Message ID: 721     Entry time: Thu Nov 3 01:55:03 2011     In reply to: 717
Author: Frank 
Type: Notes 
Category: Seismic 
Subject: ring down measurement for rubber spring 

The total mass of the load including the accelerometer was 397g. Will recalculate the spring constant an damping of the RTV later.

 