  588   Sat Apr 23 22:15:39 2011 ranaDailyProgressNoiseBudgetRIN coupling to frequency noise 
 The measurement of the RIN
-> frequency coupling of the 40m Reference
  
  589   Sun Apr 24 22:02:07 2011 taraDailyProgressFSSPreparing to install TTFSS I can lock the laser frequency
to RCAV with TTFSS, but the noise in the
beat is higher than before.
 beat_2011_04_24.pngbeat_2011_04_24.png 
  590   Mon Apr 25 10:40:00 2011 FrankDailyProgressNoiseBudgetRIN coupling to frequency noiseat which modulation frequency? The text
doesn't say.

  
  591   Mon Apr 25 17:53:20 2011 taraDailyProgressFSSPreparing to install TTFSSI switched the polarity for EOM actuator
on RCAV loop. Now the beat signal is comparable
to what we had before.
 beat_2011_04_25.png 
  595   Wed Apr 27 22:09:10 2011 taraDailyProgressNoiseBudgetRIN coupling to frequency noise I
list the plan for measuring the effect of
RIN to Frequency noise.
  
  596   Sun May 1 22:39:56 2011 taraDailyProgressNoiseBudgetRIN coupling to frequency noiseI measured
RIN -> frequency noise coupling coefficient
at 10Hz from RCAV. The result is 0.02 Hz/uW
 TF.pngPSD.png 
  597   Mon May 2 10:32:58 2011 FrankDailyProgressNoiseBudgetRIN coupling to frequency noisedid you try to optimie/minimze the coupling
before the measurement? If not you should
check how you can make it worse/better (e.g.
  
  598   Tue May 3 11:59:55 2011 taraDailyProgressNoiseBudgetRIN coupling to frequency noiseThe
coupling coefficient I measured before changed
with input power/ alignment of the beam.
  
  599   Wed May 4 01:20:00 2011 taraDailyProgressopticminimizing RFAM/ aligning 35.5 MHz EOMI minimized
the RFAM by aligning the 35.5 MHz EOM and
  
  600   Mon May 16 22:59:45 2011 frank, taraDailyProgressNoiseBudgetRIN coupling coefficientI tried
to measure coherence TF between RCTRANSPD
and FASTMON, 
 compare.png 
  602   Wed May 18 20:51:35 2011 taraDailyProgressopticoptic layout for new fss setupI planned the layout for new fss setup.

The new setup has 1) both cavities
 fss_layout_2011_05_18.png 
  603   Thu May 19 11:32:46 2011 taraDailyProgressopticoptic layout for new fss setupI added more details on the layout, and
necessary half wave plates in the beam path.
 fss_2011_05_18.png 
  614   Tue Jun 14 23:07:03 2011 taraDailyProgressopticoptic layout for new fss setupThe mode matching for new FSS is calculated.
The plan is shown below.
 
 2aom_fss.png 
  615   Thu Jun 16 00:03:11 2011 taraDailyProgressFSSTF measurement on FAST path for TTFSSI measured
TF of Fast path from TTFSS and compared with
LISO model. The results agree well.
 fastpath.pngTF_fast.pdf 
  617   Mon Jun 27 23:55:43 2011 Raphael CervantesDailyProgressFSSFSS measurements progressUpdate:
Numbers are wrong. Will talk to Tara tonight.
Open Loop transfer function is too low and
 10x 
  618   Wed Jun 29 15:35:06 2011 Raphael CervantesDailyProgressFSSneed help improving LISO modelsI've tried making LISO models for the PZT
path, EOM path, the EOM HV path, and the
notch filter right next to TP2 on the RF
 19x 
  619   Wed Jun 29 15:47:40 2011 JenneDailyProgressPMCLISO modelsJust a thought....
If you're going to post LISO models
(the .fil files), it might be handy to also
  
  620   Wed Jun 29 15:59:51 2011 JenneDailyProgressPMCLISO models

    

       
            
