40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 51 of 52  Not logged in ELOG logo
ID Datedown Author Type Category Subject Text Attachments
  93   Mon Mar 29 17:46:41 2010 Frank, TaraMiscRefCavassembled new vacuum chamberwe cleaned
and assembled the new vaccum chamber. we
installed an electical feedtrough (for sensors
  
  92   Thu Mar 25 13:05:59 2010 FrankMiscRefCavall parts bakedby now all parts are baked and ready for
assembly. The only part we couldn't bake
is the chamber itself. But Bob said that
  
  91   Tue Mar 23 21:17:56 2010 Frank, TaraMiscRefCavfoam cut & partly assembledwe've cut the rest of the foam parts to
fit on the smaller diameter (the main tube
with the heaters). We already started to
  
  90   Tue Mar 23 00:26:43 2010 Frank, TaraMiscRefCavongoing workover the weekend we baked the two AR-coated
windows for the new chamber.  Bob doesn't
need the oven the next couple of days so
  
  89   Thu Mar 11 22:45:58 2010 Tara ChalermsongsakLaserRC noiseVCO f noiseI measured the VCO noise again.  2
methods that I tried
1) Measuring noise from a) suppressed
 VCO_noise.png 
  88   Fri Mar 5 14:40:21 2010 FrankLaserRC noiseNoise from VCO


   
        
            
 irf2023_@80Mhz.png 
  87   Fri Mar 5 00:34:09 2010 FrankLaserRC noiseNoise from VCO


   
        
            
  
  86   Thu Mar 4 19:44:08 2010 Tara ChalermsongsakLaserRC noiseNoise from VCOVCO frequency noise is measured. V input
is 4.7 Volt. The signal output from the VCO
(which controls the AOM) is mixed with signal
 Noise20100304.jpg 
  85   Wed Mar 3 15:59:10 2010 Tara ChalermsongsakLaserRC noiseNoise from function generator I took the data of frequency noise
of the functiongenerator("Marconi")
and spectrum analyzer's noise from Mott's
 Noise.pdfNoise.fig 
  84   Wed Mar 3 08:46:26 2010 ranaLaserRC noiseNoise as measured by the 40m MCThis
link points to a measurement of the frequency
noise at the 40m.
  
  83   Mon Mar 1 22:39:39 2010 ranaLaserRC noiseNoise Budget40m entry on RIN induced thermo-optic noise
here
  
  82   Mon Mar 1 17:52:46 2010 Tara ChalermsongsakLaserRC noiseNew ResultI got a quarter wave plate from Greg Ogin
this afternoon. The attached plots show:
black-> RC noise when there are
 Mar01_RCnoise.png 
  81   Sun Feb 28 23:53:21 2010 ranaLaserRC noiseNoise Budget   rcnb.png 
  80   Fri Feb 26 15:15:56 2010 Tara ChalermsongsakLaserRC noisequarter wave plate added/power from Ref and A Cavs measuredI borrowed one of the quarter wave plate
and added it after the beam from the Ref
Cav. One more QWP is needed for the ACav.
  
  79   Fri Feb 26 11:40:47 2010 FrankComputingDAQacav VME crate stopped workinglast night one of the DAQ cards failed
and the acav crate stopped working, so also
the temp stabilization of the analyzer cavity
  
  78   Thu Feb 25 19:03:59 2010 Tara ChalermsongsakLaserRC noiseNoise floor from PD and SR560Noise floor from PD and SR560 are measured,
then converted from V/rHz to frequncy/rHz
by the calibration from IFR2023 (0.7 MHz/Volt).
 noise_floor.png 
  77   Wed Feb 24 20:07:00 2010 Tara ChalermsongsakLaserRC noiseRC frequency noise I changed the gain setting on SR560
to find how it will effect the noise floor
of the RC noise.
 rf_noise_feb24_2010.png 
  76   Wed Feb 24 19:40:25 2010 Tara ChalermsongsakLaserRC noisecalibrating ifr2023The calibration for ifr203 input for external
frequency modulation is 
 calibration_feb_24.png 
  75   Wed Feb 24 11:58:20 2010 ranaLaserRefCavsuccessfully use ifr2023 to track the frequncy drift of the beatVolts? What are Volts???
This plot should be converted into
radians/rHz or Hz/rHz in order to be used.
  
