40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 4 of 52  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  151   Mon Jun 7 19:24:04 2010 taracLaserLaserRefCav is lockedRefCav
is locked , the beam is more stable than yesterday
  
  152   Tue Jun 8 03:16:21 2010 FrankLaserLaserRefCav is lockednice  good job!
you can get the names for the channels
  
  153   Tue Jun 8 20:16:21 2010 taracLaserLaserscanning ACavNow I'm
working on aligning the beam into ACav. I
got the reflected light on the PD, and I'll
 aom_eff.png 
  154   Wed Jun 9 03:55:40 2010 FrankLaserLaserscanning ACavThere is no attenuator connected to the
AOM. The device on the AOM (the white attenuator
looking like thing) is a 
  
  156   Wed Jun 9 03:55:41 2010 FrankLaserLaserscanning ACavThere is no attenuator connected to the
AOM. The device on the AOM (the white attenuator
looking like thing) is a 
  
  155   Wed Jun 9 03:55:41 2010 FrankLaserLaserscanning ACavThere is no attenuator connected to the
AOM. The device on the AOM (the white attenuator
looking like thing) is a 
  
  157   Thu Jun 10 00:21:15 2010 taracLaserLaserscanning ACavI'm
scanning the laser to align ACav. It's a
long day of adjusting 4 knobs and 1 lens
 Photo_42.jpg 
  158   Fri Jun 11 01:04:42 2010 taracLaserLaserscanning Acav2From yesterday,
after getting TEM 00 out of the cavity, I
  
  159   Sat Jun 12 17:11:26 2010 KojiElectronicsVCOPSL VCO removed and sent to LLOAs per the request from LLO, the PSL VCO
was sent to the site.
They had malfunctioning of the circuit
  
  160   Mon Jun 14 10:16:54 2010 taracMiscOtherweird TF from PMC servoSince the
VCO has been borrowed, I decide to work on
RefCav path again. To optimize the RefCav
 PMC_bode.pngFSS_fast_bode.pngFSS_PC_bode.png 
  161   Tue Jun 15 09:44:56 2010 taracElectronics PMC servo TF   
The weird TF result from PMC seems to be
the result of the insufficient voltage input.
 PMC2_bode.pngnotch_bode.pngPMC2_bode.png 
  162   Tue Jun 15 10:14:32 2010 FrankElectronics PMC servo TF that's not the TF of the PMC servo, it's
something else. look at the gain level: -100dB.
that's not more than some crosscoupling.
  
  163   Tue Jun 15 13:36:18 2010 taracElectronics debugging PMC servoFrom the
bode plot, something is not quite right.
I'll debug the PMC servo. My plan is
  
  164   Tue Jun 15 15:48:29 2010 FrankComputingDAQDAQ "no sync" problem fixedfixed the "no sync" problem we
had since about three weeks. It was the 100pin
flat ribbon cable from the timing adapter
  
  165   Tue Jun 15 21:28:57 2010 FrankMiscPMCPMC servo problem fixedfound the problem why the PMC servo card
wasn't working: the medm screens on the sun
workstation didn't have a toggle button for
  
  166   Wed Jun 16 00:10:36 2010 FrankComputingDAQnew channels for temp ctrl of both cavitiessome new channels for the temp ctrl of
the two cavities, most of them for debugging
purposes only
  
  167   Wed Jun 16 10:26:01 2010 FrankMiscComputerslatest medm screens from Hanfordgot the latest screens from Hanford in
order to avoid such problems again in the
future. Someone has to search and replace
  
  168   Wed Jun 16 19:43:00 2010 taracLaserPMCPMC and EOM alignment We try
optimizing the PMC transmission in P wave.
  
  169   Sun Jun 20 02:17:06 2010 ranaElectronicsRefCavphase noise of IFR + Rubidiumsee
this entry
  
  170   Mon Jun 21 19:19:12 2010 taracLaserPMCProgress on PSL setup: Tuning phase shift/RF power for PMC All SMA cables for locking
RefCav are made and wired up in their places.
  
  171   Tue Jun 22 17:52:32 2010 FrankLab InfrastructureEnvironmenttemperature time series for the last weektemperature time series for the last couple
of days measured right above the table between
both cavities.
 AmbMon_061710-062210.png 
  172   Tue Jun 22 18:02:32 2010 FrankMiscRefCavheater-to-can time constantmeasured step function from heater to can
temperature. All four sensors show the same.
time constant ~7.5 hours, have to
 StepResponse_Heater-Can.png 
  173   Wed Jun 23 03:24:30 2010 ranaMiscRefCavheater-to-can time constantIn the entry below, Frank meant to
add some commentary explaining that
he thinks this long time constant is anomalously
  
  174   Wed Jun 23 23:52:48 2010 taracLaserRefCavRefCav is locked and optimizedI adjust
the mode matching lenses and align the beam
so that the transmitted power is 
  
  175   Thu Jun 24 09:37:16 2010 ranaLaserRefCavRefCav is locked and optimizedFor the sideband power, you don't really
want to make it so large. All that you really
want is to make sure that the shot-noise
  
  176   Fri Jun 25 18:27:59 2010 taracLaserLasermode matching to ACav  The new driver for
AOM is working, the maximum power is ~1.3w.
  
