40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 1 of 29  Not logged in ELOG logo
Entry  Thu Nov 5 07:07:40 2009, rana, Misc, RC noise, Frank's pictures in other log 
Entry  Sun Nov 8 14:38:56 2009, Frank, Laser, DAQ, channels for the temperature scan 
Entry  Sun Nov 8 14:35:25 2009, Frank, Laser, RefCav, resonance frequencies 
    Reply  Mon Nov 9 02:19:45 2009, rana, Laser, RefCav, resonance frequencies 
       Reply  Mon Nov 9 18:49:15 2009, Frank, Laser, RefCav, resonance frequencies 
Entry  Thu Nov 12 17:39:49 2009, Frank, Electronics, VCO, tuning range tuning.pdftuning.png
Entry  Thu Nov 12 17:45:02 2009, Frank, Laser, RefCav, laser crzstal temp settings for both cavities 
Entry  Fri Nov 13 11:12:38 2009, Frank, Laser, RefCav, temp settings for both cavities 
Entry  Thu Nov 12 18:01:10 2009, Frank, Things to Buy, RefCav, heaters for the other two chambers 
    Reply  Thu Nov 12 20:56:38 2009, rana, Things to Buy, RefCav, heaters for the other two chambers 
       Reply  Fri Nov 13 10:56:32 2009, Frank, Things to Buy, RefCav, heaters for the other two chambers 
          Reply  Fri Nov 13 12:46:35 2009, rana, Misc, RefCav, heaters for the other two chambers 
             Reply  Tue Nov 17 12:01:54 2009, Frank, Misc, RefCav, heaters for the other two chambers 
Entry  Wed Nov 18 20:45:52 2009, Frank, Misc, RefCav, leaking vaccum valve 
Entry  Wed Nov 18 20:52:39 2009, Frank, Laser, Laser, laser error 
Entry  Thu Nov 19 16:06:30 2009, Alberto, Computing, Computers, Elog debugging output - Down time programmed today to make changes 
    Reply  Thu Nov 19 18:50:33 2009, Alberto, Computing, Computers, Elog debugging output - Down time programmed today to make changes 
Entry  Sat Nov 21 17:27:32 2009, Frank, Misc, RefCav, old Minco heaters 
Entry  Mon Nov 23 17:05:51 2009, Frank, Laser, RefCav, heater and insulation added 100_0376.jpg100_0379.jpg100_0383.jpg100_0391.jpg
Entry  Tue Nov 24 11:07:30 2009, Frank, Laser, RefCav, slow actuator settings 
Entry  Mon Nov 30 15:01:40 2009, Frank, Electronics, VCO, VCO tuning 
    Reply  Sun Dec 6 13:20:52 2009, Frank, Electronics, VCO, VCO tuning vco-tuning.jpgvco-tuning.ps
Entry  Sun Dec 6 14:54:43 2009, Frank, Laser, RefCav, temp sensor added on refcav2 
Entry  Fri Dec 11 19:45:15 2009, Frank, Laser, RefCav, LHO RefCav available 
Entry  Thu Dec 17 13:55:07 2009, Frank, Computing, DAQ, Baja4700 jumper settings and setup 100_0428.JPG100_0431.JPG100_0432.JPG
Entry  Thu Dec 17 16:57:10 2009, Frank, Computing, DAQ, new analyzer cavity DAQ system 
Entry  Thu Dec 17 18:13:01 2009, Frank, Electronics, RefCav, power supply remote programming 100_0437.JPG000_0005.jpg
Entry  Fri Dec 18 13:13:12 2009, Frank, Computing, DAQ, channels for new VME-based DAQ system now available in fb1 
Entry  Tue Dec 22 00:47:40 2009, Frank, Laser, RefCav, cavity temp stabilization 
Entry  Tue Dec 22 16:15:03 2009, Frank, Laser, RefCav, FSS settings 
Entry  Mon Dec 28 17:01:43 2009, Frank, Laser, RefCav, thermal insulation end caps added 100_0456.JPG
