40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 38 of 52  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  1190   Tue Jun 4 18:02:26 2013 taraDailyProgressRefCavbeam directed to 2nd refcavThe beam is sent to 2nd cavity (RCAV).
The beam is mode match roughly, since there
is no PMC, the exact beam size is hard to
  
  44   Wed Feb 3 13:05:26 2010 FrankLaserRefCavbeam pointing @ refvacmeasured the beam pointing caused by driving
the AOM frequency modulation input. data
is uncalibrated so far, just a screenshot
 pointing.jpg 
  844   Sun Feb 26 17:40:43 2012 taraDailyProgressopticbeam realignment after new seismic stack installation I'm trying to re-align the beams to the
cavities. Due to the new RTV springs for
the seismic stack, the cavities' natural
 IMG_0373.JPGIMG_0374.jpg 
  845   Mon Feb 27 10:56:43 2012 taraDailyProgressopticbeam realignment after new seismic stack installation I realigned ACAV and found TEM00, but now
the transmitted beam is completely missed
the opening on the insulation, it is off
  
  819   Fri Feb 10 23:47:22 2012 Tara, FrankDailyProgressBEATbeam splitter mount replacedwe replaced the mount for the combining
beam splitter in the beat setup as it caused
a large, broadband peak in the spectrum around
  
  1321   Mon Sep 2 03:38:27 2013 taraDailyProgressNoiseBudgetbeatIt's a quiet night, so I went down the
lab to measure the beat signal. We are getting
close. I think I have to review my noise
 zoom_beat_2013_09_02.pngbeat_2013_09_02.pngnb_short_cav.figzoom_beat_2013_09_02.png 
  1327   Sat Sep 7 04:29:32 2013 taraDailyProgressNoiseBudgetbeatShort note from tonight measurement:
1) scattered bump from dc to 100Hz
is mostly from seismic. It is worse during
  
  507   Tue Feb 22 21:57:02 2011 frank, taraDailyProgressBEATbeat Today, we found out that at high frequency,
the limiting noise source is probably electronics
noise might be from the Universal PDH box.
 beat_2011_02_22.png 
  509   Wed Feb 23 01:47:15 2011 frankDailyProgressBEATbeat you have to be a bit more precisely
fro points 2 and 3, e.g. no one knows what
you mean as    "PDH" gain as you
  
  560   Fri Apr 1 01:58:25 2011 taraNotesBEATbeat and UPDH gain on ACAV loopI checked electronic noise, of the UPDH
box while tuning its gain, to understand
why the beat signal gets higher when the
 7x 
  564   Mon Apr 4 19:48:51 2011 taraNotesBEATbeat and UPDH gain on ACAV loopI check the noise projection from RCAV's
error signal. It is still lower than the
beat frequency. So the limiting noise source
 rcav_errnoise.png 
  565   Tue Apr 5 22:32:08 2011 taraNotesBEATbeat and UPDH gain on ACAV loop I made sure that the gain setup
for ACAV's servo was not too high and caused
instability in the loop. The beat was not
 errnoise.pngnoise_prj_beat.png 
  1231   Tue Jul 9 19:35:20 2013 taraDailyProgressopticbeat board is backI installed the beat board back behind
the cavities. I still have not finished aligning
both beams to the 1811. 
  
  73   Mon Feb 22 18:58:23 2010 Tara ChalermsongsakLaserRefCavbeat frequency between transmitted beams Today  we finally see the beat
between transmited beams from Ref Cavity
and A Cavity.  Now we are trying to
 02.TIF 
  858   Fri Mar 2 23:37:36 2012 taraDailyProgressBEATbeat is back Beat signal is back now, but we have
not measured the spectrum yet since the temperature
is still drifting fast (10kHz/ min). We plan
  
  860   Sat Mar 3 14:53:51 2012 ZachDailyProgressBEATbeat is back

    

       
            
 disco.png 
  861   Sat Mar 3 17:50:45 2012 taraDailyProgressBEATbeat is backNO!! no dance
party for you because you didn't return our
  
