ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
100
|
Fri Apr 9 21:34:15 2010 |
Frank | Computing | DAQ | new RT system | i assembled everything and made all the
cables for power distribution etc. I also
got (the last) timing slave from Rolf. |
|
99
|
Wed Apr 7 18:29:16 2010 |
Tara Chalermsongsak | Laser | RefCav | Calculation for higher order mode's frequency | There's a correction
1) the beam waist inside the cavity,
it seems that the 237 um(which corresponds |
|
98
|
Wed Apr 7 12:30:47 2010 |
rana | Laser | RefCav | Calculation for higher order mode's frequency | I deleted your plot, since it contained
no axes labels. We have a strict rule
against plots like those. You must have physical |
|
97
|
Tue Apr 6 18:39:04 2010 |
Tara Chalermsongsak | Laser | RefCav | Calculation for higher order mode's frequency | I calculated the frequency for other
higher Hermite-Gaussian modes, (n+m up to
20) to make sure that there is no overlap |
|
96
|
Fri Apr 2 00:35:00 2010 |
Frank | Misc | RefCav | new chamber almost ready | the new chamber is almost ready. I've attached
three of four heaters, the fourth one has
a fabrication error and has to be replaced. |
|
95
|
Thu Apr 1 15:38:38 2010 |
Frank | Misc | DAQ | RT DAQ equipment arrived | this afternoon the PSL RT DAQ equipment
arrived and we moved all the stuff down to
the PSL lab. We now have to expansion chassis, |
|
94
|
Wed Mar 31 20:46:22 2010 |
Frank | Misc | RefCav | ion pumps | i've made a cable to test the two Varian
ion pumps we have. Before we move the
cavity to the new chamber i would like to |
|
93
|
Mon Mar 29 17:46:41 2010 |
Frank, Tara | Misc | RefCav | assembled new vacuum chamber | we cleaned
and assembled the new vaccum chamber. we
installed an electical feedtrough (for sensors |
|
92
|
Thu Mar 25 13:05:59 2010 |
Frank | Misc | RefCav | all parts baked | by now all parts are baked and ready for
assembly. The only part we couldn't bake
is the chamber itself. But Bob said that |
|
91
|
Tue Mar 23 21:17:56 2010 |
Frank, Tara | Misc | RefCav | foam cut & partly assembled | we've cut the rest of the foam parts to
fit on the smaller diameter (the main tube
with the heaters). We already started to |
|
90
|
Tue Mar 23 00:26:43 2010 |
Frank, Tara | Misc | RefCav | ongoing work | over the weekend we baked the two AR-coated
windows for the new chamber. Bob doesn't
need the oven the next couple of days so |
|
89
|
Thu Mar 11 22:45:58 2010 |
Tara Chalermsongsak | Laser | RC noise | VCO f noise | I measured the VCO noise again. 2
methods that I tried
1) Measuring noise from a) suppressed |
|
88
|
Fri Mar 5 14:40:21 2010 |
Frank | Laser | RC noise | Noise from VCO |
|
|
87
|
Fri Mar 5 00:34:09 2010 |
Frank | Laser | RC noise | Noise from VCO |
|
|
86
|
Thu Mar 4 19:44:08 2010 |
Tara Chalermsongsak | Laser | RC noise | Noise from VCO | VCO frequency noise is measured. V input
is 4.7 Volt. The signal output from the VCO
(which controls the AOM) is mixed with signal |
|
85
|
Wed Mar 3 15:59:10 2010 |
Tara Chalermsongsak | Laser | RC noise | Noise from function generator | I took the data of frequency noise
of the functiongenerator("Marconi")
and spectrum analyzer's noise from Mott's |
 |
84
|
Wed Mar 3 08:46:26 2010 |
rana | Laser | RC noise | Noise as measured by the 40m MC | This
link points to a measurement of the frequency
noise at the 40m. |
|
83
|
Mon Mar 1 22:39:39 2010 |
rana | Laser | RC noise | Noise Budget | 40m entry on RIN induced thermo-optic noise
here |
|
82
|
Mon Mar 1 17:52:46 2010 |
Tara Chalermsongsak | Laser | RC noise | New Result | I got a quarter wave plate from Greg Ogin
this afternoon. The attached plots show:
