  1298   Tue Aug 13 21:45:51 2013 taraDailyProgressNoiseBudgetTransfer Functions (RIN to Frequency noise via photothermal)I rechecked the TF between power fluctuation
and frequency noise in beat measurement that
I did last year. The estimated result agrees
 farsi_2013_08_13.pngfarsi_2013_08_13.figRIN_TO_algaas.pngRIN_TO_algaas.fig 
  1300   Fri Aug 16 04:35:58 2013 taraDailyProgressNoiseBudgetTransfer Functions (RIN to Frequency noise via photothermal)I estimated the requirement for laser RIN
for AlGaAs coatings. The result is a factor
of 5 more stringent from what we need for
 RIN_req_algaas.pngRIN_req_algaas.fig 
  1305   Fri Aug 16 22:05:27 2013 taraDailyProgressBEATnoise hunting Noise hunting is in progress, I checked
the error noise from ACAV and RCAV loops
and compared them to the beat. The beat is
 nb_short_cav.pngnb_short_cav.figbeat_psd.jpg 
  1307   Tue Aug 20 20:10:01 2013 taraDailyProgressBEATnoise huntingNoise hunting is in progress. Today I identified
that scattered light from the window is one
of the problem.
 beat_2013_08_20.png 
  1309   Thu Aug 22 00:29:32 2013 taraDailyProgressNoiseBudgetinstalled EOAMI installed an electro-optic amplitude
modulator (EOAM) in RCAV path. Better optimization
will be needed to reduce extra noise.
 EOAM.jpgnb_short_cav.png 
  1310   Thu Aug 22 13:36:19 2013 taraDailyProgressNoiseBudgetTransfer Functions (RIN to Frequency noise via photothermal) I went through all the code with
Evan and found another mistake. This time
the code should be correct, and the result
 fasi_2013_08_22.pngFarsi_compare.fig 
  1311   Thu Aug 22 20:31:28 2013 taraDailyProgressNoiseBudgetinstalled EOAMThe bump at 2kHz in the beat signal that
I saw before was also from RFAM. By adjusting
the 1/2 waveplate in front of the sideband
 nb_short_cav.pngnb_short_cav.figRFAM.jpg 
  1313   Sat Aug 24 15:42:54 2013 taraDailyProgressVacuumpumping down the chamberI closed the chamber. The turbo pump is
on and pumping down.
 I realigned the beams so the
  
  1315   Tue Aug 27 16:11:26 2013 taraNotesopticcoating optimization for AlGaAs:error analysisSince the optimized layer structure is
designed, I'm checking how the coatings properties
change with error in layer thickness.
 8x 
  1317   Wed Aug 28 20:19:44 2013 taraNotesEOMEOM driver: modificationWe modified the EOM driver, so that the
resonant frequency is now~ 14.75MHz. The
full test will be done later.
 driver1.jpgdriver2.jpgdriver_TF.jpg 
  1318   Wed Aug 28 21:21:38 2013 taraNotesopticGWINC for TO calculation: recapHere is a summary for how I verify the
codes for TO calculation.
So far, we have been using a set
  
  1319   Thu Aug 29 13:25:49 2013 taraDailyProgressVacuumpumping down the chamberThe turbo pump is removed, and the ion
pump is on. The initial value is ~7mA.
I removed the turbo pump and turn
  
  1320   Sun Sep 1 18:38:37 2013 taraNotesopticcoating optimization for AlGaAs:error analysisI updated the optimization and error analysis.
The error in optimized structure is comparable
to that of a standard quarter wave length
 7x 
  1321   Mon Sep 2 03:38:27 2013 taraDailyProgressNoiseBudgetbeatIt's a quiet night, so I went down the
lab to measure the beat signal. We are getting
close. I think I have to review my noise
 zoom_beat_2013_09_02.pngbeat_2013_09_02.pngnb_short_cav.figzoom_beat_2013_09_02.png 
  1322   Mon Sep 2 18:31:46 2013 taraNotesopticcoating optimization for AlGaAs:error analysisCoating optimization and error analysis
are updated, see PSL:1320.
  
