40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
PSL |
Not logged in |
 |
|
Mon Apr 16 16:21:01 2012, tara, Notes, optic, windows for vacuum chamber
|
Tue Apr 17 19:51:54 2012, tara, Notes, optic, windows for vacuum chamber
|
Thu Apr 19 03:12:23 2012, tara, Notes, optic, windows for vacuum chamber
|
Sun Apr 22 23:09:38 2012, tara, Notes, optic, windows for vacuum chamber
|
Mon Apr 23 16:52:16 2012, tara, Notes, optic, windows for vacuum chamber
|
Wed Apr 25 10:44:29 2012, Frank, Notes, optic, windows for vacuum chamber
|
Thu Apr 26 08:35:57 2012, steve, Notes, optic, windows for vacuum chamber
|
Fri Apr 27 08:46:24 2012, Frank, Notes, optic, windows for vacuum chamber
|
Tue May 1 20:37:16 2012, tara, Notes, optic, windows for vacuum chamber
|
Fri May 11 17:52:17 2012, tara, Notes, optic, windows for vacuum chamber
|
Wed May 16 22:27:13 2012, tara, Notes, optic, windows for vacuum chamber 
|
Mon May 21 16:53:38 2012, tara, Notes, optic, windows for vacuum chamber  
|
Wed May 23 15:04:53 2012, steve, Notes, optic, windows for vacuum chamber
|
|
Message ID: 931
Entry time: Sun Apr 22 23:09:38 2012
In reply to: 926
Reply to this: 932
|
Author: |
tara |
Type: |
Notes |
Category: |
optic |
Subject: |
windows for vacuum chamber |
|
|
For small window option, I can either have it made from scratch ( based on LIGO's drawing) or buy the commercial windows from Thorlabs. Here I listed down all pros and cons for each choice as I discussed it with Frank. I 'll ask Steve tomorrow for his opinions.
== Using Thorlabs 2.75" OD windows:==
Pros
- easy to replace for damaged optics,
- ready in short time (parts are in stock)
- minimum time on machine shop
- The thickness of the window is only 0.63", It should be able to fit in the set up which has ~ 1" clearance.
cons:
- Have more rubber seals in the system due to the design, I'll check Cryo:194 to see what will be the minimum pressure we need.
==Making custom parts (like LIGO, see quote window)==
Pros:
- There are only one o-ring used for each window (better vacuum pressure)
cons:
- Spend more time on designing/machining, probably more money for making the parts as well.
- Take longer time if we need more spare pieces.
- The available space for the window is quite limited (1"). If we follow what Zach did for Gyro, it is already to thick for our setup
|