Entry  Sun Jan 24 18:35:47 2010, Frank, Laser, RefCav, new slow actuator values 
    Reply  Tue Jan 26 03:38:10 2010, rana, Laser, RefCav, frequency findings  
       Reply  Wed Jan 27 11:25:33 2010, Frank, Laser, RefCav, frequency findings  
          Reply  Wed Feb 3 16:19:52 2010, Tara Chalermsongsak, Laser, RefCav, frequency findings  power_at_AOM.jpgReflected_pwr_from_AOM.jpg
             Reply  Wed Feb 3 18:58:50 2010, Tara, Laser, RefCav, frequency findings  comparison.JPGTbeam.JPGRbeam.JPG
Message ID: 37     Entry time: Sun Jan 24 18:35:47 2010     Reply to this: 38
Author: Frank 
Type: Laser 
Category: RefCav 
Subject: new slow actuator values 

- more insulation to the refcav chamber added

actual slow actuator values for both cavities:
refcav : 0.4385
acav : 0.2539

-> ~215MHz difference

with ~6mK/Mhz  -> refcav temp reduced by 1.3K

01/25/10  8am:

refcav temp now 67.7, slow actuator 0.304 -> reduced temp further to 67.5

01/26/10  1pm: 

refcav : 0.243
acav : 0.251

01/27/10  11am

refcav: 0.2456    temp:67.4
acav: 0.2582      temp: 40.0

01/27/10  9 pm

refcav: 0.2423    temp:67.55
acav: 0.2578      temp: 40.0

01/28/10  1am

refcav: 0.2525   temp:67.65
acav: 0.2578      temp: 40.0

01/29/10  4 pm

refcav: 0.2485   temp:67.65
acav: 0.2335      temp: 40.0