Entry  Fri Oct 4 13:41:44 2019, anchal, Notes, FSS, FSS Plant Model FSS_Plant_Zero_Sim.pdfPlantModel.pdfPlantModel.zip
    Reply  Fri Oct 4 14:56:42 2019, Ian MacMillan, Notes, FSS, FSS Plant Model PlantModelCircuit.pdf
       Reply  Tue Oct 8 10:41:43 2019, anchal, Notes, FSS, FSS Plant Model 
          Reply  Mon Oct 14 12:54:41 2019, anchal, Notes, FSS, FSS Plant Model v2 FSS_Plant_Zero_Sim.pdfPlantModelv2.pdfPlantModelv2.zip
             Reply  Tue Oct 22 13:07:45 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PlantDig.pdfEOM_Transfer_Function.pdfPZT_Transfer_Function.pdf
                Reply  Thu Oct 24 11:42:06 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
                   Reply  Tue Dec 3 17:27:54 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 IMG_8065.jpegIMG_8069.jpeg
                      Reply  Mon Dec 9 18:08:13 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 OutputGraphsTransferFunction.pdf_Circuit_Design_V1.zip
                         Reply  Tue Dec 10 11:57:58 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 IMG_8124.jpeg
                            Reply  Thu Dec 12 11:54:11 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PZT_LowFq_V1.pdfPZT_HighFq_V1.pdfEOM_LowFq_V1.pdfEOM_HighFq_V1.pdf
                               Reply  Thu Dec 12 19:05:33 2019, rana, Notes, FSS, FSS Plant Model v2 
                                  Reply  Mon Dec 16 09:43:56 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PZT_TF.pdfEOM_TF.pdfNon-Moku_Data_PlantCir_V1.zip
                                     Reply  Tue Jan 14 13:30:39 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 EOM_TF_V1.pdfPZT_TF_V1.pdfPlant_CIR_TF.zip
                                        Reply  Tue Jan 14 13:32:16 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 FSSPlantModelV2SCH.pdfFSSPlantModelV2.pdfPlant_Circuit_Board_Eagle.zip
                                           Reply  Tue Jan 28 13:27:25 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 LIGO-D2000020-v1.pdfBOARD_LIGO-D2000020-v1.pdfEagle_LIGO-D2000020-v1.zip
                                              Reply  Mon Feb 10 12:46:17 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
                                              Reply  Fri Feb 14 16:46:47 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 TFAG4395A_14-02-2020_155048.pdfTFAG4395A_14-02-2020_165608.pdf
                                                 Reply  Tue Feb 18 15:42:46 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 PZT_TF_V1.pdfEOM_TF_V1.pdfTransfer_Functions_FSS.zip
                                                    Reply  Tue Mar 3 17:13:04 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 image.pngPLT_Spectrum.pdf20200303_IanSimPlant.zipPLT_Spectrum.pdfPLT_TF.pdf
                                                       Reply  Wed Mar 11 15:40:50 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 TFSR785_06-03-2020_135844_PZT.pdfTF_V1.zip
                                                          Reply  Thu Mar 12 16:21:49 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 TFSR785_10-03-2020_175129.pdfTFSR785_10-03-2020_175129.txt
                                                          Reply  Thu Mar 12 17:18:51 2020, rana, Notes, FSS, FSS Plant Model v2 
Message ID: 2557     Entry time: Thu Mar 12 16:21:49 2020     In reply to: 2554
Author: Ian MacMillan 
Type: Notes 
Category: FSS 
Subject: FSS Plant Model v2 

We added hooked up the plant and measured the in loop transfer function (shown below). The circuit locked in the system... so it works.

Next, we want to measure it with the south FSS to compare the two since anchal tells me he has never seen a direct comparison of the two.

We also need to calculate the gain of the full system. I am trying to do this on my own and get help from Anchal when I run into a problem.

Attachment 1: TFSR785_10-03-2020_175129.pdf  21 kB  | Hide | Hide all
TFSR785_10-03-2020_175129.pdf
Attachment 2: TFSR785_10-03-2020_175129.txt  16 kB  Uploaded Thu Mar 12 17:21:57 2020  | Hide | Hide all
# SR785 Measurement - Timestamp: Mar 10 2020 - 17:51:29
# Parameter File: TFSR785template.yml
#---------- Measurement Setup ------------
# Start frequency (Hz) = 100000.000000
# Stop frequency (Hz) = 10.000000
# Number of frequency points = 300
# Excitation amplitude (mV) = 15.000000
# Settling cycles = 1
# Integration cycles = 25
#---------- Measurement Parameters ----------
... 321 more lines ...
ELOG V3.1.3-