we set up a second, independent DAQ system for the analyzer cavity. It has one 16bit D/A card, 16bit A/D card and 12bit A/D card. The system is called "acav1" and has the ip-address 10.0.0.3, which we can access from the ATF as well via fb1 (fb1 is in peters network too). Here is a boot screen dump of the new system with a list of the new channels at the end. The new channels are now in C3, the new numbering scheme for the PSL subsystem, not in C anymore! (but all the old channels are still C as i would take to long to change all the existing medm screens...

 

                            VxWorks System Boot


Copyright 1984-1996  Wind River Systems, Inc.





CPU: Heurikon Baja4700
Version: 5.3.1
BSP version: 1.1/1
Creation date: Dec 11 1998, 10:29:37




Press any key to stop auto-boot...
 0
auto-booting...


boot device          : ei
processor number     : 0
host name            : bdl1
file name            : /usr1/epics/baja/vxWorks
inet on ethernet (e) : 10.0.0.3:ffffff00
host inet (h)        : 10.0.0.1
user (u)             : root
flags (f)            : 0x0
target name (tn)     : acav1
startup script (s)   : /usr1/epics/acav/startup.cmd

Mapping RAM base to A32 space at 0x40000000... done.
No longer waiting for sysFail to clear. D.Barker 14th Sept 1998
Attaching network interface ei0... done.
Attaching network interface lo0... done.
Loading... 795028
Starting at 0x80010000...

Mapping RAM base to A32 space at 0x40000000... done.
No longer waiting for sysFail to clear. D.Barker 14th Sept 1998
Attaching network interface ei0... done.
Attaching network interface lo0... done.
Mounting NFS file systems from host bdl1 for target acav1:
...done
Loading symbol table from bdl1:/usr1/epics/baja/vxWorks.sym ...done


 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
      ]]]]]]]]]]]  ]]]]     ]]]]]]]]]]       ]]              ]]]]         (R)
 ]     ]]]]]]]]]  ]]]]]]     ]]]]]]]]       ]]               ]]]]
 ]]     ]]]]]]]  ]]]]]]]]     ]]]]]] ]     ]]                ]]]]
 ]]]     ]]]]] ]    ]]]  ]     ]]]] ]]]   ]]]]]]]]]  ]]]] ]] ]]]]  ]]   ]]]]]
 ]]]]     ]]]  ]]    ]  ]]]     ]] ]]]]] ]]]]]]   ]] ]]]]]]] ]]]] ]]   ]]]]
 ]]]]]     ]  ]]]]     ]]]]]      ]]]]]]]] ]]]]   ]] ]]]]    ]]]]]]]    ]]]]
 ]]]]]]      ]]]]]     ]]]]]]    ]  ]]]]]  ]]]]   ]] ]]]]    ]]]]]]]]    ]]]]
 ]]]]]]]    ]]]]]  ]    ]]]]]]  ]    ]]]   ]]]]   ]] ]]]]    ]]]] ]]]]    ]]]]
 ]]]]]]]]  ]]]]]  ]]]    ]]]]]]]      ]     ]]]]]]]  ]]]]    ]]]]  ]]]] ]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]       Development System
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]       VxWorks version 5.3.1
 ]]]]]]]]]]]]]]]]]]]]]]]]]]       KERNEL: WIND version 2.5
 ]]]]]]]]]]]]]]]]]]]]]]]]]       Copyright Wind River Systems, Inc., 1984-1997

                               CPU: Heurikon Baja4700.  Processor #0.
                              Memory Size: 0x1000000.  BSP version 1.1/1.
                             WDB: Ready.

Executing startup script /usr1/epics/acav/startup.cmd ...
shellPromptSet "acav> "
value = -2146677404 = 0x800c4d64 = shellHistSize + 0x4
cd "/usr1/epics/baja"
value = 0 = 0x0
ld < iocCore
value = -2130992736 = 0x80fba1a0 = prsrv_cast_client + 0x770
ld < drvSup
value = -2131103904 = 0x80f9ef60
ld < devSup
value = -2132426208 = 0x80e5c220 = pwf_xy566 + 0x70
ld < recSup
value = -2132416016 = 0x80e5e9f0
ld < seq
value = -2130995152 = 0x80fb9830
dbLoad "default.dctsdr"
value = 0 = 0x0
cd "/usr1/epics/acav/db"
value = 0 = 0x0
dbLoadRecords "n3113.db"
value = 0 = 0x0
dbLoadRecords "n3123a.db"
value = 0 = 0x0
dbLoadRecords "n4116.db"
value = 0 = 0x0
cd "usr1/epics/baja"
value = 0 = 0x0
TSconfigure(0)
value = 1 = 0x1
iocInit "resource.def"
############################################################################
###  @(#)EPICS IOC CORE
###  @(#)Version R3.12.2patch1 Date: 1996/04/02
############################################################################
bdl1:sh: /usr1/epics/acav/db/usr1/epics/baja/resource.def: cannot open
task: 0X80fbf430 tShell
iocLogClient: unable to connect to 164.54.8.167 port 7004 because "errno = 0x33"

