40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL, Page 1 of 29  Not logged in ELOG logo
Entry  Fri Jan 28 15:18:27 2022, Anchal, Summary, Equipment loan, CTN raided by 40m tribes PXL_20220128_230302199.jpgPXL_20220128_230017489.jpgPXL_20220128_230000139.jpgPXL_20220128_230247003.jpg
Entry  Wed Aug 18 11:12:47 2021, aaron, Misc, Electronics Equipment, SR560 to cryo 
Entry  Wed Sep 30 11:13:28 2020, anchal, Notes, Equipment loan, Took home moku and wenzel crystal for characterization 
    Reply  Tue Nov 24 16:16:53 2020, anchal, Notes, Equipment loan, Transferred moku to Cryo lab 
    Reply  Wed Jan 27 15:11:13 2021, anchal, Notes, Equipment loan, HP E3630A returned 
    Reply  Tue Feb 23 11:05:28 2021, anchal, Notes, Equipment loan, Took home moku and wenzel crystal for characterization 
Entry  Thu Feb 11 18:01:39 2021, Anchal, DailyProgress, InstrumentCharacterization, SR560 Intermodulation Test IP2SR560_11-02-2021_175029.pdfIMD2TFSR560s_11-02-2021_180005.pdfSR785_SelfIP2_12-02-2021_145140.pdfSR785_SelfIMD2TF_12-02-2021_145733.pdfSR560.zip
Entry  Wed Jan 27 15:12:05 2021, Anchal, Notes, Environment, Small leak or drip in the lab on West End WaterOnTheFloor.jpgWaterDropForming.jpgPathToWaterDrop.jpgWaterDripZoomedOut.jpgPropbablyTheSource.jpg
Entry  Tue Dec 15 12:59:14 2020, anchal, Notes, Equipment loan, Moved Marconi and Rb Clock to Crackle lab 
Entry  Wed Dec 9 18:13:12 2020, Paco, Misc, Equipment loan, new focus 1811 
Entry  Mon Dec 7 19:02:26 2020, Paco, Notes, Equipment loan, UPDH box  
Entry  Wed Dec 2 13:43:43 2020, anchal, Summary, Equipment loan, Transferred two gold box RFPDs to 40m 
Entry  Tue Dec 1 12:04:10 2020, Radhika, Notes, Equipment loan, Brought home low-noise preamplifier 
Entry  Mon Nov 23 10:58:46 2020, anchal, Notes, Laser, North laser not switching on, power supply display not working PXL_20201123_184931888.mp4
    Reply  Mon Nov 23 14:56:59 2020, Koji, Notes, Laser, North laser not switching on, power supply display not working 
       Reply  Mon Nov 30 10:28:08 2020, Anchal, Notes, Laser, North laser not switching on, power supply display not working image-ebd6ed74-fed3-4890-b45d-07d36e3b3000.jpg
          Reply  Mon Nov 30 21:31:56 2020, Koji, Notes, Laser, North laser not switching on, power supply display not working 
Entry  Thu Nov 26 11:26:14 2020, agupta, Summary, TempCtrl, Cavity temperature estimate CavityTemperatureEstimate.pdf
Entry  Tue Nov 24 16:23:26 2020, Paco, Misc, Equipment loan, broadband EOM 
Entry  Mon Nov 9 16:53:55 2020, Radhika, Notes, Computers, Brought home Dell laptop 
Entry  Sat Oct 10 08:43:30 2020, anchal, Summary, Electronics Equipment, Red Pitaya and Moku characterization RedPitayaAndWenzelCrystalNoiseComp.pdfASD_Data_And_Plots.zipMokuLab_Phasemeter_Block_Diagram.pdf
Entry  Wed Sep 23 00:21:02 2020, aaron, Misc, Equipment loan, HP 8560E SA to Cryo 
Entry  Tue Sep 15 15:13:44 2020, Anchal, Notes, Environment, HEPA filters switched on. Measurement stopped. 
