40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 3 of 29  Not logged in ELOG logo
Entry  Tue May 14 18:13:21 2019, anchal, DailyProgress, Computers, Added threshold channels in autolocker and fastmon rms monitor screenshots.zip
Entry  Mon May 13 19:12:56 2019, anchal, DailyProgress, Other, Set experiment for 2.6 mW transmission from cavities. 
Entry  Mon May 13 16:25:14 2019, anchal, Summary, Computers, Converted all PSL_Lab links to CTN links CorrectLinks.zip
    Reply  Mon May 13 16:54:15 2019, awade, Summary, Computers, Converted all PSL_Lab links to CTN links 
Entry  Fri May 10 15:50:09 2019, anchal, Summary, Computers, modbus shifted to a git repo for version control 
Entry  Thu May 9 12:16:55 2019, anchal, Summary, FSS, Saving PDH error signal values 
Entry  Wed Apr 24 16:01:55 2019, anchal, DailyProgress, FSS, Time series and spectrum analysis of RFout of SCavReflRFPD near resonance South_Cavity_Reflection_RFout_Time_Series_Analysis.pdfSouth_Cavity_Reflection_RFout_Spectrum_Analysis.pdf
    Reply  Fri Apr 26 14:34:03 2019, anchal, DailyProgress, FSS, Time series and spectrum analysis of RFout of SCavReflRFPD near resonance 
       Reply  Sun Apr 28 22:31:39 2019, rana, DailyProgress, FSS, RF beats 
          Reply  Tue Apr 30 18:07:49 2019, anchal, DailyProgress, FSS, Spectrum of RFout from South Cavity Reflection RFPD SCavReflRFoutSpecAnalysis.pdf
             Reply  Wed May 8 20:03:43 2019, anchal, DailyProgress, FSS, FSS PDH Error Signal on South Path is in good health SCavPDHError20190508.pdfCavity_Refl_RFPD_TI_After_Modifications.pdf
Entry  Mon May 6 20:49:03 2019, anchal, Notes, PLL, Using PLL for Frequency Noise Measurement 
Entry  Mon May 6 20:12:22 2019, Anjali, Summary, Equipment loan, Borrowed components 
Entry  Thu May 2 15:55:18 2019, anchal, DailyProgress, South Cavity, South Cavity Alignment Fixed 
Entry  Thu May 2 14:38:41 2019, anchal, DailyProgress, South Cavity, Corrected input polarization into South Cavity SCavPolOptimization.pdf
Entry  Wed May 1 18:45:47 2019, anchal, Notes, Other, To scale complete optical layout of CTN 
Entry  Thu Apr 25 20:24:27 2019, anchal, Summary, Electronics Equipment, Adjustable TTL Trigger Generator Box Adjustable_TTL_Trigger_Generator_Box.pdf
    Reply  Sun Apr 28 22:29:18 2019, rana, Summary, Electronics Equipment, should I use an OpAmp as a Comparator? 
       Reply  Tue Apr 30 18:55:06 2019, anchal, Summary, Electronics Equipment, Follow up on TTL Trigger generator box 
Entry  Wed Apr 17 10:40:54 2019, Koji, Summary, Equipment loan, Borrowing an IPA/Acetone glass bottoles CTN->OMC 
Entry  Sat Apr 13 16:23:30 2019, anchal, DailyProgress, FSS, South Cavity Reflection Path reset 
Entry  Fri Apr 12 11:43:33 2019, anchal, Notes, FSS, Photodiode C30642 doesn't has enough bandwidth! 
    Reply  Fri Apr 12 11:55:54 2019, Koji, Notes, FSS, Photodiode C30642 doesn't has enough bandwidth! 
       Reply  Fri Apr 12 18:00:59 2019, Koji, Notes, FSS, Photodiode C30642 doesn't has enough bandwidth! 