black-> RC noise when there are |
|
81
|
Sun Feb 28 23:53:21 2010 |
rana | Laser | RC noise | Noise Budget | |
|
80
|
Fri Feb 26 15:15:56 2010 |
Tara Chalermsongsak | Laser | RC noise | quarter wave plate added/power from Ref and A Cavs measured | I borrowed one of the quarter wave plate
and added it after the beam from the Ref
Cav. One more QWP is needed for the ACav. |
|
79
|
Fri Feb 26 11:40:47 2010 |
Frank | Computing | DAQ | acav VME crate stopped working | last night one of the DAQ cards failed
and the acav crate stopped working, so also
the temp stabilization of the analyzer cavity |
|
78
|
Thu Feb 25 19:03:59 2010 |
Tara Chalermsongsak | Laser | RC noise | Noise floor from PD and SR560 | Noise floor from PD and SR560 are measured,
then converted from V/rHz to frequncy/rHz
by the calibration from IFR2023 (0.7 MHz/Volt). |
|
77
|
Wed Feb 24 20:07:00 2010 |
Tara Chalermsongsak | Laser | RC noise | RC frequency noise | I changed the gain setting on SR560
to find how it will effect the noise floor
of the RC noise. |
|
76
|
Wed Feb 24 19:40:25 2010 |
Tara Chalermsongsak | Laser | RC noise | calibrating ifr2023 | The calibration for ifr203 input for external
frequency modulation is |
|
75
|
Wed Feb 24 11:58:20 2010 |
rana | Laser | RefCav | successfully use ifr2023 to track the frequncy drift of the beat | Volts? What are Volts???
This plot should be converted into
radians/rHz or Hz/rHz in order to be used. |
|
74
|
Tue Feb 23 20:13:00 2010 |
Tara Chalermsongsak | Laser | RefCav | successfully use ifr2023 to track the frequncy drift of the beat | The drift in the demodulated signal
(beat frequency x local oscillator) can be
tracked by using ifr2023 and sr560. We successfully |
|
73
|
Mon Feb 22 18:58:23 2010 |
Tara Chalermsongsak | Laser | RefCav | beat frequency between transmitted beams | Today we finally see the beat
between transmited beams from Ref Cavity
and A Cavity. Now we are trying to |
|
72
|
Mon Feb 22 16:21:43 2010 |
Frank, Tara | Laser | RC noise | both cavities locked, optimizing beat signal | tuned the temperatures over night to be
able to lock both cavities today. Cavities
are now locked and Tara is optimizing the |
|
71
|
Mon Feb 22 11:25:51 2010 |
Frank | Laser | Laser | laser fault again | the laser stopped working while beeing
in the lab but not touching the laser or
table or anything. I was looking for an EOM |
|
70
|
Fri Feb 19 18:23:24 2010 |
Tara Chalermsongsak | Laser | RefCav | alignment for measuring beat between 2 cavities | I finished aligning the beams from Ref
cavity and Acavity, broke a connector on
the PD we were going to used to measure the |
|
69
|
Fri Feb 19 00:31:40 2010 |
Frank | Laser | Laser | 100mW lightwave NPRO slope | Peter gave me the hint that the default
values are stored in an eeprom in the laser
head. So connecting the head to a driver |
|
68
|
Thu Feb 18 15:07:39 2010 |
Frank | Misc | Laser | both IR viewers missing | so please bring it back - we are waiting
for it and can't go on without those... For
the future: if you take it, bring it back |
|
67
|
Wed Feb 17 15:40:04 2010 |
Frank | Laser | Laser | old 100mW NPRO | does anyone know the typical operating
current for the 100mW lightwave laser model
? (M126N-1064-100) It's typically ~1.1A for |
|
66
|
Tue Feb 16 19:33:53 2010 |
Frank | Laser | Laser | several shutdowns the last days | we had several shutdowns of the laser within
the last days. A couple of times the well
known "HT error", today we had |
|
65
|
Fri Feb 12 12:46:38 2010 |
Tara Chalermsongsak | Laser | Laser | a picture of beam path on the optic bench | I took a picture of the setup in
PSL lab, and drew a line for laser path.
