Here's how to add slow channels to the framebuilder DAQ:

  1. Edit /etc/advligorts/edc.ini to add the channels to the list
  2. Restart epics data collector: sudo systemctl restart rts-edc
  3. Restart framebuilder: sudo systemctl restart rts-daqd