Entry  Wed May 13 18:07:32 2020, anchal, DailyProgress, NoiseBudget, Bayesian Analysis CTN_Bayesian_Inference_Analysis_Of_Best_Result.pdf
    Reply  Fri May 15 12:09:17 2020, aaron, DailyProgress, NoiseBudget, Bayesian Analysis 
       Reply  Fri May 15 16:50:24 2020, anchal, DailyProgress, NoiseBudget, Bayesian Analysis 
          Reply  Fri May 22 17:22:37 2020, anchal, DailyProgress, NoiseBudget, Bayesian Analysis CTN_Bayesian_Inference_Analysis_Of_Best_Result.pdf
             Reply  Mon May 25 08:54:26 2020, anchal, DailyProgress, NoiseBudget, Bayesian Analysis with Hard Ceiling Condition CTN_Bayesian_Inference_Analysis_Of_Best_Result_Hard_Ceiling.pdf
                Reply  Tue May 26 15:45:18 2020, anchal, DailyProgress, NoiseBudget, Bayesian Analysis CTN_Bayesian_Inference_Analysis_Of_Best_Result.pdfCTN_Bayesian_Inference_Analysis_Of_Best_Result_Hard_Ceiling.pdf
                   Reply  Thu May 28 14:13:53 2020, anchal, DailyProgress, NoiseBudget, Bayesian Analysis CTN_Bayesian_Inference_Analysis_Of_Best_Result_New.pdf
                      Reply  Sun May 31 11:44:20 2020, Anchal, DailyProgress, NoiseBudget, Bayesian Analysis Finalized CTN_Bayesian_Inference_Final_Analysis.pdf
                         Reply  Mon Jun 1 11:09:09 2020, rana, DailyProgress, NoiseBudget, Bayesian Analysis Finalized 
                         Reply  Thu Jun 4 09:18:04 2020, Anchal, DailyProgress, NoiseBudget, Bayesian Analysis Finalized CTN_Bayesian_Inference_Final_Analysis.pdf
                            Reply  Thu Jun 11 14:02:26 2020, Anchal, DailyProgress, NoiseBudget, Bayesian Analysis Finalized CTN_Bayesian_Inference_Final_Analysis.pdf
                               Reply  Mon Jun 15 16:43:58 2020, Anchal, DailyProgress, NoiseBudget, Better measurement on June 14th CTN_Bayesian_Inference_Final_Analysis.pdf
                                  Reply  Tue Jun 23 17:28:36 2020, Anchal, DailyProgress, NoiseBudget, Better measurement on June 22nd (as I turned 26!) CTN_Best_Measurement_Result.pdf
                                     Reply  Wed Jun 24 21:14:58 2020, Anchal, DailyProgress, NoiseBudget, Better measurement on June 24th 
                               Reply  Fri Jun 26 12:38:34 2020, Anchal, DailyProgress, NoiseBudget, Bayesian Analysis Finalized, Adding Slope of Bulk Loss Angle as variable CTN_Bayesian_Inference_Final_Analysis_with_Slope.pdf
Entry  Mon Jun 15 17:58:02 2020, anchal, DailyProgress, Documentation, CTN paper 
Entry  Thu Jan 10 10:39:27 2019, anchal, DailyProgress, NoiseBudget, New noise budget code is ready, but 
    Reply  Mon Aug 12 11:56:21 2019, anchal, DailyProgress, NoiseBudget, Adding specifics of discepancy 
       Reply  Tue Aug 13 11:59:56 2019, anchal, DailyProgress, NoiseBudget, Checking the differences between old and new noisebudget ComparisonOfOldandNewNoisebudget.pdfComparisonOfOldandNewNoisebudget.zip
          Reply  Tue Aug 13 17:05:53 2019, aaron, DailyProgress, NoiseBudget, Checking the differences between old and new noisebudget 
       Reply  Tue Sep 24 15:40:33 2019, anchal, DailyProgress, NoiseBudget, Adding specifics of discepancy 2 ComparisonEffReflectivities.pdf
          Reply  Tue Sep 24 17:11:13 2019, anchal, DailyProgress, NoiseBudget, Adding specifics of discepancy 2 (More) ComparisonEffReflectivitiesSignChange.pdf
             Reply  Tue Sep 24 19:39:06 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles VariationOfCoatingBrownianNoiseEstimate.pdfVariationOfCoatingBrownianNoiseEstimate.zip
                Reply  Fri Sep 27 16:40:49 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles Better Plots VariationOfCoatingBrownianNoiseEstimate.pdfVariationOfCoatingBrownianNoiseEstimate.zip
