40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 2 of 29  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Fri Feb 12 12:46:38 2010, Tara Chalermsongsak, Laser, Laser, a picture of beam path on the optic bench psl_full_beam.jpg
Entry  Tue Feb 16 19:33:53 2010, Frank, Laser, Laser, several shutdowns the last days 
Entry  Wed Feb 17 15:40:04 2010, Frank, Laser, Laser, old 100mW NPRO 
Entry  Thu Feb 18 15:07:39 2010, Frank, Misc, Laser, both IR viewers missing 
Entry  Fri Feb 19 00:31:40 2010, Frank, Laser, Laser, 100mW lightwave NPRO slope NPRO_slope_2010-02-19.png
Entry  Fri Feb 19 18:23:24 2010, Tara Chalermsongsak, Laser, RefCav, alignment for measuring beat between 2 cavities 
Entry  Mon Feb 22 11:25:51 2010, Frank, Laser, Laser, laser fault again 
Entry  Mon Feb 22 16:21:43 2010, Frank, Tara, Laser, RC noise, both cavities locked, optimizing beat signal 
Entry  Mon Feb 22 18:58:23 2010, Tara Chalermsongsak, Laser, RefCav, beat frequency between transmitted beams 02.TIF
Entry  Tue Feb 23 20:13:00 2010, Tara Chalermsongsak, Laser, RefCav, successfully use ifr2023 to track the frequncy drift of the beat 02_23_2010.pdf
    Reply  Wed Feb 24 11:58:20 2010, rana, Laser, RefCav, successfully use ifr2023 to track the frequncy drift of the beat 
Entry  Wed Feb 24 19:40:25 2010, Tara Chalermsongsak, Laser, RC noise, calibrating ifr2023 calibration_feb_24.png
Entry  Wed Feb 24 20:07:00 2010, Tara Chalermsongsak, Laser, RC noise, RC frequency noise rf_noise_feb24_2010.png
Entry  Thu Feb 25 19:03:59 2010, Tara Chalermsongsak, Laser, RC noise, Noise floor from PD and SR560 noise_floor.png
Entry  Fri Feb 26 11:40:47 2010, Frank, Computing, DAQ, acav VME crate stopped working 
Entry  Fri Feb 26 15:15:56 2010, Tara Chalermsongsak, Laser, RC noise, quarter wave plate added/power from Ref and A Cavs measured 
Entry  Mon Mar 1 17:52:46 2010, Tara Chalermsongsak, Laser, RC noise, New Result Mar01_RCnoise.png
Entry  Sun Feb 28 23:53:21 2010, rana, Laser, RC noise, Noise Budget rcnb.png
    Reply  Mon Mar 1 22:39:39 2010, rana, Laser, RC noise, Noise Budget 
Entry  Wed Mar 3 08:46:26 2010, rana, Laser, RC noise, Noise as measured by the 40m MC 
Entry  Wed Mar 3 15:59:10 2010, Tara Chalermsongsak, Laser, RC noise, Noise from function generator Noise.pdfNoise.fig
Entry  Thu Mar 4 19:44:08 2010, Tara Chalermsongsak, Laser, RC noise, Noise from VCO Noise20100304.jpg
    Reply  Fri Mar 5 00:34:09 2010, Frank, Laser, RC noise, Noise from VCO 
       Reply  Fri Mar 5 14:40:21 2010, Frank, Laser, RC noise, Noise from VCO irf2023_@80Mhz.png
Entry  Thu Mar 11 22:45:58 2010, Tara Chalermsongsak, Laser, RC noise, VCO f noise VCO_noise.png
Entry  Tue Mar 23 00:26:43 2010, Frank, Tara, Misc, RefCav, ongoing work 
Entry  Tue Mar 23 21:17:56 2010, Frank, Tara, Misc, RefCav, foam cut & partly assembled 