  862   Sat Mar 3 18:07:15 2012 ZachDailyProgressBEATbeat is backAnd I stole one of your air dusters :-)
There used to be TWO label makers
in the ATF---one of which looked like that
  
  863   Sun Mar 4 00:45:26 2012 frank, taraDailyProgressBEATbeat is backBeat is back.
The beat signal( with the new softer
springs) is measured and compared with the
 beat_2012_02_03.png 
  864   Mon Mar 5 16:29:50 2012 frank, taraDailyProgressBEATbeat is backAs mentioned in the previous entry that
the in loop noise is higher than before.
We investigate what might be the causes.
 relax.JPG 
  870   Tue Mar 6 20:48:47 2012 frank, taraDailyProgressBEATbeat is backAfter debugging the RCAV loop, we measured
the beat signal again.  We still cannot
reach coating thermal noise, the noise floor
 beat_2012_02_22.png 
  674   Mon Sep 12 01:21:14 2011 taraDailyProgressBEATbeat layoutNew beat layout, both paths travel with
the same distance before combining at the
beam splitter. I'll try if this layout work
 beat_2011_09_12.png 
  677   Tue Sep 13 20:54:11 2011 taraDailyProgressBEATbeat layout 
 Beat path was setup. Beat RFPD
sees the signal around 125 MHz. Beat measurement
  
  678   Wed Sep 14 19:17:19 2011 frank, paul, taraDailyProgressBEATbeat layout Beat signal from double cavities
in the same chamber was measured. At DC to 100Hz, it seems
 beat_2011_09_14.pngSnapshot_2011-09-14_19-39-37.png 
  449   Thu Jan 20 11:32:40 2011 taraPhotosBEATbeat layout with 3" heightThe picture is posted on the board outside
the lab as well.
 beat.jpg 
  1393   Tue Dec 31 19:33:47 2013 taraSummaryNoiseBudgetbeat measurementI got a chance to measure beat measurement.
The noise budget is updated and contains
all dominant noise traces.
 beat_2013_12_24.pngTTFSS.pngRCAV_OLG.pngACAV_OLGTF.png 
  506   Mon Feb 21 20:15:14 2011 frank, taraDailyProgressBEATbeat measurement b/w cable delay and PLLToday we compared beat noise measured
from phase lock loop(PLL) and cable delay
technique (CD.)
 6x 
  966   Fri May 18 03:56:22 2012 taraDailyProgressBEATbeat measurement updateThe beat signal is getting better at lower
frequency, there is no obvious scattering
bump around 80 Hz anymore. It is possible
 beat_2012_05_18.pngcompare.pngzoom.png 
  967   Fri May 18 18:44:38 2012 taraDailyProgressBEATbeat measurement updateI'm trying to fix the mechanical peaks
in the beat signal. The work is still in
progress.
  
  1009   Sat Jun 30 05:01:04 2012 taraDailyProgressBEATbeat measurement with 2mW input powerI changed the power input from 1mW to
2mW for both cavities and measure the beat
signal. From the measured results, there
 beat_2012_06_29_3.png 
  353   Fri Sep 10 12:22:04 2010 taraDailyProgressBEATbeat noise measurementPlot from yesterday measurement. The new
result is in red. 
The data is measured from the feedback
 new_beat.png 
  391   Thu Nov 11 22:50:14 2010 taraDailyProgressBEATbeat noise measurementI
measured the beat note signal from two different
setup (f modulation) and plot the result
 psl_refcav_sio2_300K.pngdata.mat 
  1693   Sat Jul 30 19:08:08 2016 Antonio and AndrewDailyProgressBEATbeat note work and PLLSummary


Today we have worked reying
to improve the beat note signal in its amplitude.
We
  
  574   Mon Apr 11 18:20:02 2011 taraDailyProgressBEATbeat setup is backThe optics behind RCAV for beat measurement
are re-installed, with the new periscope.
I'm waiting for the temperature to settle.
 000_0019.jpg000_0020.jpg 
  286   Tue Aug 17 14:52:57 2010 FrankPhotos beat setup panorama picture incl beams   beat_panorama_small_with_beams3.jpg 
  290   Wed Aug 18 03:15:20 2010 ranaPhotos beat setup panorama picture incl beamsThe panorama is a good idea. We should
make it a mandatory step whenever we make
any change to the setup. 
  
