, Cleanliness, Green cryostat table enclosure 
       Reply  Mon Oct 10 17:34:27 2016, Johannes, Lab Infrastructure, Cleanliness, Green cryostat table enclosure / Updated floor plan for Cryo Lab SOP CryoCleanHood.jpglab_drawing.pdf
Entry  Fri Oct 7 17:42:41 2016, Zach, Update, SiFi, Si substrates sent to Coastline for coating with mini-mirrors 
Entry  Wed Aug 24 00:57:41 2016, Zach, Update, SiFi, Current east cavity noise spectrum suspended_E_testcav_disp_noise_vacuum_8_23_16.png
    Reply  Thu Aug 25 21:07:57 2016, Zach, Update, SiFi, West system aligned and locked, low-audio resonances still present (also in W cavity) without pump suspended_E_testcav_disp_noise_comparison_8_24_16.pngsuspended_E_testcav_disp_noise_comparison_zoom_8_24_16.pngsuspended_testcav_disp_noise_spectra_air_8_24_16.pngsuspended_testcav_disp_noise_spectra_air_with_best_8_24_16.png
Entry  Mon Aug 22 23:53:34 2016, Zach, Update, SiFi, Chamber re-closed, pumping down 
Entry  Thu Aug 18 10:53:50 2016, Johannes, Update, Lab Work, Beat acquisition and SiCav temp modulation 
    Reply  Sat Aug 20 18:33:40 2016, Johannes, Update, Lab Work, Beat note frequency noise FrequencyNoise.pdfTPD_VoltageDip.jpg
Entry  Sat Aug 20 10:52:03 2016, rana, Computing, General, SVN->GIT 
Entry  Thu Aug 18 21:08:48 2016, Zach, Update, SiFi, New blade stops installed 20160818_154417.jpg
Entry  Sat Jun 11 02:07:33 2016, Zach, Cryostat, SiFi, Blade stop V2 Screen_Shot_2016-06-11_at_2.00.17_AM.pngScreen_Shot_2016-06-10_at_8.15.05_PM.pngScreen_Shot_2016-06-10_at_8.14.00_PM.pngScreen_Shot_2016-06-10_at_8.14.36_PM.pngScreen_Shot_2016-06-10_at_8.13.45_PM.png
    Reply  Thu Jun 16 17:06:36 2016, Zach, Cryostat, SiFi, Blade stop V2 
       Reply  Mon Aug 8 22:47:03 2016, Zach, Cryostat, SiFi, Blade stop V2 arrived 20160808_160949.jpg
Entry  Mon Aug 1 18:08:33 2016, rana, Computing, General, Cryo Wiki software update from Dokuwiki2010 to June-2016 
    Reply  Sun Aug 7 02:26:03 2016, rana, Computing, General, Cryo Wiki software update from Dokuwiki2010 to June-2016 
Entry  Sun Jul 31 23:25:37 2016, rana, Things to Buy, Sensors, On the topic of viewers, cards, and cameras for 1550 nm IRVcurve_B-S_600w.gifScreen_Shot_2016-07-31_at_11.30.29_PM.pngScreen_Shot_2016-08-01_at_7.30.32_PM.png
    Reply  Mon Aug 1 11:46:28 2016, Chris, Things to Buy, Sensors, On the topic of viewers, cards, and cameras for 1550 nm 
Entry  Sun Jul 17 20:37:12 2016, Zach, Update, SiFi, 3rd suspension wire re-pulled, suspension test-hung 20160615_173246.jpg20160615_173347.jpg20160717_192426.jpg20160717_192440.jpg
    Reply  Mon Jul 25 06:47:24 2016, Zach, Update, SiFi, Payload re-balanced, lowered into chamber, laser realigned, cavity locked, noise check and pumpdown o-ring_solution.png20160725_035851.jpgsuspended_E_testcav_disp_noise_7_24_16.png
       Reply  Mon Jul 25 23:20:17 2016, Zach, Update, SiFi, Noise measurement in vacuum -- scattered light is bad suspended_E_testcav_disp_noise_airvsvac_7_25_16.png
          Reply  Wed Jul 27 05:26:38 2016, Zach, Update, SiFi, Optical surfaces, cryostat cleaned 20160726_225048.jpg20160727_001515.jpg20160727_004558.jpg
             Reply  Fri Jul 29 12:02:57 2016, Zach, Update, SiFi, Scattering noise improved suspended_E_testcav_disp_noise_air_opticscleaned_isolator_7_28_16.png
Entry  Tue Jul 5 21:37:01 2016, Nizar, Laser, Plots, Week 2-3 (East laser profiles) better.jpg
Entry  Wed Jun 29 17:19:42 2016, Zach, Things to Buy, Suspension, Copper suspension ferrule outside of MillItNow capabilities as currently designed 
Entry  Mon Jun 27 17:55:51 2016, Chris, Electronics, DAQ, cymac AA/AI chassis work and DAC troubleshooting daqsnap.pngIMG_20160624_203506.jpg
Entry  Wed Jun 22 02:20:00 2016, Zach, Update, Si fab, New wafers received 20160621_182706.jpg
Entry  Tue Jun 21 14:28:39 2016, Subham, Notes, Cryo, Cryostat Base Diameter 
Entry  Fri Jun 17 11:39:30 2016, Johannes, Things to Buy, General, Bare necessities wishlist 
Entry  Tue Jun 14 17:24:31 2016, Zach, DailyProgress, SiFi, De-mothball suspended_E_testcav_OLTF_6_13_16.pngsuspended_E_testcav_disp_noise_6_13_16.png
Entry  Tue Jun 7 11:18:51 2016, Subham, Summary, , Update : Week 2 and 3 6x
Entry  Wed May 25 00:45:28 2016, Johannes, Lab Infrastructure, Lab Work, Table Swap IMG_20160524_145247419.jpgIMG_20160524_145240860.jpg
Entry  Fri May 20 12:21:36 2016, Subham, Update, Cryo, SURF - First Week Update 
    Reply  Fri May 20 19:18:35 2016, Johannes, Update, Cryo, New current driver 
Entry  Sat Apr 30 14:42:33 2016, Johannes, Cryostat, Vacuum, Green cryostat baking: planning 
    Reply  Tue May 3 10:38:10 2016, Johannes, Cryostat, Vacuum, Green cryostat baking: paint tested cryogreenGun.jpg
       Reply  Wed May 4 16:32:38 2016, Johannes, Cryostat, Vacuum, Green cryostat baking: heating tapes IMG_20160504_105538653.jpg
          Reply  Wed May 4 20:56:25 2016, Chris, Cryostat, Vacuum, Green cryostat baking IMG_20160504_191621.jpg
             Reply  Wed May 4 22:10:41 2016, Johannes, Cryostat, Vacuum, Green cryostat baking 
                Reply  Thu May 5 08:05:46 2016, Steve, Cryostat, Vacuum, Green cryostat baking: o-ring sizes 
                   Reply  Mon May 9 08:13:58 2016, Steve, Cryostat, Vacuum, Green cryostat baking: more epoxy 
                      Reply  Mon May 9 16:50:58 2016, Steve, Cryostat, Vacuum, Green cryostat baking: more tapes bakeGready.jpg
                         Reply  Tue May 10 10:13:02 2016, Steve, Cryostat, Vacuum, The Green Cryostat Baking 99.8C.jpg
                            Reply  Thu May 19 16:51:29 2016, Steve, Cryostat, Vacuum, after Green Cryostat Baking afterBakePdn.jpg
Entry  Wed May 11 14:21:42 2016, Steve, Update, Vacuum, heating Pfeiffer HiCube80Eco turbo pump 
Entry  Sun Apr 17 08:12:45 2016, Chris, Computing, DAQ, more CDS housekeeping 
    Reply  Tue May 3 10:30:39 2016, Chris, Computing, DAQ, more CDS housekeeping 
Entry  Wed Apr 20 17:55:07 2016, Johannes, Update, Cavity, New Si cavity noise budget oldbudgetnewcav.pdfnewbudget.pdf
Entry  Thu Apr 14 15:06:37 2016, Chris, Computing, DAQ, "fb" computer updated and rechristened "cryoaux" 
Entry  Wed Apr 13 18:56:29 2016, Chris, Computing, DAQ, cymac1 disk failures 
Entry  Mon Apr 11 19:38:52 2016, Johannes, Things to Buy, Fiber, Glance at fiber pickoff Exp_with_RefCav.pdf
Entry  Wed Apr 6 21:07:56 2016, Johannes, DailyProgress, Cavity, Comsol simulations for cavity shelf_spacer_quartered.pngshelf_spacer_mesh.pngvert_coupling.pdfshelf_spacer_drummode.png
    Reply  Thu Apr 7 18:29:59 2016, Johannes, DailyProgress, Cavity, Comsol simulations for cavity cavity_sagging_vertical_susp_plane.png
Entry  Mon Apr 4 14:27:31 2016, Johannes, DailyProgress, General, Wiki pages 
Entry  Thu Mar 24 13:03:21 2016, Chris, Cryostat, Cryo, green cryostat hold time: ~27h cool.png
Entry  Tue Mar 22 13:55:11 2016, Chris, Lab Infrastructure, Cryo, LN2 dewar exchanged IMG_20160322_135427.jpg
    Reply  Tue Mar 22 16:08:13 2016, Dmass, Lab Infrastructure, Cryo, LN2 dewar exchanged 04.png
Entry  Mon Feb 1 18:03:38 2016, Chris, Cryostat, Vacuum, Green cryostat pumpdown curve pumpdown.png
    Reply  Tue Feb 2 14:40:40 2016, Dmass, Cryostat, Vacuum, Green cryostat pumpdown curve 
    Reply  Mon Mar 7 14:52:46 2016, Chris, Cryostat, Vacuum, Green cryostat pumpdown curve pumpdown.pngpumpdown.ipynb.gz
       Reply  Wed Mar 9 01:27:18 2016, rana, Cryostat, Vacuum, Green cryostat pumpdown curve 
          Reply  Fri Mar 11 17:28:50 2016, Chris, Cryostat, Vacuum, Green cryostat pumpdown curve 
             Reply  Mon Mar 14 09:22:01 2016, Steve, Cryostat, Vacuum, Green cryostat pumpdown curve 
             Reply  Wed Mar 16 18:08:16 2016, Chris, Cryostat, Vacuum, Green cryostat pumpdown curve IMG_20160316_170853.jpg
                Reply  Wed Mar 16 23:45:48 2016, Chris, Cryostat, Vacuum, Green cryostat pumpdown curve pumpdown.pngpumpdown.ipynb.gz
Entry  Mon Feb 29 15:29:12 2016, Steve, Cryostat, Vacuum, FTIR samples FTIRsample.png
    Reply  Fri Mar 11 17:44:01 2016, Chris, Cryostat, Vacuum, FTIR samples Cryostat_Swabs_03-11.pdf
Entry  Fri Mar 4 00:49:19 2016, Zach, Update, SiFi, Cryostat closed, E cavity relocked and noise remeasured 20160303_184311.jpg20160303_190922.jpg20160303_205034.jpg20160303_224648.jpgsuspended_enclosed_E_test_cav_dispn_3_3_16.png
    Reply  Fri Mar 4 01:41:48 2016, Zach, Update, SiFi, Quick COMSOL model of the suspended payload modes Screen_Shot_2016-03-04_at_1.28.36_AM.pngScreen_Shot_2016-03-04_at_1.28.26_AM.pngScreen_Shot_2016-03-04_at_1.28.49_AM.png
    Reply  Fri Mar 4 18:49:27 2016, Zach, Update, SiFi, More noise measurements after letting suspension ring down further and installing custom electronics Screen_Shot_2016-03-04_at_6.29.27_PM.pngsuspended_E_test_cav_gyroRFPD_uPDH_OLTF_3_4_16.pngsuspended_enclosed_E_test_cav_wandwo_customelectronics_dispn_3_4_16.png
       Reply  Sat Mar 5 19:04:04 2016, Koji, Update, SiFi, More noise measurements after letting suspension ring down further and installing custom electronics 
       Reply  Wed Mar 9 00:16:12 2016, Zach, Update, SiFi, Phase lag investigation and attempt and breadboard-mirror mode damping SiFi_E_suspended_testcav_OLTF_vs_electronics_3_8_16.pnguPDH_1347_TF_3_8_16.png
          Reply  Thu Mar 10 03:06:27 2016, Zach, Update, SiFi, Payload body mode damping not very successful, and more phase lag investigation suspended_E_testcav_disp_noise_beforeafter_foil_3_9_16.pngsuspended_E_testcav_OLTF_vs_PD_3_9_16.png
Entry  Mon Mar 7 21:00:02 2016, Johannes, Notes, Cavity, Short cryo cavity design weff_vs_roc.pdfcbn_vs_roc.pdf
Entry  Thu Mar 3 02:45:27 2016, Zach, Update, SiFi, Test cavities assembled on breadboard, breadboard balanced, suspended in air, early locking and noise 6x
Entry  Fri Feb 26 18:47:22 2016, Zach, Update, SiFi, Cold plate test hang, test michelson 20160226_145258.jpg20160226_165355.jpg
Entry  Wed Feb 17 22:55:34 2016, Zach, Update, SiFi, Suspension wires pulled, suspension assembled and test hanged 20160217_191240.jpg20160217_211007.jpg
    Reply  Thu Feb 25 13:00:56 2016, Zach, Update, SiFi, Third suspension wire re-pulled and clamp, test hang redone 20160218_175720.jpg20160218_175813.jpg20160218_180729.jpg20160218_181031.jpg
Entry  Thu Feb 11 12:37:02 2016, Chris, Photos, Cryo, Cryostat mylar-ectomy IMG_20160210_165159.jpgIMG_20160210_165503.jpgIMG_20160210_165433.jpgIMG_20160210_165852.jpg
    Reply  Fri Feb 12 20:20:49 2016, Dmass, Photos, Cryo, Cryostat mylar-ectomy 
Entry  Wed Feb 3 20:17:56 2016, Zach, Update, SiFi, Suspension parts received, unpacked and checked SiFi_sus1.pngSiFi_sus3.png
Entry  Thu Jan 28 17:56:04 2016, Chris, Cryostat, General, Cryostat reassembly in progress IMG_20160128_163828.jpg
Entry  Thu Jan 28 14:37:56 2016, Dmass, Electronics, ,  
Entry  Thu Jan 28 14:29:17 2016, Zach, Cryostat, SiFi, Thermal calculation with COMSOL SiFi_COMSOL_iso.pngSiFi_COMSOL_yz.pngSiFi_COMSOL_xy.pngSiFi_COMSOL_24h_holes.pngSiFi_COMSOL_24h_noholes.png
Entry  Mon Jan 25 23:47:53 2016, rana, Cryostat, Drawings, Green Monster drawings 
    Reply  Thu Jan 28 02:53:03 2016, Dmass, Cryostat, Drawings, Cryostat investigations 
       Reply  Thu Jan 28 08:23:46 2016, Steve, Cryostat, Drawings, Cryostat investigation pictures susCavSidBack.jpgsusCavFrontCabl.jpgfoilIns.jpgtopInsRemdg10vents.jpg
       Reply  Thu Jan 28 09:35:51 2016, Chris, Photos, Cryo, Cryostat disassembly photos 11x
       Reply  Thu Jan 28 13:09:57 2016, Dmass, Cryostat, Drawings, Cryostat upgrade 
Entry  Thu Jan 28 02:38:54 2016, Zach, Update, SiFi, Received OMC copper ferrules for suspension ferrule1.jpgferrule2.jpgScreen_Shot_2015-11-25_at_1.46.43_PM.png
Entry  Thu Jan 21 13:04:09 2016, Dmass, Electronics, General, New AA board (in works) AA_schematics.png
Entry  Thu Jan 21 02:51:42 2016, Zach, Cryostat, SiFi, Large cryostat pumping SiFi_cryostat_pumping.jpg
Entry  Thu Jan 21 02:42:41 2016, Zach, Electronics, SiFi, OCXO box used to lock lasers to test PMC OCXO_in_rack.jpgPMC_OLTFs_with_OCXO_1_20_16.png
Entry  Tue Jan 12 10:50:12 2016, Steve, Cryostat, General, moving cryostat horCry050.jpg
Entry  Tue Jan 5 15:18:25 2016, Brian, Notes, material properties, Coating material properties at cryogenic temperatures 
Entry  Mon Jan 4 20:05:01 2016, Zach, Electronics, SiFi, Made five 2-m LIGO power cables for rack electronics 20160104_165558.jpg
Entry  Wed Dec 9 19:41:02 2015, Brian, Computing, Noise Budget, Cryo cavity upgrade noise budget 
Entry  Fri Dec 4 16:51:49 2015, Brian, Laser, Laser, Laser actuation range westPower.pngeastPower.png
Entry  Wed Dec 2 21:16:59 2015, Chris, Lab Infrastructure, DAQ, Vacuum gauge and particle count scripts revived 
Entry  Fri Mar 14 01:54:04 2014, Dmass, DailyProgress, Beat Spectrum, PLL implemented, 10x improvement in noise PLL_loop_doodle.pngBeat_300K_3_14_14.pdfPLL_OLTF_3_14_14.pdf
    Reply  Fri Mar 14 17:11:39 2014, Dmass, DailyProgress, Beat Spectrum, Updated Noisebudget with New Beat NoiseBudget.pdf
       Reply  Sat Mar 15 23:52:42 2014, rana, Noise Hunting, Beat Spectrum, Updated Noisebudget with New Beat + JILA NoiseBudget_plus.pdf
          Reply  Tue Mar 18 16:10:09 2014, Dmass, Noise Hunting, Beat Spectrum, JILA Si cavity frequency noise Avar2fnoiseASDderiv.pdfNIST_res.pdf
             Reply  Wed Nov 25 19:50:05 2015, rana, Noise Hunting, Beat Spectrum, JILA Si cavity frequency noise 
                Reply  Mon Nov 30 14:08:14 2015, Dmass, Noise Hunting, Beat Spectrum, JILA Si cavity frequency noise 
          Reply  Fri Apr 4 17:17:57 2014, Dmass, Noise Hunting, Beat Spectrum, Scatter improvemen BeatCompare.pdf
             Reply  Mon Apr 7 19:01:33 2014, Dmass, Noise Hunting, Beat Spectrum, PLL calibration PLL_Calibration.pdfBeatCompare.pdf
                Reply  Tue Apr 22 20:15:36 2014, Dmass, Noise Hunting, Beat Spectrum, PLL calibration beat300K_4_22_14.pdf
       Reply  Sun Mar 16 18:53:00 2014, Dmass, DailyProgress, Beat Spectrum, Updated Noisebudget with New Beat PDH_Params.pngMode_Mismatch.pngDemod_gain.png
          Reply  Wed Mar 19 01:23:49 2014, Dmass, DailyProgress, Beat Spectrum, Updated Noisebudget with New Beat 
Entry  Tue Oct 27 17:02:02 2015, Brian, DailyProgress, Cavity, Effect of thermal expansion on mirror ROC 
Entry  Mon Oct 12 19:33:46 2015, Brian, DailyProgress, Optics, Effect of waveplate misalignment on reflected power waveplate.pdf
Entry  Fri Oct 9 18:42:19 2015, Brian, DailyProgress, Transfer Functions, LB1005 and Pomona box transfer functions West.pdfEast.pdf
Entry  Wed Sep 23 18:11:25 2015, Zach, DailyProgress, SiFi - ringdown, Room temp Q of most recent CIT cantilever > 10^5! cantilever.jpgcantilever_surface.jpgringdown.jpg
    Reply  Fri Oct 2 19:20:10 2015, Zach, DailyProgress, SiFi - ringdown, Cryogenic Q of CIT cantilever ~500k CIT_cantilever_100K_amp_activephi_10_2_15.png
       Reply  Thu Oct 8 13:18:45 2015, Zach, DailyProgress, SiFi - ringdown, PEEK problems again? 