Entry  Mon Apr 8 19:19:02 2019, anchal, DailyProgress, FSS, South FSS problems 
    Reply  Tue Apr 9 14:35:30 2019, anchal, DailyProgress, FSS, South FSS problems 
       Reply  Wed Apr 10 16:34:55 2019, anchal, DailyProgress, FSS, South FSS problems South_EOM_Driver_TF_Measurements.jpgSouth_EOM_TF_Analysis.pdfNorth_EOM_TF_Analysis.pdf
          Reply  Wed Apr 10 19:05:29 2019, Ultraman, DailyProgress, FSS, South FSS problems 
Entry  Thu Apr 4 18:40:18 2019, anchal, DailyProgress, Mode matching, Re-aligned South Path 
    Reply  Fri Apr 5 19:28:56 2019, anchal, DailyProgress, Mode matching, Re-aligned South Path 
Entry  Wed Apr 3 16:23:26 2019, anchal, DailyProgress, PMC, Rehabilitation of PMCs 
    Reply  Thu Apr 4 15:33:34 2019, anchal, DailyProgress, PMC, Rehabilitation of PMCs 
Entry  Sat Mar 23 21:50:40 2019, anchal, Summary, Electronics Equipment, Power tripping incident and follow-up 
Entry  Tue Mar 19 16:39:20 2019, anchal, DailyProgress, FSS, Need to track down 60 Hz spike source in FSS 
Entry  Tue Feb 26 02:45:20 2019, anchal, Notes, Computers, Migrating epics channels from acromag1 to c3iocserver acromag.cmd
    Reply  Tue Mar 12 17:04:03 2019, anchal and awade, Summary, Computers, Migrating epics channels from acromag1 to c3iocserver 
       Reply  Sun Mar 17 18:28:06 2019, awade and anchal, Summary, Computers, Migrating epics channels from acromag1 to c3iocserver: killing acromag1 services 
Entry  Wed Jan 30 15:07:32 2019, awade, anchal, HowTo, FSS, Shot noise in FSS loops? 
    Reply  Fri Feb 1 14:59:01 2019, awade, anchal, HowTo, FSS, Noise tallies CTN_FSS_south_blockdiagram.pdf
       Reply  Fri Feb 1 20:20:11 2019, awade, HowTo, FSS, Modifying North FSS EOM path 
          Reply  Tue Feb 5 11:40:02 2019, awade, HowTo, FSS, Modifying South FSS boost 
             Reply  Tue Feb 5 20:39:52 2019, anchal, Summary, FSS, Complete model of TTFSS box with TF and crossover analysis FSS_Modified_Analysis.pdfFSS_Mod_Analysis.zip
                Reply  Wed Feb 6 19:13:06 2019, anchal, Summary, FSS, Complete model of TTFSS box with TF and crossover analysis FSS_Modified_Analysis.pdf
                   Reply  Wed Feb 6 21:30:24 2019, awade, Summary, FSS, Complete model of TTFSS box with TF and crossover analysis EOM_Vrms_FunctionOfLowerFrequencyBoundOfTF.pdfTTFSS_lisomodel_FSS_Mod_Analysis.ipynb.zip
                      Reply  Thu Feb 7 10:33:27 2019, anchal, Summary, FSS, Complete model of TTFSS box with TF and crossover analysis 
Entry  Wed Dec 19 17:47:02 2018, anchal, DailyProgress, TempCtrl, Cavity Temperature Sensor Circuit v1.1 48390116_529820604163457_2540948531154255872_n.jpg
    Reply  Mon Dec 24 16:52:26 2018, rana, DailyProgress, TempCtrl, Cavity Temperature Sensor Circuit v1.1 
       Reply  Tue Jan 29 17:47:14 2019, anchal, DailyProgress, TempCtrl, Cavity Temperature Sensor Breadboard Circuit Noise Analysis Cavity_Temperature_Sensor_Breadboard_Circuit_Noise.pdfBreadBoardCircuitNoiseAnalysis.zip
          Reply  Wed Jan 30 12:17:05 2019, rana, DailyProgress, TempCtrl, Cavity Temperature Sensor Breadboard Circuit Noise Analysis 