  1327   Sat Sep 7 04:29:32 2013 taraDailyProgressNoiseBudgetbeatShort note from tonight measurement:
1) scattered bump from dc to 100Hz
is mostly from seismic. It is worse during
  
  1329   Mon Sep 9 02:27:46 2013 taraDailyProgressNoiseBudgetRIN induced TO noise in beatThe measured RIN is measured and converted
to frequency noise via photo thermal effect
then compared to beat. The effect seems to
 6x 
  1331   Mon Sep 9 21:19:24 2013 taraDailyProgressNoiseBudgetRIN induced TO noise in beatI'm trying to understand the measured RIN
in the setup. The evidence suggests that
the measured RIN in 100Hz- 6kHz, is real
 RIN_ACAV.pngRIN_ACAV.figbenid_ACAV.jpgfront_ACAV.jpg 
  1332   Tue Sep 10 04:53:34 2013 taraDailyProgressNoiseBudgetRIN induced TO noise in beatThe cause of the peaks around 1kHz in RIN
is solved, PMC is the reason. After damping
it, the peaks disappears.
  
  1338   Tue Sep 17 19:43:45 2013 taraSummaryNoiseBudgetCoating Thermal Noise Calculator

    

       
            
  
  1340   Wed Sep 18 21:55:11 2013 taraNotesopticcoating optimization for AlGaAs:error analysis 
Optimized coatings structure.
 
 opt_coatings.mat 
  1342   Thu Sep 19 14:55:11 2013 taraSummaryNoiseBudgetCoating Thermal Noise Calculator

    

       
            
 ThermalUpdateEmbed.pdfThermalUpdateEmbed2.pdf 
  1343   Thu Sep 19 18:09:18 2013 taraSummaryNoiseBudgetCoating Thermal Noise Calculator

    

       
            
  
  1344   Thu Sep 19 20:38:17 2013 taraNotesopticcoating optimization for AlGaAs:error analysisDetails for AlGaAs coatings order

    
    Coating
structure can be found in 
 power_vs_mirror_size.png 
  1345   Fri Sep 20 19:26:45 2013 taraNotesopticcoating optimization for AlGaAs:error analysisI'm using Matt's code to do error analysis
for AlGaAs coatings. This time I vary materials'
parameters and compare the thermo optic noise,
 error_check_params.pngerror_check_params.figerror_thick_params_compare.pngerror_thick_params_compare.fig 
  1351   Mon Sep 23 18:50:05 2013 taraNotesopticcoating optimization for AlGaAs:error analysis


   
        
            
 compare_indices.pngcompare_indices.figcompare_indices.png 
  1356   Thu Sep 26 23:25:40 2013 taraNotesopticcoating optimization for AlGaAs:error analysis I'm trying to find another optimization
that is less sensitive to change in nH and
nL. Here is a few thought and a few examples.
 8x 
  1359   Thu Oct 3 10:34:32 2013 taraNotesopticcoating optimization for AlGaAs:error analysis The new optimization is less sensitive
to the values of refractive indices, but
the overall error will not change much if
  
  1360   Mon Oct 7 19:53:53 2013 taraDailyProgressSeismicnew table legs installedNew legs were installed.  The table
is floated. The cables for signals/ power
supplies will be reconnected later
 newleg.jpg 
  1363   Thu Oct 10 01:59:24 2013 taraNotesopticcoating optimization for AlGaAs:error analysis I recalculated the coatings properties,
with the values of nH and nL to be 3.48 and
2.977. Note about each optimization is included
  
  1365   Fri Oct 11 15:23:54 2013 taraNotesopticcoating optimization for AlGaAs:electric field in coating layerElectric field in coating layer is calculated.
This will be used in loss calculation in
AlGaAs coatings.
 6x 
  1367   Mon Oct 14 21:02:00 2013 taraNotesopticcoating optimization for AlGaAs:variation in xI checked the dependent of coatings properties
with the uncertainty in x (amount of Al in
Al_x Ga_(1-x) As). 
  
  1370   Tue Oct 22 04:34:12 2013 taraDailyProgressSeismicnew table legs installedAfter installing the table legs, I have
been trying to measure the beat. However,
there is an unknown scattered light noise
  
  1374   Sun Oct 27 20:12:25 2013 taraNotesoptic photothermal noise in AlGaAsI revised the calculation for photo-thermal
noise in AlGaAs coatings, the photo thermal
noise should not be a limiting source.
 Int_cotings.pngInt_cotings.fig 
  1376   Wed Oct 30 01:56:38 2013 taraDailyProgressoptictable workI'm optimizing the setup, and clearing
the table a little bit.