                   Reply  Mon Sep 30 11:14:41 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles 2D Plots VariationOfCoatingBrownianNoiseEstimate2.pdfVariationOfCoatingBrownianNoiseEstimate2.zip
                      Reply  Mon Sep 30 12:25:24 2019, rana, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles 2D Plots 
                         Reply  Mon Sep 30 20:08:42 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Beam Radius VariationOfCoatBrEstBeamRadius.pdfVariationOfCoatBrEstBeamRadius.zip
                            Reply  Tue Oct 1 13:46:49 2019, anchal, DailyProgress, NoiseBudget, Using bayesian inference to estimate loss Angles BayesianAnalysis.pdfBayesianAnalysis.zip
                            Reply  Wed Oct 2 15:13:27 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Beam Radius VariationOfCoatBrEstBeamRadius.pdfVariationOfCoatBrEstBeamRadiusv2.zip
                               Reply  Wed Oct 23 13:21:12 2019, anchal, DailyProgress, NoiseBudget, Fixed all discrepancies. aLIGOComplexReflectivityVariationFig5.pdfaLIGOBreakDownThermalNoiseFig7.pdfaLIGOCoatingBrNoiseCalculations.zip
       Reply  Fri Jun 12 12:34:08 2020, anchal, DailyProgress, NoiseBudget, Resolving discrepancy #1 concretly 
Entry  Mon Jun 8 18:19:46 2020, anchal, Misc, Other, DAMOP Conference Brief Summary 
Entry  Mon May 11 17:34:33 2020, anchal, Notes, Documentation, DAMOP Poster from CTN Lab 
Entry  Mon May 4 17:18:24 2020, anchal, Notes, Seismic, estimation of Seismic Noise coupling due to mirror birefringence CavityTorsionalSeismicCoupling.pdfCavityTorsionalSeismicCoupling.zip
Entry  Thu Mar 19 15:34:41 2020, anchal, DailyProgress, North Cavity, North path's buggy nature solved IMG_20200319_154013.jpg
    Reply  Sun Mar 22 17:23:29 2020, anchal, DailyProgress, North Cavity, North path's buggy nature NOT solved 
       Reply  Wed Mar 25 15:50:57 2020, anchal, DailyProgress, North Cavity, North path's buggy nature NOT solved Screen_Shot_2020-03-25_at_3.48.24_PM.png
          Reply  Tue Apr 14 12:24:16 2020, anchal, DailyProgress, North Cavity, North path's buggy nature Strikes Again! NorthPathWentBuggy.pdf
             Reply  Thu Apr 16 18:08:56 2020, anchal, DailyProgress, North Cavity, North path stopped being buggy NorthPathStoppedBeingBuggy.pdf
Entry  Thu Feb 13 16:35:32 2020, anchal, DailyProgress, BEAT, BN Detector was saturated. Reduced laser powers. 
    Reply  Fri Feb 14 10:59:13 2020, anchal, DailyProgress, BEAT, Beatnote noise lowered in low frequency region 
       Reply  Mon Feb 17 16:08:23 2020, anchal, DailyProgress, BEAT, Beatnote noise lowered in low frequency region with ISS CTN_Noise_Budget_Effect_ISS_ON.pdf
          Reply  Fri Feb 21 16:22:04 2020, anchal, DailyProgress, BEAT, Beatnote noise lowered in low frequency region with ISS CTN_Noise_Budget_Effect_ISS_ON_New.pdf
             Reply  Tue Mar 3 10:02:12 2020, anchal, DailyProgress, BEAT, Lowest ever beatnote spectrum today! CTN_Noise_Budget_March03-2020.pdf
                Reply  Thu Mar 12 11:06:35 2020, anchal, DailyProgress, BEAT, Lowest ever beatnote spectrum today! CTN_Noise_Budget_March11-2020.pdf
                   Reply  Wed Mar 18 12:51:22 2020, anchal, DailyProgress, BEAT, Super beatnote measurement analysis results CTN_Beatnote_SuperMeasurement_March13-16.pdf
                      Reply  Mon Apr 13 16:52:30 2020, anchal, DailyProgress, BEAT, Beatnote measurements back on track CTN_Latest_BN_Spec.pdf
Entry  Mon Mar 16 16:16:17 2020, anchal, DailyProgress, ISS, Added true OOL transmission PD for South Path 
    Reply  Tue Mar 17 18:03:22 2020, anchal, DailyProgress, ISS, Added true OOL transmission PD for North Path IMG_20200317_180420.jpg