Entry  Mon Jan 28 10:56:49 2019, awade and anchal, DailyProgress, NoiseBudget, Noisebudget with Resonant Beat Note Photo Detector - Touching new lows BeatNoteJan25_2019_Iris.zip20190128_105844noiseBudget.pdf
Entry  Tue Jan 22 20:26:18 2019, awade, DailyProgress, TempCtrl, Running relay controller overnight on refcavs 
    Reply  Wed Jan 23 11:28:53 2019, awade, DailyProgress, TempCtrl, Correcting BN after running relay controller overnight on refcavs 
       Reply  Thu Jan 24 14:24:10 2019, awade, DailyProgress, TempCtrl, Custom implementation of PIDLocker script for finer control of intergration on cav heaters PIDLocker_cavcontrol.py.zip
          Reply  Fri Jan 25 10:46:24 2019, awade, DailyProgress, TempCtrl, PID locking of cavity heaters to BN PID_locking_GlitchAndRunAway_2019-01-25_at_10.50.19_AM.png
             Reply  Fri Jan 25 15:45:48 2019, anchal, DailyProgress, TempCtrl, PID locking of cavity heaters to BN 
Entry  Thu Jan 24 12:38:47 2019, anchal, DailyProgress, NoiseBudget, Beat Note Noise Spectrum after tuning FSS Loop PLLDarkNoiseandOLTF_Jan23_2019.pdfBeatNoteJan24_2019_Iris.zip20190125_150848noiseBudget.pdf
Entry  Wed Jan 23 18:13:48 2019, anchal and awade, DailyProgress, FSS, FSS Gain and Offset tuning 
Entry  Tue Jan 22 19:04:51 2019, anchal, DailyProgress, PLL, New Focus 1811-FC Dark noise Measurement NewFocus1811-FC_DarkNoiseSpectrum.pdfNewFocus1811-FCDarkNoiseSpectrum.ipynb.zipNewFocus1811-FC_DarkNoiseSpectrum_New.pdfNewFocus1811-FCDarkNoiseSpectrumNew.ipynb.zip
    Reply  Wed Jan 23 11:43:02 2019, awade, anchal, DailyProgress, PLL, New Focus 1811-FC Dark noise Measurement 
Entry  Mon Jan 21 19:01:11 2019, anchal, Notes, PLL, PLL Transfer Function and Noise Study 
Entry  Wed Jan 16 22:07:44 2019, awade, anchal, DailyProgress, PLL, PLL noise from the Marconi 2023A FG IMG_4875.JPGIMG_4877.JPG
    Reply  Fri Jan 18 13:10:02 2019, anchal, DailyProgress, PLL, PLL noise from the Marconi 2023A FG MarconiPLLNoiseAnalysis.pdfMarconi_PLL_Noise.zip
Entry  Fri Jan 4 19:17:00 2019, anchal, Summary, TempCtrl, Vacuum Can Temperature Sensors (AD590) transimpedance amplifier board test - RESULTS VacCanTemSensorTest_Time_Series_Data_1229716818_to_1229904318.pdfVCTemperatureSensorsTest.zip
    Reply  Thu Jan 17 11:55:12 2019, anchal, Summary, TempCtrl, Vacuum Can Temperature Sensors (AD590) transimpedance amplifier board noise test Vacuum_Can_Temperature_Sensor_Transimpedance_Circuit_Noise_Analysis.pdfVCTMPSNS_Noise.zip
Entry  Fri Jan 4 19:04:29 2019, awade, DailyProgress, RFAM, Time to look at RF AM and RIN 
    Reply  Wed Jan 9 17:25:38 2019, anchal, DailyProgress, RFAM, Time to look at RF AM and RIN RIN_DBN_Coherence_Measurement.pdf
       Reply  Wed Jan 9 19:05:56 2019, anchal, DailyProgress, RFAM, Time to look at RF AM and RIN 
          Reply  Thu Jan 10 11:38:53 2019, awade, DailyProgress, RFAM, Time to look at RF AM and RIN 
             Reply  Thu Jan 10 17:30:24 2019, anchal, DailyProgress, RFAM, Time to look at RF AM and RIN 
                Reply  Thu Jan 10 18:52:20 2019, anchal, DailyProgress, RFAM, Time to look at RF AM and RIN 
                   Reply  Sat Jan 12 13:11:02 2019, awade, DailyProgress, RFAM, Time to look at beatnote after RF AM and RIN tuneup 