Entry  Thu Oct 8 13:08:21 2015, Zach, Electronics, SiFi, Second laser driver acquired WpoiWHhT9Kz-cFNoh4cglrBKWVS-8sEXwohajXWMySw.jpeg
Entry  Fri Oct 2 19:03:48 2015, Zach, Lab Infrastructure, Cryo, LN2 refilled, new dewar #230 
Entry  Thu Sep 17 14:40:15 2015, Brian, Electronics, Sensors, Noise in HP HP.pdf
Entry  Tue Jun 10 10:11:15 2014, Evan, Dmass, Nic, DailyProgress, PDH, Diode driver + laser transfer function measurement 7x
    Reply  Wed Jun 25 22:41:37 2014, Dmass, DailyProgress, PDH, TRUE Diode driver + laser transfer function measurement W_DriveCabLasTF.pdf
       Reply  Fri Jun 27 14:19:25 2014, Dmass, DailyProgress, PDH, Marconi TF Marconi_Meas.pdfIFR_response.pdf
       Reply  Fri Jun 27 15:16:43 2014, Dmass, DailyProgress, PDH, Laser TF measurement setup Curr_Driv_3_meas.pdfLaser_TF.pdfLaser_TF_PLL_Cal.pdfIFR_response.pdfW_DriveCabLasTF.pdf
          Reply  Tue Jul 1 14:42:31 2014, Dmass, DailyProgress, PDH, Laser TF measurement setup 6x
             Reply  Wed Jul 9 01:10:42 2014, Dmass, DailyProgress, PDH, Made new low pass filters for after mixer MeasSummary.pdf
                Reply  Tue Jul 15 20:03:48 2014, Dmass, DailyProgress, PDH, Total PDH Open Loop Transfer Function Budget PDH_OLTF_allsubplots.pdf
                   Reply  Wed Jul 16 19:42:25 2014, Dmass, DailyProgress, PDH, Total PDH Open Loop Transfer Function Budget 
                   Reply  Wed Sep 16 11:05:44 2015, Dmass, DailyProgress, PDH, Total PDH Open Loop Transfer Function Budget PDHLBPhaseBud.pdf
Entry  Mon Nov 3 15:16:28 2014, Dmass, Noise Hunting, Noise Budget, New beat spectrum: ErrSigs.pngBeatNz.png
    Reply  Mon Nov 3 16:15:21 2014, Dmass, Noise Hunting, Noise Budget, Beat spectrum not ltd by  
       Reply  Mon Nov 3 20:27:28 2014, Dmass, Noise Hunting, Noise Budget, ISS servo fail? 
          Reply  Wed Nov 19 14:54:36 2014, nicolas, Noise Hunting, Noise Budget, ISS servo fail?  
       Reply  Tue Dec 2 22:51:52 2014, Dmass, Noise Hunting, Noise Budget, Beat spectrum not ltd by  PDH_demod_chain.png
          Reply  Sat Sep 12 14:25:05 2015, Dmass, Noise Hunting, Noise Budget, Beat spectrum not ltd by  
    Reply  Mon Nov 3 20:36:14 2014, Dmass, Noise Hunting, Noise Budget, New beat spectrum: 
       Reply  Tue Nov 25 22:45:43 2014, Dmass, Noise Hunting, Noise Budget, New beat spectrum: 
          Reply  Wed Dec 3 17:02:31 2014, Dmass, Noise Hunting, Noise Budget, Noise budget cleaning up 
             Reply  Thu Dec 4 02:45:49 2014, Dmass, Noise Hunting, Noise Budget, Noise budget cleaning up PDH_sensing_nz.pngLB1005inputNoise.png
                Reply  Sun Dec 7 12:42:55 2014, rana, Noise Hunting, Noise Budget, Scatter Noise hump is RAM 
Entry  Thu Aug 27 18:41:43 2015, Brian, HowTo, Lab Work, Experimental setup characterization 
    Reply  Thu Aug 27 19:05:53 2015, Brian, DailyProgress, Lab Work, Experimental setup characterization 
    Reply  Fri Aug 28 17:02:41 2015, Brian, DailyProgress, Lab Work, Experimental setup characterization 
    Reply  Mon Aug 31 17:33:31 2015, Brian, DailyProgress, Lab Work, Experimental setup characterization 
    Reply  Wed Sep 9 18:39:36 2015, Brian, DailyProgress, Lab Work, Experimental setup characterization 
       Reply  Fri Sep 11 16:03:21 2015, Brian, DailyProgress, Lab Work, Explanation for small PM 
          Reply  Sat Sep 12 13:53:21 2015, Dmass, DailyProgress, Lab Work, Explanation for small PM 
Entry  Thu Aug 20 19:29:29 2015, Brian, DailyProgress, COMSOL, Seismic transfer function model in COMSOL TF.pdf
    Reply  Fri Aug 21 16:00:05 2015, Dmass, DailyProgress, COMSOL, Seismic transfer function model in COMSOL 
       Reply  Tue Aug 25 16:54:15 2015, Brian, DailyProgress, COMSOL, Seismic transfer function model in COMSOL TF.pdf
          Reply  Tue Aug 25 19:02:54 2015, Brian, DailyProgress, COMSOL, Seismic transfer function model in COMSOL 8x
             Reply  Thu Sep 10 10:47:46 2015, Dmass, DailyProgress, COMSOL, Seismic transfer function model in COMSOL 
                Reply  Thu Sep 10 18:13:37 2015, Brian, DailyProgress, COMSOL, Seismic transfer function model in COMSOL TF_fit.pdfTF_fit2.pdf
                   Reply  Thu Sep 10 21:31:24 2015, Koji, DailyProgress, COMSOL, Seismic transfer function model in COMSOL 
                      Reply  Fri Sep 11 15:39:28 2015, Brian, DailyProgress, COMSOL, Seismic transfer function model in COMSOL TF_fit.pdf
Entry  Wed Sep 9 17:15:03 2015, Brian, DailyProgress, PDH, EOM modulation depth 
    Reply  Thu Sep 10 10:44:57 2015, Dmass, DailyProgress, PDH, EOM modulation depth 
Entry  Sun Sep 6 15:43:40 2015, Zach, Summary, Si fab, Si fab process photo walkthrough 21x
Entry  Wed Aug 26 17:55:14 2015, Zach, Laser, SiFi, Diode driver problems LD_driver_in_rack.jpgREFL_ThorLabs.jpgREFL_custom.jpg
    Reply  Wed Sep 2 12:53:01 2015, Zach, Laser, SiFi, Diode driver fixed PMC_REFL.jpg
       Reply  Fri Sep 4 01:15:52 2015, Zach, Laser, SiFi, Diode driver fixed (*really* this time) 
          Reply  Sat Sep 5 15:07:55 2015, Zach, Laser, SiFi, Bandwidth and noise with new driver test_PMC_OLTFs_9_4_15.pngPMC_laser_freqnoise_9_4_15.png
Entry  Tue Sep 1 16:46:05 2015, Brian, Misc, Cleanliness, Ant traps 2015-09-01_16.30.02.jpg2015-09-01_16.30.11.jpg2015-09-01_16.30.27.jpg
Entry  Thu Aug 27 19:49:50 2015, Zach, Update, SiFi, KNI update 
Entry  Mon Aug 24 23:44:26 2015, Zach, Lab Infrastructure, SiFi, DC power for rack sorensens.jpgpower_strip.jpg
Entry  Mon Aug 17 11:49:29 2015, Matt, DailyProgress, SiFi, Long Glasgow Q measurement glasgowloss.jpg
Entry  Thu Aug 13 22:36:02 2015, Dmass, Cryostat, Noise Budget, Boiling Noise Measurement wilcg10nzflr.pdfVertCryostatSeismic.pdfLongCryostatSeismic.pdfTanCryostatSeismic.pdf
    Reply  Sat Aug 15 17:10:07 2015, Dmass, Cryostat, Noise Budget, Boiling Noise on top of beat SeismicatPlatform.pdfSeismicNoiseatBeat.pdf
Entry  Thu Sep 5 15:57:26 2013, Evan, DailyProgress, Simulation, First go at cavity seismic coupling in Comsol cryo_cav_comsol.jpgcryo_cav_sagging.pdfcavity_length_change.pdf
    Reply  Tue Sep 10 13:37:40 2013, Evan, DailyProgress, Simulation, Second go at cavity seismic coupling in Comsol long_mirror_disp.pdfvert_mirror_disp.pdf
       Reply  Tue Sep 10 19:01:48 2013, Dmass, DailyProgress, Simulation, Suspension 
       Reply  Thu Sep 12 15:20:57 2013, Evan, DailyProgress, Simulation, Second go at cavity seismic coupling in Comsol cryo_mirror_displacement.pdfcryo_mirror_tilt.pdfcryo_mirror_total.pdfcav_freq_per_g.pdf
          Reply  Thu Sep 19 12:59:19 2013, Evan, DailyProgress, Simulation, Scripts for cavity seismic coupling in Comsol cavity_freq.pdf
             Reply  Sun Feb 2 00:51:44 2014, Evan, DailyProgress, Simulation, Scripts for cavity seismic coupling in Comsol 
                Reply  Sun Feb 2 09:42:30 2014, Evan, DailyProgress, Simulation, Scripts for cavity seismic coupling in Comsol cavity_freq_all.pdf
                   Reply  Thu Mar 6 17:06:15 2014, Evan, DailyProgress, Simulation, Scripts for cavity seismic coupling in Comsol cavity_freq_norm.pdf
                      Reply  Thu Jul 23 19:19:33 2015, Brian, Update, Simulation, Scripts for cavity seismic coupling in Comsol cavity_freq1.pdfcavity_freq2.pdfcavity_freq3.pdfcavity_freq4.pdf
                         Reply  Mon Jul 27 15:20:51 2015, Dmass, Update, Simulation, Scripts for cavity seismic coupling in Comsol 
                            Reply  Fri Aug 14 17:12:34 2015, Brian, DailyProgress, Simulation, Scripts for cavity seismic coupling in Comsol mesh5.pdfmesh3.pdfsupps_mesh5.pdfsupps_mesh3.pdf
Entry  Thu Aug 13 17:56:47 2015, Matt, DailyProgress, SiFi, More coupling coupling.png
Entry  Thu Aug 13 15:48:29 2015, Zach, Update, Lab Work, So it begins... bunny_suit_KNI.jpgbunny_suit_KNI.jpgalice-falling-down-rabbit-hole1.jpg
Entry  Wed Aug 12 17:49:26 2015, Matt, DailyProgress, SiFi, More Glasgow measurements 
Entry  Tue Aug 11 21:45:28 2015, Matt, Update, SiFi, Taiwan cantilever demise IMG_0657.JPG
Entry  Tue Aug 11 21:09:32 2015, Matt, DailyProgress, SiFi - ringdown, New Glasgow cantilever measurements 2015-08-11-143454.jpg2015-08-11-143542.jpgglasgowspectrum.pngmode2ringdown.pngIMG_0655.JPG
Entry  Mon Aug 10 21:26:29 2015, Brian, DailyProgress, Sensors, Wilcoxon accelerometer troubles 
    Reply  Tue Aug 11 17:38:22 2015, Brian, DailyProgress, Sensors, Wilcoxon accelerometer troubles 
Entry  Tue Aug 11 12:04:41 2015, Zach, Update, SiFi - ringdown, Received new Glasgow samples new_Glasgow_cantilevers.jpg
Entry  Mon Aug 10 21:36:34 2015, Brian, Cryostat, Cryo, LN2 refilling log 
Entry  Mon Jul 27 18:32:45 2015, Brian, Photos, Schematics, Map of cryo cavity setup Overall.pngA.pngB.pngC.png
    Reply  Tue Jul 28 16:17:19 2015, Dmass, Photos, Schematics, Map of cryo cavity setup ExperimentalDiagSimp.pdf
       Reply  Mon Aug 10 11:02:22 2015, Brian, Photos, Schematics, Map of cryo cavity setup Overall.pdfA.pdfB.pdfC.pdf
Entry  Tue Aug 4 14:28:03 2015, Matt, DailyProgress, SiFi, Successful simultaneous measurements 7x
    Reply  Sat Aug 8 17:34:50 2015, Dmass, DailyProgress, SiFi, Moved pump for sifi 
Entry  Fri Aug 7 17:02:37 2015, Matt, DailyProgress, General, NDS Client for MATLAB exampleplots.pdf
    Reply  Sat Aug 8 17:31:24 2015, Dmass, DailyProgress, General, NDS Client for MATLAB 
Entry  Tue Aug 4 11:29:32 2015, Matt, DailyProgress, SiFi, First cryo Q measurements IMG_0624.JPG
Entry  Thu Jul 30 18:21:38 2015, Matt, DailyProgress, SiFi, Simultaneous continuous Q measurements and starting cryo measurements 
Entry  Thu Jul 30 17:32:08 2015, Matt, Photos, SiFi, Taiwan cantilever and clamp pictures 2015-07-24-145135pre.jpg2015-07-24-145327pre.jpg2015-07-24-145443SS.jpg2015-07-24-151526post.jpg2015-07-24-152714post.jpg
Entry  Sat Jul 25 16:50:13 2015, Dmitry, DailyProgress, SiFi - ringdown, Taiwan Cantilever - Update IMG_20150724_161114_crop.jpgIMG_20150725_103617.jpgIMG_20150725_103610.jpg
Entry  Fri Jul 24 22:38:46 2015, Dmitry, Notes, Vacuum, Pfeiffer Vacuum Pump Conundrum 
Entry  Thu Jul 23 23:40:51 2015, Dmitry, DailyProgress, SiFi - ringdown, Taiwan cantilever - Ringdown - Continuous Q-measurements COMSOL_ClampingLoss_on_length.png
Entry  Tue Jul 21 19:14:52 2015, Dmitry, DailyProgress, COMSOL, More COMSOL modeling 
Entry  Thu Jul 16 21:54:10 2015, Matt, DailyProgress, COMSOL, Potential loss sources and more COMSOL modeling Painter2.pngPinwheelAssembly.png
Entry  Thu Jul 16 00:31:15 2015, Matt, Update, COMSOL, Pinwheel modeling with COMSOL and Q measurements Pinwheelmode1.pngPinwheelmode2.pngPinwheelmode3.png
Entry  Thu Jul 9 17:45:03 2015, Matt, Update, SiFi - ringdown, Ringdown measurement with new clamp newclamp.png
    Reply  Fri Jul 10 11:12:16 2015, rana, Update, SiFi - ringdown, Ringdown measurement with new clamp 
       Reply  Fri Jul 10 11:44:27 2015, Zach, Update, SiFi - ringdown, Ringdown measurement with new clamp 
    Reply  Sun Jul 12 01:21:22 2015, rana, Update, SiFi - ringdown, Ringdown measurement with new clamp 
Entry  Wed Jul 8 20:07:21 2015, Zach, Summary, SiFi - ringdown, Summary of all ringdowns thus far 
Entry  Thu Jul 2 16:15:40 2015, Zach, DailyProgress, SiFi - ringdown, Quick update on recent measurements data_analysis_plots.jpg
Entry  Sun Jun 7 17:33:31 2015, Zach, Update, SiFi - ringdown, New clamp received, second prototype cantilever made, some measurements 8x
    Reply  Wed Jun 10 18:09:39 2015, Zach, Update, SiFi - ringdown, Second prototype cantilever cryogenic Q not great 
Entry  Sun Jun 7 17:06:49 2015, Zach, Lab Infrastructure, Cryo, LN2 refilled, new dewar #200 new_dewar_200.jpg
Entry  Wed Jun 3 19:39:18 2015, Zach, Notes, SiFi, Si structure fabrication process 
Entry  Tue Jun 2 16:38:17 2015, Zach, Update, SiFi, Suspension blades acquired 20150602_162001.jpg
Entry  Wed May 27 19:23:25 2015, Zach, Update, SiFi, First prototype cantilever made cantilever_photo1.pngcantilever_photo2.pngcantilever_polish.png
Entry  Mon May 18 12:34:06 2015, Zach, Summary, SiFi, GWADW 2015 poster full_render_cutaway_crop_5_13_15.jpg
Entry  Wed May 13 06:37:30 2015, Zach, Photos, SiFi, A taste of things to come... test_render_cutaway_crop_5_12_15.jpgtest_render_sus_crop_5_12_15.jpg
    Reply  Sat May 16 15:34:47 2015, rana, Photos, SiFi, A taste of things to come... 
       Reply  Sat May 16 22:06:55 2015, Zach, Photos, SiFi, A taste of things to come... 
          Reply  Sun May 17 18:39:48 2015, Rana(?), Photos, SiFi, A taste of things to come... 
             Reply  Mon May 18 12:31:25 2015, Zach, Photos, SiFi, A taste of things to come... 