Entry  Thu Mar 12 19:11:00 2020, shruti, DailyProgress, ISS, Removed half-wave plate in north path 
Entry  Fri Oct 4 13:41:44 2019, anchal, Notes, FSS, FSS Plant Model FSS_Plant_Zero_Sim.pdfPlantModel.pdfPlantModel.zip
    Reply  Fri Oct 4 14:56:42 2019, Ian MacMillan, Notes, FSS, FSS Plant Model PlantModelCircuit.pdf
       Reply  Tue Oct 8 10:41:43 2019, anchal, Notes, FSS, FSS Plant Model 
          Reply  Mon Oct 14 12:54:41 2019, anchal, Notes, FSS, FSS Plant Model v2 FSS_Plant_Zero_Sim.pdfPlantModelv2.pdfPlantModelv2.zip
             Reply  Tue Oct 22 13:07:45 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PlantDig.pdfEOM_Transfer_Function.pdfPZT_Transfer_Function.pdf
                Reply  Thu Oct 24 11:42:06 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
                   Reply  Tue Dec 3 17:27:54 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 IMG_8065.jpegIMG_8069.jpeg
                      Reply  Mon Dec 9 18:08:13 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 OutputGraphsTransferFunction.pdf_Circuit_Design_V1.zip
                         Reply  Tue Dec 10 11:57:58 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 IMG_8124.jpeg
                            Reply  Thu Dec 12 11:54:11 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PZT_LowFq_V1.pdfPZT_HighFq_V1.pdfEOM_LowFq_V1.pdfEOM_HighFq_V1.pdf
                               Reply  Thu Dec 12 19:05:33 2019, rana, Notes, FSS, FSS Plant Model v2 
                                  Reply  Mon Dec 16 09:43:56 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PZT_TF.pdfEOM_TF.pdfNon-Moku_Data_PlantCir_V1.zip
                                     Reply  Tue Jan 14 13:30:39 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 EOM_TF_V1.pdfPZT_TF_V1.pdfPlant_CIR_TF.zip
                                        Reply  Tue Jan 14 13:32:16 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 FSSPlantModelV2SCH.pdfFSSPlantModelV2.pdfPlant_Circuit_Board_Eagle.zip
                                           Reply  Tue Jan 28 13:27:25 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 LIGO-D2000020-v1.pdfBOARD_LIGO-D2000020-v1.pdfEagle_LIGO-D2000020-v1.zip
                                              Reply  Mon Feb 10 12:46:17 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
                                              Reply  Fri Feb 14 16:46:47 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 TFAG4395A_14-02-2020_155048.pdfTFAG4395A_14-02-2020_165608.pdf
                                                 Reply  Tue Feb 18 15:42:46 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PZT_TF_V1.pdfEOM_TF_V1.pdfTransfer_Functions_FSS.zip
                                                    Reply  Tue Mar 3 17:13:04 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 image.pngPLT_Spectrum.pdf20200303_IanSimPlant.zipPLT_Spectrum.pdfPLT_TF.pdf
                                                       Reply  Wed Mar 11 15:40:50 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 TFSR785_06-03-2020_135844_PZT.pdfTF_V1.zip
                                                          Reply  Thu Mar 12 16:21:49 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 TFSR785_10-03-2020_175129.pdfTFSR785_10-03-2020_175129.txt
                                                          Reply  Thu Mar 12 17:18:51 2020, rana, Notes, FSS, FSS Plant Model v2 
Entry  Tue Mar 3 11:49:16 2020, anchal, DailyProgress, ISS, Transmitted Laser Relative Intensity Noise CTN_Trans_RIN_measurement.pdf
    Reply  Sat Mar 7 09:50:31 2020, anchal, DailyProgress, ISS, Transmitted Laser Relative Intensity Noise - Out of loop CTN_Trans_RIN_measurement.pdf
