Message ID: 690     Entry time: Wed Sep 21 01:39:11 2011     In reply to: 688
Author: tara 
Type: DailyProgress 
Category: BEAT 
Subject: seismic noise coupling 

The beat signal I measured today(orange) has noise level close to what we had before (blue,purple), so I'll try to check it again tomorrow. Meanwhile, this is the plot with beat signal when we modified the suspension (removed the spring), and the cavities were in two separate chambers (blue). The noise level around 20-100 Hz is very similar to what we have right now. Since the spring filters mostly vertical seismic, these peaks should be mostly vertical seismic coupling into the system.

beat_2011_09_20_m.png

Quote:

Tara showed me a quick plot which showed the spectrum taken with the new (current) setup and the one taken when we removed the springs from the wire suspension. They look pretty identical between 10Hz and 100Hz or so. So it is likely that we see a lot of vertical seismic. I've measured a little bit at low frequencies to see where we are and we are better than before now, i would guess an order of magnitude or so, without any optimized stabilization, alignment and loops. Tara will take a nice set of measurements tomorrow and make a nice plot. The peak at 6.7Hz or so is actually the horizontal motion of the two top stack plates (not only the top plate). I used our pzt-shaker to shake the table and even with a small signal i could increase it until i got scatter noise bumps around 100Hz. So we have to damp this somehow. Is there an easy way to get some more vertical isolation? what about putting the top plate on a few springs instead of rubber? How much do you typically get when floating the table? I don't have realistic numbers for that...

We also don't have a seismometer. Jenne took her's back and Jan shipped the others back to where they came from i think. i think we should get one which we can share between labs in bridge which we can keep for longer. We needed one quite often in the past couple of months and i guess once we start with the cryo cavity we will even more frequently. Any idea where to get a cheap one? We don't need an STS-2 or so... Seismic sucks anyway in bridge...

The problem with moving supports is that the spacer has pretty wide groves. But we have to think about a clever support anyways. Currently it's sitting on viton in the groves of the spacer, which, according to comsol, is very close to the optimum position but who knows in reality.

Quote:

By taking the passive transfer function between a vertical seismometer on the table and the individual cavity signals, we should be able to see which direction to move the cavity supports so as to minimize the seismic coupling.

Our first iteration probably will have a sign error, but by making a few iterations we ought to be able to home in on a better support. Also, we should compare the theoretical estimate with the measured coupling in units of strain/(m/s^2).

 

 

Attachment 2: beat_2011_09_20_m.fig  256 kB  Uploaded Wed Sep 21 02:58:05 2011