40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
PSL |
Not logged in |
 |
|
Fri Oct 4 13:41:44 2019, anchal, Notes, FSS, FSS Plant Model  
|
Fri Oct 4 14:56:42 2019, Ian MacMillan, Notes, FSS, FSS Plant Model
|
Tue Oct 8 10:41:43 2019, anchal, Notes, FSS, FSS Plant Model
|
Mon Oct 14 12:54:41 2019, anchal, Notes, FSS, FSS Plant Model v2  
|
Tue Oct 22 13:07:45 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2  
|
Thu Oct 24 11:42:06 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2
|
Tue Dec 3 17:27:54 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
|
Mon Dec 9 18:08:13 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
|
Tue Dec 10 11:57:58 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2
|
Thu Dec 12 11:54:11 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2   
|
Thu Dec 12 19:05:33 2019, rana, Notes, FSS, FSS Plant Model v2
|
Mon Dec 16 09:43:56 2019, Ian MacMillan, Notes, FSS, FSS Plant Model v2  
|
Tue Jan 14 13:30:39 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2  
|
Tue Jan 14 13:32:16 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2  
|
Tue Jan 28 13:27:25 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2  
|
Mon Feb 10 12:46:17 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2
|
Fri Feb 14 16:46:47 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
|
Tue Feb 18 15:42:46 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2  
|
Tue Mar 3 17:13:04 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2    
|
Wed Mar 11 15:40:50 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
|
Thu Mar 12 16:21:49 2020, Ian MacMillan, Notes, FSS, FSS Plant Model v2 
|
Thu Mar 12 17:18:51 2020, rana, Notes, FSS, FSS Plant Model v2
|
|
Message ID: 2462
Entry time: Tue Oct 22 13:07:45 2019
In reply to: 2450
Reply to this: 2465
|
Author: |
Ian MacMillan |
Type: |
Notes |
Category: |
FSS |
Subject: |
FSS Plant Model v2 |
|
|
I have designed a passive circuit that seems to match the ideal transfer functions in shape. Scaling should just be a game of playing with the values of the resistors and capacitors. The phase still seems to be an issue. There is an unwanted phase shift from 0 -> -90.
The next step is trying to finalize the values for the resistors and caps. Possibly model in zero if I have time. Then build and test. Also fix the phase.
Quote: |
I have updated the plant model to contain the cavity pole also. Cavity pole is a pair of positive and negative real poles, so it is hard (or maybe impossible) to imitate it exactly with an electronic circuit. Or maybe, my analysis is wrong.
Nevertheless, I have for now made this circuit which has a second-order pole, so it correctly matches the magnitude of the model transfer function up to 1 MHz for both PZT and EOM paths. Note that the elliptical filter is not included in this as we can connect the circuit to Test port 1 which injects just before the filter in LIGO-D0901894. Also, for the gains in EOM path, I had to add some factors to make it the same as the model transfer function. All components are calculated for E12 series resistors and capacitors.
Attached is a pdf of the notebook which contains all the mathematics in latex and a zip file with all files to recreate and further work on this. Ian can use these as support to learn zero further.
|
|
|
|
|
|
|
|