I omit the mode cleaning part since it's |
|
64
|
Wed Feb 10 18:04:01 2010 |
Tara Chalermsongsak | Laser | RefCav | QPD calibration | Today I calibrated the QPD on the ref cavity.
The armlength from AOM to the quad is 2.1
m. |
|
63
|
Wed Feb 10 04:01:50 2010 |
rana | Laser | RC noise | even newer results | Looking better. I'm curious about what
the existing loop shapes are. The old FSS
hardware is designed to drive an NPRO + 1 |
|
62
|
Tue Feb 9 18:33:59 2010 |
Frank | Laser | RC noise | even newer results | measured a couple of times today with everything
re-aligned and different gain settings for
the FSS stuff. Measured also to lower frequencies. |
|
61
|
Mon Feb 8 22:03:32 2010 |
Frank | Laser | RC noise | new results | everything is back, pointing is much much
less, power modulation too, ugf of the other
loop is much higher - but nevertheless the |
|
60
|
Mon Feb 8 18:27:42 2010 |
Tara Chalermsongsak | Laser | RefCav | Chaging Isomet AOM to Crystal Tech AOM |
|
|
59
|
Mon Feb 8 18:12:46 2010 |
Frank | Notes | AOM | impedance measurements | measured the impedance from 70MHz to 90MHz
for three different AOMs we had in the lab
- two Isomet 1205C-843 and one Crystal Technologies |
|
58
|
Mon Feb 8 18:08:53 2010 |
Frank | Misc | AOM | thermal images of AOM | took some images with the thermal imaging
camera of the AOM installed in the PSL so
far. The first three pictures show the AOM |
9x |
57
|
Sun Feb 7 20:56:03 2010 |
Frank | Laser | RefCav | AOM power modulation & pointing | seems like a bad AOM and an impedance matching
problem together. exchanging the semi-rigid
cable by other cables produces a lot of different |
|
56
|
Sun Feb 7 18:29:06 2010 |
Frank | Laser | Laser | new channels + changes | added the following channels:
C3:PSL-RCAV_DIFFPWR : diffracted
power (single pass) measured behind curved |
|
55
|
Sat Feb 6 12:19:14 2010 |
rana | Laser | RefCav | strange things going on | Seem like
a screwy AOM. I would take the double-passed |
|
54
|
Fri Feb 5 21:53:13 2010 |
Frank | Laser | RefCav | strange things going on | in order to get an idea about the part/subsystem
causing the RF power modulation while sweeping
the VCO frequency i changed the length of |
|
53
|
Fri Feb 5 21:10:48 2010 |
Frank | Laser | RefCav | new PD for frequency-shifted power detection | added a detector behind the curved mirror
to measure the changes in deflected power
(1.order) while changing the frequency of |
|
52
|
Fri Feb 5 20:53:58 2010 |
Frank | Laser | RefCav | latest values for refcav | values for VCO pwr 4.7V
RCTRANSPD signal: 5.17V
DC-level of RF-PD: |
|
51
|
Fri Feb 5 20:37:06 2010 |
Tara Chalermsongsak | Laser | RefCav | better pointing alignment | After adjusting the mirror for reflecting
beam back to the AOM, the QPD signal shows
the better alignment. Before the voltage |
|