                      Reply  Wed Jan 16 11:07:41 2019, anchal, DailyProgress, NoiseBudget, Beatnote after RF AM and RIN tuneup LaserPowerNoise_to_BNFreqNoise_TF.pdfIN_to_BN_TF.zipTransmission_RIN_Jan15_2019.pdfRIN_Measurement_20190115.zip20190116_130937noiseBudget.pdf
    Reply  Thu Jan 10 14:19:46 2019, anchal, DailyProgress, RFAM, Time to look at RF AM and RIN 
Entry  Fri Jan 4 16:42:28 2019, anchal, Summary, NoiseBudget, Latest noisebudget update. Jan03_2019_BNnoise__Iris.pdf20190104_171447noiseBudget.pdf
Entry  Wed Dec 26 14:09:29 2018, anchal, Notes, EPICS, ws1 unable to read/write on some EPICS channels 
Entry  Tue Dec 25 11:45:15 2018, anchal, DailyProgress, TempCtrl, Vacuum Can Temperature Sensors (AD590) transimpedance amplifier board test 7x
Entry  Mon Dec 17 22:13:03 2018, anchal, DailyProgress, TempCtrl, Proposed circuit for cavity temperature sensor Part 2 Cavity_Temperature_Sensor_Calculations.zipCavTempSensorAcromagChannels.pdf
    Reply  Wed Dec 19 11:01:00 2018, awade, DailyProgress, TempCtrl, Proposed circuit for cavity temperature sensor Part 2 
       Reply  Wed Dec 19 14:00:55 2018, anchal, DailyProgress, TempCtrl, Proposed circuit for cavity temperature sensor Part 2 
Entry  Thu Dec 13 15:34:33 2018, anchal, DailyProgress, TempCtrl, Proposed circuit for cavity temperature sensor AD8429_Input_Reffered_Noise_with_RTD_LTSpice.pdfInstrumentationAmplifierNoiseAnalysis.pdfLTSpiceandLISOcodesInsAmpNoiseAnalysis.zipRTD_Current_Source.pdf
Entry  Mon Dec 10 15:40:51 2018, anchal, Summary, TempCtrl, Prototype results for transimpedance circuit for Vacuum Can Temperature Sensor VCTS_TIA_Prototype.pdf48368130_207018923542708_4747446313996517376_n.jpg
Entry  Fri Dec 7 11:26:30 2018, awade, Misc, DAQ, Frame builder back up 
Entry  Tue Dec 4 15:05:56 2018, anchal, DailyProgress, TempCtrl, Optimal circuit for transimpedance of temperature sensor for Vacuum Can VacCanTemSensorTIAOpampOptimization.pdfAD590TIAmp.zip
Entry  Mon Dec 3 10:44:19 2018, anchal, Notes, TempCtrl, Plan of action for installing new heater shield and temperature sensors 
Entry  Wed Nov 28 10:42:47 2018, anchal, Notes, TempCtrl, Temperature control efforts in last few days Screenshot_from_2018-11-26_16-32-54.png
    Reply  Wed Nov 28 19:50:20 2018, rana, Notes, TempCtrl, Temperature control efforts in last few days 
Entry  Thu Nov 22 12:49:35 2018, anchal, DailyProgress, TempCtrl,  
Entry  Wed Nov 21 19:33:23 2018, awade, Misc, Electronics Equipment, SR785 (SN46950) 
Entry  Wed Nov 21 17:54:00 2018, anchal, DailyProgress, TempCtrl, Notes about Cavity Heater PID 
Entry  Tue Nov 20 17:31:13 2018, anchal, DailyProgress, Other, Precav Beatnote Freq counter and PID optimization 
Entry  Sun Nov 18 18:50:39 2018, anchal, Summary, South Cavity, South Path up and running again SouthOptimizedPath.pdf
Entry  Mon Nov 12 11:53:50 2018, anchal, Notes, optic, Changed half waveplate angle after South EAOM 
Entry  Tue Nov 6 13:41:04 2018, anchal, Summary, PMC, PMC installed on South Path South_PMC_Alignment.jpgNorthAndSouthPMCServoCardsonRack.jpg9VConverter.jpgFGMixersLPFandSplitters.jpg
Entry  Fri Oct 19 17:05:10 2018, anchal, Summary, NoiseBudget, Summary of present noise budget 20181019_154643noiseBudget.pdf
ELOG V3.1.3-