Entry  Sat Apr 11 19:03:58 2015, Zach, Electronics, Sensors, RL readout PD 6x
    Reply  Thu May 7 03:35:49 2015, Zach, Electronics, Sensors, RL readout PD with humbucking RL_readout_single_vs_humbucker_5_6_15.png
Entry  Wed May 6 18:01:02 2015, nicolas, Lab Infrastructure, Drawings, Cryostat base plate baseplate.pngbaseplatebottom.png
Entry  Thu Apr 30 18:00:47 2015, Zach, Update, SiFi, Diced wafers received diced_wafers1.jpgdiced_wafers2.jpgmaxresdefault-1.jpg
    Reply  Tue May 5 17:10:14 2015, rana, Update, SiFi, wafers received 
Entry  Thu Apr 30 17:53:20 2015, Zach, Cryostat, Purchases, Getters gotten getters.jpggit-r-done.jpg
Entry  Fri Apr 24 04:31:48 2015, Zach, Laser, SiFi, Cavities locked simultaneously, transmission setup built TRANS_setup.jpgsimultaneous_lock.jpgcavity_IO.jpg
Entry  Thu Apr 23 03:09:49 2015, Zach, DailyProgress, SiFi, Windows installed, cryostat top with cavities placed in body, cavities realigned, locked broken_window.jpgnot_broken_window.jpglocked_in_chamber.jpg
Entry  Tue Apr 14 22:27:18 2015, rana, Lab Infrastructure, Drawings, Lab Layout circa Feb. 2015 (according to Nic) CryoLabLayout_150303.png
    Reply  Tue Apr 21 21:30:50 2015, rana, Lab Infrastructure, Drawings, Lab Layout circa Feb. 2015 (according to Nic) 
Entry  Tue Apr 21 14:19:16 2015, Zach, Laser, Purchases, Fiber isolators arrived 20150421_132345.jpg
Entry  Fri Apr 17 05:15:26 2015, Zach, Laser, SiFi, Test cavities rebuilt on cold plate, aligned, locked (separately) 6x
Entry  Fri Apr 17 04:39:25 2015, Zach, Update, SiFi, Two 150mm wafers sent for dicing wafer_holders.jpgwafer_polish.jpg
Entry  Wed Apr 15 01:19:14 2015, Zach, Laser, SiFi, Input paths, frontal beat, test cavities set up and aligned, ready to lock 8x
    Reply  Thu Apr 16 15:58:02 2015, Zach, Laser, SiFi, Gyro RFPDs installed, tuned, E cavity PDH tuned and cavity locked NIM.jpggyro_PD_installed.jpgE_RFPD_Z_4_15_15.pngE_cavity_locked.jpgTEK00004.PNG
Entry  Sat Apr 11 23:42:03 2015, Zach, Notes, Mechanics, Post and base vs. pedestal and fork 6x
    Reply  Mon Apr 13 11:24:32 2015, rana, Noise Hunting, Mechanics, Post and base vs. pedestal and fork 
Entry  Thu Apr 2 20:21:18 2015, Zach, Cryostat, SiFi, Re-evacuated large cryostat 
    Reply  Sat Apr 4 18:08:18 2015, rana, Cryostat, SiFi, Re-evacuated large cryostat 
       Reply  Tue Apr 7 16:24:18 2015, Zach, Cryostat, SiFi, Getter quote 
       Reply  Wed Apr 8 21:12:19 2015, Dmass, Cryostat, SiFi, Re-evacuated large cryostat 
Entry  Thu Apr 2 01:03:33 2015, Zach, Lab Infrastructure, SiFi, Rack set up, table cleared and real layout started rack_and_table.jpglasers_and_modulators.jpg
Entry  Sun Mar 23 14:08:35 2014, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Measured WPhotoThermTF.pdfPhotoThermvsoffset.pdf
    Reply  Tue Mar 25 19:00:27 2014, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Measured 
       Reply  Wed Mar 26 19:04:47 2014, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Measured WPhototherm.pdf
          Reply  Fri Dec 12 17:15:00 2014, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Actually Measured W_Ptherm300K.png
             Reply  Thu Mar 19 14:00:21 2015, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Actually Measured 8x
                Reply  Mon Mar 23 14:23:09 2015, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Actually Measured 8x
                   Reply  Mon Mar 30 17:56:13 2015, Dmass, Noise Hunting, Noise Budget, West Photothermal Transfer Function Actually Measured lossvsT.pdf
Entry  Fri Mar 27 00:26:02 2015, Zach, Summary, SiFi - ringdown, Taiwan cantilever phi vs. T (old but unreported) Taiwan_106Hz_phi_vs_T_3_12_15.pngsteel_SUS.jpg
Entry  Thu Mar 26 20:06:02 2015, Zach, Cryostat, SiFi - ringdown, Small cryostat reassembled, Taiwan cantilever in clamp, pumping down 
Entry  Wed Dec 17 13:24:00 2014, Zach, Lab Infrastructure, SiFi, Cryostat unpacked (x-post from SUS elog) 
    Reply  Tue Mar 24 14:34:26 2015, rana, Things to Buy, Vacuum, Cryostat unpacked (x-post from SUS elog) AccuGlass275CF.pdfag_arcoating_graph_web.jpg
Entry  Thu Mar 12 18:45:50 2015, Zach, Cryostat, stuff happens, Epoxy mess 
Entry  Thu Mar 5 22:35:43 2015, Zach, DailyProgress, SiFi - ringdown, Taiwan room-temp Q > 10^5, cooling now Taiwan_ringdown_106Hz_300K_fullvacuum.jpg
    Reply  Fri Mar 6 19:02:28 2015, Zach, DailyProgress, SiFi - ringdown, Q at low temperature after reclamp… worse? ActivePhi_Taiwan_106Hz_100K_3_6_15.png
       Reply  Tue Mar 10 03:51:42 2015, Zach, DailyProgress, SiFi - ringdown, Taiwan cantilever long-term low-temperature phi ActivePhi_Taiwan_106Hz_100K_longterm_3_6_15.png
Entry  Tue Mar 10 03:19:49 2015, Zach, Computing, SiFi - ringdown, Temperature calibration and control changes new_tempcal_R2T.pngnew_master_screen.pngnew_tempcal.png
Entry  Mon Jan 12 13:10:08 2015, Dmass, Notes, Cavity, Cavity Parameters from Dec 2014 Labwork 
    Reply  Mon Jan 12 13:35:31 2015, Dmass, Notes, Cavity, Cavity Parameters from Dec 2014 Labwork CavityParameters.pdf
       Reply  Sun Mar 8 14:37:18 2015, Dmass, Notes, Cavity, 300K beat data from Dec run beat300KrawDec2014.pngPLLoltfmeasDec2014.pngPLLcalibrationsDec2014.pngbeat300KcalibratedDec2014.png
          Reply  Sun Mar 8 15:20:10 2015, Dmass, Notes, Cavity, 300K PDH data from Dec run PDHerr300KDec2014.pngPDHoltfEDec2014.pngPDHoltfWDec2014.pngPDHcalAvsPLL.png
             Reply  Sun Mar 8 16:04:23 2015, Dmass, Notes, Cavity, 300K Transmitted Spectra from Dec 2014 run TransRIN300KDec2014.png
                Reply  Sun Mar 8 17:18:52 2015, Dmass, Notes, Cavity, Coherences Coh300KBeatvsall.pngCoh300Koffdiag.pngEoverWPDHvsCoh.pngPDHcalBvsPLL.pngPDHcalBvsPLL.png
                   Reply  Sun Mar 8 18:14:39 2015, Dmass, Notes, Cavity, Subtraction CohSub300KBeatResid.png
Entry  Thu Mar 5 22:20:06 2015, Zach, Lab Infrastructure, Cryo, LN2 refilled, new dewar #102 dewar_102.jpg
Entry  Wed Mar 4 02:32:45 2015, Zach, DailyProgress, SiFi - ringdown, Si spacer added to clamp holding Taiwan cantilever Si_clamp_spacer.jpgringdown_106Hz_300K_with_spacer.jpg
Entry  Fri Feb 27 05:47:27 2015, Zach, DailyProgress, SiFi - ringdown, Taiwan cantilever fundamental mode Q phi_stats_moderinger_Taiwan_106Hz_95K_2_25_15.pngringdown_Taiwan_106Hz_95K_2_25_15.png
Entry  Mon Feb 23 14:57:23 2015, Zach, Laser, M2 ISS, 3-mm diode initial noise measurement 3mm_diode_noise_5V.png
    Reply  Mon Feb 23 17:57:49 2015, rana, Laser, M2 ISS, 3-mm diode initial noise measurement 
       Reply  Mon Feb 23 19:55:08 2015, Koji, Laser, M2 ISS, 3-mm diode initial noise measurement 
       Reply  Thu Feb 26 18:47:59 2015, Zach, Laser, M2 ISS, 3-mm diode dark current and noise 7845_turnon.PNG7843_turnon.PNG3mm_pd_noise_5V_2_25_25.png
Entry  Wed Feb 25 04:29:49 2015, Zach, DailyProgress, SiFi - ringdown, Taiwan cantilever has higher Q, going for cryo cycle now Glasgow_cantilever_dimensions.pngTaiwan_cantilever_package.jpgTaiwan_cantilever_in_chamber.jpgTaiwan_106Hz_RT_2_24_15.png
Entry  Tue Feb 24 05:17:04 2015, Zach, DailyProgress, M2 ISS, First real M2 test ISS_foam_box.jpgISS_servo_TF_2_23_15.pngM2_test_2_23_15.png
Entry  Fri Feb 20 05:41:04 2015, Zach, DailyProgress, Laser, Simple ISS test simple_ISS_2_19_15.png
Entry  Fri Feb 20 05:22:19 2015, Zach, DailyProgress, Laser, Error calibration -> actuation TFs and new laser frequency noise measurement error_scan_2_19_15.pnglaser_act_TFs_2_19_15.pngPMC_err_freqnoise_2_19_15.pngOLTF_PZT_vs_laser_2_19_15.png
Entry  Wed Feb 11 03:58:52 2015, Zach, Laser, Transfer Functions, Wipf nonlinear temperature actuation proof of principle Wipf_actuation_POP_2_10_15.png
    Reply  Thu Feb 12 15:34:12 2015, Nic, Chris, Laser, Transfer Functions, higher bandwidth frequency readout 
Entry  Wed Feb 11 03:15:02 2015, Zach, DailyProgress, SiFi - ringdown, Only some extra damping is from wires 
Entry  Tue Feb 10 04:37:05 2015, Zach, DailyProgress, SiFi - ringdown, Q consistently lower in cryostat 
Entry  Mon Feb 9 18:49:55 2015, Zach, DailyProgress, SiFi - ringdown, Q ~ 6800 at room temp with Si sandwich si_sandwich_300K_2_9_15.png
Entry  Mon Feb 9 02:59:28 2015, Zach, Lab Infrastructure, SiFi - ringdown, New vacuum chamber for rapid room-temperature iteration new_chamber.jpgsapphire_sandwich.jpgclamp_in_new_chamber.jpgwashers_not_flat.png
Entry  Sun Feb 8 02:49:27 2015, Zach, DailyProgress, SiFi - ringdown, Q still low after clamp adjustments, mode cross-coupling suspected 250Hz_modeshape.png1500Hz_modeshape.png2000Hz_modeshape.png2000Hz_strainenergy.png
Entry  Sat Feb 7 03:50:14 2015, Zach, DailyProgress, SiFi - ringdown, Electrical connections fixed, clamp adjusted, chamber repumped and cooling before.jpgwasher.jpgafter.jpg
Entry  Fri Feb 6 05:31:43 2015, Zach, Laser, SiFi, Phase modulator characterization 
Entry  Fri Feb 6 04:46:26 2015, Zach, Laser, SiFi, Beam profile remeasured, test PMC aligned well and locked W_Laser_profile_2_5_15.pngnew_PMC_setup.jpg
Entry  Thu Feb 5 02:04:39 2015, Zach, DailyProgress, SiFi - ringdown, No big Q increase at low temperature 
    Reply  Fri Feb 6 04:23:20 2015, Zach, DailyProgress, SiFi - ringdown, No big Q increase at low temperature 
Entry  Wed Jan 21 15:21:19 2015, Zach, Lab Infrastructure, Cryo, New LN2 dewar delivered trickdaddy.jpgDewar.jpg
Entry  Thu Jan 15 18:27:02 2015, Zach, DailyProgress, SiFi - ringdown, Sapphire washers added, ringdown setup rebuilt, higher Q measured ringdown_readout.jpgmode_ringing.jpgSi_with_saph_300K_1_15_15.pngMarie_data.png
Entry  Wed Jan 14 02:38:43 2015, Zach, Laser, SiFi, PMC set up as test cavity PMC_setup.jpgTEM00_trans.jpg
Entry  Fri Dec 19 21:37:12 2014, Zach, Laser, SiFi, Amplitude modulator characterization setup.jpgAM_DC_responses_12_19_14.pngAM_TFs_12_19_14.png
Entry  Fri Dec 19 18:02:33 2014, Chris, Lab Infrastructure, Control System, cymac model at 64K rate 
Entry  Thu Dec 18 03:39:32 2014, Zach, Laser, SiFi, free-running laser frequency noise laser_beat_noise_12_17_14.pngIQ.jpgDFD.jpg
Entry  Wed Dec 17 13:54:19 2014, Zach, Laser, SiFi, Lasers mounted, energized, beat set up diagram.jpgsetup_with_beat.jpg
    Reply  Wed Dec 17 14:40:15 2014, Dmass, Laser, SiFi, Lasers mounted, energized, beat set up 
       Reply  Wed Dec 17 18:11:38 2014, Zach, Laser, SiFi, Lasers mounted, energized, beat set up 
Entry  Mon Dec 8 16:12:28 2014, Chris, Electronics, General, Using the prologix gpib adapter 
Entry  Fri Dec 5 12:50:24 2014, Dmass, Notes, General, dBm conversion table dBm_conversion_table.png
Entry  Thu Dec 4 19:52:11 2014, nicolas, Electronics, General, Using the Zurich HF2 built in PLL 45.pngPLLCLG.pdfPLLNoise.pdf
Entry  Wed Dec 3 15:43:15 2014, Dmass, Noise Hunting, Meetings, Meeting notes 
Entry  Tue Dec 2 16:12:18 2014, Dmass, Update, Roadmap, The week's measurements 
Entry  Tue Nov 25 23:11:41 2014, Dmass, Noise Hunting, Cryo ISS, Anomalous intensity noise CavHz2RIN.png
    Reply  Tue Dec 2 16:05:06 2014, Dmass, Noise Hunting, Cryo ISS, ISS loops almost work 
Entry  Tue Nov 25 16:06:55 2014, Dmass, Things to Buy, PDH, EOM response EOM_V2RINcompare_full.pngEOM_V2RINcompare_zoom.png
Entry  Thu Oct 30 23:22:14 2014, Dmass, Noise Hunting, Noise Budget, Current Driver Noise Measured WestCurrentNoise.png
    Reply  Fri Oct 31 01:03:25 2014, Dmass, Noise Hunting, Noise Budget, East loop locked with new gain distribution LB1005PDHOLTF.pngLB1005inputNoise.png
       Reply  Fri Oct 31 16:12:18 2014, Dmass, Noise Hunting, Noise Budget, Err signal noise too high 
Entry  Mon Oct 27 14:00:56 2014, Chris, Electronics, General, TTFSS checked out, and shelved for now getTTFSS.mparamTTFSScryo.m
    Reply  Tue Oct 28 15:26:24 2014, Dmass, Electronics, General, TTFSS summary 
       Reply  Thu Oct 30 14:31:14 2014, Dmass, Electronics, General, LB1005 noise 
Entry  Wed Oct 29 03:44:21 2014, Dmass, Electronics, Schematics, Current Driver Mod LD_Driver.pdf
Entry  Thu Jul 17 22:21:56 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 PDH_servo.pdf
    Reply  Sun Jul 20 16:09:25 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 ELB1005data.pdfELB1005OLTFs.pdfE_plant_PDH_compare.pdf
       Reply  Mon Jul 21 19:50:28 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 LPF_Swap_Plant_OLTF.pdfLPF_Swap_LPF_TF.pdf
          Reply  Tue Jul 22 20:33:38 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 
    Reply  Sun Jul 20 20:23:38 2014, Evan, Electronics, PDH, PDHv2 upgrade mark 1 cryo002.pdf
       Reply  Fri Jul 25 18:13:18 2014, Chris, Electronics, PDH, PDHv2 upgrade mark 1 sch.jpg
          Reply  Mon Jul 28 14:37:28 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 
             Reply  Mon Oct 6 20:40:25 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 
                Reply  Tue Oct 14 21:38:51 2014, Dmass, Electronics, PDH, PDHv2 upgrade mark 1 
                   Reply  Wed Oct 15 23:05:30 2014, Dmass, Electronics, PDH, Actuation Range Needed EastTransients.png
                      Reply  Thu Oct 16 00:44:25 2014, Dmass, Electronics, PDH, Actuation Range Needed 
                         Reply  Fri Oct 17 19:15:35 2014, Dmass, Electronics, PDH, Actuation Range Semisolved PDHoutput_attenuator.png
                            Reply  Wed Oct 22 20:32:27 2014, Dmass, Electronics, PDH, Gold PD Sensing Noise EastSensingNoise.png
Entry  Tue Jun 10 18:19:49 2014, Dmass, Cryostat, Schematics, Cryostat Windows WindowDiagram.pdfCryoWindowsInPlace.png
    Reply  Tue Aug 19 13:59:13 2014, rana, Cryostat, Schematics, Cryostat Windows 
