Entry  Tue Apr 6 18:39:04 2010, Tara Chalermsongsak, Laser, RefCav, Calculation for higher order mode's frequency 1.png
    Reply  Wed Apr 7 12:30:47 2010, rana, Laser, RefCav, Calculation for higher order mode's frequency 
Message ID: 98     Entry time: Wed Apr 7 12:30:47 2010     In reply to: 97
Author: rana 
Type: Laser 
Category: RefCav 
Subject: Calculation for higher order mode's frequency 

I deleted your plot, since it contained no axes labels. We have a strict rule against plots like those. You must have physical units and labels in all plots. See the gyro HOM plots for an example.