40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
PSL |
Not logged in |
 |
|
Mon Apr 16 16:21:01 2012, tara, Notes, optic, windows for vacuum chamber
|
Tue Apr 17 19:51:54 2012, tara, Notes, optic, windows for vacuum chamber
|
Thu Apr 19 03:12:23 2012, tara, Notes, optic, windows for vacuum chamber
|
Sun Apr 22 23:09:38 2012, tara, Notes, optic, windows for vacuum chamber
|
Mon Apr 23 16:52:16 2012, tara, Notes, optic, windows for vacuum chamber
|
Wed Apr 25 10:44:29 2012, Frank, Notes, optic, windows for vacuum chamber
|
Thu Apr 26 08:35:57 2012, steve, Notes, optic, windows for vacuum chamber
|
Fri Apr 27 08:46:24 2012, Frank, Notes, optic, windows for vacuum chamber
|
Tue May 1 20:37:16 2012, tara, Notes, optic, windows for vacuum chamber
|
Fri May 11 17:52:17 2012, tara, Notes, optic, windows for vacuum chamber
|
Wed May 16 22:27:13 2012, tara, Notes, optic, windows for vacuum chamber 
|
Mon May 21 16:53:38 2012, tara, Notes, optic, windows for vacuum chamber  
|
Wed May 23 15:04:53 2012, steve, Notes, optic, windows for vacuum chamber
|
|
Message ID: 964
Entry time: Wed May 16 22:27:13 2012
In reply to: 960
Reply to this: 969
|
Author: |
tara |
Type: |
Notes |
Category: |
optic |
Subject: |
windows for vacuum chamber |
|
|
I finished the drawing for new vacuum windows. The o-ring for the windows will be #223 (1/8" thickness). I'll consult with Steve one more time before I submit the drawings.
A few comments about this desing:
- The design is intend for 2" OD, 0.25" thickness window. The blank has 2 degree wedge surface for the window.
- The grooves for the o rings are based on the instruction on previous entry.
- The material for the small window, and the 10" window will be stainless steel.
- I feel that the drawing is a bit unclear, I'll try to draw it properly.


Quote: |
Nice reference for O-ring + groove design. I'll put it on CTN wiki as well.
The o-ring I plan to use for 2" OD window is #223, 0.139" thickness, ID = 1.609", OD = 1.887". McMasterCarr.
|
|