       Reply  Mon Oct 20 20:16:17 2014, rana, Cryostat, Schematics, Cryostat Windows CryoStat-WindowPattern.pdf
Entry  Tue Oct 7 19:34:51 2014, rana, Electronics, Schematics, Oscillator Box concept for making PDH LO and RF 
Entry  Mon Sep 22 19:27:25 2014, Dmass, Update, Suspension, Sus update 6x
    Reply  Tue Sep 23 02:39:52 2014, Dmass, Update, Suspension, Sus update - cavity body mode DrumModeonPEEK.png
       Reply  Tue Sep 30 04:58:32 2014, Dmass, Update, Suspension, New Suspension Investigation 6x
          Reply  Tue Sep 30 12:15:03 2014, Dmass, Update, Suspension, New Suspension Investigation 
          Reply  Wed Oct 1 02:53:44 2014, rana, Update, Suspension, New Suspension Investigation 
Entry  Thu Aug 7 13:19:05 2014, Dmass, DailyProgress, Lab Work, Overdue Elogs 
    Reply  Thu Aug 7 14:01:38 2014, Dmass, DailyProgress, Lab Work, Laser current sidebands 0807141425.jpgfmodramplot.png
       Reply  Tue Aug 19 11:10:48 2014, Dmass, DailyProgress, Lab Work, Laser current sidebands 
Entry  Mon Aug 18 13:10:45 2014, Chris, Electronics, Plots, TTFSS HV board TF IMG_20140815_191728.jpg
Entry  Wed Jul 30 20:07:36 2014, Chris, Computing, Control System, autoburt for cymac 
Entry  Wed Jul 30 16:51:56 2014, nicolas, Computing, Control System, How to set up a workstation to go with your cymac ligoapps-user-env.sh
Entry  Tue Jul 8 11:03:28 2014, Dmass, Summary, Project Schedule, Cryo Meeting / Future Work 
    Reply  Tue Jul 15 11:15:50 2014, Evan, Summary, Project Schedule, Cryo Meeting 
Entry  Thu Apr 24 11:55:51 2014, Evan, DailyProgress, PDH, Refl PD transfer functions 9x
    Reply  Wed Apr 30 09:08:33 2014, Dmass, DailyProgress, PDH, Refl PD transfer functions 
    Reply  Tue May 6 11:40:19 2014, Evan, DailyProgress, PDH, Updated noise budget cryonb_20140506.pdfcryonb_20140506.figpdhbudget.pdf
    Reply  Tue Jul 15 08:36:30 2014, Evan, DailyProgress, PDH, Refl PD transfer functions westAudTF.pdfeastAudTF.pdf
Entry  Mon Jun 30 16:35:58 2014, Evan, DailyProgress, PDH, Loops lock with on-board rf electronics 
    Reply  Thu Jul 3 17:05:46 2014, Dmass, DailyProgress, PDH, PDHv2 transfer functions PDHv2_TFs_all.pdf
       Reply  Fri Jul 4 15:01:00 2014, Evan, DailyProgress, PDH, LTSpice simulation of CRYO-001 TFs cryo001tfs.pdfcryo001spice.zip
          Reply  Sun Jul 6 22:25:30 2014, Dmass, DailyProgress, PDH, Comparison of PDH box with spice model CRYO-001_compare.pdf
             Reply  Sun Jul 6 22:37:52 2014, Evan, DailyProgress, PDH, Comparison of PDH box with spice model cryo001tfs.pdfcryo001spice_50.zip
                Reply  Mon Jul 7 06:52:34 2014, Evan, DailyProgress, PDH, Comparison of PDH box with spice model cryo002tfs.pdfcryo002spice_50.zip
Entry  Fri Jun 20 01:05:14 2014, Dmass, Laser, Transfer Functions, Measurements 
    Reply  Tue Jun 24 19:39:04 2014, Evan, Electronics, PDH, 10 Hz oscillations 
       Reply  Wed Jul 2 20:52:14 2014, Dmass, Electronics, PDH, 10 Hz oscillations 
          Reply  Thu Jul 3 16:01:30 2014, Dmass, Electronics, PDH, 10 Hz oscillations - see NIM crate 
             Reply  Sun Jul 6 22:49:07 2014, Dmass, Electronics, PDH, PDHv2 noise measurements PDHv2_EWNoise.pdfEW10HzvsRemoval.pdf
Entry  Wed Jul 2 13:22:13 2014, Dmass, Electronics, PDH, PDH phase budget - time delay 
    Reply  Wed Jul 2 20:35:34 2014, Dmass, Electronics, PDH, PDH phase budget - mixer chain PDHv2_MixerChain.png
Entry  Mon Jun 9 23:55:19 2014, Dmass, Things to Buy, Cavity, New Cavity Standoffs cavity_assembly_1.jpgCavitySupport.png
    Reply  Tue Jun 24 12:00:35 2014, Dmass, Things to Buy, Cavity, New Cavity Standoffs 
Entry  Tue Jun 24 05:09:35 2014, Zach, Cryostat, SiFi, Cavity construction ideas symmetric_screenshot.pngmacromirror_screenshot.pngSiFi_Assembly_symmetric.easmSiFi_Assembly_macromirror.easm
Entry  Mon Jun 23 23:49:49 2014, Zach, Laser, SiFi, Cavity axis angle shift vs g-factor cavity_axis_shift_vs_gfactor.pdf
Entry  Mon Jun 9 13:03:01 2014, Dmass, Noise Hunting, Noise Budget, Silicon Carrier Density Noise 
    Reply  Mon Jun 9 19:51:42 2014, nicolas, Noise Hunting, Noise Budget, Silicon Carrier Density Noise 
    Reply  Wed Jun 18 17:15:57 2014, Evan, Noise Hunting, Noise Budget, Silicon carrier density noise cryo_cd_noise.pdfcryo_cd_noise.zip
Entry  Tue Jun 10 12:22:25 2014, Dmass, Noise Hunting, Noise Budget, Updated Noise Budget NoiseBudget.pdfNoiseBudget.figBeatNoiseEvo.pdf
Entry  Wed May 7 17:52:45 2014, Evan, Electronics, PDH, To adjust the PDHv2 input gains ad829_components.png
    Reply  Thu May 8 11:46:44 2014, Evan, Electronics, PDH, LISO estimates of noise cryo001tfLiso.pdfcryo001noiseLiso.pdf
       Reply  Thu May 8 15:41:55 2014, Dmass, Electronics, PDH, West PDH loop fixed, new UGF~200kHz PDH_OLTFs_May5_14.pdfcryo001.pdf
    Reply  Wed May 28 16:21:09 2014, Evan, Electronics, PDH, PDHv2 input gains now 20; output impedance 50 ohms 
Entry  Thu Dec 5 18:25:30 2013, Evan, Electronics, PDH, On-board PDH demodulation implemented on CRYO–002 cryo002_lochain.pdf
    Reply  Thu May 22 15:32:26 2014, Evan, Electronics, PDH, On-board PDH demodulation implemented on CRYO–001 
Entry  Thu May 15 17:40:01 2014, Dmass, Electronics, PDH, PDH summary 
Entry  Tue May 13 18:44:16 2014, Dmass, DailyProgress, Cryo, Cooldown summary 
Entry  Fri May 9 14:20:27 2014, Evan, Electronics, Schematics, PDH gain distribution summary 2014-05-09_13.03.59.jpg
Entry  Tue May 6 17:34:41 2014, Dmass, DailyProgress, , West ColdBeatMay0614.pdf
Entry  Tue May 6 11:45:08 2014, Rana, Dmass, Evan, Notes, Meetings, Meeting notes 
Entry  Fri Apr 25 17:22:27 2014, nicolas, dmass, DailyProgress, Body Mode, Beat to ESD feedback is not enough gain 
    Reply  Fri Apr 25 18:58:54 2014, Dmass, DailyProgress, Body Mode, Body Mode Measured WBodyModeRingdown300K.pdfBodyModeRingdown.pdf
       Reply  Mon Apr 28 17:48:02 2014, Dmass, DailyProgress, Body Mode, East Mode still not found 
       Reply  Fri May 2 02:40:34 2014, Dmass, DailyProgress, Body Mode, Body Mode Measured Ringdown34909.pdf
          Reply  Sat May 3 18:16:55 2014, Dmass, DailyProgress, Body Mode, Body Mode Measured ESD_TF_Raw.pdfESD_TransFun.pdf
             Reply  Sat May 3 19:57:56 2014, Dmass, DailyProgress, Body Mode, Body Mode Response Seen in RIN Transfer Function RINtoLength_TF_Raw.pdfRINtoLength_TF.pdf
             Reply  Mon May 5 17:09:06 2014, nicolas, DailyProgress, Body Mode, Body Mode Measured 
Entry  Thu May 1 00:41:19 2014, Dmass, Cryostat, Cryo, Cooldown Run Summary 
Entry  Tue Apr 29 20:38:45 2014, Dmass, Cryostat, Lab Work, Cryostat Filled - Cooling 
    Reply  Wed Apr 30 02:53:56 2014, Dmass, Cryostat, Lab Work, Cryostat Filled - Cooling 
       Reply  Wed Apr 30 08:38:32 2014, Evan, Cryostat, Lab Work, Cryostat Filled - Cooling 
       Reply  Wed Apr 30 15:40:25 2014, Dmass, Cryostat, Lab Work, East Cavity Aligned Cold 
Entry  Fri Apr 25 15:40:33 2014, nicolas, Computing, General, New Firewall/Router 
Entry  Sun Apr 13 02:31:52 2014, Dmass, DailyProgress, Lab Work, Progress RackUpgrade.pdf0408141609.jpgCryoESD.pdf
    Reply  Tue Apr 15 22:12:39 2014, Dmass, DailyProgress, Lab Work, Progress 
       Reply  Wed Apr 16 16:38:14 2014, Dmass, DailyProgress, Lab Work, Progress: aligned and pumping down 
          Reply  Thu Apr 17 16:32:37 2014, Dmass, DailyProgress, Lab Work, Cryo beat prep 
             Reply  Tue Apr 22 13:56:08 2014, steve, DailyProgress, Lab Work, green glass dumps 
Entry  Wed Apr 9 16:25:55 2014, nicolas, evan, Electronics, Transfer Functions, Surprise! Zero pole filter found in diode drivers Graph1.pngGraph2.png
    Reply  Thu Apr 10 12:47:47 2014, nicolas, Electronics, Transfer Functions, Surprise! Driver + laser TFs are completely flat! Graph1.pngGraph2.pngGraph1.pngGraph2.pngplloltf.pdf
    Reply  Fri Apr 11 13:47:27 2014, Dmass, Electronics, Transfer Functions, Surprise! Zero pole filter found in diode drivers DiodeandDriver.pdf
       Reply  Mon Apr 14 11:41:49 2014, nicolas, Electronics, Transfer Functions, No zero-pole filter in diode drivers Graph1.pngGraph2.pngGraph1.pngGraph2.png
Entry  Mon Apr 7 15:08:32 2014, nicolas, Computing, General, gaston internet fixed 
Entry  Tue Apr 1 15:34:38 2014, Charles, Summary, Cryo ISS, Cryo ISS: Design and Characterization 8x
    Reply  Tue Apr 1 17:28:13 2014, Evan, Summary, Cryo ISS, Cryo ISS: Design and Characterization 
       Reply  Thu Apr 3 16:24:00 2014, Charles, Summary, Cryo ISS, Cryo ISS: Design and Characterization cryo_iss_tf_real_vs_meas.pngcryo_iss_tf_real_vs_meas_(closed_loop).pngcryo_iss_tf.png
Entry  Wed Mar 19 18:39:04 2014, Evan, Dmass, Electronics, Lab Work, OLTF and RIN coupling of PLL cryopll_oltf.pdfcryopll_rincpl.pdfcryopll_oltf_rincpl.zip
    Reply  Thu Mar 20 00:58:39 2014, Dmass, Electronics, Lab Work, OLTF and RIN coupling of PLL PLL_RIN_Coup_dB.pdfPLL_RIN_Coup_TFs.pdfPLL_RIN_Coupling.pdf
       Reply  Fri Mar 21 16:30:47 2014, Dmass, Electronics, Lab Work, OLTF and RIN coupling of PLL PLL_fnoise.pdf
Entry  Fri Jan 3 15:08:07 2014, Dmass, Noise Hunting, Noise Budget, RIN currently limiting beat - investigation! PDH_input_ref_noise.pdfoffsetHz2RIN.pdfoffset_RIN_compare.pdfBeat_noise_RIN.pdf
    Reply  Tue Jan 7 13:20:17 2014, rana, Noise Hunting, Noise Budget, RIN currently limiting beat - investigation! 
       Reply  Thu Jan 16 00:55:04 2014, Dmass, Noise Hunting, Noise Budget, RIN currently limiting beat - investigation! 9x
    Reply  Wed Feb 12 01:59:54 2014, Dmass, Noise Hunting, Noise Budget, RIN currently limiting beat - investigation! 
       Reply  Wed Feb 12 23:56:18 2014, Dmass, Noise Hunting, Noise Budget, ISS mark 1 ISS_mark_I.pdf
          Reply  Fri Feb 14 17:05:15 2014, Dmass, Noise Hunting, Noise Budget, ISS mark 1 WestISSLoop.pngDriverAOMPDMeasData.pdfDriverAOMPD_TF.pdf
             Reply  Tue Feb 18 16:03:00 2014, Dmass, Noise Hunting, Noise Budget, AOM Misaligned? 
             Reply  Wed Mar 12 12:46:18 2014, Dmass, Noise Hunting, Noise Budget, West Finesse and Cavity Pole Measured Meas_Setup.pngDriveSweep.pngWestCavPoleFit.pdfWestPoleMeasCompare.pdf
                Reply  Thu Mar 13 02:37:30 2014, Dmass, Noise Hunting, Noise Budget, West Finesse and Cavity Pole Measured MeasSetup.pngScopePic.pngWCavRingDownLog.pdf
                Reply  Tue Mar 18 02:43:36 2014, Dmass, Noise Hunting, Noise Budget, West Finesse and Cavity Pole Measured EastCavPoleErr.pdfEastCavPole.pdfWestCavPole.pdf
Entry  Fri Mar 14 11:28:42 2014, nicolas, Summary, Control System, Narrow band resonant feedback servos 
Entry  Tue Mar 11 01:19:21 2014, Dmass, Noise Hunting, Lab Work, East sidebands are small PDH_state_3_10_14.pngWest_SB_scans.jpg
    Reply  Tue Mar 11 16:46:18 2014, Dmass, Noise Hunting, Lab Work, East sidebands are small  PMModDepth.pdfBesselExpansion.pdfBesselExpansion.pdf
    Reply  Tue Mar 11 16:46:18 2014, Dmass, Noise Hunting, Lab Work, East sidebands are small  PMModDepth.pdfBesselExpansion.pdf
Entry  Sat Mar 8 16:03:45 2014, Dmass, DailyProgress, , Beam jitter to modematching unlikely MisalignmentMeas.pdf
    Reply  Mon Mar 10 21:14:05 2014, Zach, DailyProgress, stuff happens, Beam jitter to modematching unlikely (re: PDH2) 
Entry  Wed Feb 19 19:44:55 2014, Dmass, Notes, Roadmap, Pizza Meeting Notes 0218141301.jpg
    Reply  Wed Feb 26 01:49:50 2014, Dmass, Notes, Roadmap, Best anamalous RIN candidate 
       Reply  Fri Feb 28 00:17:00 2014, Dmass, Notes, Roadmap, Best anamalous RIN candidate RINdispjitterWest.pdf
          Reply  Sat Mar 1 16:06:46 2014, Dmass, Notes, Roadmap, Best anamalous RIN candidate Erf_from_occlusion.pdf
             Reply  Sun Mar 2 18:03:58 2014, Dmass, Notes, Roadmap, Jitter to RIN coupling estimat 
                Reply  Mon Mar 3 14:33:14 2014, Dmass, Notes, Roadmap, Jitter to RIN coupling estimate cont'd 
Entry  Mon Mar 3 00:20:24 2014, Zach, Electronics, Control System, Testing microBIO with digital system MBIO_model2.png
Entry  Thu Feb 27 03:34:58 2014, Zach, Electronics, Control System, microBIO microBIO.pngmicroBIO.pdf
Entry  Tue Feb 25 23:52:18 2014, Zach, Electronics, General, MAX333 is quiet 20140225_214609.jpg20140225_234647.jpgMAX333_noise_2_25_14.png
Entry  Fri Feb 21 04:09:48 2014, Zach, Electronics, Sensors, omniPD omniPD.pdf
    Reply  Fri Feb 21 12:55:15 2014, nicolas, Electronics, Sensors, omniPD 
       Reply  Fri Feb 21 13:47:36 2014, Zach, Electronics, Sensors, omniPD omniPD.pdf
    Reply  Tue Feb 25 10:26:33 2014, rana, Electronics, Sensors, omniPD 
       Reply  Tue Feb 25 17:03:01 2014, Zach, Electronics, Sensors, omniPD 
Entry  Fri Jan 31 15:12:24 2014, Dmass, Notes, Schematics, Nice cavity schematic Si_SpacerDrawing.png
    Reply  Mon Feb 10 14:04:20 2014, Dmass, Notes, Schematics, Nice cavity schematic 
    Reply  Mon Feb 17 15:06:56 2014, Dmass, Notes, Schematics, Nice experimental schematic CryoDiagSimple.pdf
       Reply  Thu Feb 20 17:17:32 2014, Dmass, Notes, Schematics, Gold PD love 
          Reply  Fri Feb 21 13:09:31 2014, Dmass, Notes, Schematics, Moving RAM/RIN PDs, cont'd 
             Reply  Sat Feb 22 16:28:52 2014, Dmass, Notes, Schematics, Moving RAM/RIN PDs, cont'd RAMandRINPDswap.pdf
Entry  Thu Feb 20 18:53:54 2014, nicolas, Electronics, AOM, AOM Driver Response 6x
Entry  Thu Dec 5 18:20:14 2013, nicolas, Noise Hunting, Noise Budget, DFD noise in NB beat_budget.pdfelec_budget.pdf
    Reply  Fri Dec 6 12:50:16 2013, Dmass, Noise Hunting, Noise Budget, Is this correct? 
       Reply  Fri Dec 6 13:34:57 2013, nicolas, Noise Hunting, Noise Budget, Is this correct? 