       Reply  Wed Mar 11 12:45:15 2020, rana, DailyProgress, ISS, Transmitted Laser Relative Intensity Noise - Out of loop 
          Reply  Wed Mar 11 13:16:09 2020, anchal, DailyProgress, ISS, Transmitted Laser Relative Intensity Noise - Out of loop 
             Reply  Wed Mar 11 16:43:55 2020, anchal, DailyProgress, ISS, Comparison between Out of loop vs In loop RIN CTN_Trans_RIN_OOLvsIL.pdf
Entry  Fri Feb 14 17:40:27 2020, anchal, DailyProgress, ISS, Installed ISS on both paths using SR560s IMG_20200214_174127.jpgISS_Effect.pdf
    Reply  Sat Feb 15 18:57:43 2020, rana, DailyProgress, ISS, Installed ISS on both paths using SR560s 
       Reply  Thu Feb 20 17:42:23 2020, rana, DailyProgress, ISS, Installed New ISS on both paths using SR560s ISS_New_Analysis.pdf
          Reply  Sun Feb 23 18:19:32 2020, rana, DailyProgress, ISS, Installed New ISS on both paths using SR560s 
             Reply  Fri Feb 28 14:00:11 2020, anchal, DailyProgress, ISS, Installed New ISS on both paths using SR560s - PROBLEM 
                Reply  Sun Mar 1 16:34:31 2020, rana, DailyProgress, ISS, Installed New ISS on both paths using SR560s - PROBLEM 
                   Reply  Mon Mar 2 16:48:12 2020, anchal, DailyProgress, ISS, Follow-up, porbalem stopped happening, OLTF plot. NISS_OLTF.pdf
Entry  Thu Feb 13 18:06:00 2020, anchal, DailyProgress, NoiseBudget, Adding dark noise measurement of beatnote detector SN101 IMG_20200213_180742.jpgBNDetDarkNoise.pdf
Entry  Mon Feb 10 17:41:25 2020, anchal, DailyProgress, scatter, Cleaned up table; Installed hex beam dumps 
    Reply  Thu Feb 13 18:00:30 2020, anchal, DailyProgress, scatter, blocked NF1811 with hex beam dump 
Entry  Wed Jan 29 14:49:48 2020, anchal, DailyProgress, BEAT, Beanote Spectrum vs FSS Gain Values Beatnote_vs_FSSGain.pdf
    Reply  Wed Jan 29 15:58:26 2020, anchal, DailyProgress, BEAT, Beanote Spectrum vs FSS Gain Values Beatnote_vs_FSSGain.pdf
       Reply  Fri Feb 7 09:57:32 2020, anchal, DailyProgress, BEAT, Spanned gain parameter space in NFSS and checked beatnote NFSS_Spanned_Beatnote_Variation.pdf
          Reply  Fri Feb 7 18:12:03 2020, anchal, DailyProgress, BEAT, Spanned gain parameter space in SFSS and checked beatnote SFSS_Spanned_Beatnote_Variation.pdf
             Reply  Mon Feb 10 11:07:33 2020, anchal, DailyProgress, BEAT, Spanned gain parameter space in PMCs and checked beatnote PMC_Spanned_Beatnote_Variation.pdf
                Reply  Thu Feb 13 15:27:18 2020, anchal, DailyProgress, BEAT, Further iterated back and forth to optimized FSS Gains. FSS_Gain_Span.pdf
Entry  Fri Aug 30 18:40:01 2019, anchal, Notes, BEAT, Quick note: BN detector changed to NF1811 
    Reply  Wed Sep 4 14:41:33 2019, anchal, Notes, BEAT, Quick note: BN detector changed to SN101 and other changes 
       Reply  Thu Sep 5 19:52:06 2019, anchal, Notes, BEAT, Quick note: FSS gain reduced, Moku input range changed 
          Reply  Tue Sep 10 19:43:02 2019, anchal, Notes, BEAT, Quick note: Detector changed to NF1811 
             Reply  Mon Sep 16 18:03:33 2019, anchal, Notes, BEAT, Quick note: Detector changed to Sn101 
                Reply  Tue Oct 1 17:28:25 2019, anchal, Notes, BEAT, Quick note: Moku connected with USB 
                   Reply  Tue Oct 15 13:23:16 2019, anchal, Notes, Safety, Quick note: Shutting Down Lasers as Safety Sign is not working 
                      Reply  Tue Oct 15 18:53:00 2019, anchal, Notes, Safety, Quick note: Lasers started again 
                         Reply  Wed Oct 16 19:11:11 2019, anchal, Notes, BEAT, Quick note: Cavities locked; Changed BN Freq Counter Poll Rate 
                            Reply  Fri Oct 18 17:47:49 2019, anchal, Notes, BEAT, Quick note: BN Noise bakc to where it was. 