    Self homodyne setup in
 oldPBS.jpgnewPBS.jpg 
  1377   Thu Oct 31 00:02:17 2013 taraDailyProgressElectronics EquipmentTTFSSEvan found that when common gain is changed,
DC offset also changes as well. I'm still
looking into the problem.
 offset.pngD040105C.png 
  1379   Fri Nov 1 00:22:40 2013 taraDailyProgressopticmore optimizationI'm putting EOAM back on ACAV path. The
setup is roughly optimized.
(14.75 MHz) EOM , EOAM, quarter waveplate
 foam1.jpgfoam2.jpg 
  1381   Tue Nov 5 01:11:15 2013 taraDailyProgressElectronics EquipmentTTFSS

    

       
            
  
  1383   Wed Nov 6 01:14:58 2013 taraDailyProgressElectronics EquipmentTTFSSWe made a mistake by choosing the input
power to the cavities to be 0.25 mW, so today
I turned them back to 1mW and measure the
 beat_2013_11_05.pngbeat_2013_11_05.fig 
  1384   Thu Nov 7 05:08:13 2013 taraDailyProgressNoiseBudgetphotothermal noise in SiO2/Ta2O5I add the photo thermal noise effect in
the noise budget. With ISS, photothermal
noise should be sufficiently small.
 beat_2013_11_07.pngbeat_2013_11_07.fig 
  1385   Fri Nov 8 03:36:44 2013 taraDailyProgressopticredo- PMC pathI'm re-arranging the optics in PMC path
a bit. The work is in progress, so ACAV path
is still down.
  
  1386   Mon Nov 11 19:37:13 2013 taraDailyProgressopticredo- PMC pathPMC path is back, I aligned the polarization
of the input beam to the BB EOM for TTFSS.
The visibility of PMC is now ~ 80%.
  
  1387   Tue Nov 12 15:27:32 2013 taraNotesDocumentationthesis on ctnI created an svn folder for my thesis on
CTN measurement.
It can be found here
  
  1388   Wed Nov 20 18:19:01 2013 taraDailyProgressNoiseBudgetphotothermal noise in SiO2/Ta2O5I compared our beat measurement with results
from Numata2003 and TNI. They agree well.
I'm quite certain that we reach Brownian
 beat_compare.pngbeat_compare.fig 
  1389   Mon Nov 25 15:28:12 2013 taraNotesRefCaveigenmodes of 1.45" refcavI realized that we have not checked the
eigenmodes of 1.45" cavity yet, so I
used comsol to find out several modes. The
 spacer_eigenmode.mphspacer_br_8_edge.pngspacer_br_8_edge_z.pngspacer_only_z.png 
  1390   Mon Dec 16 15:14:43 2013 taraNotesElectronics EquipmentOLG of RCAV TTFSS open loop gain transfer function
of RCAV is measured. 
 1) how to measure OLG TF
 openloopTF.pngopenloopTF.fig 
  1392   Wed Dec 18 21:05:28 2013 taraNotesoptic photothermal noise in AlGaAs: thickness resolutionWe heard back from G. Cole about the thickness
resolution in the AlGaAs coating manufacturing
process will be around 0.5 A. So I'm checking
 8x 
  1393   Tue Dec 31 19:33:47 2013 taraSummaryNoiseBudgetbeat measurementI got a chance to measure beat measurement.
The noise budget is updated and contains
all dominant noise traces.
 beat_2013_12_24.pngTTFSS.pngRCAV_OLG.pngACAV_OLGTF.png 
  1399   Fri Jan 24 21:13:13 2014 taraDailyProgressDAQmDV in ATFI'm trying to record beat measurement for
a few days. The data will be taken from ATF
using mDV. There are a few issues about mDV
  
  1400   Wed Jan 29 05:44:51 2014 taraSummaryNoiseBudgetNoise budget fitting: need uncertaintiesI looked into the uncertainty in coating
thickness of the QWL SiO2/Ta2O5 coating The
thickness of  4.53 +/- 0.07 um (~1.5%)seems
  
ELOG V3.1.3-