    Reply  Sun Dec 8 12:23:39 2013, Evan, Electronics, Purchases, Suggestions for DFD upgrade 
       Reply  Sat Jan 11 12:22:44 2014, Evan, Electronics, DFD, DFD upgrade new_dfd.jpg
          Reply  Tue Jan 14 17:20:34 2014, Evan, Electronics, DFD, DFD upgrade dfd_dc_output.pdfdfd_am_response.pdf
             Reply  Wed Jan 15 12:10:27 2014, Dmass, Electronics, DFD, DFD upgrade 
             Reply  Tue Jan 21 10:34:15 2014, Evan, Electronics, DFD, DFD upgrade dfd_dc_output.pdfdfd_am_response.pdf
                Reply  Wed Jan 22 17:16:00 2014, rana, Electronics, DFD, DFD upgrade 
                Reply  Fri Jan 31 12:29:44 2014, Evan, Summary, DFD, DFD upgrade: diagram dfd_upgrade.pdf
Entry  Wed Jan 29 01:58:37 2014, Dmass, DailyProgress, Cavity, Cavity body mode hunt 
    Reply  Wed Jan 29 14:06:05 2014, nicolas, DailyProgress, Cavity, Cavity body mode hunt simulation bodymodeTF.pdf
Entry  Fri Jan 24 02:50:41 2014, Dmass, DailyProgress, Lab Work, AOM installed, cavity pole measurement 0123141908.jpg0123141857b.jpg0123141857a.jpg
    Reply  Tue Jan 28 11:13:12 2014, nicolas, DailyProgress, Lab Work, AOM installed, cavity pole measurement 
Entry  Tue Jan 21 15:48:28 2014, Evan, Notes, material properties, Expected cavity longitudinal mode: 35 kHz cryo_cav_long.pngcryo_cav_bend.png
    Reply  Tue Jan 21 17:37:01 2014, Dmass, Notes, material properties, Expected cavity longitudinal mode: 35 kHz 
       Reply  Wed Jan 22 11:33:37 2014, Evan, Notes, material properties, Expected cavity longitudinal mode: 35 kHz 
    Reply  Wed Jan 22 21:16:41 2014, rana, Update, COMSOL, Expected cavity longitudinal mode: 35 kHz 
       Reply  Fri Jan 24 12:46:45 2014, Evan, Update, COMSOL, Expected cavity longitudinal mode: 35 kHz cryo_cav_long_free.png
Entry  Wed Jan 22 18:44:05 2014, nicolas, Electronics, AOM, AOM RF driver has very narrow tuning range and is hysteretic AOMdriver.pdf
Entry  Wed Jan 22 18:26:54 2014, Dmass, DailyProgress, Lab Work, Hunt for Body Modes - take one 
Entry  Wed Dec 11 01:09:30 2013, Dmass, Laser, Lab Work,  
    Reply  Thu Dec 12 03:14:22 2013, Dmass, Laser, Lab Work,  RINcompareEW.pngPDHcompareEW.pngRawMeasDataE.pngRawMeasDataW.png
       Reply  Thu Dec 12 11:32:44 2013, nicolas, Laser, Lab Work,  
       Reply  Mon Dec 16 02:35:12 2013, Dmass, Laser, Lab Work, Gold PDs calibrated; AM/PM measured 
          Reply  Fri Dec 20 12:57:31 2013, Dmass, Laser, Lab Work, PDH Error signal cailbration 
Entry  Wed Dec 18 18:29:42 2013, nicholass, Electronics, Drawings, Zurich 
Entry  Wed Dec 18 18:24:36 2013, nicolas, HowTo, Transfer Functions, Zurich Instruments Blog 
Entry  Sat Mar 2 12:16:13 2013, nicolas, Noise Hunting, Noise Budget, Noise coupling in Delay-line Frequency Discriminator (DFD) 83429tgbtnl.pdf
    Reply  Wed Dec 18 10:42:06 2013, Evan, Notes, DFD, Amplitude and phase noise in a detuned DFD dfd_noise_note.pdf
Entry  Tue Dec 17 17:38:52 2013, nicolas, Lab Infrastructure, Laser, West laser doesn't have a 18kHz pole westloopfit.pdfcryo001fit.pdfwestplant.pdfwestplantnocavpole.pdf
Entry  Tue Dec 17 12:10:45 2013, Dmass, Notes, Meetings,  
Entry  Thu Dec 12 19:27:41 2013, nicolas, Electronics, Control System, West cavity open loop gain measured with zurich instruments HF2 ziControlziControl.png
    Reply  Fri Dec 13 16:38:41 2013, nicolas, Electronics, Control System, fit of west cavity open loop gain fit.pdf
Entry  Tue Dec 10 12:26:57 2013, Dmass, Noise Hunting, Noise Budget, Measurement Roadmap 
    Reply  Tue Dec 10 18:08:23 2013, Dmass, Noise Hunting, Noise Budget, Noise improvements! 
Entry  Fri Dec 6 17:23:11 2013, Dmass, DailyProgress, Lab Work, Adding RAM/RIN monitors 
    Reply  Sun Dec 8 18:48:51 2013, Dmass, DailyProgress, Lab Work, RAM/RIN monitors 
    Reply  Mon Dec 9 16:50:03 2013, Dmass, DailyProgress, Lab Work, Adding RAM/RIN monitors 
Entry  Wed Dec 4 15:47:20 2013, Evan, Update, Plots, PDH error signal dark noise added to noise budget beatbudget.pdf
    Reply  Thu Dec 5 21:28:12 2013, Dmass, Update, Plots, Changes to noisebudget NoiseBudget.pdf
       Reply  Fri Dec 6 00:56:27 2013, Dmass, Update, Plots, Addition to SimulinkNB on svn 
       Reply  Fri Dec 6 13:39:32 2013, nicolas, Update, Plots, Changes to noisebudget 
Entry  Thu Dec 5 15:05:55 2013, nicolas, dmass, Noise Hunting, Transfer Functions, DFD AM noise coupling measured diagramsvg.pdfDFDTF_MHz.pdfDFDTF_Rad.pdf
Entry  Mon Nov 25 20:23:57 2013, Dmass, Nic, Evan, DailyProgress, Cavity, New beat with both PDH2 boards beat_2013-11-25.pdf
    Reply  Tue Nov 26 02:11:15 2013, Dmass, DailyProgress, Cavity, New beat with both PDH2 boards Marc_noise_DFD.pdf
    Reply  Tue Dec 3 11:56:51 2013, Dmass, Nic, Evan, Notes, Meetings, Notes from weekly meeting 
Entry  Tue Nov 26 16:30:06 2013, Dmass, Laser, Transfer Functions, Temperature Plant Measured 
    Reply  Tue Nov 26 18:19:27 2013, nicolas, Laser, Transfer Functions, Temperature Plant Measured lasertemptfs.pnglasertemptfs.png
       Reply  Tue Dec 3 03:09:24 2013, Dmass, Laser, Transfer Functions, Temperature Plant Measured 
Entry  Tue Dec 3 02:59:07 2013, Dmass, Computing, Control System, Cross talk between Krackle and Cryo 
Entry  Wed Nov 27 12:48:20 2013, Evan, Electronics, PDH, Resistor changes in CRYO–001 and CRYO–002 
Entry  Fri Nov 15 15:07:32 2013, Evan, Electronics, PDH, PDH2 CRYO-002 measurements with fake plant rcplant.pdfpdh2_cryo002.pdfpdh2_cryo002_lfboost.pdf
    Reply  Sun Nov 24 13:19:00 2013, Evan, Electronics, PDH, PDH2 CRYO-002 noise measurements cryo002_noise_hi.pdfcryo002_tf_hi.pdf
       Reply  Mon Nov 25 10:27:42 2013, Evan, Electronics, PDH, PDH2 CRYO-001 noise measurements cryo001_noise_hi.pdfcryo001_tf_hi.pdf
    Reply  Mon Nov 25 19:51:03 2013, Evan, Electronics, PDH, PDH2 CRYO-001 measurements with fake plant modelplant.pdfcryo001_oltf_modelplant.pdfcryo001_est_tf.pdf
Entry  Fri Nov 22 18:36:15 2013, nicolas, Noise Hunting, Noise Budget, Scattered light, Suspension added to noise budget beat_budget.pdfscattering_budget.pdf
    Reply  Mon Nov 25 12:09:33 2013, Nic, Evan, Noise Hunting, Noise Budget, PDH electronic noise added to noise budget beat_budget_with_pdh.pdfpdh_budget.pdf
Entry  Fri Nov 22 17:18:38 2013, Evan, Electronics, PDH, PDH2 CRYO–001 modified 
Entry  Mon Nov 18 22:52:59 2013, Dmass, Evan, DailyProgress, Cavity, Beat spectrum with good mode-matching and with CRYO–002 beat_2013-11-18.pdfrawbeat.pdf
    Reply  Wed Nov 20 23:24:00 2013, rana, DailyProgress, Cavity, Beat spectrum with good mode-matching and with CRYO–002 
Entry  Mon Nov 18 19:17:17 2013, Dmass, Evan, DailyProgress, Optics, Mode matching: good results 
Entry  Mon Nov 11 19:43:52 2013, Evan, DailyProgress, Cavity, Beat spectrum with new suspension new_sus_beat.pdfnew_sus_beat.pdf
    Reply  Sun Nov 17 22:09:33 2013, Dmass, DailyProgress, Cavity, Beat spectrum with new suspension Nov15beat.pdf
Entry  Fri Oct 4 18:46:35 2013, Dmass, Electronics, PDH, Resonant EOM success eom_impedance.pdfeom_impedance.zip
    Reply  Mon Oct 7 16:03:30 2013, Dmass, Electronics, PDH, Resonant EOM success - details EOMres_circ.pngResEOMcircPic_zoom.png1004131458.jpgeom_impedance.pdf1003132152.jpg
       Reply  Thu Nov 14 18:24:06 2013, Dmass, Electronics, PDH, Second resonant EOM Res_EOM_circ_2.jpg
          Reply  Thu Nov 14 18:54:16 2013, Dmass, Electronics, PDH, Second resonant EOM 
Entry  Tue Nov 12 22:26:18 2013, Dmass, Noise Hunting, SUS, Trans PD mystery solved 
Entry  Mon Nov 11 21:01:14 2013, nicolas, Electronics, Control System, laser temperature loops tuned 
Entry  Sat Nov 9 20:11:54 2013, Evan, DailyProgress, Laser, Power budget for beat amplitude 
Entry  Sat Nov 9 13:39:25 2013, Evan, Electronics, General, PDH2 CRYO-002: boost 3 needs work fakeplant.pdfcryo002-tfs.pdf
Entry  Thu Nov 7 00:29:55 2013, Dmass, Cryostat, SUS, SUS update - progress 
    Reply  Thu Nov 7 19:14:52 2013, Dmass, Cryostat, SUS, SUS update - progress 
Entry  Tue Oct 29 19:01:51 2013, dmass, nicolas, DailyProgress, SUS, In air suspension Q measurement modespec.pdfringdown.pdf
    Reply  Thu Nov 7 13:16:04 2013, dmass, nicolas, DailyProgress, SUS, In air suspension Q measurement spec.pdfQ.pdf
Entry  Tue Jul 2 03:56:12 2013, Dmass, Cryostat, Cavity, New Cavity Suspension 
    Reply  Tue Jul 2 15:15:49 2013, Dmass, Cryostat, Cavity, New Cavity Suspension 
       Reply  Thu Jul 25 16:11:12 2013, Dmass, Cryostat, Cavity, New Cavity Suspension 
          Reply  Mon Aug 12 15:34:43 2013, Dmass, Cryostat, Cavity, New Cavity Suspension - springs 
             Reply  Tue Aug 13 15:54:46 2013, Dmass, Cryostat, Cavity, Spring choice cont'd 
                Reply  Tue Aug 13 17:35:37 2013, Dmass, Cryostat, Cavity, Spring choice cont'd -2 
                   Reply  Thu Aug 15 15:46:26 2013, Dmass, Cryostat, Cavity, Spring choice cont'd -2 
                Reply  Wed Oct 30 15:21:15 2013, Dmass, Cryostat, Cavity, First hitch in suspension design 
                   Reply  Mon Nov 4 12:18:28 2013, Dmass, Cryostat, Cavity, First hitch in suspension design 
Entry  Wed Oct 30 14:07:04 2013, nicolas, Electronics, Control System, PDH boost design newpdhboosts.pdfnoisewithboosts.pdf
    Reply  Wed Oct 30 18:02:50 2013, nicolas, Electronics, Control System, PDH boost design OLG.pdfCLG.pdf
Entry  Tue Oct 29 20:15:48 2013, Evan, Electronics, General, PDH2 CRYO–002 boost modification 
Entry  Tue Oct 1 15:02:55 2013, Dmass, Update, Lab Work, To Do: 
    Reply  Tue Oct 1 18:09:38 2013, Dmass, Update, Lab Work, To Do: Gold PDs 
       Reply  Fri Oct 25 17:21:23 2013, Dmass, Update, Lab Work, To Do: Gold PDs 
          Reply  Mon Oct 28 21:22:33 2013, Dmass, Update, Lab Work, To Do: Gold PDs 
Entry  Mon Jun 24 16:15:08 2013, nicolas, Computing, General, ssh into gaston 
    Reply  Mon Oct 28 09:45:25 2013, Evan, Computing, General, ssh into gaston 
Entry  Fri Oct 18 14:04:23 2013, Dmass, Cryostat, SUS, Suspension work: spring constant + resonant frequencies spring_const.pdf
    Reply  Fri Oct 18 21:48:28 2013, Dmass, Cryostat, SUS, Suspension work Spring_Q_measurement.png
       Reply  Mon Oct 21 14:02:23 2013, rana, Cryostat, SUS, Suspension work 
          Reply  Tue Oct 22 00:20:51 2013, Dmass, Cryostat, SUS, Suspension work 
             Reply  Tue Oct 22 21:08:51 2013, Dmass, Cryostat, SUS, de-Q the springs! SpringdeQing.png
                Reply  Tue Oct 22 23:41:39 2013, Dmass, Cryostat, SUS, More SUS Clean_SUS_Springs.png
                   Reply  Fri Oct 25 16:19:57 2013, rana, Cryostat, SUS, More SUS 
Entry  Mon Apr 1 19:14:06 2013, jamie, Computing, DAQ, daqd timing mismatch seems to be a transient phenomenon 
    Reply  Tue Apr 2 14:15:37 2013, Dmass, Computing, DAQ, CyMAC installation 
       Reply  Tue Oct 22 21:48:56 2013, Dmass, Computing, DAQ, X1CRY model rate changed 
Entry  Mon Oct 21 02:19:19 2013, Dmass, DailyProgress, SUS, Suspension work 
    Reply  Mon Oct 21 22:47:37 2013, Dmass, DailyProgress, SUS, Suspension work update 
Entry  Sat Oct 12 22:25:34 2013, Evan, DailyProgress, Noise Budget, DC-dependent beat noise DFD_beat_output.pdf
    Reply  Tue Oct 15 00:13:59 2013, rana, DailyProgress, Noise Budget, DC-dependent beat noise 
       Reply  Wed Oct 16 12:09:02 2013, Dmass, DailyProgress, Noise Budget, DC-dependent beat noise 
Entry  Mon Oct 14 22:05:41 2013, Evan, DailyProgress, Lab Work, Buzzing; beat kick beatkick_2013-10-14.pdf
Entry  Fri Oct 11 00:54:18 2013, Dmass, DailyProgress, Lab Work, PDH hiatus; buzz + suspension progress 
    Reply  Mon Oct 14 04:24:25 2013, Dmass, DailyProgress, Lab Work, Last week's progress 
Entry  Fri Oct 11 17:03:17 2013, nicolas, Computing, General, gpsnow script on gaston outputs current gps time 
Entry  Fri Oct 4 19:22:50 2013, nicolas, evan, Electronics, Control System, lead filter will increase our pdh bandwidth 6x
    Reply  Sun Oct 6 22:24:30 2013, Evan, Electronics, Control System, LTSpice modeling of proposed PDH2 modifications proposed_oltf.pdfmodcryo.pdf
       Reply  Mon Oct 7 21:18:02 2013, Evan, Electronics, Control System, Promising results from CRYO-002 modifications pdh2_tfs.pdfeastcav_oltfs.pdfcryo-002_mods.zip
          Reply  Thu Oct 10 04:34:12 2013, Dmass, Electronics, Control System, Promising results from CRYO-002 modifications 1009131534a.jpg
Entry  Wed Oct 9 23:32:39 2013, dmass, Lab Infrastructure, Lab Work, Lab Now Cleaner! 1008131855c.jpg
Entry  Wed Oct 9 17:44:10 2013, nicolas, dmass, Lab Infrastructure, Sensors, Particle counter is running and being recorded by cymac 
Entry  Mon Sep 30 23:34:50 2013, Dmass, Noise Hunting, Noise Budget, Buzz prep + progress 2013-09-30_buzzing.pngbuzzing_plots.pdf
    Reply  Fri Oct 4 12:13:36 2013, nicolas, Noise Hunting, Noise Budget, Buzz prep + progress 
       Reply  Fri Oct 4 15:40:14 2013, Evan, Noise Hunting, Noise Budget, Buzz prep + progress 
          Reply  Fri Oct 4 15:59:21 2013, not Evan, Noise Hunting, Noise Budget, Buzz prep + progress 
Entry  Wed Oct 2 01:04:53 2013, Evan, DailyProgress, Laser, Estimate of east PDH plant transfer function tot_tf.pdfboard_zpk_fit.pdfplant_est.zipplant_tf.pdfOLTFMeasDiag.png
    Reply  Wed Oct 2 17:09:57 2013, Dmass, DailyProgress, Laser, Estimate of east PDH plant transfer function 
Entry  Tue Oct 1 17:51:26 2013, nicolas, Laser, Control System, Laser response according to RIO paper 
    Reply  Tue Oct 1 17:54:01 2013, Dmass, Laser, Control System, Laser response according to RIO paper 
Entry  Mon Sep 30 18:04:13 2013, Dmass, Computing, Control System, Control signals for lasers calibrated 
Entry  Fri Sep 27 13:31:42 2013, Dmass, Computing, DAQ, Well intentioned transmission-triggered auto locker causes pain 
    Reply  Sat Sep 28 13:53:17 2013, nicolas, Computing, DAQ, Well intentioned transmission-triggered auto locker causes pain 
       Reply  Mon Sep 30 11:57:18 2013, nicolas, Computing, DAQ, monkeys monkeys1.pdf
Entry  Mon Sep 30 11:43:43 2013, Evan, DailyProgress, Sensors, Beat power budget beat_amp_gain.pdf
Entry  Fri Sep 27 22:29:06 2013, Evan, DailyProgress, Cavity, Warm, in-vacuum beat measurement cryo_beat.pdfdelay_line_slope.pdfcryo_beat_data.zip
Entry  Thu Sep 26 01:22:03 2013, Dmass, Summary, Drawings, Mechanical Drawings + Designs 
    Reply  Thu Sep 26 16:44:15 2013, Dmass, Summary, Drawings, Birth of a Timeline 
    Reply  Fri Sep 27 15:27:41 2013, Dmass, Summary, Drawings, Mechanical Drawings + Designs update_1 
Entry  Fri Sep 27 14:51:53 2013, Evan, Electronics, General, Delay line calibration cryo_delay.pdfcryo_delay.zip
Entry  Thu Sep 26 18:43:20 2013, Evan, DailyProgress, Lab Work, Prep for buzzing 
Entry  Thu Sep 26 10:23:02 2013, Evan, Electronics, Transfer Functions, New transfer functions of PDH2 CRYO-001 tf_inv_up_spice.pdf
Entry  Sun Feb 3 21:39:20 2013, Dmass, Computing, Simulation, Spice on MAC 
    Reply  Tue Feb 5 00:19:31 2013, Dmass, Computing, Simulation, LISO 
       Reply  Tue Feb 5 15:26:49 2013, Dmass, DailyProgress, Lab Work, Weekly meeting! 