                               Reply  Mon Nov 4 20:13:44 2019, anchal, Notes, BEAT, Quick note: FSS Loop Gain Changes 
                                  Reply  Wed Jan 22 15:20:00 2020, anchal, Notes, BEAT, Notch improved on FSS RFPDs. Gain values increased as well. 
                                     Reply  Thu Jan 30 10:55:22 2020, anchal, Notes, BEAT, Lowest ever beatnote spectrum today. CTN_Daily_BN_Spec.pdf
                                        Reply  Wed Feb 12 10:01:04 2020, anchal, Notes, BEAT, Increased sampling rate to 125kSa/s; lowest noise in higher frequencies 
Entry  Tue Feb 11 18:21:17 2020, anchal, DailyProgress, PMC, Can't keep my mind of this; Why PMC Error signal has these oscillations? PMCErrSignalTimeSeries.pngPMC_Error_Signal_Analysis.pdf
Entry  Fri Nov 1 17:54:47 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Ouput under inspection NFSS_RFPD_Output_Oscilloscope.pdfSFSS_RFPD_Output_Oscilloscope.pdfNFSS_RFPD_RF_OUT_COUPLED.pdfSFSS_RFPD_RF_OUT_COUPLED.pdf
    Reply  Tue Nov 5 18:37:59 2019, anchal, DailyProgress, FSS, FSS Diagnostics - TTFSS Testpoint Spectrum Data FSS_TP_Spectrum.pdf
       Reply  Sat Nov 9 19:28:36 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Loop nonlinearity Test NFSS_NonLinearity_Test.pngSFSS_NonLinearity_Test.pngsignal-attachment-2019-11-09-195635.jpeg
          Reply  Mon Nov 11 20:42:49 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Two Tone Test NFSS_RFPD_SN009_TF_11-11-2019_183131.pdfSFSS_RFPD_SN010_TF_11-11-2019_203310.pdfFSStwoToneTest.pdf
             Reply  Tue Nov 12 18:36:59 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Two Tone Third Order Intermodulation Test FSStwoToneThirdOrderIM.pdf
                Reply  Thu Nov 14 12:19:32 2019, rana, DailyProgress, FSS, FSS Diagnostics - Two Tone Third Order Intermodulation Test 
                   Reply  Tue Nov 19 18:51:02 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Second-order Distortion Calculation FSSDistortionCalc.pdfFSSDistortion.zip
                      Reply  Mon Dec 9 19:54:44 2019, anchal, DailyProgress, FSS, FSS Diagnostics - How much distortion affects the functioning of PDH? 
       Reply  Wed Nov 27 13:59:24 2019, anchal, DailyProgress, FSS, FSS Diagnostics - TTFSS TP1 TimeSeries NFSS_TP1_Oscilloscope.pdf
          Reply  Wed Nov 27 15:17:51 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Quick HF OLTF of NFSS NFSS_OLTF_HF.pdf
             Reply  Wed Nov 27 16:31:20 2019, rana, DailyProgress, FSS, FSS Diagnostics - Quick HF OLTF of NFSS 
                Reply  Wed Dec 4 18:11:09 2019, anchal, DailyProgress, FSS, Free running laser frequency noise spectrum PMCErrorSignals.pdf
                   Reply  Thu Dec 5 18:25:11 2019, rana, DailyProgress, FSS, Free running laser frequency noise spectrum 
                   Reply  Tue Dec 17 18:29:58 2019, anchal, DailyProgress, FSS, Need for ISS? 
