40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 34 of 52  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  945   Fri Apr 27 10:30:57 2012 FrankNotesAcousticsacoustic damping from plexiglas and sandwich structuressandwich structures using plexiglas : "Damped
Windows for Aircraft Interior Noise Control"
http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.79.9176
  
  944   Fri Apr 27 08:57:38 2012 steveNotesPurchasesvibration isolators (table legs) in 40mThose are the ones we are using right now
and break after some while because they are
too old (the rolling rubber diaphragm is
  
  943   Fri Apr 27 08:46:24 2012 FrankNotesopticwindows for vacuum chambercavity mirrors are parallel to the end
surface of the chamber (not completely, but
pretty close; changes every time we touch
  
  942   Thu Apr 26 16:57:33 2012 steveNotesPurchasesvibration isolators (table legs) in 40m

    

       
            
  
  941   Thu Apr 26 12:15:13 2012 FrankNotesPurchasesvibration isolators (table legs)The price for the custom made legs are
$ 9295, and for the standard 16" are
$ 3710
 Quotation_1058227_for_CALIFORNIA.pdf 
  940   Thu Apr 26 08:35:57 2012 steveNotesopticwindows for vacuum chamber

    

       
            
  
  939   Wed Apr 25 15:15:03 2012 taraNotesLaserborrow NPRO from TNIDuly noted, I'll write the sop for this
one and put it on svn and wiki.

  
  938   Wed Apr 25 10:44:29 2012 FrankNotesopticwindows for vacuum chamberI don't know how you gonna make the knife
edge on the 10" flange of centered and
wedged! If you put the small CF flanges on
  
  937   Wed Apr 25 10:23:34 2012 FrankNotesPurchasesvibration isolators (table legs)We have "Pneumatic Vibration Isolators
with Automatic Re-leveling". Height
is 16in from top to bottom, so that would
  
  936   Wed Apr 25 10:13:55 2012 FrankNotesLaserborrow NPRO from TNIDon't forget to write an SOP for that laser
before using it. A few things changed recently
if you want to use the old SOP as an template.
  
  935   Tue Apr 24 22:10:45 2012 taraNotesElectronics Equipmentmodified UPDH[Frank, Tara]
We
checked the input referred noise of the UPDH
 zoom.png 
  934   Tue Apr 24 22:07:10 2012 taraNotesLaserborrow NPRO from TNII borrow an NPRO from TNI. The model is
similar to what we have, but I think the
maximum power is 500mW (what we have is 100mW).
 IMG_0818.jpg 
  933   Mon Apr 23 22:06:14 2012 taraNotesPurchasesvibration isolators (table legs)I'm looking for the new table legs. The
height will be 13.5". The plate that
connects to the table will have 3 holes,
 IMG_0805.jpgIMG_0809.jpg 
  932   Mon Apr 23 16:52:16 2012 taraNotesopticwindows for vacuum chamberI asked Steve about the choices, he thought
the Thorlabs window should be ok for us.
      What
  
  931   Sun Apr 22 23:09:38 2012 taraNotesopticwindows for vacuum chamberFor small window option, I can either have
it made from scratch ( based on LIGO's drawing)
or buy the commercial windows from Thorlabs.
  
  930   Sun Apr 22 22:10:17 2012 taraNotesDocumentationProposal is on SVNThe problem is fixed, I just deleted my
local folder, check outed from the svn. Now
when I commit the subversion, it shows up
  
  929   Sat Apr 21 00:55:00 2012 frank, taraDailyProgressBEATBeat measurement updateWe measured the beat after a few changes
in the setup (modulation index, air spring,
small enclosure around the beat). We update
 beat_2012_04_20.png 
  928   Thu Apr 19 21:10:59 2012 FrankNotesDrawingsshort cavitiesdetailed CAD drawings for the short cavities,
mirrors, cavity mount, radiation shields,
adapter plates and modified top stack 
  
  927   Thu Apr 19 19:58:19 2012 taraNotesDocumentationProposal is on SVNThe proposal for CTN lab is on SVN.
The original folder was /CTNlab/docs/Proposal.
 
  
  926   Thu Apr 19 03:12:23 2012 taraNotesopticwindows for vacuum chamber 
I'm searching DCC for window/viewport
examples. The following drawings give me
  
  925   Wed Apr 18 23:53:01 2012 Frank, TaraDailyProgressFoamsimple insulating boxto test how much insulation we need to
reduce our acoustic noise (or air currents)
problem we've added a simple aluminum-foil
 IMG098.jpg 
  924   Wed Apr 18 02:38:59 2012 taraNotesEOMChange modulation depth for 14.75MHz EOMI changed the attenuator to -1dBm. From
a quick measurement, there's no improvement
in the beat signal at high frequency. Any
  
  923   Wed Apr 18 00:49:07 2012 taraDailyProgressopticvibration damping on opticsI planned to measure the beat at night
with the air springs activated, but the power
went out around 11:45 pm. I think the temperature
  
  922   Tue Apr 17 19:51:54 2012 taraNotesopticwindows for vacuum chamberIf we go with plan2,
1)window and flange

    I think the window size
 IMG_0757.jpg 
  921   Mon Apr 16 22:02:08 2012 taraDailyProgressopticvibration damping on opticsI forgot to change the code to disable
the air springs, now the seismic coupling
makes more sense.
 beat_2012_04_15_fixed.png 
  920   Mon Apr 16 18:17:05 2012 Frank, TaraSummaryNoiseBudgetmechanical resonancesI was told at JILA that anything less than
3/4" thick is lame.
This place has thick stuff:
  
  919   Mon Apr 16 16:21:01 2012 taraNotesopticwindows for vacuum chamberI'm checking the properties/prices/availability
of window for the vacuum chamber.
 