    Reply  Wed Sep 25 22:57:24 2013, Evan, Computing, Simulation, Spice on MAC ltspice_osx_screenshot.jpg
Entry  Tue Sep 24 16:26:34 2013, Rich Abbott, Electronics, General, Impedance matching to EOM September.pdf
    Reply  Wed Sep 25 03:15:56 2013, Dmass, Electronics, General, Impedance matching to EOM 
Entry  Fri Sep 20 21:25:11 2013, Evan, Electronics, General, PDH2 input oscillation 
    Reply  Mon Sep 23 18:12:33 2013, Evan, Electronics, General, PDH2 input oscillation; SVG schematic of CRYO-001 
Entry  Sat Sep 21 15:44:04 2013, Evan, Notes, Cleanliness, Particulate counts in cryo vs. PSL cryo_desk.pdfpsl_desk.pdfparticle_counter_data.zip
Entry  Thu Sep 19 16:08:08 2013, Warren Johnson, Cryostat, , sketch of future cryostat cryostat_9_18_13.jpg
Entry  Mon Sep 16 16:51:58 2013, Dmass, DailyProgress, Lab Work,  
    Reply  Tue Sep 17 16:12:42 2013, Dmass, DailyProgress, Lab Work, EOM buzzing progress 
Entry  Tue Sep 17 00:50:23 2013, Evan, DailyProgress, Cavity, Pumpdown; robustness of alignment against torquing 
Entry  Thu Sep 12 15:21:49 2013, nicolas, Noise Hunting, Noise Budget, Added intensity noise coupling through photothermal absorption current_NB.pdf
Entry  Tue Sep 10 11:13:25 2013, nicolas, Noise Hunting, Sensors, Accelerometers are on the CryoCav table 
    Reply  Tue Sep 10 13:51:57 2013, Dmass, Noise Hunting, Sensors, Accelerometers are on the CryoCav table 
    Reply  Thu Sep 12 00:27:41 2013, rana, Noise Hunting, DAQ, LIGOdv for viewing CYMAC data ligodv.pngligodvacc.png
Entry  Tue Sep 10 15:50:26 2013, nicolas, Noise Hunting, Noise Budget, Better seismic noise estimate currentNB.pdf
Entry  Thu Sep 5 15:49:11 2013, Dmass, DailyProgress, General, Weekly Update 
    Reply  Sat Sep 7 21:49:02 2013, Dmass, DailyProgress, General, Weekly Update 
       Reply  Mon Sep 9 23:33:45 2013, Dmass, DailyProgress, General, Weekly Update 
Entry  Mon Sep 9 15:45:17 2013, nicolas, Noise Hunting, Noise Budget, Naiive seismic noise propagation basically predicts current noise level current_NB.pdf
    Reply  Mon Sep 9 17:06:13 2013, nicolas, Noise Hunting, Noise Budget, Naiive seismic noise propagation basically predicts current noise level current_NB.pdf
Entry  Tue Aug 20 19:56:12 2013, Evan, Electronics, General, Second PDH2 board: transfer function tfuncs.pdftfunc_data.zip
    Reply  Wed Aug 28 14:56:03 2013, Evan, Electronics, General, Second PDH2 board: transfer function cryo-002_tf.pdfcryo-002_tf_code.zip
       Reply  Wed Aug 28 18:37:09 2013, Evan, Electronics, General, Making the invert switch behave cryo-002_tf_inv.pdfcryo-002_tf_inv_quot.pdfcryo-002_tf_inv_code.zip
          Reply  Thu Aug 29 12:43:49 2013, Evan, Electronics, General, Making the invert switch behave cryo-002_tf_inv.pdfcryo-002_tf_inv_quot.pdfcryo-002_tf_inv_mod.zip
             Reply  Sun Sep 8 17:24:44 2013, Evan, Electronics, General, Transfer function of CRYO-002: measurements and LISO cryo-002_tf_inv.pdfcryo-002_tf_noinv.pdfcryo-002_liso.zip
Entry  Sun Sep 8 14:37:20 2013, Evan, Computing, General, A mostly painless way to put LaTeX into elog posts my_elog_post.zip
Entry  Fri Sep 6 12:26:27 2013, Evan, Electronics, Cryo, CRYO-002 PDH2 offsets; LISO model 
Entry  Fri Sep 6 11:30:41 2013, nicolas, Noise Hunting, Noise Budget, SimulinkNB based noisebudget cryocavNB.png
Entry  Wed Aug 28 16:45:59 2013, Dmass, Notes, General, Food for thought 
Entry  Tue Aug 27 16:07:09 2013, nicolas, dmass, Notes, Lab Work, todo list 
Entry  Tue Aug 27 11:47:55 2013, nicolas, Misc, Cavity, Power loss due to absorption in air 
Entry  Mon Aug 26 17:09:33 2013, nicolas, evan, DailyProgress, Cavity, Current cavity throughputs 
    Reply  Tue Aug 27 08:42:16 2013, Evan, DailyProgress, Cavity, Cavity power budget cryo_power_budget.zip
Entry  Fri Aug 16 15:05:41 2013, Dmass, Noise Hunting, Noise Budget, State of the Noise 
    Reply  Tue Aug 20 04:03:42 2013, Dmass, Noise Hunting, Noise Budget, RF AM/PM ratio measured, HUGE. 
       Reply  Wed Aug 21 13:39:25 2013, Dmass, Noise Hunting, Noise Budget, Reducing RAM 
          Reply  Mon Aug 26 23:33:43 2013, Dmass, Noise Hunting, Noise Budget, Reducing RAM 
    Reply  Tue Aug 20 18:34:23 2013, Dmass, Noise Hunting, Noise Budget, Vertical Noise Coupling 
Entry  Mon Aug 26 16:22:40 2013, nicolas, Computing, General, sshfs problems and solution 
Entry  Wed Aug 14 16:30:21 2013, Jonathan Mishler, Computing, , Frequency Comb Beating  FrequencyCombBeating.zip
Entry  Fri Aug 9 15:50:27 2013, Evan, Laser, Cavity, Cavity skewness relative to outer rad shields crop_east_back_1_annot.jpgskew_code.zip
    Reply  Tue Aug 13 14:24:11 2013, Evan, Laser, Cavity, Cavity skewness and spot locations on windows dewar_and_cavity_stripped_skewed.jpgwindowSpots_code.zip
Entry  Mon Aug 12 16:48:32 2013, Jonathan Mishler, Computing, , Frequency Comb "Heat Plot" FreBeat.m
Entry  Thu Aug 8 17:52:30 2013, Dmass, Laser, Lab Work, Cavity scans + mode matching 
Entry  Wed Aug 7 11:06:48 2013, Jonathan Mishler, DailyProgress, , Overcoming a bandwidth limited frequency comb Screen_Shot_2013-08-06_at_3.17.47_PM.pngMicroresonatorSize.xlsx
    Reply  Thu Aug 8 14:09:33 2013, Dmass, DailyProgress, , Overcoming a bandwidth limited frequency comb 
Entry  Thu Aug 1 15:45:51 2013, Jonathan Mishler, DailyProgress, Schematics, Updated Schematic and Notes Screen_Shot_2013-07-31_at_2.15.04_PM.pngScreen_Shot_2013-08-01_at_3.39.46_PM.png13_notes.docxMicroresonator_Literature.zip
Entry  Wed Jul 24 13:55:34 2013, Jonathan Mishler, DailyProgress, Schematics, First go at frequency comparison schematic Screen_Shot_2013-07-24_at_1.31.33_PM.png7.19.13.docx
Entry  Thu Jul 18 16:57:58 2013, Dmass, Notes, Meetings,  
Entry  Fri Jul 12 20:01:17 2013, Steve Maloney, Nicholas Smith-Lefebvre, Laser, Cavity, Absorbance of 532 nm on cavity mirror surface ELog.docx
    Reply  Fri Jul 12 23:57:45 2013, nicolas, Laser, Cavity, Absorbance of 532 nm on cavity mirror surface (pdf) ELog.pdf
Entry  Thu Jul 11 16:46:19 2013, nicolas, steve, DailyProgress, Lab Work, Calibrated beat shift due to green laser blast Screen_Shot_2017-09-22_at_1.18.29_PM.png
Entry  Mon Jul 8 13:02:17 2013, Dmass, Laser, Transfer Functions, Laser Transfer Function laserTF1.pnglaserTF2.png
Entry  Thu Jul 4 15:22:19 2013, nicolas, Laser, Control System, Rough tuning of laser temperature offset cavtrans.png
Entry  Thu Jul 4 14:23:26 2013, nicolas, Lab Infrastructure, General, CCD Camera power supply equipment and laser pointers in blue cabinet 
Entry  Thu Jun 27 16:30:42 2013, Dmass, Noise Hunting, General, Acoustic Noise Hunting (part 1) 
    Reply  Tue Jul 2 03:39:50 2013, Dmass, Noise Hunting, General, Acoustic Noise Hunting (part 1) 
Entry  Mon Jun 17 13:22:11 2013, nicolas, Misc, Control System, Temperature response of west cavity westcav_TF.pdf
    Reply  Sat Jun 29 13:09:54 2013, nicolas, Misc, Control System, laser temperature loops tuned timeseries.pdf
Entry  Sat Jun 29 12:37:12 2013, nicolas, Computing, Control System, single line command to rebuild x1cry model 
Entry  Tue Jun 25 22:19:42 2013, rana, Electronics, Lab Work, USB Microscope: DigiMicro 2 MegaPixel Photo_on_6-25-13_at_10.17_PM.jpg
Entry  Thu Jun 20 11:32:59 2013, Dmass, Notes, Meetings, Meeting Notes 
    Reply  Tue Jun 25 15:30:14 2013, Dmass, Notes, Meetings, Meeting Notes 
Entry  Mon Jun 24 17:23:59 2013, Dmass, DailyProgress, stuff happens, Progress 
Entry  Mon Jun 24 15:46:42 2013, nicolas, Computing, DAQ, taking CyMAC off the internet 
Entry  Tue Jun 4 11:38:59 2013, nicolas, Computing, DAQ, The state of gaston 
    Reply  Thu Jun 6 15:03:41 2013, nicolas, Computing, DAQ, The state of gaston 
    Reply  Fri Jun 21 11:51:06 2013, rana, Computing, DAQ, Workstation setup wiki 
Entry  Thu Jun 20 15:41:46 2013, Steve, nicolas, d-mass, DailyProgress, Lab Work, Attempt at cavity heating with laser pointer 
Entry  Wed Jun 19 11:41:11 2013, Dmass, Noise Hunting, Noise Budget, Beat Readout Box BeatReadoutBox.png
Entry  Mon Jun 10 17:46:21 2013, nicolas, Update, Lab Work, Today's measurements in a local SVN checkout 
    Reply  Thu Jun 13 01:39:23 2013, Dmass, Update, Lab Work, Comparison of beats BeatComparisons_A.png
Entry  Sun Jun 9 03:32:37 2013, rana, Electronics, General, RFPD ready - s/n #116 
Entry  Fri Jun 7 12:55:00 2013, nicolas, Lab Infrastructure, Roadmap, automation processes 
Entry  Thu Jun 6 16:53:50 2013, nicolas, Electronics, DAQ, ADC channels for signals 
Entry  Thu Jun 6 16:44:21 2013, nicolas, dmass, DailyProgress, Control System, slow DIGITAL laser temp control laser_temp_feedbacklaser_temp_feedback.png
Entry  Tue Jun 4 03:22:56 2013, Dmass, Noise Hunting, Noise Budget, Hunting for intensity noise coupling 
    Reply  Tue Jun 4 03:30:53 2013, Dmass, Noise Hunting, Noise Budget, Hunting for intensity noise coupling EastMeasAlign.pdfEastMeasMisalign.pdfWestMeasAlign.pdfWestMeasMisalign.pdfCalibration.pdf
       Reply  Wed Jun 5 02:17:30 2013, Dmass, Noise Hunting, Noise Budget, Hunting for intensity noise coupling AllPlots.pdf
Entry  Tue Jun 4 03:22:55 2013, Dmass, Noise Hunting, Noise Budget, Hunting for intensity noise coupling 
Entry  Mon Jun 3 14:50:24 2013, nicolas, Computing, Control System, medm screens 
Entry  Thu May 30 19:35:10 2013, nicolas, Computing, DAQ, how i got dataviewer running on gaston (the workstation) 
    Reply  Sun Jun 2 11:03:41 2013, illustrator, Computing, DAQ, how i got dataviewer running on gaston (the workstation) Walt-Disney-Screencaps-Gaston-walt-disney-characters-31944510-2560-1440.jpg
Entry  Tue May 28 17:09:27 2013, rana, Computing, DAQ, NDS1 Proxy 
    Reply  Thu May 30 19:36:33 2013, nicolas, Computing, DAQ, NDS1 Proxy 
       Reply  Sat Jun 1 17:47:39 2013, rana, Computing, DAQ, NDS1 Proxy 
Entry  Wed May 8 14:48:47 2013, Dmass, DailyProgress, Lab Work, Setback 
    Reply  Thu May 9 03:46:38 2013, Dmass, DailyProgress, Lab Work, Realignment 
    Reply  Tue May 14 00:36:27 2013, Dmass, DailyProgress, Lab Work, Leak testing update 
       Reply  Tue May 14 17:58:29 2013, Dmass, DailyProgress, Lab Work, Leak testing update - attempt #2 
          Reply  Wed May 15 21:14:27 2013, Dmass, DailyProgress, Lab Work, Leak testing update - attempt #2 
             Reply  Sun May 19 04:29:42 2013, Dmass, DailyProgress, Lab Work,  LeakandCooldown.pngXGasDuringCooldown.pngCavityCoolingXgas.png
                Reply  Mon May 20 13:36:03 2013, Dmass, DailyProgress, Lab Work, Weekend Warming May18to19pressNtemp.png
                   Reply  Wed May 22 02:31:40 2013, Dmass, DailyProgress, Lab Work, Beat frequency drift CavityTau.png
                      Reply  Thu May 23 22:04:25 2013, Dmass, DailyProgress, Lab Work, Beat frequency drift CalibratedColdBeat.png
                         Reply  Fri May 24 19:11:06 2013, Dmass, DailyProgress, Lab Work, Updated noise budget with new beat - BETTER rcSi_NB2.png
                         Reply  Mon May 27 12:44:08 2013, Dmass, DailyProgress, Lab Work, Beat Frequency Measurement/Calibration BeatFreqSketch.jpgColdBeatsAll.pdfcalibration_5_23_13.pdf
Entry  Sun May 26 23:13:34 2013, Dmass, Summary, Lab Work, Summary Previous Week 
Entry  Mon May 13 19:38:35 2013, nicolas, Computing, DAQ, fb EPICS channels 
Entry  Mon May 13 19:01:25 2013, nicolas, Computing, Control System, CDS TODO 
Entry  Mon May 13 18:21:47 2013, nicolas, Computing, DAQ, EPICS env variables on cymac 
Entry  Mon May 13 18:19:25 2013, nicolas, Computing, DAQ, How to write channels to disk (for cryocav) 
Entry  Mon May 13 17:55:46 2013, Jamie, Computing, DAQ, Ubuntu 12.04 CDS workstation software "repository" 
Entry  Mon May 13 17:18:42 2013, nicolas, Computing, Control System, Getting cymac1 to record EPICS channels (including those from fb) 
Entry  Mon May 13 17:06:40 2013, nicolas, Computing, Control System, Cymac1 can see EPICS channels on fb 
Entry  Fri May 10 17:38:05 2013, nicolas, Computing, Control System, EPICS communication 
Entry  Fri May 10 17:10:58 2013, nicolas, Computing, Control System, compiling new epics on fb 
Entry  Mon May 6 19:13:56 2013, Dmass, Cryostat, Cryo, Cooling the cavities Prelim_overview.pngPrelim_zoomed.png
    Reply  Tue May 7 15:54:17 2013, Dmass, Cryostat, Cryo, Cooling the cavities 
Entry  Tue May 7 14:19:55 2013, Dmass, HowTo, Graduate, Near term direction for self 
Entry  Mon May 6 14:15:32 2013, nicolas, Notes, Cavity, rough mode matching measurement 
Entry  Thu May 2 02:41:59 2013, Dmass, DailyProgress, Cryo, Update 
    Reply  Mon May 6 11:33:20 2013, Dmass, DailyProgress, Cryo, Update 
Entry  Thu Apr 25 14:47:23 2013, Dmass, Laser, Laser, Laser Tuning Coefficients 
    Reply  Fri Apr 26 19:38:39 2013, Dmass, Laser, Laser, Laser Tuning Coefficients 
Entry  Thu Apr 25 18:52:44 2013, nicolas, Computing, Lab Work, Network configuration 
Entry  Thu Apr 25 18:39:35 2013, nicolas, Computing, stuff happens, How to ssh into the fb (vacuum gauges) 
Entry  Thu Apr 25 11:40:45 2013, dmass, DailyProgress, Lab Work, Sideband shenanigans 
Entry  Tue Feb 1 01:16:20 2011, Dmass, DailyProgress, Plots, Cavity HOM vs g-factors RefCav4inchesAll.pdfRefCav7inchesAll.pdf
    Reply  Tue Apr 23 17:07:03 2013, Dmass, DailyProgress, Plots, Cavity HOM vs g-factors 3.9inch_all.pdf
Entry  Tue Apr 23 14:59:40 2013, Dmass, Cryostat, Cavity, Summary of alignment issues 
Entry  Tue Apr 23 14:32:51 2013, Dmass, Notes, Meetings, Cryo meeting notes 
Entry  Thu Apr 4 15:05:15 2013, Dmass, HowTo, Vacuum, Detailed Action Plan 
    Reply  Thu Apr 4 22:54:41 2013, Dmass, HowTo, Vacuum, Vent info 
       Reply  Tue Apr 9 02:23:22 2013, Dmass, HowTo, Vacuum, Vent info 
          Reply  Fri Apr 12 17:05:34 2013, Dmass, HowTo, Vacuum, Vent info 
             Reply  Fri Apr 19 04:17:01 2013, Dmass, HowTo, Vacuum, Vent info 
                Reply  Mon Apr 22 03:05:50 2013, Dmass, HowTo, Vacuum, Vent info 
                   Reply  Mon Apr 22 18:50:34 2013, Dmass, HowTo, Vacuum, Vent info 
Entry  Thu Apr 11 20:39:12 2013, rana, Misc, Cavity, Optical contacting noise doc from Weiss 
Entry  Thu Apr 4 11:08:25 2013, nicolas, leonid, Electronics, Control System, slow laser temp control 
Entry  Tue Apr 2 15:19:33 2013, Dmass, HowTo, Graduate, ISS Requirement 
Entry  Thu Mar 28 14:16:04 2013, Dmass, Cryostat, Sensors, Wiring up the 2nd cavity: detailed 
    Reply  Tue Apr 2 13:53:36 2013, Dmass, Cryostat, Sensors, Wiring up the 2nd cavity: summary 
Entry  Mon Apr 1 19:07:07 2013, jamie, Computing, DAQ, how i got testpoints 
Entry  Tue Jan 29 14:06:55 2013, Dmass, Notes, Roadmap, Near Term Task List 
    Reply  Thu Jan 31 00:31:49 2013, Dmass, Notes, Roadmap, Progress 
       Reply  Fri Feb 1 00:29:07 2013, Dmass, Notes, Roadmap, Progress - TL;DR version OLTF102068.png
          Reply  Mon Feb 4 12:05:46 2013, Dmass, Notes, Roadmap, Progress - TL;DR version cavitypoleA.png
             Reply  Mon Feb 4 16:27:26 2013, Dmass, Notes, Roadmap, Progress - TL;DR version 
       Reply  Wed Feb 27 12:23:46 2013, Dmass, Notes, Roadmap, Gold PD power 0221131645.jpg
          Reply  Mon Mar 4 00:12:01 2013, rana, Notes, Roadmap, Gold PD power 
             Reply  Wed Mar 27 19:44:43 2013, Dmass, Notes, Roadmap, Gold PD power v2 0327131539a.jpg0327131528.jpg
Entry  Tue Mar 26 11:56:02 2013, Dmass, HowTo, Graduate, Two week plan: 3/26/13 
    Reply  Tue Mar 26 14:24:47 2013, Dmass, HowTo, Graduate, Ugly Flow Chart CryoPlanMindMap(1).png
    Reply  Tue Mar 26 15:12:27 2013, Dmass, HowTo, Graduate, meeting notes 
Entry  Fri Mar 15 13:11:52 2013, nicolas, Electronics, Control System, 'right' cavity open loop gain with current pdh2 box cryocavpdh.pdf
    Reply  Thu Mar 21 12:37:05 2013, rana, Electronics, Control System, 'right' cavity open loop gain with current pdh2 box 
    Reply  Fri Mar 22 07:43:10 2013, Dmass, Electronics, Control System, 'right' cavity open loop gain with current pdh2 box 
Entry  Fri Mar 15 12:19:05 2013, nicolas, Electronics, Control System, pdh2 gain control knob pdh2gainpot.pdf
    Reply  Fri Mar 15 15:46:03 2013, Zach, Electronics, Control System, pdh2 gain control knob 
Entry  Fri Mar 15 12:51:21 2013, nicolas, Electronics, Control System, pdh2 modified to have high frequency bypass path pdh2bypass.pdf
Entry  Fri Mar 15 12:12:49 2013, nicolas, Electronics, Control System, the pdh2 invert story pdh2invert.pdf
Entry  Wed Mar 6 14:26:40 2013, nicolas, Electronics, Control System, current state of pdh2 pdh2tfs.pdfpdh2noise.pdf2013-03-05_pdhmeas.tar.gz
    Reply  Wed Mar 6 20:59:29 2013, Dmass, Electronics, Control System, current state of pdh2_2 
       Reply  Fri Mar 8 02:08:03 2013, Dmass, Electronics, Control System, current state of pdh2_2 
    Reply  Tue Mar 12 13:52:02 2013, nicolas, Electronics, Control System, trying to get more bandwidth from pdh2 loopgain.pdfpdh2.pdf
       Reply  Tue Mar 12 15:57:25 2013, Zach, Electronics, Control System, trying to get more bandwidth from pdh2 
Entry  Thu Feb 28 03:19:03 2013, Dmass, Noise Hunting, Noise Budget, Noise Budget with Beat Freq rcSi_300_v2_copy.png
    Reply  Sun Mar 3 20:31:49 2013, Dmass, Noise Hunting, Noise Budget, Sunday Oddness? 
