Tue Jan 25 16:30:16 2011, Tara, Frank, DailyProgress, Electronics Equipment, RCAV RFPD fixed  
|
Fri Jan 28 13:35:35 2011, Tara, Frank, DailyProgress, Electronics Equipment, RCAV RFPD fixed 
|
Sun Jan 30 22:58:35 2011, Tara, DailyProgress, Electronics Equipment, RCAV RFPD fixed
|
|
Message ID: 456
Entry time: Fri Jan 28 13:35:35 2011
In reply to: 454
Reply to this: 457
|
Author: |
Tara, Frank |
Type: |
DailyProgress |
Category: |
Electronics Equipment |
Subject: |
RCAV RFPD fixed |
|
|
The TF of 2 35.5MHz RFPD and 21.5 MHz RFPD are measured by the Jenne laser. RCAV's RFPD has the better response, while ACAV's RFPD peak is slightly shift to 37 MHz. But the peak is low Q so we lose only a few dB. PMC's RFPD is now tune to have a resonance peak at 21.5 MHz and a notch at 43 MHz as it should be.
|
|
|
|
|