I have written a script which will trigger Moku every day at 3 am to take a beatnote timeseries measurement. It will then calculated the ASD of the data and will save important experiment configuration details in a log file. This will happen in ctn_noisebudget/Data/dailyBeatNoteSpectrum directory.

I have currently configured it to take timeseries for 60s with 10 kHz tracking bandwidth using Koji's SN101 beatnote detector. The cavity temperature control is working nicely with keeping the beatnote close to the peak frequency of 27.34 MHz, within 500 kHz of it atleast.