                      Reply  Wed Dec 18 18:40:32 2019, anchal, DailyProgress, FSS, Maybe the NPRO Laser isn't bad after all NorthLaserRINAnalysis.pdf
                         Reply  Wed Dec 18 22:03:17 2019, rana, DailyProgress, FSS, Maybe the NPRO Laser isn't bad after all 
                            Reply  Fri Dec 20 15:00:30 2019, anchal, DailyProgress, FSS, PZT, EOM to RIN TF Measurement NorthLaserPZTEOMtoRINTF.pdf
                               Reply  Fri Dec 20 18:08:44 2019, anchal, DailyProgress, FSS, PZT, EOM to RIN TF Measurement Through FSS NorthLaserPZTEOMtoRINTFThruFSS.pdf
                                  Reply  Tue Jan 7 17:59:20 2020, anchal, DailyProgress, FSS, NPMC TF NPMC_TF.pdf
       Reply  Thu Dec 12 19:15:55 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Beatnote Spectrum wrt Laser Power and Modulation Index BeatnoteSpectrumwrtPowerandModindex.pdf
       Reply  Tue Dec 17 16:55:07 2019, anchal, DailyProgress, FSS, FSS Diagnostics - TTFSS North U7 Boost Stage Input-Output TimeSeries NFSS_UT_TS_Analysis.pdf
    Reply  Tue Nov 12 11:39:48 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Ouput under inspection 
    Reply  Fri Dec 13 16:24:02 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD Circuit Latest Available Photos SN009.jpgSN010.jpgSN009.jpgSN010.jpg
    Reply  Fri Dec 13 17:44:05 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Coupled Output Offset 
       Reply  Mon Jan 13 19:04:38 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN009 (North RFPD) Notch Improvement Attempt SN009.jpgSN009_D980454-00-C.pdfSN009_Notch_Improvement_Attempt.pdf
          Reply  Tue Jan 14 18:19:33 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN009 (North RFPD) Notch Improved! SN009.jpgSN009_D980454-00-C.pdfSN009_Notch_Improvement_Attempt.pdf
             Reply  Thu Jan 16 11:17:15 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN010 (South RFPD) Notch Improvement Attempt SN010.jpgSN010_D980454-00-C.pdfSN010_Notch_Improvement_Attempt.pdf
                Reply  Thu Jan 16 20:18:44 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN010 (South RFPD) Notch Improved SN010.jpgSN010_D980454-00-C.pdfSN010_Notch_Improved.pdf
                   Reply  Mon Jan 27 18:29:19 2020, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Out Spectrum FSS_RFPD_RFOut_Spectrum.pdf
Entry  Thu Sep 4 19:39:36 2014, Tara, Evan, DailyProgress, FSS, TTFSS OLTFs pdhTFs.pdf
    Reply  Sun Sep 7 11:54:21 2014, Evan, DailyProgress, FSS, TTFSS OLTFs, residual frequency noise pdhTFs.pdfoltfNorth.pdfoltfSouth.pdffrnoise.pdfnoiseBudget.pdf
       Reply  Mon Sep 8 04:20:41 2014, rana, DailyProgress, FSS, TTFSS OLTFs, residual frequency noise 
       Reply  Wed Oct 2 19:09:31 2019, anchal, DailyProgress, FSS, TTFSS OLTFs; Repeated this 5 year old measurement FSS_OLTF.pdf
          Reply  Thu Jan 9 19:00:19 2020, anchal, DailyProgress, FSS, TTFSS OLTFs FSS_OLTF.pdf
             Reply  Wed Jan 22 14:16:28 2020, anchal, DailyProgress, FSS, TTFSS OLTFs FSS_OLTF.pdf
                Reply  Wed Jan 22 16:00:26 2020, anchal, DailyProgress, FSS, TTFSS OLTFs with Maximum Gain FSS_OLTF.pdf
                   Reply  Thu Jan 23 19:23:03 2020, anchal, DailyProgress, FSS, NFSS Boost Stage NorthFSSBosstStageTF.pdf
Entry  Mon Dec 30 10:33:33 2019, anchal, Summary, Other, Summary of questions asked in December 
Entry  Tue Dec 10 17:03:41 2019, anchal, DailyProgress, Laser, Laser Settings back to defaults 
