Entry  Fri Aug 20 21:03:16 2010, Frank, Summary, DAQ, channel list for fb1 updated and framebuilder restarted 
Entry  Mon Aug 23 21:50:47 2010, Frank, Notes, RefCav, changed ACAV setpoint temperature 
Entry  Thu Aug 26 19:58:06 2010, Frank, Notes, BEAT, changed ACAV setpoint temperature - both cavities locked 
Entry  Thu Aug 26 23:00:35 2010, Frank, Notes, BEAT, lock-loss of both cavities 
Entry  Thu Aug 26 23:18:12 2010, Frank, Notes, BEAT, both cavities relocked 
    Reply  Fri Aug 27 19:02:24 2010, Frank, Notes, Computers, DAQ 
    Reply  Mon Aug 30 22:16:51 2010, Frank, Notes, Computers, note for resetting psl crate  
    Reply  Tue Aug 31 13:26:32 2010, Frank, Notes, Environment, antack (ants attack) 
    Reply  Tue Aug 31 13:40:00 2010, Frank, Notes, Computers, dead channel, C3:PSL-ACAV_TEMPAVG 
    Reply  Tue Aug 31 14:52:41 2010, Frank, Notes, Computers, dead channel, C3:PSL-ACAV_TEMPAVG 
    Reply  Tue Aug 31 15:04:51 2010, Frank, Notes, Computers, dead channel, C3:PSL-ACAV_TEMPAVG 
Entry  Tue Aug 31 15:11:28 2010, Frank, Notes, DAQ, C3:PSL-ACAV_RCTRANSPD broken? 
Entry  Tue Aug 31 15:15:44 2010, Frank, Notes, DAQ, how to measure ACAV channels without RCAV locked 
    Reply  Tue Aug 31 15:52:43 2010, Frank, Notes, DAQ, C3:PSL-ACAV_RCTRANSPD broken? 
    Reply  Tue Aug 31 18:33:13 2010, Frank, Notes, RefCav, changed acav setpt back to 37.3 
    Reply  Tue Aug 31 21:37:11 2010, Frank, Notes, RefCav, changed acav setpt back to 37.3 
Entry  Tue Aug 31 21:59:19 2010, Frank, Summary, Computers, still network problems 
Entry  Wed Sep 8 19:10:53 2010, Frank, DailyProgress, Laser, PBS/QWP-combination very bad 
Entry  Wed Sep 8 19:29:01 2010, Frank, Notes, DAQ, funny EPICS channel problems 
Entry  Thu Sep 9 23:20:19 2010, Frank, Summary, Computers, MAC address overview for PSL lab 
Entry  Fri Sep 10 12:25:34 2010, Frank, Notes, Laser, construction work done - Laser back on 
Entry  Fri Sep 10 12:32:04 2010, Frank, Summary, Computers, PSL crate rebooted 
Entry  Fri Sep 10 14:37:37 2010, Frank, Summary, DAQ, PSL crate reboot fixed channel problems 
Entry  Sat Nov 27 01:42:19 2010, Frank, Photos, RefCav, foam insulation and temp sensor location 6x
    Reply  Sun Dec 5 18:36:10 2010, Frank, DailyProgress, BEAT, PD for PLL: additional information 
    Reply  Fri Dec 10 12:07:34 2010, Frank, Summary, RefCav, RCAV/ACAV poles 
Entry  Wed Dec 15 01:35:44 2010, Frank, Notes, RefCav, things to do 
Entry  Mon Jan 24 19:05:41 2011, Frank, Notes, Electronics Equipment, RFPD photodiodes 
Entry  Tue Jan 25 11:30:05 2011, Frank, Notes, Electronics Equipment, Perkin Elmer 2mm InGaAs photodiodes - dark current characterization PerkinElmer_2mm.png
Entry  Wed Jan 26 20:21:57 2011, Frank, Summary, Electronics Equipment, ACAV RFPD modified D980454-00_modified_ACAV.pdf
Entry  Mon Jan 31 19:42:36 2011, Frank, Notes, Computers, current IP-address 
Entry  Tue Feb 1 19:26:47 2011, Frank, Notes, BEAT, loss of RF cables 
Entry  Tue Feb 1 20:47:14 2011, Frank, Notes, DAQ, VCO feedback signal now recording 
Entry  Tue Feb 1 23:16:10 2011, Frank, HowTo, Electronics Equipment, TF (attenuation) of 500ft of RG58  P1700783.JPGTF_500ft_RG58CU.png
Entry  Thu Feb 3 14:25:18 2011, Frank, Summary, BEAT, Frequency counter time series frequcount_timeseries2.pngfreqcounter_timeseries.dat
Entry  Fri Feb 4 01:03:47 2011, Frank, DailyProgress, BEAT, cable delay setup cable-delay.png
    Reply  Fri Feb 4 13:59:48 2011, Frank, DailyProgress, BEAT, trend of the setup Untitled.png
Entry  Fri Feb 4 19:26:50 2011, Frank, DailyProgress, BEAT, changed to shorter cable 
Entry  Sun Feb 6 02:38:07 2011, Frank, DailyProgress, RefCav, both cavities locked again 
Entry  Mon Feb 7 15:38:38 2011, Frank, Notes, BEAT, cable phase noise measurement stopped 
Entry  Mon Feb 7 16:14:19 2011, Frank, Notes, BEAT, cable phase noise measurement calibration 
Entry  Mon Feb 7 18:13:31 2011, Frank, Summary, VCO, VCO tuning - fitted function vco-tuning_fit2.pngvco-tuning_fit1.png
Entry  Mon Feb 7 20:33:00 2011, Frank, Summary, VCO, calibrated VCO monitor signal now available 
Entry  Tue Feb 8 00:03:02 2011, Frank, Summary, VCO, calibrated VCO monitor signal now fully available 
Entry  Tue Feb 8 10:41:59 2011, Frank, Summary, BEAT, cavity drift within 24h cavity-drift.png
Entry  Tue Feb 8 13:50:01 2011, Frank, Notes, RefCav, plz no more temp servo tuning - want to take data 
Entry  Wed Feb 9 19:57:43 2011, Frank, Notes, BEAT, new cable length - calibration data 
Entry  Thu Feb 10 00:21:55 2011, Frank, Summary, BEAT, comparison VCO feedback signal and "cable technique" 6x
Entry  Thu Feb 10 16:45:32 2011, Frank, Summary, Electronics Equipment, ultra low-noise pre-amps 7x
Entry  Fri Feb 11 13:46:20 2011, Frank, Notes, BEAT, calibrated error signal vs frequency mixer_output.pngcalibrated_error_signal.png