Entry  Tue Mar 19 16:39:20 2019, anchal, DailyProgress, FSS, Need to track down 60 Hz spike source in FSS 
Entry  Sat Mar 23 21:50:40 2019, anchal, Summary, Electronics Equipment, Power tripping incident and follow-up 
Entry  Wed Apr 3 16:23:26 2019, anchal, DailyProgress, PMC, Rehabilitation of PMCs 
    Reply  Thu Apr 4 15:33:34 2019, anchal, DailyProgress, PMC, Rehabilitation of PMCs 
Entry  Thu Apr 4 18:40:18 2019, anchal, DailyProgress, Mode matching, Re-aligned South Path 
    Reply  Fri Apr 5 19:28:56 2019, anchal, DailyProgress, Mode matching, Re-aligned South Path 
Entry  Mon Apr 8 19:19:02 2019, anchal, DailyProgress, FSS, South FSS problems 
    Reply  Tue Apr 9 14:35:30 2019, anchal, DailyProgress, FSS, South FSS problems 
       Reply  Wed Apr 10 16:34:55 2019, anchal, DailyProgress, FSS, South FSS problems South_EOM_Driver_TF_Measurements.jpgSouth_EOM_TF_Analysis.pdfNorth_EOM_TF_Analysis.pdf
          Reply  Wed Apr 10 19:05:29 2019, Ultraman, DailyProgress, FSS, South FSS problems 
Entry  Fri Apr 12 11:43:33 2019, anchal, Notes, FSS, Photodiode C30642 doesn't has enough bandwidth! 
    Reply  Fri Apr 12 11:55:54 2019, Koji, Notes, FSS, Photodiode C30642 doesn't has enough bandwidth! 
       Reply  Fri Apr 12 18:00:59 2019, Koji, Notes, FSS, Photodiode C30642 doesn't has enough bandwidth! 
Entry  Sat Apr 13 16:23:30 2019, anchal, DailyProgress, FSS, South Cavity Reflection Path reset 
Entry  Wed Apr 17 10:40:54 2019, Koji, Summary, Equipment loan, Borrowing an IPA/Acetone glass bottoles CTN->OMC 
Entry  Thu Apr 25 20:24:27 2019, anchal, Summary, Electronics Equipment, Adjustable TTL Trigger Generator Box Adjustable_TTL_Trigger_Generator_Box.pdf
    Reply  Sun Apr 28 22:29:18 2019, rana, Summary, Electronics Equipment, should I use an OpAmp as a Comparator? 
       Reply  Tue Apr 30 18:55:06 2019, anchal, Summary, Electronics Equipment, Follow up on TTL Trigger generator box 
Entry  Wed May 1 18:45:47 2019, anchal, Notes, Other, To scale complete optical layout of CTN 
Entry  Thu May 2 14:38:41 2019, anchal, DailyProgress, South Cavity, Corrected input polarization into South Cavity SCavPolOptimization.pdf
Entry  Thu May 2 15:55:18 2019, anchal, DailyProgress, South Cavity, South Cavity Alignment Fixed 
Entry  Mon May 6 20:12:22 2019, Anjali, Summary, Equipment loan, Borrowed components 
Entry  Mon May 6 20:49:03 2019, anchal, Notes, PLL, Using PLL for Frequency Noise Measurement 
Entry  Wed Apr 24 16:01:55 2019, anchal, DailyProgress, FSS, Time series and spectrum analysis of RFout of SCavReflRFPD near resonance South_Cavity_Reflection_RFout_Time_Series_Analysis.pdfSouth_Cavity_Reflection_RFout_Spectrum_Analysis.pdf
    Reply  Fri Apr 26 14:34:03 2019, anchal, DailyProgress, FSS, Time series and spectrum analysis of RFout of SCavReflRFPD near resonance 
       Reply  Sun Apr 28 22:31:39 2019, rana, DailyProgress, FSS, RF beats 
          Reply  Tue Apr 30 18:07:49 2019, anchal, DailyProgress, FSS, Spectrum of RFout from South Cavity Reflection RFPD SCavReflRFoutSpecAnalysis.pdf
             Reply  Wed May 8 20:03:43 2019, anchal, DailyProgress, FSS, FSS PDH Error Signal on South Path is in good health SCavPDHError20190508.pdfCavity_Refl_RFPD_TI_After_Modifications.pdf
Entry  Thu May 9 12:16:55 2019, anchal, Summary, FSS, Saving PDH error signal values 
Entry  Fri May 10 15:50:09 2019, anchal, Summary, Computers, modbus shifted to a git repo for version control 
Entry  Mon May 13 16:25:14 2019, anchal, Summary, Computers, Converted all PSL_Lab links to CTN links CorrectLinks.zip
    Reply  Mon May 13 16:54:15 2019, awade, Summary, Computers, Converted all PSL_Lab links to CTN links 
Entry  Mon May 13 19:12:56 2019, anchal, DailyProgress, Other, Set experiment for 2.6 mW transmission from cavities. 
