What are the units of the vert axes?
Separate the open loop gain into three part:
- Optical Gain, Unit [V/m] or [V/Hz], usually flat or simple low path shape
- Servo Filter Gain, Unit [V/V], various shape
- Actuator Gain, Unit [m/V] or [Hz/V], flat or low path filter like up to kHz~100kHz (depending on the time constant of the RC filter),
mechanical resonances above that freq region, which usually determin the highest UGF.
You can change the servo gain by modifying the circuit.
You can change the optical gain by changing the amount of the light in the cavity / on the PD as well as changing the cavity finesse etc.
You can change the actuator gain by replacing the actuator.
Quote: |
Sorry for the confusion, PZT actuator is included in the optical TF.
The plot on fig2 below shows the TF of PZT part, offset by 1 dB to match the misnomer optical path TF.
Thus, the real optical TF is rather flat with magnitude~ 1 dB, the phase shift is 180 degree,
and the modifiable TF (LISO model) is plot on fig1. This plot has not taken the gain from the slider into account yet.
Quote: |
Incomprehensible.
Why is the optical TF not (kinda) flat?
Why does the PZT actuator completely ignored?
You need to talk to me tomorrow afternoon when I am in ATF.
Quote: |
I determined the OLG TF of the whole PMC loop, and TFs from servo paths and optical path.
We want to modify the PMC servo to optimize the PMC loop, so we have to know what are the TFs from part where we can modify,
and where we can't (optical path).
The whole TF is measured before, but I remeasured again just to make sure that there won't be any problem from the laser.
How I measure the whole TF is [here].
I measured the OLG TF from the PMC servo. The results agree well with the LISO model, see fig 1.
Then,
Optical TF = Whole TF - Servo TF.
The Optical TF won't be modified. It will be used to compute the whole TF after the PMC servo modification.
The measurement at low frequency does not look nice because the signal was suppressed by the gain.
But the TF around UGF still looks fine to work with.
|
|
|
|