  
  621   Wed Jun 29 18:01:30 2011 Raphael CervantesDailyProgressFSSSuppressed Free Running NoiseThe suppressed NPRO free running noise
is: suppressed NPRO free running noise=NPRO
free running noise / (1+FSS Open Loop Gain)
 FSS_Open_Loop_Gain.jpgNPRO_noise.jpgSuppressed_NPRO_noise.jpg 
  622   Thu Jun 30 03:25:13 2011 KojiDailyProgressPMCneed help improving LISO modelsFor EOM HV:
You need a single zero (or double
zero) in order to make the bend of the magnitude
  
  623   Tue Jul 5 14:30:35 2011 Raphael CervantesDailyProgressFSSneed help improving LISO modelsHey, I tried to improve the models by Koji's
suggestions, but I still can't quite get
them right. Can someone give me some suggestions?
 11x 
  624   Mon Jul 11 15:52:36 2011 RaphaelDailyProgressFSSneed to modify RF summing boxLast Friday, we attempted to measure the
transfer function of the EOM and the EOM
actuator gain. However, we were unsuccessful
 6x 
  626   Thu Jul 14 16:14:09 2011 RaphaelDailyProgressFSSSumming Box CalculationsTara, Frank, and I were unsure of the values
that we read off the summing box board in
the PSL lab.
 13x 
  627   Fri Jul 15 18:37:51 2011 RaphaelDailyProgressFSSPhotodiode modification progressCurrently, I am working on modifying a
photodiode so that will be used to lock the
laser to the reference cavity. We want to
 D980454-00.pdfpd.filPDRF.jpgPDOpAmpGainStability.jpg 
  628   Mon Jul 18 02:20:01 2011 taraDailyProgressopticoptic layout for new fss setup  The
new mode matching for optics in front of
the cavities is done.  The rest (for
 2aom_fss_2011-07-15.png 
  629   Mon Jul 18 11:41:22 2011 ranaDailyProgressopticoptic layout for new fss setupThere's no need to use such a large
spot size on either the AOM or the EOM. 
When using high power this could
  
  630   Mon Jul 18 19:58:05 2011 RaphaelDailyProgressFSSPhotodiode modification progressToday I learned how to solder an inductor
onto a board.
We measured the transfer function
 D980454-00.pdf 
  631   Wed Jul 20 15:54:21 2011 taraDailyProgressopticoptic layout for new fss setup  I edited the layout so that the
spots in both AOMs are 200 um. I'll list
what optics we might have to buy.
 2011_07_20_layout.png 
  632   Wed Jul 20 23:00:30 2011 FrankDailyProgressopticoptic layout for new fss setupthe lens and mirror are in the ATF, a second
VCO is in the left cabinet.
 
  
  633   Thu Jul 21 18:03:20 2011 taraDailyProgressAOMAOM adaptor plate, I made drawings for aom block and adaptor
plate. The assembly is for 3" beam height.
 
 aom_base1.PDFaom_base2.PDFeom_block1.PDFeom_block2.PDF 
  634   Fri Jul 22 00:17:03 2011 RaphaelDailyProgressFSSPhotodiode progressToday I spent the whole day wondering why
I obtained a bad optical transfer function
from the photodiode. It turned out that the
  
  635   Fri Jul 22 16:31:12 2011 taraDailyProgressAOMAOM adaptor plate 
 As Frank suggested, I edited
the drawing, so that the adaptor plate can
 aom_base.PDFeom_block1.PDFeom_block2.PDF 
  636   Fri Jul 22 20:51:13 2011 frank, taraDailyProgressopticcleaning opto mechanical partsAs we removed some optics on the table,
we use pressurized air to blow away dust/dirt
on the mechanical parts (mount/ post/ lens
 IMG_1862.JPGIMG_1863.JPG 
  638   Mon Jul 25 23:59:56 2011 RaphaelDailyProgressElectronics EquipmentPhotodiode ProgressHey, so I readjusted the resonant frequency
of the photodiode so that resonance would
be at ~35.5MHz frequency. Here is the photodiode
 D980454-00.pdfPhotodiode_Optical_TF.jpgjennyLaserSetup.png 
  640   Tue Jul 26 18:42:16 2011 raphael, taraDailyProgressopticcleaning opto mechanical partsToday we removed the optics behind the
PMC, ACAV, and cleaned the table.