Entry  Tue May 14 18:13:21 2019, anchal, DailyProgress, Computers, Added threshold channels in autolocker and fastmon rms monitor screenshots.zip
Entry  Thu May 16 13:46:46 2019, anchal, DailyProgress, TempCtrl, Alignment disturbing due to lab temp changes 
Entry  Wed May 15 19:00:26 2019, anchal, DailyProgress, South Cavity, Changes on South Path towards increasing power on FSS RFPD  
    Reply  Thu May 16 16:34:30 2019, anchal, DailyProgress, North Cavity, Changes on North Path towards increasing power on FSS RFPD  
Entry  Thu May 23 15:45:48 2019, anchal, DailyProgress, FSS, Oscillations in North FSS Mixer Channel and power NorthCavFSSOsc.pdf
    Reply  Thu May 23 15:56:22 2019, awade, DailyProgress, FSS, Oscillations in North FSS Mixer Channel and power 
Entry  Wed May 29 18:50:18 2019, anchal, DailyProgress, FSS, North FSS F and Crossover Frequency Measurement North_FSS_TF_Measurement_2019-05-29.pdf
Entry  Mon Jun 3 17:44:30 2019, anchal, DailyProgress, NoiseBudget, New Beat Note measurement 20190603_174101noiseBudget.pdf
Entry  Tue Jun 4 20:44:21 2019, rana, Summary, Other, next steps 
Entry  Thu Jun 6 18:14:17 2019, anchal, DailyProgress, BEAT, Moku Lab Frequency Noise Analysis MokuFrequencyNoiseAnalysis.zipMokuFrequencyNoiseAnalysis.pdf
Entry  Fri Jun 7 17:42:06 2019, anchal, DailyProgress, BEAT, Three Corner Hat Method 6x
Entry  Mon Jun 17 18:05:20 2019, anchal, DailyProgress, BEAT, Moku Frequency Noise Measurement IMG_20190617_180108.jpgMokuSelfFreqNoiseAnalysis.pdf
Entry  Mon Jun 24 14:00:40 2019, ScottA, DailyProgress, EOM, Bias Tee Addition EOM_driver_schematic.pdfEOM_driver_schematic_with_bias_tee.pdf
Entry  Thu Jun 27 17:06:57 2019, ScottA, DailyProgress, RFAM, Bias Tee S Matrix Bias_Tee_S_Matrix_6_27_2019.pdfBias-Tee.jpgBias_Tee_S-matrix_Data_6-27-2019.zip
Entry  Tue Jul 2 17:22:16 2019, ScottA, DailyProgress, RFAM, Bias Tee Data Analysis Bias_Tee_Fitting_Analysis_to_Single_C_and_L.zipFitting_Analysis.pdf
Entry  Wed Jul 3 11:33:47 2019, ScottA, DailyProgress, RFAM, Tuning Inductor value for EOM Driver Graphing_TF_BiasTee_and_Inductor_36_37MHz.zipTransfer_W_Bias_and_Inductor36and37.pdf
Entry  Thu Jul 4 16:46:01 2019, ScottA, DailyProgress, RFAM, Reflow Soldering 20190704_145145.jpg20190704_150723.jpg20190704_150904.jpg20190704_152206.jpg20190704_161249.jpg
Entry  Wed Jul 10 12:46:07 2019, ScottA, DailyProgress, RFAM, Addition of 1k ohm Resistor to input of DC port on Bias Tee Addition_of_1kohm.pdfzip-LTspice-and-jupyternotebook-1k_resistor.zip
Entry  Wed Jul 10 12:37:38 2019, ScottA, DailyProgress, TempCtrl, AD590 Board Reflow_Temp_board.jpeg
    Reply  Wed Jul 10 18:01:24 2019, rana, DailyProgress, TempCtrl, AD590 Board 
