Thu Jan 10 10:39:27 2019, anchal, DailyProgress, NoiseBudget, New noise budget code is ready, but
|
Mon Aug 12 11:56:21 2019, anchal, DailyProgress, NoiseBudget, Adding specifics of discepancy
|
Tue Aug 13 11:59:56 2019, anchal, DailyProgress, NoiseBudget, Checking the differences between old and new noisebudget 
|
Tue Aug 13 17:05:53 2019, aaron, DailyProgress, NoiseBudget, Checking the differences between old and new noisebudget
|
Tue Sep 24 15:40:33 2019, anchal, DailyProgress, NoiseBudget, Adding specifics of discepancy 2
|
Tue Sep 24 17:11:13 2019, anchal, DailyProgress, NoiseBudget, Adding specifics of discepancy 2 (More)
|
Tue Sep 24 19:39:06 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles 
|
Fri Sep 27 16:40:49 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles Better Plots 
|
Mon Sep 30 11:14:41 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles 2D Plots 
|
Mon Sep 30 12:25:24 2019, rana, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Loss Angles 2D Plots
|
Mon Sep 30 20:08:42 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Beam Radius 
|
Tue Oct 1 13:46:49 2019, anchal, DailyProgress, NoiseBudget, Using bayesian inference to estimate loss Angles 
|
Wed Oct 2 15:13:27 2019, anchal, DailyProgress, NoiseBudget, Checking variation in estimated Coating Brownian Noise with Beam Radius 
|
Wed Oct 23 13:21:12 2019, anchal, DailyProgress, NoiseBudget, Fixed all discrepancies.  
|
Fri Jun 12 12:34:08 2020, anchal, DailyProgress, NoiseBudget, Resolving discrepancy #1 concretly
|
|
Message ID: 2463
Entry time: Wed Oct 23 13:21:12 2019
In reply to: 2442
|
Author: |
anchal |
Type: |
DailyProgress |
Category: |
NoiseBudget |
Subject: |
Fixed all discrepancies. |
|
|
I ran the code for aLIGO coating structure and tried to reproduce fig5 and fig7 of Hong et al. paper. It turned out that the derivatives of the complex reflectivity were not matching with the paper. I rewrote the code, with a fresh mind without looking at previous code and voila, after increasing computation time slightly due to more brute force calculations, I was able to reproduce the figures. These figures are attached. Since I do not have access to the data of the figures in the paper (I tried to email the authors but got no replies), I could only try to plot it on the same scale and limits and check the values by eyes. The values seem to match. So I am more confident now to declare that this code completely follows the paper's calculations.
However, this does not change the coating Brownian noise. I have updated the noise budgets at the Daily and Latest plots. |
|
|
|
|
|