  177   Mon Jun 28 19:06:40 2010 taracDailyProgressPMCPMC acting weirdThis morning,
the PMC couldn't be locked to the laser.
The FSS servo was disabled during that time.
  
  178   Tue Jun 29 11:15:40 2010 FrankNotesFoamfoam physical propertiesphysical
properties for the new yellow foam used for
insulation (Certifoam 25):
  
  179   Tue Jun 29 11:45:47 2010 FrankHowToNoiseBudgetunit converterhttp://www.matweb.com/tools/unitconverter.aspx   
  180   Tue Jun 29 11:53:41 2010 FrankNotesNoiseBudgetlist of emissivity coefficientssource: http://www.engineeringtoolbox.com/emissivity-coefficients-d_447.html
 

  
  181   Tue Jun 29 13:22:51 2010 JenneNotesNoiseBudgetlist of emissivity coefficients


   
        
            
  
  182   Tue Jun 29 14:20:04 2010 taracNotesLaserCalibration [Hz/V] for modulating signal (PMC and laser)1) DC ext channel
on PMC servo:         
  
  183   Tue Jun 29 14:22:31 2010 FrankNotesNoiseBudgetsummary of emissivity coefficients for refcav experimentemissivity
coefficients - ε - 
(300K)
  
  184   Tue Jun 29 14:59:52 2010 FrankNotesNoiseBudgetbetter list of emissivity coefficientssource : http://www.omega.com/temperature/z/pdf/z088-089.pdf
 emission_coefficients.pdf 
  185   Tue Jun 29 15:13:26 2010 FrankNotesRefCavrefcav physical propertiesrefcav physical properties from CAD
model for heat capacity calculation
volume (incl. mirrors, center
  
  186   Tue Jun 29 17:57:40 2010 taracNotesPMCcoupling eff vs TemperatureWe had a problem with power coupling
efficiency to the PMC.  Sometime it
  
  187   Tue Jun 29 23:56:38 2010 taracNotesPMCPMC servo debugging I
was going to check the TF on each stage of
PMC's servo. 
  
  188   Wed Jun 30 00:37:49 2010 ranaHowToComputersPMC servo debugging

    
        
  
  189   Wed Jun 30 00:59:13 2010 FrankHowToComputersPMC servo debugging


   
        
            
  
  190   Wed Jun 30 11:34:37 2010 FrankHowToPMCPMC fixedthe reason why you had this flickering
problem was that you had too much power on
the RFPD in reflection of the PMC. You already
  
  191   Wed Jun 30 12:31:22 2010 taracHowToPMCPMC fixed


   
        
            
  
  192   Wed Jun 30 12:39:17 2010 FrankHowToPMCPMC fixed


   
        
            
  
  193   Wed Jun 30 15:51:05 2010 FrankHowToNoiseBudgetview factor for two cylinders to calculate heat transfer via radiationview factor for two cylinders to  view_factor.png 
  194   Wed Jun 30 23:26:27 2010 taracDailyProgressRefCavDebugging FSS servo+Locking RefCavsummary of this
entry
  
  195   Thu Jul 1 13:49:58 2010 MeganNotesVCOVCO Output Amplitude Depending on Modlevel InputI measured the output amplitude of the
VCO with different Modlevel voltage inputs
(from 0 V to 5 V) by measuring the RMS voltage
 Output_vs_Modlevel_Voltage.png 
  196   Fri Jul 2 13:45:55 2010 FrankNotesEnvironmentchanged lab temperaturelowered the lab temperature avout 1K to
get some data for the time constant from
the environment to the chamber over the weekend
  
  197   Wed Jul 7 01:02:06 2010 taraDailyProgressLaserLaser driver is stationed on the electronic rackI moved
the laser driver to the electronic rack and
it should stay there for the final setup.
  
  198   Wed Jul 7 10:44:39 2010 MeganSummaryVCOVCO Output vs InputI redid one of the graphs for the output
of the VCO vs the input voltage to make sure
I didn't miscalculate. I got the same graph
 VCOOutputvsInput.png 
  199   Wed Jul 7 15:15:59 2010 MeganDailyProgressVCOPhase Noise MeasurementsI'm currently working on measuring the
phase noise of the Marconis at 80 MHz - I
will be moving on to 160 MHz soon. I'm also
  
  200   Wed Jul 7 16:08:40 2010 MeganSummaryVCOUpdate on VCO offsetI realized I was doing the calculations
incorrectly - this should make more sense.
 VCO_Output_Input.png 
ELOG V3.1.3-