    Reply  Mon Mar 4 20:15:07 2013, Dmass, Noise Hunting, Noise Budget, Noise Budget with Beat Freq rcSi_300_v2.pdf
       Reply  Tue Mar 5 11:29:19 2013, Dmass, Noise Hunting, Noise Budget, Beat freq measurement redone - broadband rcSi_300_v2.pdf
          Reply  Tue Mar 5 15:07:37 2013, Dmass, Noise Hunting, Noise Budget, Beat freq measurement redone - broadband 
Entry  Fri Mar 1 14:48:52 2013, nicolas, Noise Hunting, Noise Budget, Shot noise, how does that work? 
Entry  Tue Feb 26 14:25:33 2013, nicolas, dmass, DailyProgress, Control System, PDH2 box gets some tender loving care 
Entry  Wed Feb 20 00:30:54 2013, Dmass, DailyProgress, Lab Work, Milestone 
    Reply  Thu Feb 21 00:30:32 2013, Dmass, DailyProgress, Lab Work, Milestone Readout.png
       Reply  Tue Feb 26 03:50:49 2013, Dmass, DailyProgress, Lab Work, Beat Freq Noisebud MarconiNZ.pngbeatVdata.pngbeat_calibNB.png
Entry  Mon Feb 25 18:50:26 2013, nicolas annalisa, DailyProgress, Optics, quarter wave plates moved/installed. 
Entry  Wed Jan 16 17:09:40 2013, nicolas, Lab Infrastructure, General, cryo lab sr785 has new crt 
    Reply  Wed Feb 20 13:37:27 2013, Dmass, Lab Infrastructure, General, New SR785 CRT sucks 
Entry  Tue Feb 19 23:00:51 2013, Dmass, Cryostat, Vacuum, Error F007 on turbo 
Entry  Wed Feb 6 00:52:41 2013, Dmass, DailyProgress, Lab Work, Setback 
    Reply  Wed Feb 6 13:01:01 2013, Dmass, DailyProgress, Lab Work, Mild Milestone 
       Reply  Tue Feb 19 14:32:04 2013, Dmass, DailyProgress, Lab Work, Beat note work 
Entry  Wed Dec 5 16:06:03 2012, Dmass, Cryostat, Lab Work, Pressure Trend 
    Reply  Tue Dec 11 03:16:17 2012, Dmass, Cryostat, Lab Work, Pressure Trend pumpdown_12_11_12.png
       Reply  Thu Dec 20 16:40:35 2012, Dmass, Cryostat, Lab Work, Pressure Trend 16days_commented.png
       Reply  Mon Jan 7 14:02:24 2013, Dmass, Cryostat, Lab Work, Pressure Trend pumpdown_35days.png
          Reply  Tue Feb 19 13:45:56 2013, Dmass, Cryostat, Lab Work, Pressure Trend pumpdown70days10m.png
Entry  Tue Dec 11 14:35:51 2012, COMSOL Simulations and stuff, Notes, COMSOL, COMSOL work fq_comparison.png
    Reply  Wed Dec 12 16:27:30 2012, COMSOL Simulations and stuff, Notes, COMSOL, COMSOL work BAW_dims.png
       Reply  Thu Dec 13 18:19:05 2012, COMSOL Simulations and stuff, Notes, COMSOL, More Quartz BVA xstal info 
          Reply  Tue Feb 5 13:37:05 2013, COMSOL Simulations and stuff, Notes, COMSOL, More Quartz BVA xstal info 
       Reply  Wed Feb 13 15:04:38 2013, Dmass, Notes, COMSOL, Misc f*Q notes from Cahill meetings 
    Reply  Wed Feb 13 14:26:18 2013, Dmass, Notes, COMSOL, Update on f*Q COMSOL project 
       Reply  Wed Feb 13 16:54:39 2013, Dmass, Notes, COMSOL, Update on f*Q COMSOL project 
Entry  Tue Feb 5 00:02:25 2013, Dmass, Laser, Laser, DIrect FM modulation sidebands imodsidebands.png
Entry  Mon Jan 7 22:36:44 2013, rana, Electronics, Lab Work, s/n #115: work in progress IMG_0217.JPG
    Reply  Thu Jan 10 21:43:02 2013, rana, Electronics, Lab Work, s/n #115: work in progress 
       Reply  Wed Jan 30 21:13:53 2013, rana, Electronics, Lab Work, s/n #115: work in progress 
    Reply  Tue Jan 29 15:51:13 2013, Dmass, Electronics, Lab Work, RFPD #115 
Entry  Tue Jan 29 15:30:46 2013, Dmass, Notes, Meetings, Meeting notes 
    Reply  Tue Jan 29 22:47:49 2013, Zach, Notes, Meetings, Meeting notes tumblr_mby4fmWLEg1qc7mh1.jpg
Entry  Mon Jan 28 21:49:08 2013, Dmass, DailyProgress, Lab Work, Gamma > 0.1 in both diodes 
Entry  Fri Jan 25 03:30:31 2013, Dmass, DailyProgress, Lab Work, Real layout on table, one cavity aligned 
    Reply  Sat Jan 26 18:11:55 2013, Dmass, DailyProgress, Lab Work, More progress 
Entry  Wed Jan 23 17:06:50 2013, nicolas, DailyProgress, Optics, new modematching cryoModematching_20130123.png
    Reply  Wed Jan 23 23:46:16 2013, Dmass, DailyProgress, Optics, new modematching not quite so great? 
Entry  Tue Jan 22 18:50:31 2013, Dmass, DailyProgress, Optics, Laser Damage? 
Entry  Tue Jan 22 15:53:40 2013, Dmass, DailyProgress, Roadmap, Meeting summary Inspector_Gadget.jpg
Entry  Mon Jan 7 19:09:52 2013, dmass, DailyProgress, Lab Work, Mode Matching 
    Reply  Mon Jan 7 19:59:16 2013, nicolas, DailyProgress, Lab Work, Mode Matching cryoPLLModematching.png
       Reply  Thu Jan 10 02:10:34 2013, Dmass, DailyProgress, Lab Work, Mode Matching 
          Reply  Thu Jan 10 18:32:48 2013, Dmass, DailyProgress, Lab Work, Mode Matching 
             Reply  Thu Jan 17 12:42:53 2013, Dmass, DailyProgress, Lab Work, PLL Summary PLLGainPeak.pngCurrent2RadTF.pngPLL.png
                Reply  Fri Jan 18 14:16:01 2013, nicolas, DailyProgress, Lab Work, PLL Summary 
                Reply  Sun Jan 20 21:06:37 2013, Dmass, DailyProgress, Lab Work, PLL Summary v2idummy_load.png
    Reply  Tue Jan 8 03:56:45 2013, dmass, DailyProgress, Lab Work, Mode Matching 
Entry  Mon Jan 14 23:40:25 2013, rana, Electronics, Lab Work, change to MFD 
Entry  Mon Dec 17 18:31:56 2012, Dmass, DailyProgress, Lab Work, Locking "Progress" 
    Reply  Mon Dec 17 19:19:27 2012, nicolas, DailyProgress, Lab Work, Some calculations 
    Reply  Fri Dec 21 15:19:24 2012, nicolas, Electronics, Control System, Locking "Progress" 
       Reply  Mon Jan 7 16:42:22 2013, Dmass, Electronics, Control System, PDHv2 box xsfer function PDHv2_xsfer.png
          Reply  Tue Jan 8 11:31:08 2013, Zach, Electronics, Control System, PDHv2 box xsfer function 
    Reply  Wed Jan 2 16:11:10 2013, Dmass, DailyProgress, Lab Work, 1611 Problem 
Entry  Fri Dec 21 17:06:00 2012, nicolas, rabbott, DailyProgress, Control System, Ringing in the new B'ak'tun oltf.pngIMG_20121221_162553.jpg
    Reply  Tue Dec 25 15:37:48 2012, nicolas, rabbott, DailyProgress, Control System, another thing to do 
    Reply  Mon Jan 7 13:22:13 2013, Zach, DailyProgress, Control System, Ringing in the new B'ak'tun 
Entry  Thu Dec 20 18:26:00 2012, nicolas, DailyProgress, Control System, more loop measurements looppieces.pngopenloops.png
Entry  Thu Dec 20 15:28:23 2012, nicolas, DailyProgress, Control System, PDE open loop gain openloop.png
    Reply  Thu Dec 20 16:31:49 2012, nicolas, DailyProgress, Control System, PDE open loop gain 
Entry  Wed Dec 19 21:55:10 2012, nicolas, DailyProgress, Cavity, cavity locked IMG_20121219_163407.jpg
    Reply  Thu Dec 20 11:22:48 2012, Zach, DailyProgress, Cavity, cavity locked 
Entry  Fri Dec 14 16:44:35 2012, Dmass, Notes, Schematics, PDH Loop Box_diagram.pngBox_diagram.png
    Reply  Tue Dec 18 13:22:24 2012, Zach, Notes, Schematics, PDH Loop 
Entry  Fri Dec 14 04:07:52 2012, Dmass, DailyProgress, Lab Work, Beam aligned to cavity in cryostat 
Entry  Thu Dec 13 00:31:33 2012, Dmass, DailyProgress, Lab Work, Working towards beams into cryostat 
    Reply  Thu Dec 13 15:58:05 2012, Dmass, DailyProgress, Lab Work, Laser Problem? 
Entry  Tue Dec 11 15:36:50 2012, nicolas, Misc, Optics, modematching with available lenses cryoModematching_fewerLenses.pngcryoModematching_fewerLenses.png
Entry  Tue Dec 4 03:55:31 2012, Dmass, DailyProgress, Lab Work, Cavities inside cryostat 
    Reply  Tue Dec 4 22:11:58 2012, Dmass, DailyProgress, Lab Work, Cryostat pumping 
Entry  Mon Nov 19 02:26:01 2012, Dmass, Laser, Cavity, Si Cavity flashes 
    Reply  Tue Nov 20 08:10:18 2012, nicolas, Laser, Cavity, Si Cavity flashes 
    Reply  Tue Nov 20 14:36:48 2012, Dmass, Laser, Cavity, Si Cavity flashes cav_scans.png
       Reply  Wed Nov 28 16:22:27 2012, Dmass, Laser, Cavity, Si Cavity flashes 
          Reply  Wed Nov 28 20:33:21 2012, rana, Laser, Cavity, Si Cavity flashes 
          Reply  Fri Nov 30 03:16:41 2012, Dmass, Laser, Cavity, Si Cavity scans 
             Reply  Sun Dec 2 23:51:51 2012, Dmass, Laser, Cavity, Si Cavity scans sweepz.pngsweep1934a.pngsweep1934b.png
Entry  Thu Nov 29 16:15:33 2012, Dmass, Lab Infrastructure, Safety, DANGER KEEP OUT OF CRYOLAB 
Entry  Fri Nov 16 04:45:28 2012, Dmass, DailyProgress, Lab Work, Cavities assembled! 
    Reply  Tue Nov 20 13:17:48 2012, Dmass, DailyProgress, Lab Work, Cavities assembled! 
       Reply  Wed Nov 21 17:00:57 2012, rana, Cryostat, Optics, viewports 
          Reply  Tue Nov 27 22:11:11 2012, Dmass, Cryostat, Optics, viewports 
          Reply  Wed Nov 28 08:31:20 2012, Steve, Cryostat, Optics, viewports 
Entry  Tue Nov 20 15:49:55 2012, rana, Things to Buy, Cleanliness, map at duty free shop 20121018_162655.jpg
Entry  Thu Nov 15 11:22:38 2012, nicolas, Update, Cavity, quick modematching solution to scan cavity resonance spectrum quickCryoModematching.png
Entry  Wed Nov 14 03:00:56 2012, Dmass, DailyProgress, Cavity, Gluing Woes 
Entry  Mon Nov 12 15:58:32 2012, nicolas, Misc, Optics, Modematching cryoModematching.png
Entry  Mon Nov 5 15:46:11 2012, Dmass, Notes, Drawings, Optics Layout 
Entry  Mon Oct 29 15:34:19 2012, nicolas, Update, Optics, Sapphire window BRDF again IMG_20121026_111458.jpgcloth.pngwindowC.png
    Reply  Thu Nov 1 08:52:49 2012, rana, Update, Optics, Sapphire window BRDF again 
Entry  Fri Oct 19 14:56:38 2012, nicolas, DailyProgress, Optics, Better dark subtraction (window BRDF) 
Entry  Tue Oct 16 17:38:03 2012, nicolas, DailyProgress, Optics, Sapphire window measurements 
Entry  Fri Oct 12 16:09:29 2012, Dmass, DailyProgress, Lab Work, Rad shield work 
Entry  Fri Sep 21 15:46:29 2012, Dmass, DailyProgress, Roadmap, Update 
    Reply  Mon Sep 24 07:06:07 2012, Dmass, DailyProgress, Roadmap, Update 
    Reply  Wed Sep 26 14:22:15 2012, Mike J., DailyProgress, Optics, Window Data 
       Reply  Thu Sep 27 18:04:36 2012, Dmass, DailyProgress, Optics, Window Data 
       Reply  Tue Oct 2 17:57:27 2012, Mike J., DailyProgress, Optics, Window Data Update 
          Reply  Tue Oct 9 15:26:35 2012, Dmass, DailyProgress, Optics, Window Data Update 
             Reply  Thu Oct 11 16:54:50 2012, Dmass, DailyProgress, Optics, Window Data Update 
Entry  Tue Oct 9 19:53:13 2012, Dmass, rana, Summary, Project Schedule, Meeting Notes from Oct. 3 
Entry  Fri Sep 28 15:38:56 2012, dmass, Notes, Project Schedule, Update and Plan 
    Reply  Wed Oct 3 17:22:12 2012, dmass, Notes, Project Schedule, Gluing 
       Reply  Tue Oct 9 14:43:11 2012, dmass, Notes, Project Schedule, Gluing - post dunk tests 
Entry  Mon Oct 8 17:03:13 2012, Dmass, DailyProgress, Purchases, note to self 
Entry  Thu Oct 4 12:35:34 2012, Dmass, Notes, Drawings, The Future! 2012-09-26_14-09-11_770.jpg
Entry  Fri Sep 28 15:26:05 2012, Dmass, DailyProgress, Cleanliness, next to somethingness 
Entry  Wed Sep 12 16:13:36 2012, rana, Things to Buy, Optics, Si optics 
    Reply  Thu Sep 13 16:15:02 2012, Dmass, Things to Buy, Optics, Si optics 
Entry  Tue Sep 11 16:25:38 2012, Dmass, Laser, stuff happens, Laser On, TEC off? 