Entry  Tue Dec 29 19:21:11 2009, Frank, Laser, RefCav, temperature stability refcav_temp1.jpg
Entry  Fri Jan 15 11:35:17 2010, Frank, Laser, RefCav, refcav update 100_0542.JPG
Entry  Fri Jan 15 12:28:54 2010, Frank, Laser, RefCav, foam cutting machine 12x
Entry  Fri Jan 15 12:53:31 2010, Frank, Laser, RefCav, latest slow actuator values 
Entry  Fri Jan 15 20:19:54 2010, Frank, Laser, RefCav, both cavities locked 
Entry  Thu Jan 28 16:07:29 2010, Frank, Computing, DAQ, psl channels moved to C3 + new channels 
Entry  Mon Feb 1 12:51:43 2010, Rana, Frank, DailyProgress, NoiseBudget, First Refcav noise measurement refcav-noise.pdf
Entry  Tue Feb 2 16:36:46 2010, Frank, Electronics, DAQ, DAQ pinouts 
Entry  Tue Feb 2 18:22:38 2010, Frank, Electronics, DAQ, QPD channels 
Entry  Wed Feb 3 13:05:26 2010, Frank, Laser, RefCav, beam pointing @ refvac pointing.jpg
Entry  Sun Jan 24 18:35:47 2010, Frank, Laser, RefCav, new slow actuator values 
    Reply  Tue Jan 26 03:38:10 2010, rana, Laser, RefCav, frequency findings  
       Reply  Wed Jan 27 11:25:33 2010, Frank, Laser, RefCav, frequency findings  
          Reply  Wed Feb 3 16:19:52 2010, Tara Chalermsongsak, Laser, RefCav, frequency findings  power_at_AOM.jpgReflected_pwr_from_AOM.jpg
             Reply  Wed Feb 3 18:58:50 2010, Tara, Laser, RefCav, frequency findings  comparison.JPGTbeam.JPGRbeam.JPG
Entry  Wed Feb 3 23:41:11 2010, Frank, Laser, RefCav, TF of ACAV (VCO+cavity+pd+mixer) TF_acav_pdh_all.pdf
Entry  Thu Feb 4 20:13:53 2010, Frank, Laser, Laser, output coupler to acav changed 
Entry  Thu Feb 4 22:01:27 2010, Frank, Laser, RefCav, acav re-aligned 
Entry  Fri Feb 5 05:13:09 2010, Peter, Frank, Laser, RefCav, everything back online 
Entry  Fri Feb 5 20:37:06 2010, Tara Chalermsongsak, Laser, RefCav, better pointing alignment 
Entry  Fri Feb 5 20:53:58 2010, Frank, Laser, RefCav, latest values for refcav 
Entry  Fri Feb 5 21:10:48 2010, Frank, Laser, RefCav, new PD for frequency-shifted power detection 
Entry  Fri Feb 5 21:53:13 2010, Frank, Laser, RefCav, strange things going on AOM-cable-length.JPG
    Reply  Sat Feb 6 12:19:14 2010, rana, Laser, RefCav, strange things going on 
Entry  Sun Feb 7 18:29:06 2010, Frank, Laser, Laser, new channels + changes 
Entry  Sun Feb 7 20:56:03 2010, Frank, Laser, RefCav, AOM power modulation & pointing 
Entry  Mon Feb 8 18:08:53 2010, Frank, Misc, AOM, thermal images of AOM 9x
Entry  Mon Feb 8 18:12:46 2010, Frank, Notes, AOM, impedance measurements AOM-impedance_2010-02-08.png
Entry  Mon Feb 8 18:27:42 2010, Tara Chalermsongsak, Laser, RefCav, Chaging Isomet AOM to Crystal Tech AOM 
Entry  Mon Feb 8 22:03:32 2010, Frank, Laser, RC noise, new results refcav-noise_2010-02-08.png
Entry  Tue Feb 9 18:33:59 2010, Frank, Laser, RC noise, even newer results refcav-noise_2010-02-09.png
    Reply  Wed Feb 10 04:01:50 2010, rana, Laser, RC noise, even newer results 
Entry  Wed Feb 10 18:04:01 2010, Tara Chalermsongsak, Laser, RefCav, QPD calibration 