40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Fri Nov 1 17:54:47 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Ouput under inspection NFSS_RFPD_Output_Oscilloscope.pdfSFSS_RFPD_Output_Oscilloscope.pdfNFSS_RFPD_RF_OUT_COUPLED.pdfSFSS_RFPD_RF_OUT_COUPLED.pdf
    Reply  Tue Nov 5 18:37:59 2019, anchal, DailyProgress, FSS, FSS Diagnostics - TTFSS Testpoint Spectrum Data FSS_TP_Spectrum.pdf
       Reply  Sat Nov 9 19:28:36 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Loop nonlinearity Test NFSS_NonLinearity_Test.pngSFSS_NonLinearity_Test.pngsignal-attachment-2019-11-09-195635.jpeg
          Reply  Mon Nov 11 20:42:49 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Two Tone Test NFSS_RFPD_SN009_TF_11-11-2019_183131.pdfSFSS_RFPD_SN010_TF_11-11-2019_203310.pdfFSStwoToneTest.pdf
             Reply  Tue Nov 12 18:36:59 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Two Tone Third Order Intermodulation Test FSStwoToneThirdOrderIM.pdf
                Reply  Thu Nov 14 12:19:32 2019, rana, DailyProgress, FSS, FSS Diagnostics - Two Tone Third Order Intermodulation Test 
                   Reply  Tue Nov 19 18:51:02 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Second-order Distortion Calculation FSSDistortionCalc.pdfFSSDistortion.zip
                      Reply  Mon Dec 9 19:54:44 2019, anchal, DailyProgress, FSS, FSS Diagnostics - How much distortion affects the functioning of PDH? 
       Reply  Wed Nov 27 13:59:24 2019, anchal, DailyProgress, FSS, FSS Diagnostics - TTFSS TP1 TimeSeries NFSS_TP1_Oscilloscope.pdf
          Reply  Wed Nov 27 15:17:51 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Quick HF OLTF of NFSS NFSS_OLTF_HF.pdf
             Reply  Wed Nov 27 16:31:20 2019, rana, DailyProgress, FSS, FSS Diagnostics - Quick HF OLTF of NFSS 
                Reply  Wed Dec 4 18:11:09 2019, anchal, DailyProgress, FSS, Free running laser frequency noise spectrum PMCErrorSignals.pdf
                   Reply  Thu Dec 5 18:25:11 2019, rana, DailyProgress, FSS, Free running laser frequency noise spectrum 
                   Reply  Tue Dec 17 18:29:58 2019, anchal, DailyProgress, FSS, Need for ISS? 
                      Reply  Wed Dec 18 18:40:32 2019, anchal, DailyProgress, FSS, Maybe the NPRO Laser isn't bad after all NorthLaserRINAnalysis.pdf
                         Reply  Wed Dec 18 22:03:17 2019, rana, DailyProgress, FSS, Maybe the NPRO Laser isn't bad after all 
                            Reply  Fri Dec 20 15:00:30 2019, anchal, DailyProgress, FSS, PZT, EOM to RIN TF Measurement NorthLaserPZTEOMtoRINTF.pdf
                               Reply  Fri Dec 20 18:08:44 2019, anchal, DailyProgress, FSS, PZT, EOM to RIN TF Measurement Through FSS NorthLaserPZTEOMtoRINTFThruFSS.pdf
                                  Reply  Tue Jan 7 17:59:20 2020, anchal, DailyProgress, FSS, NPMC TF NPMC_TF.pdf
       Reply  Thu Dec 12 19:15:55 2019, anchal, DailyProgress, FSS, FSS Diagnostics - Beatnote Spectrum wrt Laser Power and Modulation Index BeatnoteSpectrumwrtPowerandModindex.pdf
       Reply  Tue Dec 17 16:55:07 2019, anchal, DailyProgress, FSS, FSS Diagnostics - TTFSS North U7 Boost Stage Input-Output TimeSeries NFSS_UT_TS_Analysis.pdf
    Reply  Tue Nov 12 11:39:48 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Ouput under inspection 
    Reply  Fri Dec 13 16:24:02 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD Circuit Latest Available Photos SN009.jpgSN010.jpgSN009.jpgSN010.jpg
    Reply  Fri Dec 13 17:44:05 2019, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Coupled Output Offset 
       Reply  Mon Jan 13 19:04:38 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN009 (North RFPD) Notch Improvement Attempt SN009.jpgSN009_D980454-00-C.pdfSN009_Notch_Improvement_Attempt.pdf
          Reply  Tue Jan 14 18:19:33 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN009 (North RFPD) Notch Improved! SN009.jpgSN009_D980454-00-C.pdfSN009_Notch_Improvement_Attempt.pdf
             Reply  Thu Jan 16 11:17:15 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN010 (South RFPD) Notch Improvement Attempt SN010.jpgSN010_D980454-00-C.pdfSN010_Notch_Improvement_Attempt.pdf
                Reply  Thu Jan 16 20:18:44 2020, anchal, DailyProgress, FSS, FSS Diagnostics - SN010 (South RFPD) Notch Improved SN010.jpgSN010_D980454-00-C.pdfSN010_Notch_Improved.pdf
                   Reply  Mon Jan 27 18:29:19 2020, anchal, DailyProgress, FSS, FSS Diagnostics - RFPD RF Out Spectrum FSS_RFPD_RFOut_Spectrum.pdf
Message ID: 2496     Entry time: Fri Dec 13 16:24:02 2019     In reply to: 2470
Author: anchal 
Type: DailyProgress 
Category: FSS 
Subject: FSS Diagnostics - RFPD Circuit Latest Available Photos 

I found the latest available photos for the Cavity Reflection RFPD circuits.

SN009 as of March 25, 2019
SN009 as of March 25, 2019
SN010 as of April 1st, 2019
SN010 as of April 1st, 2019

There were minor changes made after taking these photos which are logged at: https://nodus.ligo.caltech.edu:30889/ATFWiki/doku.php?id=main:experiments:psl:rfpd

I'll update these above photos whenever the next time I get a chance. They would be present at:

SN009: https://git.ligo.org/cit-ctnlab/ctn_electronics/blob/master/RFPD/Photos/SN009.jpg

SN010: https://nodus.ligo.caltech.edu:30889/ATFWiki/doku.php?id=main:experiments:psl:rfpd

Attachment 3: SN009.jpg  3.801 MB  | Show | Hide all | Show all
Attachment 4: SN010.jpg  2.998 MB  | Hide | Hide all | Show all
SN010.jpg
ELOG V3.1.3-