Unable to start log server connection watch dog
No such Resource file - resource.def
vmi4116_addr 1f045c00
entry 0 address 0x0
entry 1 address 0x0
entry 2 address 0x0
entry 3 address 0x6000
entry 4 address 0x7000
entry 5 address 0xe000
entry 6 address 0xc014
entry 7 address 0x0
entry 8 address 0x0
entry 9 address 0xff00
entry 10 address 0x0
entry 11 address 0x0
entry 12 address 0x0
entry 13 address 0x0
entry 14 address 0x2000
entry 15 address 0x2c00
Failed to set time from Unix server
0x80fbf430 (tShell): iocInit: Database Failed during Initialization
0x80fbf430 (tShell): iocInit: All initialization complete
value = 0 = 0x0
coreRelease()
############################################################################
###  @(#)EPICS IOC CORE
###  @(#)Version R3.12.2patch1 Date: 1996/04/02
############################################################################
value = 226 = 0xe2
0x80f435f0 (CA UDP): CAS: couldnt start up online notify task
OK.

Done executing startup script /usr1/epics/acav/startup.cmd
acav> dbl
C3:PSL-GEN_12DAQ1
C3:PSL-GEN_12DAQ10
C3:PSL-GEN_12DAQ11
C3:PSL-GEN_12DAQ12
C3:PSL-GEN_12DAQ13
C3:PSL-GEN_12DAQ14
C3:PSL-GEN_12DAQ15
C3:PSL-GEN_12DAQ16
C3:PSL-GEN_12DAQ17
C3:PSL-GEN_12DAQ18
C3:PSL-GEN_12DAQ19
C3:PSL-GEN_12DAQ2
C3:PSL-GEN_12DAQ20
C3:PSL-GEN_12DAQ21
C3:PSL-GEN_12DAQ22
C3:PSL-GEN_12DAQ23
C3:PSL-GEN_12DAQ24
C3:PSL-GEN_12DAQ25
C3:PSL-GEN_12DAQ26
C3:PSL-GEN_12DAQ27
C3:PSL-GEN_12DAQ28
C3:PSL-GEN_12DAQ29
C3:PSL-GEN_12DAQ3
C3:PSL-GEN_12DAQ30
C3:PSL-GEN_12DAQ31
C3:PSL-GEN_12DAQ32
C3:PSL-GEN_12DAQ33
C3:PSL-GEN_12DAQ34
C3:PSL-GEN_12DAQ35
C3:PSL-GEN_12DAQ36
C3:PSL-GEN_12DAQ37
C3:PSL-GEN_12DAQ38
C3:PSL-GEN_12DAQ39
C3:PSL-GEN_12DAQ4
C3:PSL-GEN_12DAQ40
C3:PSL-GEN_12DAQ41
C3:PSL-GEN_12DAQ42
C3:PSL-GEN_12DAQ43
C3:PSL-GEN_12DAQ44
C3:PSL-GEN_12DAQ45
C3:PSL-GEN_12DAQ46
C3:PSL-GEN_12DAQ47
C3:PSL-GEN_12DAQ48
C3:PSL-GEN_12DAQ49
C3:PSL-GEN_12DAQ5
C3:PSL-GEN_12DAQ50
C3:PSL-GEN_12DAQ51
C3:PSL-GEN_12DAQ52
C3:PSL-GEN_12DAQ53
C3:PSL-GEN_12DAQ54
C3:PSL-GEN_12DAQ55
C3:PSL-GEN_12DAQ56
C3:PSL-GEN_12DAQ57
C3:PSL-GEN_12DAQ58
C3:PSL-GEN_12DAQ59
C3:PSL-GEN_12DAQ6
C3:PSL-GEN_12DAQ60
C3:PSL-GEN_12DAQ61
C3:PSL-GEN_12DAQ62
C3:PSL-GEN_12DAQ63
C3:PSL-GEN_12DAQ64
C3:PSL-GEN_12DAQ7
C3:PSL-GEN_12DAQ8
C3:PSL-GEN_12DAQ9
C3:PSL-GEN_DAQ1
C3:PSL-GEN_DAQ10
C3:PSL-GEN_DAQ11
C3:PSL-GEN_DAQ12
C3:PSL-GEN_DAQ13
C3:PSL-GEN_DAQ14
C3:PSL-GEN_DAQ15
C3:PSL-GEN_DAQ16
C3:PSL-GEN_DAQ2
C3:PSL-GEN_DAQ3
C3:PSL-GEN_DAQ4
C3:PSL-GEN_DAQ5
C3:PSL-GEN_DAQ6
C3:PSL-GEN_DAQ7
C3:PSL-GEN_DAQ8
C3:PSL-GEN_DAQ9
C3:PSL-GEN_D2A1
C3:PSL-GEN_D2A2
C3:PSL-GEN_D2A3
C3:PSL-GEN_D2A4
C3:PSL-GEN_D2A5
C3:PSL-GEN_D2A6
C3:PSL-GEN_D2A7
C3:PSL-GEN_D2A8
value = 0 = 0x0
acav>