  291   Wed Aug 18 12:19:17 2010 FrankPhotos beat setup panorama picture incl beamsi know the the asymmetry is not nice but
we made the first beat setup symmetric and
suffered a lot from the (former) little space
  
  459   Mon Jan 31 20:24:45 2011 frank, taraNotesBEATbeat signal down to 12.5 mHzThis morning I was able to measure the
beat noise down to 12.5 mHz. So I plot it
together with the noise budget here.
 beat_2011_01_30_lowf.png 
  463   Tue Feb 1 22:22:46 2011 frank, taraNotesBEATbeat signal down to 12.5 mHzWe measured beat noise from the frequency
counter(FC) instead of the feedback from
PLL.   The result is plotted below
 PLL_FC_good.png2011_02_01_log3.pngac_highpass.png2011_02_01_dat.matcode_2011_02_01.m 
  415   Wed Dec 1 22:07:05 2010 taraDailyProgressBEATbeat vs Power Input I measured the beat signal from 3
different power input levels, the signal goes down
 beat_2010_12_01.png2010_12_01.zip 
  882   Mon Mar 12 23:31:38 2012 frank, taraDailyProgressBEATbeat with floated table, air spring.We measured beat signal with the upgraded
seismic isolation system. It seems that we
are sitting on some scattering noise source
 beat_2012_03_12.png 
  878   Sat Mar 10 18:42:42 2012 taraDailyProgressBEATbeat- with air spring isolation  Beat measurement with new air springs
is measured with unfloated table (the N2
supply is empty). Good improvement can be
 beat_2012_03_10.pngbeat_2012_03_10.png 
  1808   Tue Jan 10 16:40:28 2017 yinziDailyProgressTempCtrlbeginning integration on temperature controlWe did some more hardware integration for
the temperature control loop yesterday. We
first added a new input channel and a new
 IMG_5302.JPGIMG_3021.JPGIMG_4369.JPG 
  184   Tue Jun 29 14:59:52 2010 FrankNotesNoiseBudgetbetter list of emissivity coefficientssource : http://www.omega.com/temperature/z/pdf/z088-089.pdf
 emission_coefficients.pdf 
  51   Fri Feb 5 20:37:06 2010 Tara ChalermsongsakLaserRefCavbetter pointing alignment After adjusting the mirror for reflecting
beam back to the AOM, the QPD signal shows
the better alignment. Before the voltage
  
  2533   Thu Feb 13 18:00:30 2020 anchalDailyProgressscatterblocked NF1811 with hex beam dumpI have blocked the unused output port of
the beam splitter before our beatnote detector
with a hex beam dump at (13,
  
  934   Tue Apr 24 22:07:10 2012 taraNotesLaserborrow NPRO from TNII borrow an NPRO from TNI. The model is
similar to what we have, but I think the
maximum power is 500mW (what we have is 100mW).
 IMG_0818.jpg 
  936   Wed Apr 25 10:13:55 2012 FrankNotesLaserborrow NPRO from TNIDon't forget to write an SOP for that laser
before using it. A few things changed recently
if you want to use the old SOP as an template.
  
  939   Wed Apr 25 15:15:03 2012 taraNotesLaserborrow NPRO from TNIDuly noted, I'll write the sop for this
one and put it on svn and wiki.

  
  68   Thu Feb 18 15:07:39 2010 FrankMiscLaserboth IR viewers missingso please bring it back - we are waiting
for it and can't go on without those... For
the future: if you take it, bring it back
  
ELOG V3.1.3-