Entry  Thu Mar 25 13:05:59 2010, Frank, Misc, RefCav, all parts baked 
Entry  Mon Mar 29 17:46:41 2010, Frank, Tara, Misc, RefCav, assembled new vacuum chamber 
Entry  Wed Mar 31 20:46:22 2010, Frank, Misc, RefCav, ion pumps 
Entry  Thu Apr 1 15:38:38 2010, Frank, Misc, DAQ, RT DAQ equipment arrived 
Entry  Fri Apr 2 00:35:00 2010, Frank, Misc, RefCav, new chamber almost ready 100_0692.JPG
Entry  Tue Apr 6 18:39:04 2010, Tara Chalermsongsak, Laser, RefCav, Calculation for higher order mode's frequency 1.png
    Reply  Wed Apr 7 12:30:47 2010, rana, Laser, RefCav, Calculation for higher order mode's frequency 
Entry  Wed Apr 7 18:29:16 2010, Tara Chalermsongsak, Laser, RefCav, Calculation for higher order mode's frequency 1.png
Entry  Fri Apr 9 21:34:15 2010, Frank, Computing, DAQ, new RT system 
Entry  Sun Apr 11 21:04:08 2010, Frank, Misc, RefCav, heating power requirement 
Entry  Mon Apr 12 10:57:33 2010, Tara Chalermsongsak, Laser, Laser, Correction for higher order mode frequency 3.png
Entry  Mon Apr 12 11:04:15 2010, Tara Chalermsongsak, Laser, Laser, PSL layout for new setup psl_layout_04_11_10.png
Entry  Tue Apr 13 00:25:52 2010, Frank, Computing, DAQ, new RT frontend 
    Reply  Tue Apr 13 14:50:39 2010, Frank, Computing, DAQ, new RT frontend 
Entry  Tue Apr 13 18:23:41 2010, Tara Chalermsongsak, Electronics, , TF of PDH Box tf_PDH_04_09.pngtf_PDH_04_09_phi.png
Entry  Thu Apr 15 16:42:32 2010, Frank, Electronics, RefCav, AD590 readout-box modified 
Entry  Fri Apr 16 10:45:04 2010, Tara Chalermsongsak, Electronics, , Control Loop for PSL psl5_fig.pnglinpsl5.m
Entry  Wed Apr 21 15:21:52 2010, Tara Chalermsongsak, Electronics, , TF of PDH Box 2010_04_20_bode_com.png
    Reply  Wed Apr 21 15:39:46 2010, rana, Electronics, , TF of PDH Box 
Entry  Sun May 2 19:18:36 2010, Frank, Misc, RefCav, reference cavity moved to new chamber 
Entry  Mon May 3 15:47:58 2010, Tara Chalermsongsak, Electronics, , TF of PDH Box TF_5_3.png
Entry  Tue May 4 03:40:00 2010, rana, Laser, RC noise, updated noise budget rc_sio2_300.pdf
Entry  Thu May 6 00:05:29 2010, Frank, Jan, Computing, RC noise, comsol/matlab model 
Entry  Thu May 6 11:01:03 2010, Frank, Misc, RC noise, model now in the svn 
Entry  Fri May 7 15:51:43 2010, Frank, Misc, RefCav, updated schematic for new setup refcav-setup_v1.png
Entry  Mon May 10 00:29:04 2010, Frank, Misc, RefCav, ion pump current still too high 
Entry  Tue May 11 22:26:34 2010, Tara Chalermsongsak, Laser, Laser, Beam waist measurement beamwaist.png
Entry  Wed May 12 22:10:13 2010, Tara Chalermsongsak, Laser, Laser, Beam waist measurement fit.png
Entry  Thu May 13 13:41:32 2010, Tara Chalermsongsak, Laser, Laser, mode matching from laser to PMC 
Entry  Thu May 13 20:56:57 2010, Frank, Laser, Laser, 100mW NPRO problems 
ELOG V3.1.3-