2468
|
Wed Oct 30 15:15:28 2019 |
anchal | Notes | PMC | Replacing U5A AD602 didn't solve the issue. | I brought a new AD602AR from 40m and replaced
the U5A
AD602 which from the previous |
|
2469
|
Wed Oct 30 18:35:31 2019 |
anchal | Notes | PMC | Issue closed | It turns out I did not have a full understanding
of the problem and it was not really a problem.
The blanking (pin 4) on U5A AD602 doesn't |
|
2470
|
Fri Nov 1 17:54:47 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - RFPD RF Ouput under inspection | First step in FSS Diagnostics was to see
RF output from the RFPDs in FSS when they
are locked. I ran some extensive measurements |
   |
2471
|
Mon Nov 4 12:15:01 2019 |
anchal | Notes | PMC | Changing the autolocking method | Trying gain sliding like 40m
Rana
told me that in 40m, the PMCs are autolocked
by reducing the gain of the loop and changing |
|
2472
|
Mon Nov 4 15:03:26 2019 |
anchal | DailyProgress | FSS | Raised North TTFSS; Fixed the boxes. | I raised the North TTFSS box by 6 inches
to make way for working on South box and
to reduce the congestion of connectors in |
|
2473
|
Mon Nov 4 20:13:44 2019 |
anchal | Notes | BEAT | Quick note: FSS Loop Gain Changes | South Common Gain: 24 dB! , Fast Gain:
14 dB
North Common Gain: 10 dB, Fast |
|
2474
|
Tue Nov 5 18:37:59 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - TTFSS Testpoint Spectrum Data | Measurement method
All
measurements were taken withAG4395A for high
frequency and SR785 for low frequency and |
|
2475
|
Sat Nov 9 13:46:08 2019 |
shruti | Misc | Electronics Equipment | Borrowed | I've borrowed a Marconi VCO, a
mini-circuits LPF and mixer from the
CTN lab for use at the WB EEshop. |
|
2476
|
Sat Nov 9 19:28:36 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - Loop nonlinearity Test | Method
I've
wrote this script, nonlinTF.py
which controls a Marconi 2023A and SR785 |
  |
2477
|
Mon Nov 11 20:42:49 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - Two Tone Test | Method
RFPD of the FSS loops were
tested through there Test input ports (Updated |
  |
2478
|
Tue Nov 12 11:39:48 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - RFPD RF Ouput under inspection | I calculated these values by integrating
in the 8 MHz neighborhood around the marked
harmonic peak, the power spectral density |
|
2479
|
Tue Nov 12 18:36:59 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - Two Tone Third Order Intermodulation Test | In line with industrial practices, I did
two tone third order intermodulation test
today on the FSS RFPDs. This test was inspired |
|
2480
|
Thu Nov 14 12:19:32 2019 |
rana | DailyProgress | FSS | FSS Diagnostics - Two Tone Third Order Intermodulation Test | cool - how bout use this new no-how to
estimate the excess in FSS? |
|
2481
|
Tue Nov 19 18:51:02 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - Second-order Distortion Calculation | I did some theoretical calculations using
the datasheet value of second harmonic SFDR |
 |
2482
|
Wed Nov 27 13:59:24 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - TTFSS TP1 TimeSeries | I took time-series data at TP1
on NFSS. This is just after
the elliptical filter which is after the |
|
2483
|
Wed Nov 27 15:17:51 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - Quick HF OLTF of NFSS | I quickly took a high-frequency Open Loop
Gain measurement of NFSS loop at 10 dB COM
Gain and 10 dB FAST gain, using the same |
|
2484
|
Wed Nov 27 16:31:20 2019 |
rana | DailyProgress | FSS | FSS Diagnostics - Quick HF OLTF of NFSS | I doubt it.
When feedback loops be noisy and
busted, |
|
2485
|
Tue Dec 3 17:27:54 2019 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 | The new circuit design has been built and
is shown below. I tested the transfer functions
and the PZT path looks good by eye but the |
 |
2486
|
Wed Dec 4 17:09:44 2019 |
anchal | DailyProgress | TempCtrl | Increased range of out-of-loop temperature sensor | This has happened few times now that acromag
channel for the can heater driver stopped
updating according to the PID script and |
|
2487
|
Wed Dec 4 18:11:09 2019 |
anchal | DailyProgress | FSS | Free running laser frequency noise spectrum | I took a spectrum of PMC error signal when
the FSS loop is not closed. This should provide
a rough estimate of the free running laser |
|
2488
|
Thu Dec 5 18:25:11 2019 |
rana | DailyProgress | FSS | Free running laser frequency noise spectrum | when the
NPRO crystal is oscillatin
|
|
2489
|
Mon Dec 9 18:08:13 2019 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 | I tested the circuit and got the attached
results. The PZT transfer function looks
reasonable. some adjustments to the values |
 |
2490
|
Mon Dec 9 19:54:44 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - How much distortion affects the functioning of PDH? | I'm trying to think hard with my small
brain how the distortion would affect the
PDH functioning and inject noise in the frequency |
|
2491
|
Tue Dec 10 11:57:58 2019 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 |
First, off I forgot a resistor
on the previous diagram so here is the fixed |
|
2492
|
Tue Dec 10 17:03:41 2019 |
anchal | DailyProgress | Laser | Laser Settings back to defaults | I put laser settings on both North and
South Cavities back to default. From this
point onwards, all settings about the lasers |
|
2493
|
Thu Dec 12 11:54:11 2019 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 | Testing the circuit using SRmeasure
and AGmeasure, I got more accurate readings
of the transfer functions. The PZT path TF |
   |
2494
|
Thu Dec 12 19:05:33 2019 |
rana | Notes | FSS | FSS Plant Model v2 | please overlay all the plots and also include
the ideal TFs - its hard to understand anything
without the comparisons |
|
2495
|
Thu Dec 12 19:15:55 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - Beatnote Spectrum wrt Laser Power and Modulation Index | I took beatnote spectrums in the current
modulation index (was set to around 0.3 earlier).