      Optic mounts and
 IMG_1866.JPGIMG_1867.JPG 
  642   Wed Jul 27 00:23:12 2011 RaphaelDailyProgressElectronics EquipmentPhotodiode ProgressI took the transfer function of the photodiode
(
 D980454-00.pdfTest_Input_vs_Optical.jpg 
  643   Thu Jul 28 01:24:40 2011 ranaDailyProgressElectronics EquipmentPhotodiode ProgressThis is sort of OK, but check out the 40m
elog for the right way to characterize RFPDs.
You really need more resolution to resolve
  
  644   Thu Jul 28 01:54:21 2011 frank, taraDailyProgressopticcleaning opto mechanical parts  Today we started working on the
layout. There is one mistake in the layout,
the mirror behind AOM for REFCAV is too close
 2011_07_28.pngIMG_1869.JPGIMG_1874.JPGIMG_1875.JPG 
  645   Thu Jul 28 16:42:26 2011 RaphaelDailyProgressFSSfitted LISO models for EOM and PZTI fitted the measured transfer functions
for the EOM and PZT using LISO. Here are
the results:
 6x 
  647   Fri Jul 29 00:42:19 2011 frank, taraDailyProgressopticcleaning opto mechanical parts We preparing optics for the new layout.
To reduce scattering noise, most of the Y1-1064
mirrors we have been using will be replaced
 IMG_1880.JPGIMG_1883.JPGIMG_1889.JPGIMG_1886.JPGIMG_1878.JPG 
  648   Tue Aug 2 23:58:40 2011 taraDailyProgressopticNew RCAV setup is locked  RCAV is locked, I have not
optimized the mode matching yet, the coupling
efficiency is ~ 67%.
 IMG_1911.JPGrcav_2011_08_02.jpg 
  649   Wed Aug 3 18:06:32 2011 RaphaelDailyProgressElectronics Equipmentpdrf progressHey,
I measured the optical transfer function
with more points (again after the floppy
  
  651   Thu Aug 4 22:45:10 2011 RaphaelDailyProgressElectronics Equipmentrfpd progressI measured the shot noise again because
the data I got yesterday was kind of garbage.
I tried to get an error estimate by taking
  
  652   Tue Aug 9 00:01:08 2011 RaphaelDailyProgressFSSsimulink modelHey,
So I'm done-ish with the simulink
file that models the loop that locks the
  
  653   Tue Aug 9 00:39:30 2011 taraDailyProgressopticRCAV modematching optimized I optimized mode matching for RCAV.
The coupling is ~75%.  I also minimized
RFAM from the 35.5MHz EOM.
  
  654   Tue Aug 9 21:12:22 2011 taraDailyProgressFSSOpen loop gain TF measurement of the new setupI checked the RCAV loop performance
with the new layout (double pass AOM + semi
fixed RF summing box). 
 OLGTF.pngsuppressed_noise.png 
  655   Wed Aug 10 20:54:58 2011 taraDailyProgressAOMChanging Crystal Tech AOM to Isomet AOM[koji, frank, tara]
Today we changed the AOM in RCAV
setup from Crystal Tech AOM to Isomet AOM.
  
  656   Thu Aug 11 15:18:28 2011 RaphaelDailyProgressElectronics Equipmentshot noise characterizationHere is the characterization of the shot
noise.
 shotnoise2.jpgshotnoise2.jpgPDOTF.jpg 
  658   Mon Aug 15 23:13:53 2011 taraDailyProgressopticRCAV modematching optimized I recalculated the mode matching
so that the spot radius in AOMs is 100 um.
Now the visibility of RCAV is 90%.
 2011_08_15.png 
  659   Wed Aug 17 20:41:13 2011 taraDailyProgressopticACAV path is upI put most optics on ACAV path. I have
not tried to lock the cavity yet. I'll install
ACAV RFPD next.
 layout_2011_08_17.jpg 
ELOG V3.1.3-