Entry  Sat Jul 13 22:19:35 2019, ScottA, DailyProgress, TempCtrl, AD590 Experimental Sketch and Zero Noise Budget AD590_Temperature_Sensing_Sketch.pdfZero_AD590_Noise_Budget.zipAD590_Noise_Budget.pdf
Entry  Tue Jul 16 11:19:32 2019, ScottA and AnnaR, HowTo, Other, How to Twist Wire 20190716_105513.jpg20190716_105613.jpg20190716_105744.jpg
Entry  Mon Jul 22 16:17:08 2019, ScottA, DailyProgress, TempCtrl, TIA Op-amp for AD590 Temp Circuit AD590_Diff_OpAmps_Noise_Budget.pdfZero_AD590_Noise_Budget_Different_Op_Amps.zipAD590_Diff_OpAmps_Noise_Budget_v2.pdf
Entry  Mon Jul 22 19:31:20 2019, anchal, DailyProgress, FSS, FF Gain channels converted to physical units 
Entry  Mon Jul 22 19:11:54 2019, anchal, Notes, Computers, WS1 upgraded to Debian 9, still showing some glitches 
    Reply  Mon Jul 22 20:55:41 2019, rana, Notes, Computers, WS1 upgraded to Debian 9, still showing some glitches 
Entry  Mon Jul 22 22:01:28 2019, ScottA, DailyProgress, TempCtrl, Differential Temperature Sensing Experimental Setup Diff_Temp_Setup_Pics.zip
Entry  Tue Jul 23 10:16:35 2019, ScottA, DailyProgress, TempCtrl, Differential Temp. Experiment Data Analysis AD590_Differential_Noise.pdfAD590_Differential_Noise.zip
    Reply  Tue Jul 23 11:24:08 2019, anchal, DailyProgress, TempCtrl, Differential Temp. Experiment Data Analysis AD590_Differential_Noise_Integrated.pdfAD590_Differential_Noise_Integrated.zip
Entry  Tue Jul 23 18:59:40 2019, ScottA, DailyProgress, RFAM, Transfer Function of EOM driver with Bias Tee and Dummy EOM Graphing_TF_BiasTee_7_23_2019.zipTransfer_EOM_driver_W_Bias_and_Dummy_EOM_37.pdf
Entry  Wed Jul 24 16:14:42 2019, ScottA, DailyProgress, RFAM, Transfer Function of EOM Driver plus Bias Tee from RF Input to EOM Graphing_TF_BiasTee_7_24_2019_atEOM.zipTransfer_at_EOM.pdf
Entry  Thu Jul 25 20:43:12 2019, ScottA and anchal, DailyProgress, RFAM, Setting up pick-off for RFAM measurement 
Entry  Mon Jul 29 13:55:15 2019, anchal, DailyProgress, FSS, Noise analysis of TTFSS FSSNoiseAndTFAnalysis.pdfFSSNoiseAndTFAnalysis.zip
Entry  Mon Jul 29 18:01:12 2019, ScottA and anchal, DailyProgress, RFAM, RFAM Set-up and Measurement  RAM_Measurement_data.zipRAM_37MHz_7_29_2019.pdf
Entry  Tue Jul 30 15:56:15 2019, ScottA, DailyProgress, RFAM, Time series for AC Port of RAM Measurement RAM_Measurement_Graphing_timeseries.zipRAM_Timeseries.pdf
    Reply  Wed Jul 31 17:53:20 2019, rana, DailyProgress, RFAM, Time series for AC Port of RAM Measurement 
Entry  Fri Aug 2 10:23:48 2019, ScottA, DailyProgress, RFAM, Difference in Transfer function of Bias-tee plus EOM with Different input power Transfer_EOM_driver_W_Bias_and_REAL_EOM_37.pdfREAL_EOM_TF_Spectrums_and_data.zipBias-Tee-and-Driver.jpg
ELOG V3.1.3-