Message ID: 787     Entry time: Thu Jan 19 01:19:31 2012     In reply to: 785     Reply to this: 789
Author: tara 
Type: DailyProgress 
Category: optic 
Subject: 14.75MHz EOM 

The 14.75 MHz EOM we have is for visible light, so we went to TNI and borrowed a 14.75 MHz EOM for IR and an 14.75 Mhz resonant RFPD.  I will re-aligned the beam and measure the error signal tomorrow.

 The current function generator can provide power up to 23dBm. So the EOM can be driven around ~ 19 dBm(~2V@ 50Ohm) (-3 dBm for a splitter, -1 dBm for loss in the cable). So we can expect the modulation index to be 0.2*2 = 0.4 rad.