  74   Tue Feb 23 20:13:00 2010 Tara ChalermsongsakLaserRefCavsuccessfully use ifr2023 to track the frequncy drift of the beat  The drift in the demodulated signal
(beat frequency x local oscillator) can be
tracked by using ifr2023 and sr560. We successfully
 02_23_2010.pdf 
  73   Mon Feb 22 18:58:23 2010 Tara ChalermsongsakLaserRefCavbeat frequency between transmitted beams Today  we finally see the beat
between transmited beams from Ref Cavity
and A Cavity.  Now we are trying to
 02.TIF 
  72   Mon Feb 22 16:21:43 2010 Frank, TaraLaserRC noiseboth cavities locked, optimizing beat signaltuned the temperatures over night to be
able to lock both cavities today. Cavities
are now locked and Tara is optimizing the
  
  71   Mon Feb 22 11:25:51 2010 FrankLaserLaserlaser fault againthe laser stopped working while beeing
in the lab but not touching the laser or
table or anything. I was looking for an EOM
  
  70   Fri Feb 19 18:23:24 2010 Tara ChalermsongsakLaserRefCavalignment for measuring beat between 2 cavitiesI finished aligning the beams from Ref
cavity and Acavity, broke a connector on
the PD we were going to used to measure the
  
  69   Fri Feb 19 00:31:40 2010 FrankLaserLaser100mW lightwave NPRO slopePeter gave me the hint that the default
values are stored in an eeprom in the laser
head. So connecting the head to a driver
 NPRO_slope_2010-02-19.png 
  68   Thu Feb 18 15:07:39 2010 FrankMiscLaserboth IR viewers missingso please bring it back - we are waiting
for it and can't go on without those... For
the future: if you take it, bring it back
  
  67   Wed Feb 17 15:40:04 2010 FrankLaserLaserold 100mW NPROdoes anyone know the typical operating
current for the 100mW lightwave laser model
? (M126N-1064-100) It's typically ~1.1A for
  
  66   Tue Feb 16 19:33:53 2010 FrankLaserLaserseveral shutdowns the last dayswe had several shutdowns of the laser within
the last days. A couple of times the well
known "HT error", today we had
  
  65   Fri Feb 12 12:46:38 2010 Tara ChalermsongsakLaserLasera picture of beam path on the optic benchI took a picture of the setup in
PSL lab, and drew a line for laser path.
I omit the mode cleaning part since it's
 psl_full_beam.jpg 
  64   Wed Feb 10 18:04:01 2010 Tara ChalermsongsakLaserRefCavQPD calibrationToday I calibrated the QPD on the ref cavity.
The armlength from AOM to the quad is 2.1
m.
  
  63   Wed Feb 10 04:01:50 2010 ranaLaserRC noiseeven newer resultsLooking better. I'm curious about what
the existing loop shapes are. The old FSS
hardware is designed to drive an NPRO + 1
  
  62   Tue Feb 9 18:33:59 2010 FrankLaserRC noiseeven newer resultsmeasured a couple of times today with everything
re-aligned and different gain settings for
the FSS stuff. Measured also to lower frequencies.
 refcav-noise_2010-02-09.png 
  61   Mon Feb 8 22:03:32 2010 FrankLaserRC noisenew resultseverything is back, pointing is much much
less, power modulation too, ugf of the other
loop is much higher - but nevertheless the
 refcav-noise_2010-02-08.png 
  60   Mon Feb 8 18:27:42 2010 Tara ChalermsongsakLaserRefCavChaging Isomet AOM to Crystal Tech AOM


