40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Message ID: 284     Entry time: Mon Aug 16 19:40:52 2010
Author: tara 
Type: Notes 
Category: NoiseBudget 
Subject: MATLAB simulation 1D 

After my fail attempt on simulating those thin layers of coatings on COMSOL, I turned back to MATLAB.

The model is based on 1-D heat equation. I haven't add the effect of coating yet. This will be done soon after.

I assume no radiative loss on any surface, only the effect from AC input. The boundary condition is sinusoidal on the

reflecting surface of the mirror, and no heat flow at the back of the mirror (dT/dz = 0).

Attachment 1: contourplot.png  8 kB  | Hide | Hide all
contourplot.png
Attachment 2: T_Z.png  5 kB  | Hide | Hide all
T_Z.png
Attachment 3: heatflow.m  2 kB  | Hide | Hide all
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%% Script to solve the heat equation substrate with
%%% sinusoidal T at the surface
%%% 2010 Aug 16,
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%

%%% Initialize variables
dz = 1e-7; %each depth step is 0.1 um
Nz = 400; % Choose the number of depth steps (should go to at least 100 um)
Nt = 5000; % Choose the number of time steps
... 48 more lines ...