    Reply  Wed Sep 12 03:14:35 2012, Dmass, Laser, stuff happens, Laser On, TEC off? toelog1.pngtoelog2.png
Entry  Thu Oct 13 12:45:22 2011, Rana, Frank, Lab Infrastructure, Cleanliness, particle counter data for last 30 days Untitled.png
    Reply  Mon Sep 10 15:30:31 2012, Dmass, Lab Infrastructure, Cleanliness, particle counter 
       Reply  Tue Sep 11 13:51:56 2012, Dmass, Lab Infrastructure, Cleanliness, particle counter 
Entry  Tue Sep 4 16:02:50 2012, Dmass, DailyProgress, Lab Work, Near Term Roadmap (updated) 
    Reply  Fri Sep 7 13:32:44 2012, Dmass, DailyProgress, Lab Work, Near Term Roadmap (updated) 
Entry  Tue Sep 4 14:39:35 2012, Mike J., Computing, Cryo, messing with EPICS 
    Reply  Tue Sep 4 14:54:46 2012, Mike J., Computing, Cryo, messing with EPICS is successful 
Entry  Fri Aug 31 15:33:48 2012, Mike J., Things to Buy, General, New Computer 
Entry  Mon Jul 16 17:30:17 2012, Dmass, DailyProgress, Lab Work, Cooldown Status 
    Reply  Wed Jul 18 13:23:14 2012, Dmass, DailyProgress, Lab Work, Cooldown Status 
       Reply  Wed Jul 18 14:08:29 2012, Dmass, DailyProgress, Lab Work, DATA ACQUISITION CHANNEL CHANGE 
          Reply  Thu Jul 19 17:19:04 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
             Reply  Fri Jul 20 13:39:11 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
                Reply  Sat Jul 21 20:32:09 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
                   Reply  Sun Jul 22 23:51:27 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
                      Reply  Mon Jul 23 13:08:40 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
                         Reply  Fri Jul 27 13:16:30 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
                            Reply  Fri Aug 10 13:58:55 2012, Matthew, DailyProgress, Lab Work, Cooldown Update 
                               Reply  Sat Aug 11 16:53:21 2012, Mike J., DailyProgress, Lab Work, Cooldown Update 
                                  Reply  Sun Aug 12 20:20:42 2012, Mike J., DailyProgress, Lab Work, Cooldown Update 
                                     Reply  Mon Aug 13 19:46:50 2012, Mike J., DailyProgress, Lab Work, Cooldown Update 
                                        Reply  Wed Aug 15 01:04:39 2012, Matthew, DailyProgress, Lab Work, Cooldown Update 
                                           Reply  Wed Aug 15 15:26:19 2012, Matthew, DailyProgress, Lab Work, Cooldown Update 
                                              Reply  Tue Aug 28 15:37:47 2012, Matthew, DailyProgress, Lab Work, Cooldown Update 
                                                 Reply  Thu Aug 30 12:27:35 2012, Dmass, DailyProgress, Lab Work, Cooldown Update 
Entry  Wed Aug 15 16:46:45 2012, dmass, Cryostat, Lab Work, Cooldown 1 summary 20day_pressure_1m.png20day_temp_1m.png20day_current.png
    Reply  Sat Aug 18 18:03:32 2012, dmass, Cryostat, Lab Work, Well Then. 
    Reply  Mon Aug 20 17:33:31 2012, dmass, Cryostat, Lab Work, Cooldown 1: more coldplateTemp.png
Entry  Wed Jul 11 17:31:05 2012, Dmass, Cryostat, Cryo, cooldown plots cooldown_pressure.pngcooldown_temp.png
    Reply  Thu Jul 12 17:34:37 2012, Dmass, Cryostat, Cryo, cooldown plots press48hrs.pngtemp48hrs.png
       Reply  Sun Jul 15 13:06:32 2012, Dmass, Cryostat, Cryo, cooldown plots 
          Reply  Tue Jul 17 05:17:32 2012, Matthew, Cryostat, Cryo, cooldown plots thermal_circuit.pngClg_1_error.jpgCooling_1.jpg
             Reply  Tue Jul 17 12:05:52 2012, Dmass, Cryostat, Cryo, cooldown plots 
             Reply  Wed Jul 18 18:28:23 2012, Matthew, Cryostat, Cryo, cooldown plots Cooling_2.jpgClg_2_error.jpg
                Reply  Mon Jul 23 14:51:48 2012, Matthew, Cryostat, Cryo, cooldown plots Clg_2b_error.jpgClg_comp.pdf
                   Reply  Fri Jul 27 17:53:19 2012, Matthew, Cryostat, Cryo, cooldown plots/thermal transfer functions transferfns.m.tar.gztf_est_cool.pngtransfer_functions.pdf
                      Reply  Tue Jul 31 14:34:05 2012, Matthew, Cryostat, Cryo, Thermal transfer functions 
                         Reply  Thu Aug 2 15:38:06 2012, Matthew, Cryostat, Cryo, Thermal transfer functions tf_derivatn.pdftransferfns2.m.tar.gztf_calc_plots.png
                            Reply  Tue Aug 7 01:49:45 2012, Matthew, Cryostat, Cryo, Thermal transfer functions tf_est_step1.pngresp_derivatn.pdfStepdown_1.pngStepdown_2.pngStepdown_3.png
                               Reply  Wed Aug 8 21:07:12 2012, Matthew, Cryostat, Cryo, Thermal transfer functions Stepup_comp.pngStepup_fit.pngSteps2_comp.png
Entry  Fri Jul 6 15:35:30 2012, Mike J., Computing, Vacuum, Data Channels & Running Processes 
    Reply  Sun Aug 5 16:21:28 2012, Dmass, Computing, Vacuum, Data Channels & Running Processes 
       Reply  Mon Aug 6 14:40:16 2012, Mike J., Computing, Vacuum, Data Channels & Running Processes 
          Reply  Mon Aug 6 23:10:07 2012, Mike J., Computing, Vacuum, Data Channels & Running Processes 
             Reply  Tue Aug 7 00:07:55 2012, Mike J., Computing, Vacuum, Data Channels & Running Processes 
                Reply  Tue Aug 7 13:24:19 2012, Dmass, Computing, Vacuum, Investigation into Data Channels & Running Processes 
                   Reply  Tue Aug 7 16:01:33 2012, Mike J., Computing, Vacuum, Investigation into Data Channels & Running Processes 
                      Reply  Wed Aug 8 15:49:37 2012, Mike J., Computing, Vacuum, Investigation into Data Channels & Running Processes 
                         Reply  Wed Aug 8 17:26:31 2012, Mike J., Computing, Vacuum, Investigation into Data Channels & Running Processes 
Entry  Tue May 1 16:27:47 2012, Dmass, Cryostat, Roadmap, Cooldown (edit in progress) 
    Reply  Thu May 3 17:55:01 2012, Dmass, Cryostat, Roadmap, Front end interface 
       Reply  Thu May 3 20:42:42 2012, Mike J., Cryostat, Roadmap, Front end interface 
          Reply  Fri May 4 16:31:53 2012, Mike J., Cryostat, Roadmap, Front end interface 
          Reply  Tue May 8 21:59:04 2012, Mike J., Cryostat, Roadmap, Front end interface 
             Reply  Wed May 9 14:42:12 2012, Dmass, Cryostat, Roadmap, Front end work summary 
                Reply  Thu May 10 22:12:19 2012, Frank, Cryostat, Roadmap, Front end work summary 
             Reply  Wed May 16 17:13:13 2012, Mike J., Cryostat, Roadmap, Front end interface 
                Reply  Sun May 20 14:14:01 2012, Frank, Cryostat, Roadmap, Vaccum gauges 
       Reply  Thu May 3 21:15:51 2012, Frank, Cryostat, Roadmap, Front end interface 
       Reply  Fri May 4 17:10:09 2012, Mike J., Cryostat, Roadmap, Front end interface 
    Reply  Thu May 10 21:49:28 2012, Dmass, Cryostat, Roadmap, Cooldown (edit in progress) 
       Reply  Thu Jun 7 13:44:50 2012, Dmass, Cryostat, Roadmap, Cooldown status 
          Reply  Tue Jun 26 13:12:50 2012, Dmass, Cryostat, Roadmap, Cooldown status 
             Reply  Wed Jun 27 22:50:03 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                Reply  Mon Jul 2 20:23:59 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                   Reply  Tue Jul 3 14:15:14 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                      Reply  Wed Jul 4 16:18:39 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                         Reply  Fri Jul 6 01:10:04 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                   Reply  Tue Jul 10 14:04:58 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                      Reply  Thu Jul 12 15:14:21 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                      Reply  Sat Jul 14 17:13:06 2012, Dmass, Cryostat, Roadmap, Cooldown status 
                   Reply  Tue Aug 7 13:35:31 2012, Matthew, Cryostat, Roadmap, Cooldown status 
Entry  Fri Aug 3 16:50:02 2012, Mike J., Computing, General, epics on ws1 
    Reply  Fri Aug 3 17:31:59 2012, Mike J., Computing, General, epics on ws1 
Entry  Thu Aug 2 17:16:14 2012, Mike J., Computing, General, ws1 specs 
Entry  Thu Aug 2 14:38:30 2012, Mike J., Computing, General, Crashed ws1 
    Reply  Thu Aug 2 14:41:45 2012, Mike J., Computing, General, EPICS on ws1 
Entry  Tue Jul 17 18:31:05 2012, Mike J., Computing, Vacuum, EPICS on ws1 
    Reply  Mon Jul 23 19:09:01 2012, Mike J., Computing, Vacuum, EPICS on ws1 
       Reply  Thu Jul 26 15:53:48 2012, Mike J., Computing, Vacuum, EPICS on ws1 
          Reply  Thu Jul 26 22:56:50 2012, Mike J., Computing, Vacuum, EPICS on ws1 
             Reply  Fri Jul 27 16:40:02 2012, Mike J., Computing, Vacuum, ws1... 
             Reply  Fri Jul 27 18:53:37 2012, Mike J., Computing, Vacuum, EPICS on ws1 
                Reply  Mon Jul 30 17:42:31 2012, Mike J., Computing, Vacuum, EPICS on ws1 
Entry  Sun Jul 8 05:55:10 2012, Matthew, Cryostat, Vacuum, Measurements of pressure change pressure_change_dataSit_a)_P1.jpgSit_a)_P2.jpgSit_b)_P1.jpgSit_b)_P2.jpg
    Reply  Tue Jul 10 01:51:10 2012, Matthew, Cryostat, Vacuum, Measurements of pressure change Effect_of_outer_on_inner.jpg
       Reply  Tue Jul 10 14:09:45 2012, Matthew, Cryostat, Vacuum, Measurements of pressure change Change_in_flow_into_outer.jpg
Entry  Fri Jul 6 22:03:36 2012, Mike J., Electronics, Vacuum, fb3 Restart 
    Reply  Fri Jul 6 22:16:34 2012, Mike J., Electronics, Vacuum, Input 4 and MKS901P 
       Reply  Mon Jul 9 15:11:07 2012, Mike J., Electronics, Vacuum, Input 4 
Entry  Mon Jul 9 15:08:41 2012, Mike J., Computing, Vacuum, fb3 Restarted 
Entry  Fri Jul 6 03:03:02 2012, Mike J., Electronics, Vacuum, CTC100 Input Cable 
    Reply  Fri Jul 6 22:02:23 2012, Mike J., Electronics, Vacuum, CTC100 Input Cable 
Entry  Fri Jul 6 15:49:12 2012, Mike J., Electronics, Vacuum, CTC100 Scan rate dropped to 1Hz 
Entry  Fri Jul 6 00:50:12 2012, Mike J., Electronics, Vacuum, Vacuum Gauges 1&2 
Entry  Thu Jul 5 18:09:31 2012, Matthew, DailyProgress, General, Inner Heater Problem 
    Reply  Thu Jul 5 21:59:27 2012, Dmass, DailyProgress, General, Inner Heater Problem 
Entry  Thu Jul 5 13:21:00 2012, Dmass, Lab Infrastructure, stuff happens, Missing Personnel 
Entry  Mon Jul 2 21:57:48 2012, Mike J., Things to Buy, Lab Work, Rack Nuts & Bolts (and Screws) 
    Reply  Mon Jul 2 22:26:49 2012, Mike J., Things to Buy, Lab Work, Rack Nuts & Bolts (and Screws) 
Entry  Thu Jun 28 00:12:46 2012, Matthew, Cryostat, Cavity, Radiative Time Constant 2_cylinder_radiative_heat_transfer.JPG
Entry  Thu Jun 7 02:09:15 2012, Mike J., Computing, General, CTC added to startup sequence 
Entry  Mon Nov 21 15:39:00 2011, Frank, Computing, General, how to create an EPICS Appllication using the StreamDevice module 
    Reply  Wed May 23 17:14:27 2012, Mike J., Computing, General, how to create an EPICS Appllication using the StreamDevice module 
       Reply  Wed Jun 6 23:19:10 2012, Mike J., Computing, General, how to create an EPICS Appllication using the StreamDevice module 
Entry  Thu May 31 13:14:48 2012, Frank, Update, Lab Work, Stycast 2850 
Entry  Wed May 23 14:32:41 2012, Frank, Cryostat, Lab Work, wiring to cold plate 
Entry  Sun May 20 22:04:45 2012, Mike J., Cryostat, Sensors, PEM IOC Channels 
Entry  Tue May 15 18:33:08 2012, Frank, Cryostat, Sensors, cables cleaned - leck checking ongoing 
Entry  Mon May 14 17:44:27 2012, Dmass, Frank, DailyProgress, Sensors, cryo cable testing 
    Reply  Mon May 14 22:25:29 2012, Dmass, Frank, DailyProgress, Sensors, cryo cable testing 
Entry  Fri May 11 15:45:29 2012, Dmass, Laser, General, Numbers Needed 
Entry  Fri May 11 12:46:13 2012, Frank, Lab Infrastructure, stuff happens, leveling valves for optics table 
Entry  Tue Apr 17 14:59:11 2012, Dmass, Update, Lab Work, QUESTION 
    Reply  Tue Apr 24 22:31:24 2012, Dmass, Update, Lab Work, Dunk test (progress) 
       Reply  Wed Apr 25 17:33:42 2012, Dmass, Update, Lab Work, Dunk test (progress) 
          Reply  Thu Apr 26 11:38:43 2012, Frank, Update, Lab Work, new coating run 
Entry  Tue Apr 24 22:43:59 2012, Dmass, Update, Optics, Scatter  RGB_image.pdf
    Reply  Tue Apr 24 23:41:03 2012, Dmass, Update, Optics, Scatter Calibration Calib2.pdfCalib1.pdfCalib3.pdfCalib4.pdf
Entry  Thu Apr 12 23:55:50 2012, Dmass, Update, Project Schedule, Weekly Update 
    Reply  Mon Apr 16 17:23:01 2012, Dmass, Update, Project Schedule, Update 
Entry  Tue Apr 10 15:26:47 2012, Dmass, Things to Buy, Purchases, Circulator / Isolator 
Entry  Tue Apr 10 13:55:35 2012, Dmass, Lab Infrastructure, HVAC, Suana 
Entry  Tue Mar 27 11:49:10 2012, Dmass, Cryostat, Cavity, Dummy Spacer Wanted 
    Reply  Fri Apr 6 14:18:51 2012, Dmass, Cryostat, Cavity, Dummy Spacer Wanted 
Entry  Tue Apr 3 13:41:09 2012, Dmass, Electronics, Lab Work, Transfer Function and Noise of PDHv2 box PDHv2_tf.pdfTP6Vnoise.pdf
    Reply  Thu Apr 5 22:45:22 2012, Dmass, Electronics, Lab Work, PDHv2 box 
Entry  Fri Mar 2 12:57:19 2012, Dmass, Notes, Roadmap, Near Future Roadmap 
    Reply  Tue Apr 3 13:49:05 2012, Dmass, Notes, Roadmap, Annular Polishing Update 
       Reply  Wed Apr 4 11:00:58 2012, rana, Notes, Roadmap, Annular Polishing Update 
          Reply  Thu Apr 5 02:49:54 2012, Dmass, Notes, Roadmap, Annular Polishing Update 
             Reply  Thu Apr 5 13:00:24 2012, Dmass, Notes, Roadmap, Annular Polishing Update 
Entry  Tue Feb 28 13:56:28 2012, Dmass, Electronics, Lab Work, Sidebands - resonant EOM circuit 
    Reply  Tue Feb 28 23:14:31 2012, Frank, Electronics, Lab Work, Sidebands - resonant EOM circuit 
       Reply  Wed Feb 29 22:49:43 2012, Dmass, Electronics, Lab Work, Sidebands - resonant EOM circuit 
          Reply  Thu Mar 1 19:41:56 2012, Dmass, Electronics, Lab Work, Sidebands - resonant EOM circuit 
             Reply  Tue Mar 6 02:09:20 2012, Dmass, Electronics, Lab Work, Sidebands - resonant EOM circuit 
                Reply  Tue Mar 6 12:50:49 2012, Dmass, Electronics, Lab Work, M-I-C! K-E-Y! InAirLayoutPics.png
                   Reply  Tue Mar 6 23:42:10 2012, Dmass, Electronics, Lab Work, M-I-C! K-E-Y! PDHv2mod.png
                      Reply  Wed Mar 7 01:00:18 2012, Frank, Electronics, Lab Work, M-I-C! K-E-Y! 
                         Reply  Thu Mar 8 00:50:52 2012, Dmass, Electronics, Lab Work, M-I-C! K-E-Y! 
                            Reply  Thu Mar 8 03:45:59 2012, Dmass, Electronics, Lab Work, Resonant EOM circuit EOMResonantCirc.png
                            Reply  Fri Mar 9 12:46:04 2012, Dmass, Electronics, Lab Work, PDHV2 
                               Reply  Thu Mar 29 00:59:33 2012, Dmass, Electronics, Lab Work, PDHV2 
                                  Reply  Thu Mar 29 15:42:03 2012, Dmass, Electronics, Lab Work, PDHV2 
                                     Reply  Fri Mar 30 12:13:18 2012, Dmass, Electronics, Lab Work, PDHV2 - switching PDHv2_switch_fix.png
Entry  Mon Mar 19 06:00:35 2012, Dmass, Computing, Noise Budget, Thermorefractive WTF rc_si_123_v2.pdf
    Reply  Mon Mar 19 08:30:27 2012, Dmass, Computing, Noise Budget, Thermorefractive WTF 
       Reply  Mon Mar 19 11:12:40 2012, Dmass, Computing, Noise Budget, Noisebudget rc_si_120_v2.pdf
Entry  Fri Mar 9 17:54:26 2012, Dmass, Electronics, Lab Work, Neglected Cavity Pole 
    Reply  Mon Mar 12 12:56:06 2012, Zach, Electronics, Lab Work, Neglected Cavity Pole