    Reply  Wed Dec 18 14:04:43 2019, anchal, DailyProgress, Laser, South Laser Power Dropped. SouthLaserPowerDropped.pdf
Entry  Wed May 22 17:48:49 2019, anchal, DailyProgress, TempCtrl, Vacuum Can Temp Sensors restarted with new board Temp-Sensor-Box.jpegBreakoutBox.jpeg
    Reply  Wed Dec 4 17:09:44 2019, anchal, DailyProgress, TempCtrl, Increased range of out-of-loop temperature sensor 
Entry  Sat Nov 9 13:46:08 2019, shruti, Misc, Electronics Equipment, Borrowed 
Entry  Mon Nov 4 15:03:26 2019, anchal, DailyProgress, FSS, Raised North TTFSS; Fixed the boxes. signal-attachment-2019-11-04-161746.jpeg
Entry  Mon Oct 14 17:01:43 2019, anchal, Notes, Laser, South Laser Switched Off! SouthLaserStopped.pdf
    Reply  Mon Oct 14 18:30:14 2019, anchal, Notes, PMC, South PMC Error Signal Oscillations SPMCMixerOutOscillations.pdf
       Reply  Tue Oct 15 18:54:16 2019, anchal, Notes, PMC, South PMC further problems 
          Reply  Wed Oct 16 16:56:43 2019, anchal, Notes, PMC, South PMC won't work with it's own Servo Card only 
             Reply  Wed Oct 16 17:33:08 2019, Koji, Notes, PMC, South PMC won't work with it's own Servo Card only 
                Reply  Wed Oct 16 18:46:58 2019, anchal, Notes, PMC, South PMC started working somehow :( 
                   Reply  Wed Oct 23 17:39:44 2019, anchal, Notes, PMC, South PMC started working somehow :( 
                      Reply  Fri Oct 25 16:50:12 2019, anchal, Notes, PMC, South PMC problem debugging efforts 
                         Reply  Tue Oct 29 19:10:59 2019, anchal, Notes, PMC, South PMC problem debugging efforts SPMC_Diagnostics.pdf
                            Reply  Wed Oct 30 15:15:28 2019, anchal, Notes, PMC, Replacing U5A AD602 didn't solve the issue. 
                               Reply  Wed Oct 30 18:35:31 2019, anchal, Notes, PMC, Issue closed 
                                  Reply  Mon Nov 4 12:15:01 2019, anchal, Notes, PMC, Changing the autolocking method 
Entry  Thu Sep 5 16:59:36 2019, anchal, DailyProgress, BEAT, Beatnote Frequency long time series data BeatnoteLongTimeSeries.pdf
    Reply  Wed Oct 2 12:22:44 2019, anchal, DailyProgress, BEAT, Beatnote Frequency long time series data BeatnoteLongTimeSeries.pdf
       Reply  Tue Oct 8 16:48:07 2019, putInYourRealName, DailyProgress, BEAT, Beatnote Frequency long time series data 
          Reply  Wed Oct 9 16:08:39 2019, anchal, DailyProgress, BEAT, Beatnote Frequency long time series data BeatnoteLongTimeSeriesPart2.pdf
Entry  Tue Sep 3 16:48:23 2019, anchal, DailyProgress, NoiseBudget, Daily updates on noise budget 
    Reply  Wed Sep 11 10:42:50 2019, anchal, DailyProgress, NoiseBudget, 500 Hz hump gone! 
       Reply  Mon Sep 30 16:47:15 2019, anchal, DailyProgress, NoiseBudget, Adding links again; Comparison with Old Estimates on same plot 
Entry  Wed Sep 4 17:31:19 2019, anchal, Notes, Vacuum, Plan of Action for Vacuum Can Flange replacement 
    Reply  Fri Sep 20 18:34:19 2019, anchal, Notes, Vacuum, Possible reflected lights on upgrade CTNPrompReflectionAfterUpgrade.pdfCTNPrompReflectionAfterUpgrade.zip
Entry  Mon Sep 16 17:05:00 2019, anchal, Summary, BEAT, Beatnote Frequency stabalization BeatnotePIDPerformance.pdf
Entry  Fri Sep 13 16:59:39 2019, anchal, DailyProgress, PMC, South PMC Servo Card changes 
Entry  Fri Sep 13 16:46:54 2019, anchal, Summary, TempCtrl, Cavity heater resistances remeasured 
Entry  Fri Sep 13 16:40:56 2019, anchal, DailyProgress, BEAT, New channel added; BNSignUpdate made better 
ELOG V3.1.3-