  
  59   Mon Feb 8 18:12:46 2010 FrankNotesAOMimpedance measurementsmeasured the impedance from 70MHz to 90MHz
for three different AOMs we had in the lab
- two Isomet 1205C-843 and one Crystal Technologies
 AOM-impedance_2010-02-08.png 
  58   Mon Feb 8 18:08:53 2010 FrankMiscAOMthermal images of AOMtook some images with the thermal imaging
camera of the AOM installed in the PSL so
far. The first three pictures show the AOM
 9x 
  57   Sun Feb 7 20:56:03 2010 FrankLaserRefCavAOM power modulation & pointingseems like a bad AOM and an impedance matching
problem together. exchanging the semi-rigid
cable by other cables produces a lot of different
  
  56   Sun Feb 7 18:29:06 2010 FrankLaserLasernew channels + changesadded the following channels:
C3:PSL-RCAV_DIFFPWR : diffracted
power (single pass) measured behind curved
  
  55   Sat Feb 6 12:19:14 2010 ranaLaserRefCavstrange things going on Seem like
a screwy AOM. I would take the double-passed
  
  54   Fri Feb 5 21:53:13 2010 FrankLaserRefCavstrange things going onin order to get an idea about the part/subsystem
causing the RF power modulation while sweeping
the VCO frequency i changed the length of
 AOM-cable-length.JPG 
  53   Fri Feb 5 21:10:48 2010 FrankLaserRefCavnew PD for frequency-shifted power detectionadded a detector behind the curved mirror
to measure the changes in deflected power
(1.order) while changing the frequency of
  
  52   Fri Feb 5 20:53:58 2010 FrankLaserRefCavlatest values for refcavvalues for  VCO pwr 4.7V
RCTRANSPD signal: 5.17V
DC-level of RF-PD:
  
  51   Fri Feb 5 20:37:06 2010 Tara ChalermsongsakLaserRefCavbetter pointing alignment After adjusting the mirror for reflecting
beam back to the AOM, the QPD signal shows
the better alignment. Before the voltage
  
  50   Fri Feb 5 05:13:09 2010 Peter, FrankLaserRefCaveverything back onlinewe spent the whole night to re-align everything.
By now everything is back online, both cavities
were locked.for a short time. We still have
  
  49   Thu Feb 4 22:01:27 2010 FrankLaserRefCavacav re-alignedacav is now re-aligned. As Tara stopped
aligning the AOM i will use the NPRO pzt
to lock it (instead of the VCO). Then i will
  
  48   Thu Feb 4 20:13:53 2010 FrankLaserLaseroutput coupler to acav changedexchanged the old mirror (T330-HR, T331-AR)
by a simple Y1-1025-45P to get more power.
measured laser power : 7.17W
  
  47   Wed Feb 3 23:41:11 2010 FrankLaserRefCavTF of ACAV (VCO+cavity+pd+mixer)measured tf of the analyzer cavity including
VCO (wideband input, around 80MHz center
frequency), double-passed AOM, cavity, pd
 TF_acav_pdh_all.pdf 
  46   Wed Feb 3 18:58:50 2010 TaraLaserRefCavfrequency findings When the VCO is modulated by a triangular
function +/- 6V, a small fluctuation is observed
in transmitted and reflected beam. There
 comparison.JPGTbeam.JPGRbeam.JPG 
  45   Wed Feb 3 16:19:52 2010 Tara ChalermsongsakLaserRefCavfrequency findings


   
        
            
 power_at_AOM.jpgReflected_pwr_from_AOM.jpg 
  44   Wed Feb 3 13:05:26 2010 FrankLaserRefCavbeam pointing @ refvacmeasured the beam pointing caused by driving
the AOM frequency modulation input. data
is uncalibrated so far, just a screenshot
 pointing.jpg 
ELOG V3.1.3-