  
  918   Mon Apr 16 15:35:15 2012 Frank, TaraSummaryNoiseBudgetmechanical resonanceswe mapped the mechanical resonances in
our system using two techniques :

    tapping each optical component
 beatboard_resonances.jpgPDH.jpg 
  917   Mon Apr 16 03:42:39 2012 FrankNotesPurchasesacoustic insulationordered thin (1in) t-channel aluminum frame
parts from mcmaster (similar to bosch framing,
but cheaper, link)
  
  916   Mon Apr 16 02:20:58 2012 taraDailyProgressopticvibration damping on opticsI measured beat signal, after damping most
of the optics, realigning the beams to the
cavities, measured the slope of error signals
 beat_2012_04_15.pngbeat_2012_04_15.png 
  915   Sat Apr 14 06:03:23 2012 frank,taraDailyProgressopticvibration damping on optics We are damping most of the optics
with rubber cones. There are a few peaks
that we still could not find their origins. 
 IMG_0744.jpgIMG_0742.jpg 
  914   Sat Apr 14 01:10:48 2012 taraNotesEOMChange modulation depth for 14.75MHz EOMI increased the power to the 14.75MHz EOM
from 0.5 dBm to 3.5 dBm. This was done by
changing the attenuator from -6dBm to -3dBm.
  
  913   Fri Apr 13 13:35:37 2012 Tara, FrankSummaryNoiseBudgetPDH readout noise level verificationwe re-checked the electronic noise level
for each PDH loop and also checked how the
noise level rises with a shot noise limited
 SN_RCAV.pngSN_ACAV.png 
  912   Fri Apr 13 03:15:12 2012 koji,frank,taraDailyProgressopticvibration damping on opticsWe tried to damp mechanical peaks from
each optics. For now, by putting a rubber
piece on a mirror mount can suppress mechanical
 IMG_0731.jpgdamped.png 
  911   Thu Apr 12 22:22:12 2012 frank, taraDailyProgressNoiseBudgetElectronic noise + shot noise verificationWe measured shot noise level with white
light source. The noise level is slightly
off from shot noise calculation in the noise
  
  910   Thu Apr 12 13:58:17 2012 FrankDailyProgressNoiseBudgetlow frequency noise source   HEPA.png 
  909   Wed Apr 11 20:30:50 2012 frank, taraDailyProgressNoiseBudgetElectronic noise verification  We are checking the noise contribution
from electronics readout of our system to
get better noise budget estimation. We added
 beat_2012_04_11.png 
  908   Wed Apr 11 14:31:52 2012 FrankDailyProgressNoiseBudgetlow frequency noise sourcei have identified part of the low frequency
noise source from yesterdays measurement
- air fluctuations. We still had the HEPA
  
  907   Wed Apr 11 14:22:47 2012 FrankNotesLaserlaser shutdownpulling the switch for one of the HEPA
fans triggered the laser and put it in standby
mode - turned laser back on
  
  906   Wed Apr 11 02:44:29 2012 frank, taraDailyProgressopticbad PBSUpdate, beat measurement after several
optics replacement. Peaks around 10 Hz, 35
Hz show up this time. 
 beat_2012_04_10.png 
  905   Tue Apr 10 00:50:56 2012 frank, taraDailyProgressopticbad PBSWe noticed wide angle scattered light behind
the PBS in front of RCAV. The scattering
source is probably the curved mirror behind
  
  904   Mon Apr 9 23:05:44 2012 taraDailyProgressSeismicSeismic coupling from curtain frame to beatTing's code for new coating thermal noise
is attached. This is the code used for the
calculation in their paper (not published
 brownian_mult.m.zip 
  903   Sun Apr 8 23:35:05 2012 taraDailyProgressSeismicSeismic coupling from curtain frame to beat  I used ciplot command to plot the
noise budget with confidence region. 
 beat_ciplot.pngbeat_ciplot.png 
  902   Fri Apr 6 01:36:39 2012 Tara, FrankSummaryNoiseBudgetACAV loop changessummary of all changes made and more detailed
plots will be posted soon, so check back
later 
  
  901   Fri Apr 6 01:07:47 2012 taraDailyProgressNoiseBudgetThermoelastic noise from substrate I corrected the code for substrate thermoelastic
noise (TE) in my noise budget. The substrate
thermoelastic of 8 inch cavity will not be
 corrected.pngbeat_145in.png 
  900   Fri Apr 6 01:03:01 2012 frank, taraDailyProgressBEATground loop problemWe fixed the ground loop problem in ACAV
setup and got rid of most of the harmonic
lines in beat signal. 
 beat_2012_04_05.png 
  899   Fri Apr 6 00:34:28 2012 ranaHowToNoiseBudgetscattered light huntingHow
to find parasitic scatterers by
the GEO600 gang.
  
  898   Wed Apr 4 23:58:43 2012 taraNotesNoiseBudgetthermal noise from spacer + support Following the calculation from Kessler,
I estimated brownian noise from the spacer
and the o ring support from our setup. From
 beat_nb.png 
  897   Wed Apr 4 18:57:11 2012 ranaDailyProgressSeismicSeismic coupling from curtain frame to beathttp://lmgtfy.com/?q=matlab+ciplot   
  896   Tue Apr 3 20:56:10 2012 frank, taraDailyProgressSeismicSeismic coupling from curtain frame to beatWe measured the beat signal after we fixed
the wiring problem. We are close to what
we had before, but we still have a scattering
 beat_2012_04_03.png 
ELOG V3.1.3-