i tried to figure out where the network problems come from. Looks like it's the fiber connection between fb1 and the switch in the PSL lab.
Here a result from a simple ping between fb1 and the other computers. It acrually doesn't matter which one.
--- 10.0.0.1 ping statistics ---
1000 packets transmitted, 817 received, 18% packet loss, time 201397ms
rtt min/avg/max/mdev = 0.169/0.233/0.381/0.025 ms
--- 10.0.0.2 ping statistics ---
1000 packets transmitted, 786 received, 21% packet loss, time 202036ms
rtt min/avg/max/mdev = 0.617/0.694/2.658/0.152 ms
--- 10.0.0.3 ping statistics ---
1000 packets transmitted, 796 received, 20% packet loss, time 201696ms
rtt min/avg/max/mdev = 0.410/0.453/2.655/0.081 ms
Pings between computers within the PSL lab but connected to the same switch are OK:
--- 10.0.0.1 ping statistics ---
1000 packets transmitted, 1000 received, 0% packet loss, time 202998ms
rtt min/avg/max/mdev = 0.000/1.092/13.755/1.340 ms
--- 10.0.0.2 ping statistics ---
1000 packets transmitted, 1000 received, 0% packet loss, time 203161ms
rtt min/avg/max/mdev = 0.200/1.719/13.230/1.545 ms
So i think it's the fiber connection.
|