Then I took spectrum after attenuating the |
|
2496
|
Fri Dec 13 16:24:02 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - RFPD Circuit Latest Available Photos | I found the latest available photos for
the Cavity Reflection RFPD circuits.
|
   |
2497
|
Fri Dec 13 17:44:05 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - RFPD RF Coupled Output Offset | I rechecked the 20dB coupled RF output
of SN009 (RFPD on north Cavity reflection)
and SN010 (RFPD on south Cavity refleciton). |
|
2498
|
Mon Dec 16 09:43:56 2019 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 | In talks with Anchal, we have adapted our
model and the transfer function fits rather
well. These measurements were taken with |
  |
2499
|
Tue Dec 17 16:55:07 2019 |
anchal | DailyProgress | FSS | FSS Diagnostics - TTFSS North U7 Boost Stage Input-Output TimeSeries | As suggested few group meetings ago, I
took time series data at the input and output
of boost stage opamp U7 |
|
2500
|
Tue Dec 17 18:29:58 2019 |
anchal | DailyProgress | FSS | Need for ISS? | If we are going to keep the same laser
with busted Noise Eater, should be go in
the direction of implementing the ISS? |
|
2501
|
Wed Dec 18 14:04:43 2019 |
anchal | DailyProgress | Laser | South Laser Power Dropped. | After the last calibration, South Laser
power at Laser head determined by its internal
photodiode and show as setting PWR today |
|
2502
|
Wed Dec 18 18:40:32 2019 |
anchal | DailyProgress | FSS | Maybe the NPRO Laser isn't bad after all | Today I inserted two photodiodes, Thorlabs
PDA10CS at (110,44)
at dumped end of a PBS before PMC and |
|
2503
|
Wed Dec 18 22:03:17 2019 |
rana | DailyProgress | FSS | Maybe the NPRO Laser isn't bad after all | Could be that either
the FSS makes RIN through
driving the PZT / making beam jitter
FSS |
|
2504
|
Fri Dec 20 15:00:30 2019 |
anchal | DailyProgress | FSS | PZT, EOM to RIN TF Measurement | I took some TF measurements, but I'm
not sure if I used the right method to do
this. All the resutls look essentially the |
|
2505
|
Fri Dec 20 18:08:44 2019 |
anchal | DailyProgress | FSS | PZT, EOM to RIN TF Measurement Through FSS | TF Measurement Method
I
switched on Test1
switch on RF Board to cut off RFPD input |
|
2506
|
Mon Dec 30 10:33:33 2019 |
anchal | Summary | Other | Summary of questions asked in December | For the convenience of others, I'm
summarizing the open questions I asked on
elog in December. Comments on the posts, |
|
2507
|
Tue Jan 7 17:59:20 2020 |
anchal | DailyProgress | FSS | NPMC TF | Method:
I
injected excitation at FP1Test
and readout at Mixer |
|
2508
|
Thu Jan 9 19:00:19 2020 |
anchal | DailyProgress | FSS | TTFSS OLTFs | I repeated this measurement to compare
later after changes to RFPDs.
|
|
2509
|
Mon Jan 13 19:04:38 2020 |
anchal | DailyProgress | FSS | FSS Diagnostics - SN009 (North RFPD) Notch Improvement Attempt | Circuit changes (Updated
Schematic)
I made
the following changes to SN009: |
  |
2510
|
Tue Jan 14 13:30:39 2020 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 | I made a more advanced model of the circuit
using Zero and compared them to the
experimental results. |
  |
2511
|
Tue Jan 14 13:32:16 2020 |
Ian MacMillan | Notes | FSS | FSS Plant Model v2 | I also designed a board for the circuit.
This is based on the Zero model from
the previous post. |
  |
2512
|
Tue Jan 14 18:19:33 2020 |
anchal | DailyProgress | FSS | FSS Diagnostics - SN009 (North RFPD) Notch Improved! | Circuit changes (Updated
Schematic)
I made
the following changes to SN009: |
  |
2513
|
Thu Jan 16 11:17:15 2020 |
anchal | DailyProgress | FSS | FSS Diagnostics - SN010 (South RFPD) Notch Improvement Attempt | Circuit changes (Updated
Schematic)
I made
the following changes to SN009: |
  |
2514
|
Thu Jan 16 20:18:44 2020 |
anchal | DailyProgress | FSS | FSS Diagnostics - SN010 (South RFPD) Notch Improved | Circuit changes (Updated
Schematic)
I made
the following changes to SN009: |
  |
2515
|
Wed Jan 22 14:16:28 2020 |
anchal | DailyProgress | FSS | TTFSS OLTFs | Repeated these measurements after changes
to the RFPDs (Notch improved).
Inferences:
No |
|
2516
|
Wed Jan 22 15:20:00 2020 |
anchal | Notes | BEAT | Notch improved on FSS RFPDs. Gain values increased as well. | New Gain Values:
South
Common Gain: 24 dB , Fast Gain: 18 dB
North Common Gain: 14 dB, Fast |
|
2517
|
Wed Jan 22 16:00:26 2020 |
anchal | DailyProgress | FSS | TTFSS OLTFs with Maximum Gain | Repeated these measurements with maximum
possible gain values in the FSS loops.
|
|